• Title/Summary/Keyword: Clearances

Search Result 199, Processing Time 0.02 seconds

CO2 Mineral Carbonation Reactor Analysis using Computational Fluid Dynamics: Internal Reactor Design Study for the Efficient Mixing of Solid Reactants in the Solution (전산유체역학을 이용한 이산화탄소 광물 탄산화 반응기 분석: 용액 내 고체 반응물 교반 향상을 위한 내부 구조 설계)

  • Park, Seongeon;Na, Jonggeol;Kim, Minjun;An, Jinjoo;Lee, Chaehee;Han, Chonghun
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.612-620
    • /
    • 2016
  • Aqueous mineral carbonation process, in which $CO_2$ is captured through the reaction with aqueous calcium oxide (CaO) solution, is one of CCU technology enabling the stable sequestration of $CO_2$ as well as economic value creation from its products. In order to enhance the carbon capture efficiency, it is required to maximize the dissolution rate of solid reactants, CaO. For this purpose, the proper design of a reactor, which can achieve the uniform distribution of solid reactants throughout the whole reactor, is essential. In this paper, the effect of internal reactor designs on the solid dispersion quality is studied by using CFD (computational fluid dynamics) techniques for the pilot-scale reactor which can handle 40 ton of $CO_2$ per day. Various combination cases consisting of different internal design variables, such as types, numbers, diameters, clearances and speed of impellers and length and width of baffles are analyzed for the stirred tank reactor with a fixed tank geometry. By conducting sensitivity analysis, we could distinguish critical variables and their impacts on solid distribution. At the same time, the reactor design which can produce solid distribution profile with a standard deviation value of 0.001 is proposed.

Effect of Smoking on Theophylline Pharmacokinetics in Normal Korean Volunteers

  • Park, Kyoung-Ho;Shin, Hyun-Teak;Kim, Nak-Doo
    • Toxicological Research
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 1988
  • In order to evaluate the effect of cigarette smoking on the pharmacokinetics of theophylline in Koreans, doses of 4.5 to 5.0 mg/kg of theophylline, as injectable aminophylline, were administered to 12 normal young volunteers (male, 22 to 35 yrs;mean, 26 yrs) through intravenous infusion over 30 minutes, and pharmacokinetics of theophylline were tested. Among subjects, six were nonsmokers and the other were smokers (range 1 to 2 packs/day). Also the correlations between plasma and saliva theophylline concentrations were investigated by determining the concentrations of theophylline in saliva simultaneously at each plasma sampling time. The total body clearances of theophylline in smokers (Mean${\pm}$SD, 0.0578${\pm}$0.0092 L/hr/kg)were appreciably higher than thoxe of nonsmokers (Mean${\pm}$SD, 0.0359${\pm}$0.0063 L/hr/kg), and the half-lives of theophylline in smokers averaged 5.36${\pm}$1.22hr, and significantly shorter than those of nonsmokers which averaged 9.14${\pm}$1.73hrs(p<0.005). But the apparent volumes of distribution of theophylline did not show any significant difference between smokers (Mean${\pm}$SD,0.44 ${\pm}$0.05L/kg) and nonsmokers (Mean${\pm}$SD, 0.46${\pm}$0.05L/kg). The average concentration ratios in saliva and plasma were 0.61 in smokers and 0.56 in nonsmokers after 2 hrs following drug administrations, and the smoker group had a slightly higher value of ratio(S/P) than the nonsmoker group (p<0.05). The correlations between saliva and plasma theophylline concentration in smokers were r=0.852(p<0.0005) within 2 hr and r=0.985(p<0.0005) after 2 hrs and also those of nonsmokers were r=0.729(p<0.0005) within 2 hrs and r=0.957(p<0.0005) after 2 hrs starting the infusion. From the results, it was found that smoking cigarettes had significantly increased the clearance of theophylline and that the relationships between saliva and plasma theophylline concentrations in all subjects were better after 2 hrs than within 2 hrs starting the infusion of aminophlline.

