• Title/Summary/Keyword: Clearance test

Search Result 303, Processing Time 0.026 seconds

Rotordynamic Performance Measurements of a Two-Pad Beam-Type Gas Foil Journal Bearing for High Speed Motors (고속 전동기용 2 패드 빔 타입 가스 포일 저널 베어링의 회전체동역학 성능 측정)

  • Jeong, Kwon Jong;Hwang, Sung Ho;Baek, Doo San;Kim, Tae Young;Kim, Tae Ho
    • Tribology and Lubricants
    • /
    • v.38 no.5
    • /
    • pp.205-212
    • /
    • 2022
  • This paper presents experimental measurements of the structural characteristics of a two-pad beam-type gas foil journal bearing and its rotordynamic performance for a high-speed motor-driven turbocompressor. The test bearing had two top foils and two beam foils, each with an arc length of ~180°. Each beam foil was etched to obtain 40 beams with six geometries of different lengths and widths. The insertion of beam foils into the bearing housing produces equivalent beam heights. The structural tests of the bearing with a non-rotating journal revealed a smaller bearing clearance and larger structural stiffness for the load-on-pad configuration than for the load-between-pads configuration. Rotordynamic performance measurements during driving tests up to 100 krpm demonstrated synchronous vibrations and subsynchronous vibrations with large amplitudes. The test was repeated after inserting the shim between the top foil and beam foil to reduce the bearing radial clearance. The reduced bearing clearance resulted in a reduction in the peak amplitude of the synchronous vibrations and an increase in the speed at which the peak amplitude occurred. In addition, the onset speed and amplitude of the subsynchronous vibrations were dramatically increased and diminished, respectively. The rotor coast-down tests at 100 krpm show that the reduction in the bearing clearance extends the time to rotor stop, thus implying an improvement in hydrodynamic pressure generation and a reduction in bearing frictional torque.

A Study on Experimental Method of Impulse turbine for OWC-type Wave Energy Conversion (파력발전용 임펄스터빈의 모형시험 기법연구)

  • LEE YOUNG-YEON;HONG SEOK-WON;HYUN BEOM-SOO
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.268-273
    • /
    • 2004
  • A study on experimental method of the model test for the impulse turbine is carried out. the wave simulator is used to reproduce the real wave condition. It controls two parameter correspond to wave height and wave frequency. The optimum design which is reported by T. Setoguchi is manufactured and tested for the validation of our test facilities. The comparison of model test show that our facilities produce little bit higher efficiency at maximum efficiency point. To increase the efficiency of turbine, the new rotor with negative tip clearance is designed and being tested.

  • PDF

Test Results of Friction Factor for Round-Hole Roughness Surfaces in Closely Spaced Channel Flow of Water

  • Ha, Tae Woong
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.10
    • /
    • pp.1849-1858
    • /
    • 2004
  • For examining friction-factor characteristics of round-hole pattern surfaces which are usually applied on damper seals, flat plate test apparatus is designed and fabricated. The measurement method of leakage and pressure distribution along round-hole pattern specimen with different hole area is described and a method for determining the Fanning friction factor is discussed. Results show that the round-hole pattern surfaces provide a much larger friction factor than smooth surface, and the friction factor vs. clearance behavior yields that the friction factor generally decreases as the clearance increases unlike the results of Nava's flat plate test. As the hole depth is decreased, the friction factor is increased, and maximum friction factor is obtained for 50% of hole area. Since the present experimental friction factor results show coincident characteristics with Moody's friction factor model, empirical friction factors for round-hole pattern surfaces are obtained by using the Moody's formula based on curve-fit of the experimental data. Results of Villasmil's 2D CFD simulation support the present experimental test result.

Not All Children with Cystic Fibrosis Have Abnormal Esophageal Neutralization during Chemical Clearance of Acid Reflux

  • Woodley, Frederick W.;Moore-Clingenpeel, Melissa;Machado, Rodrigo Strehl;Nemastil, Christopher J.;Jadcherla, Sudarshan R.;Hayes, Don Jr;Kopp, Benjamin T.;Kaul, Ajay;Di Lorenzo, Carlo;Mousa, Hayat
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.20 no.3
    • /
    • pp.153-159
    • /
    • 2017
  • Purpose: Acid neutralization during chemical clearance is significantly prolonged in children with cystic fibrosis, compared to symptomatic children without cystic fibrosis. The absence of available reference values impeded identification of abnormal findings within individual patients with and without cystic fibrosis. The present study aimed to test the hypothesis that significantly more children with cystic fibrosis have acid neutralization durations during chemical clearance that fall outside the physiological range. Methods: Published reference value for acid neutralization duration during chemical clearance (determined using combined impedance/pH monitoring) was used to assess esophageal acid neutralization efficiency during chemical clearance in 16 children with cystic fibrosis (3 to < 18 years) and 16 age-matched children without cystic fibrosis. Results: Duration of acid neutralization during chemical clearance exceeded the upper end of the physiological range in 9 of 16 (56.3%) children with and in 3 of 16 (18.8%) children without cystic fibrosis (p=0.0412). The likelihood ratio for duration indicated that children with cystic fibrosis are 2.1-times more likely to have abnormal acid neutralization during chemical clearance, and children with abnormal acid neutralization during chemical clearance are 1.5-times more likely to have cystic fibrosis. Conclusion: Significantly more (but not all) children with cystic fibrosis have abnormally prolonged esophageal clearance of acid. Children with cystic fibrosis are more likely to have abnormal acid neutralization during chemical clearance. Additional studies involving larger sample sizes are needed to address the importance of genotype, esophageal motility, composition and volume of saliva, and gastric acidity on acid neutralization efficiency in cystic fibrosis children.

STUDY ON THE CARIOGENIC FACTORS IN THE MALE KOREAN TWENTIES (20대 남성의 치아우식발생요인에 관한 연구)

  • Paik Dai-Il
    • The Journal of the Korean dental association
    • /
    • v.15 no.2
    • /
    • pp.145-151
    • /
    • 1977
  • The author performed Snyder test, estimation of salivary flow rate, salivary viscosity test, salivary buffering capacity test, M-R test, oral hygiene ability test, estimation of oral glucose clearance time and plaque reformation test in the 107 male Koreans aged form the age of 20 to 29, in order to detect and control the active cariogenic factors contributing to caries development on the individual basis. Thereafter, the data from 8 kinds of caries activity test were analysed and evaluated. The obtained results were as follows: 1. Snyder test was positive in 86.0% of total tested persons, and among those showing positive Snyder test reaction, slight caries activity was appeared in 39.1%, moderate caries activity in 23.9%, and marked caries activity in 37.0%. 2. Salivary flow rate was under the average flow amount in 53.3%. 3. Salivary buffering capacity was low in 22.4%. 5. Buffering capacity of dental plaque was high in 12.5%. 6. Oral hygiene ability was insufficient in all persons tested. 7. Oral glucose clearance time was long in 42.1%. 8. Plaque reformation rate was high in 8.4% of the 107 persons tested.

  • PDF

Triaxial Shake Table Test about Seismic Performance of Ceiling System with Gypsum Panels (석고 패널이 부착된 천장 시스템의 내진성능 평가를 위한 3축 진동실험)

  • Park, Hae-Yong;Jeon, Bub-Gyu;Kim, Jae-Bong;Gim, Min-Uk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.143-153
    • /
    • 2019
  • In this study, a full scale 3-axes shake table test for M-bar and T-bar type ceilings commonly used in the country was conducted. Through damage inspection during the test, seismic performance of ceilings according to variables, such as clearance between wall mold and ceiling as well as existence of facilities, was evaluated. A test frame consisted of square hollow section members was used for the shake table test. The experimental method was performed as a fragility test using required response spectrum described in ICC-ES AC156. In the case of architectural nonstructural component that contain ceilings, it mainly is evaluated the performance by post-test visual inspection. For the evaluation of seismic performance of ceilings, this study classified and defined damaged items for targeted ceiling system referring to illustrative damage according to nonstructural performance levels accordance with ASCE 41 and previous studies. And proposed illustrative damage items classification was utilized to compare the degree of the damage according to experimental variables. The experiment results confirmed that differences in boundary conditions due to the clearance at wall mold and the installation of facilities had a significant effect on the seismic performance of the ceiling.