  • PDF

Numerical Simulation of External Gear Pump Using Immersed Solid Method (Immersed Solid Method 를 이용한 외접형 기어 펌프의 수치해석)

  • Yoon, Yong Han;Park, Byung Ho;Han, Yong Oun;Hong, Byeong Joo;Shim, Jaesool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.95-101
    • /
    • 2014
  • In this study, an ISM (immersed solid method) was used for investigating the mass flow rate and efficiency of an involute-gear pump featuring very high rotational speed. For considering circulation flow at the gear pump and housing, fluid flow was assumed as turbulent, and the rotational speed of the gear pump increased under the condition of constant pressure at both the inlet and outlet. The efficiency and mass flow rate of the gear pump were studied by varying its rotational speed and the clearance between the gear tip and the housing. In the simulation results, as the rotational speed were increased, the average mass flow rate and efficiency increased. Furthermore, as the clearance between the gear tip and the housing was increased, the average mass flow rate and efficiency decreased. The efficiency was 85.11, 90.94, and 93.62 at rotational speeds of 6,000 rpm, 8,000 rpm, and 10,000 rpm, respectively, under the condition that there was no clearance. In addition, the efficiency was 93.62, 93.29, and 92.74 at clearances of 0 m, 0.00001 m, and 0.00003 m respectively.

Comparison of Brain Uptakes for Brain Drug Delivery Vector Synthesized by Chemical and Genetical Engineering Method (화학적 및 유전공학적으로 제조한 뇌송달 벡터의 뇌수송량 비교)

  • Kang, Young-Sook;Seo, Kyung-Hee
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.2
    • /
    • pp.87-92
    • /
    • 1999
  • Drug delivery to the brain may be achieved by producing chimeric peptide, attaching the drug to protein 'vectors' which are transported into the brain from the blood by a receptor-mediated transcytosis through the blood-brain barrier (BBB). Since the BBB expresses high concentrations of transferrin receptor, and it was reported that anti-transferrin receptor mouse monoclonal antibody (OX26) undergoes transcytosis through the BBB, it is logical to assume that a drug delivery system via transferrin receptor-mediated transcytosis is a promising strategy. In the present study, therefore, we tested feasibility of several OX26 based vectors for the brain delivery of a model drug. Avidin-based delivery vectors such as OX26-streptavidin (OX26-SA), OX26-neutralite avidin (OX26-NLA) were chemically synthesized vectors and OX26 immunoglobulin G 3 type $C_{H}3$ fusion avidin $(OX26\;IgG3C_H3-AV)$ was genetically engineered. To improve the efficiency of producing chimeric peptide, we used avidin-biotin technology. Pharmacokinetics of $[^3H]biotin$ bound to OX26-SA, OX26-NLA and $OX26\;IgG3C_H3-AV$ was determined by intravenous injection technique, and their stabilities in plasma were analyzed using HPLC. The brain delivery of $[^3H]biotin$ bound to OX26-SA, OX26-NLA and OX26\;$IgG3C_{H}3-AV$ (expressed as %ID/g brain) was $0.22{\pm}0.01$, $0.18{\pm}0.01$ and $0.25{\pm}0.09$, respectively. The areas under the plasma concentration versus time curve (AUC) for OX26-SA, OX26-NLA, $OX26\;IgG3C_H3-AV$ from time zero to 60 min were $209{\pm}10$, $195{\pm}9$, $134{\pm}29\;%ID\;min/ml$ respectively and their total clearances $(CL_{tot})$ were $1.00{\pm}0.09$, $1.08{\pm}0.07$ and $1.54{\pm}0.29\;ml/min/kg$, espectively. These results showed that these vectors possess preferable pharmaceutical (e.g., resonable stability) and pharmacokinetics (e.g., significant brain uptake and enhanced AUC) for brain delivery. Therefore, these vectors may be broadly useful in the brain delivery of drugs that are not transported into the brain to a significant extent.

  • PDF

A Study of Sloshing Tank on Vessel Motions with Various Baffle Clearance (탱크 내 격벽에 의한 간극 변화가 선박 운동에 미치는 영향 연구)

  • Kim, Kyung Sung;Yu, Sunjin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.796-802
    • /
    • 2018
  • The effects of inner liquid sloshing on vessel motions are a well-known factor. It was investigated experimentally and numerically. In this regard, the study of many efforts to reduce natural phenomena of vessel motions by adopting special devices especially for roll motions. Among many devices, inserting baffles in the inner liquid tank is very common. In this study, one investigated the vessel motions with inner sloshing tanks with baffles inside. For the numerical simulation, one employed a dynamically coupled program between boundary-element-method-based vessel motion analysis program and a particle-based computational fluid dynamics program. Comparing corresponding experimental results validated the dynamically coupled program. The validated coupled program was used to simulate vessel motions, including sloshing effects with various lengths of inner baffles. The simulation results show that not only the filling ratio of inner liquid, but also the length of clearance due to baffles influenced the vessel motions. The significant point of this study was that the natural frequency of vessel motions can be maintained irrespective of the amount of filling ratio through adjustment of the clearance. In a future study, the effects of various numbers of baffles with various clearances would be conducted to percuss the possibility of vessel motion control with inner liquid sloshing effects.

Kinematic Analysis of 100-m Women's Hurdlers at IAAF World Championships, Daegu 2011 (2011 대구세계육상선수권대회 여자 100m 허들 선수들의 운동학적 분석)

  • Ryu, Jae-Kyun;Park, Young-Jin;Ryu, Ji-Seon;Kim, Tae-Sam;Hwang, Won-Seob;Park, Sang-Kyoon;Yoon, Suk-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.541-550
    • /
    • 2011
  • The purpose of this study was to investigate the kinematic characteristics of the $5^{th}$ and $6^{th}$ hurdle clearances during the final of the 100-m hurdles event at the IAAF World Championships, Daegu 2011. To this end, the hurdling motions of the top 4 ranked female hurdlers in the competition were analyzed. A total of 12 cameras were used to record their motions, with a sampling frequency of 120 Hz. The cameras were calibrated using $11{\times}2{\times}1\;m$ control objects that covered all of the lanes ($1^{st}{\sim}8^{th}$ lanes). After analyzing all the data, we arrived at the following results. For the take-off phase, a negative relationship between the take-off time (CT) and athlete's rank was found. In addition, the average distances from the hurdle to take-off (L1) were shown to be 2.23 m and 2.17 m for the $5^{th}$ and $6^{th}$ hurdles, respectively. For the distance from the hurdle to landing (L2), Pearson ($1^{st}$ rank) and Carruthers($2^{nd}$ rank) showed inconsistent patterns whereas Harper ($3^{rd}$ rank) and Porter ($4^{th}$ rank) showed consistent patterns. All althetes revealed similar 3 steps patterns between hurdles, which consisted of a shorter $1^{st}$ step, longer $2^{nd}$ step and shorter $3^{rd}$ step.

Experimental investigation on valve rattle noise of automotive electronic-wastegate turbochargers (차량용 전자식 웨이스트 게이트 터보차져의 밸브 떨림음에 대한 실험적 고찰)

  • Park, Hoil;Eom, Sangbong;Kim, Youngkang;Hwang, Junyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.686-686
    • /
    • 2013
  • Automotive turbochargers have become common in gasoline engines as well as diesel engines. They are excellent devices to effectively increase fuel efficiency and power of the engines, but they unfortunately cause several noise problems. The noises are classified into mechanical noises induced from movement of a rotating shaft and aerodynamic noises by air flow in turbochargers. In addition to, there is a mechanical noise caused from movement of an actuator, electronically controlling a wastegate valve. It is called as valve rattle noise. The actuator is connected to a valve through a linkage. The noise occurs only if the valve is open, where the linkage is freely contact to neighbor structures without being constrained by any external forces. This condition allows impacts by the pulsation of exhaust gas, and the vibration from the impacts spreads out through turbine housing, causing the rattle noise. The noise is not in mechanical operating wastegate turbochargers because the linkage of an actuator is strongly connected by actuating force. For the electronic wastegate turbocharger, this paper proposed a test device to show the noise generating mechanism with a small vibration motor having an unbalanced shaft. It also shows how to reduce the noise - reduction of linkage clearances, inserting wave washers into a connection, and applying loose fitting in bushing embracing a valve lever to turbine housing.

  • PDF

A Study on $Na^+$ and Water Reabsorption in the Nephron Segment Beyond Proximal Tubule Measured by Lithium Clearance