Effect of All-Red Clearance Interval on Intersection Right-Angle Crashes (전적색신호가 교차로 직각충돌사고에 미치는 영향)

  • Kim, Yong-Seok;Gang, Dong-Su;Park, Jun-Tae;Lee, Su-Beom
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.1
    • /
    • pp.97-105
    • /
    • 2010
  • An All-red clearance interval(AR) has been operating with amber signal in order to avoid collision between vehicles which cannot come out of the intersections, vehicles coming in from the opposite direction, and pedestrians(bicycles) on the crosswalk during the signal conversion time at the intersections. Foreign nations have been analyzing AR's influences of traffic accidents. On the other hand, the similar research has not been conducted in the country. The objective of this paper, therefore, is to analyze the safety at the intersections with respect to the installation of AR through the hypothesis test. A before-and-after analysis has been performed for 10 intersections where applied AR. From the 95% of significance level, the results of Non-parametric Test show that the installation of AR improves a safety at the intersections. The results indicates that AR discharges vehicles passing through the intersections and control entering vehicles at the intersections.

Experimental Identification of the Damping Characteristics of a Squeeze Film Damper with Open Ends and Central Groove (열린 끝단과 중앙 홈을 갖는 스퀴즈 필름 댐퍼의 감쇠 특성에 대한 실험적 규명)

  • Nam Kyu Kim;Tae Ho Kim;Kyungdae Kang
    • Tribology and Lubricants
    • /
    • v.40 no.1
    • /
    • pp.28-37
    • /
    • 2024
  • This paper presents the development of a squeeze film damper (SFD) test rig and experimental identification of the effects of clearance, damper length, journal eccentricity ratio, excitation amplitude, oil supply pressure, and oil flow rate on the damping coefficients of a test SFD with open ends and a central groove. Test data are compared with predictions from a simple model developed for short SFDs with open ends and a central groove. The test results show a significant decrease in the damping coefficient with increasing clearance and a dramatic increase with damper length, which are in good agreement with the simple model predictions. According to the simple model, the damping coefficient is inversely proportional to the cube of the clearance and directly proportional to the cube of the length. An increase in the journal eccentricity ratio results in a dramatic increase in the damping coefficient by as much as 15 times that of the concentric case, particularly at low excitation frequencies. By contrast, the measured damping coefficient remains almost constant with changes in the excitation amplitude and supply pressure, which are not major factors in the damper design. In general, the test data agree well with the simple model predictions, excluding cases that show increases in the SFD length and journal eccentricity, which indicate significant dependency on the excitation frequency.

Study on Development of High Performance Evaporator for Automotive Air Conditioner (자동차 공조용 증발기의 고성능화에 관한 연구)

  • Kang, J.K.;Kim, K.H.;Park, T.Y.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.73-80
    • /
    • 1995
  • The object of the present study is to develop a high performance evaporator for automotive air conditioner. The experiment has been conducted on evaporative heat transfer coefficient inside a plate type heat exchanger with a sharp 180-degree turn flow. The test plates have different formed surface, cross-ribbed channel and elliptical-ribbed channel. Also experimental study has been performed to determine optimal design in elliptical-ribbed plate heat exchanger with different turn clearance. In addition to the above experiments, refrigerant behavior and surface temperature distribution in the plate heat exchanger were observed using color thermoviewer(infrared thermometer). In this experiment, working fluid was used R-12 and test conditions were as follows : (1) saturation pressure of $2.116kg/cm^2$, (2) mass fluxes of 40 to $70kg/m^2s$, (3) heat fluxes of 4,500 to $7,300W/m^2$, (4) inlet quality of 0.1 to 0.7. The results indicated that the evaporative heat transfer coefficient of an elliptical-ribbed plate heat exchanger was higher than that of cross-ribbed plate heat exchanger. Also optimal turn clearance in an elliptical-ribbed plate heat exchanger was determined.

  • PDF

A Study on the Boiling Heat Transfer of Heat Surface with Fin Array to R-113 (흰열이 있는 전열면의 R-113에서의 비등열전달에 관한 연구)

  • 조시기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.440-447
    • /
    • 2001
  • This study investigate experimentally the effect of in height, thickness, and clearance on the boiling heat transfer. The heat surfaces having copper fin array is tested for pool boiling. The gas-liquid exchange interference is investigated based on fin array clearance. These test results can be applied to the design of tube bundle system. The fin height of 2 mm is found to be effective. Effects of heat transfer promotion reaches the highest level when the fin clearance is 0.5mm. Also, heat flux is increased when the fin thickness is smaller. But0.2 mm fin thickness is highly recommended.

  • PDF