  • Han, O-Soo;Goo, Yong-Sook;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.25 no.2
    • /
    • pp.189-200
    • /
    • 1991
  • During the past few years it has been proposed that lithium clearance can be used as a reliable measure for the outflow of tubular fluid from the proximal tubule. This study was aimed to characterize the inflow dependent reabsorption of Na in renal tubule beyond the proximal tubule. For this purpose, lithium clearance was used as a measure for the inflow from the proximal tubule and the changes in reabsorption fraction of Na and water were determined in rabbits. Rabbits were pretreated with hypotonic saline solutions for an hour (50 mM/L NaCl, 20 ml/hr/kg). And then a hypertonic solution of 500 mM/L NaCl (20 ml/kg) was administered intraperitoneally in conjunction with a bolus of LiCl solution (2 mM/kg, i.v.) for conditioning the $C_{Li}$ and urine flow rate. To rule out the effect of $Li^+$ on tubular functions, a bolus of NaCl solution (2 mM/kg, i.v.) was administered. Fifteen, thirty, and sixty minutes after injection of hypertonic saline arterial blood and urine samples were taken. Urinary and plasma concentrations as well as urinary output of $Li^+,\;Na^+\;and\;K^+$ were measured. From these $C_{Li},\;C_{Na}$ and the reabsorption fraction of Na and water $(Fr_{Na}\;&\;FrH_2O)$ were calculated. These results were compared with those from control groups in which the same amount of isotonic saline (145 mM/L NaCl) and of 15% dextran solution were administered in the same way as that in experimental group. Followings are the results obtained. 1) The plasma concentration of $Na^+$ in rabbits injected with hypertonic saline reached the peak value after 15 min and thereafter no significant change was observed. Hematocrit values did not show any change, while urinary excretion of $Na^+$ increased markedly during the first 15 min and decreased thereafter. These results were not affected by an injection of a small amount of LiCl. 2) The clearances of $Li^+,\;Na^+\;and\;K^+$ in rabbits injected with hypertonic saline and LiCl solution decreased. 3) In spite of the variation in $C_{Li},\;Fr_{Na}$ did not show any significant change while $FrH_2O$ increased gradually. 4) $C_{Li}$ decreased also in rabbits received isotonic saline. $Fr_{Na}$ tended to be higher than that in hypertonic saline group, while $FrH_2O\;and\;Fr_{Na}$ did not associated with the decrease in $C_{Li}$. 5) $C_{Li}$ of the rabbits received dextran solution fluctuated persistently and $Fr_{Na}\;and\;FrH_2O$ did not change in along with $C_{Li}$ although $Fr_{Na}$ had a tendency to be higher than that in hypertonic saline group. 6) From the above results it was concluded that: (a) In rabbits with normal body store of $Na^+$, the $Fr_{Na}$ of renal tubule beyond proximal tubule. calculated from $C_{Li}$ as a measure of inflow from proximal tubule is constant in spite of variations in $C_{Li}$. (b) The $FrH_2O$ calculated from $C_{Li}$ is dependent largely upon ADH rather than inflow from proximal tubule. (c) When there is a decrease in plasma $Na^+$ concentration or ineffective body fluid. $Li^+$ reabsorption may occur in the thick segnent of Henle's loop and hence the determination of $Fr_{Na}$ and $FrH_2O$ will not be easy one, but $Fr_{Na}$ is constant under the same experimental conditions.

  • PDF

Production and Evaluation of Immunoreactivity of Poly Lysine-Tagged Single Chain Fragment Variable (ScFv) Lym-1 Antibody for Direct Conjugation to Fluorescence Dye (형광 물질 직접 표지를 위한 Poly Lysine 도입 Lym-1 단일사슬 항체의 제조 및 면역반응성 평가)

  • Jung, Jae-Ho;Choi, Tae-Hyun;Woo, Kwang-Sun;Chung, Wee-Sup;Kang, Joo-Hyun;Jeong, Su-Young;Choi, Chang-Woon;Lim, Sang-Moo;Cheon, Gi-Jeong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.487-494
    • /
    • 2009
  • Purpose: Small size of recombinant scFv antibody has many advantages such as rapid blood clearances and improved targeting antibodies to tumor region. On the other hand owing to small size, number of amino group is insufficient in conjugation with chelator and fluorescence labeling. This study is to introduce poly lysine tag to the C-terminal end of scFv lym-1 sequence for fluorescence chelator conjugation. Materials and Methods: Poly lysine scFv lym-1 gene, cloned into pET-22b (+) vector, was expressed in E. coli BL21 (DE3) strain. Antibody purification was performed with Ni-NTA column and then size exclusion column chromatography. Expression and purification levels of poly lysine tagged scFv lym-1 antibody were confirmed by western blot analysis. I-124, I-125, I-131 and Tc-99m were used for radiolabeling of purified poly lysine scFv lym-1. Flow cytometry analysis of FIT( conjugated poly lysine scFv lym-1 was performed for confirmation of immunoreactivity of human Burkitt's lymphoma cells. Results: Poly lysine scFv lym-1 antibody was purified through two steps and identified as molecular weight of 48 KDa. Radiolabeling yields of I-124, I-125, I-131 and Tc-99m into poly lysine scFv lym-1 were >99%, >99%, >95% and >99%, respectively. Flow cytometry analysis of poly lysine scFv and scFv lym-1 was showed similar immunoreactivity to human Burkitt's lymphoma cells. Conclusion: Poly lysine tag was useful for the sufficient number of amino groups to scFv lym-1 antibody for chelator conjugation with minimizing loss of immunoreactivity.