Stepwise Hull Form Design of DWT 75,000 Product Oil Carrier (순차적 설계기법에 의한 DWT 75,000 정유운반선의 선형설계)

  • Park, Yeon Seok;Bak, Sera;Jeong, Yohan;Choi, Jung-Kyu;Yoo, Jaehoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.6
    • /
    • pp.456-464
    • /
    • 2016
  • To design the modified hull form with relatively unfavorable dimensions and constraints than the parent ship the stepwise design was applied. In each design step the resistance characteristics was estimated by numerical calculations using CFD programs as Wavis 1.4, Wavis 2.1 and Fluent 12.1. The wave profiles along hull surface by potential flow calculations were investigated to improve wave resistance by modifying the bow shapes. To improve the stern shapes with a point of viscous form resistance the pressure distributions on hull surface and the limiting streamlines are investigated by viscous flow calculations. The design objectives such as shortening the LBP, enlarging the propeller tip clearance, moving forward of the LCB location and increasing the displacement were applied by stepwise to develop the new hull form of DWT 75,000 product oil carrier. Finally a new hull form was developed without the resistance performance loss compared with the parent ship.

A Study of Renogram in Korean Hemorrhagic Fever (한국형(韓國型) 출혈열(出血熱)에서의 Renogram에 대(對)한 연구(硏究))

  • Choi, Tae-Kyu;Lee, Jung-Sang;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.8 no.1_2
    • /
    • pp.13-24
    • /
    • 1974
  • The patterns of renogram in patients with Korean hemorrhagic fever were evaluated with clinical course and renal hemodynamic changes in various clinical stages. The renal plasma flow was measured by hippuran blood clearance using $^{131}I$-ortho-iodohippurate and hippuran renogram was analysed by means of quantitative and qualitative methods in 26 patients of Korean hemorr hagic fever. The results obtained with this study were as follows; 1. During the oliguric phase of Korean hemorrhagic fever, the renogram showed non-functioning (flat) or obstructive pattern. The group of patients with non-functioning pattern of renogram had more severe impairement of renal function and grave prognosis than the group with obstructive pattern of renogram. 2. During the diuretic phase, the renogram showed obstructive or dysfunction or normal pattern, which was related with the recovery of renal function. Obstruction pattern of renogram was observed till the 2nd week of diuretic phase. Normal pattern of renogram began to appear by the 2nd week of diuretic phase. 3. During the convalescent phase of Korean hemorrhagic fever, 40% of patients showed dysfunnction pattern of renogram, and the recovery of abnormal renogram in Korean hemorrhagic fever was more delayed than the recovery of clinical features and laboratory findings. 4. The renogram showed normal pattern 6 months after onset of Korean hemorrhagic fever in all cases. 5. There was significant correlationship between the pattern of renogram and the decreace of renal plasma flow in the patients with Korean hemorrhagic fever. The decreace of renal plasma flow was maked in the patients with non-functioning pattern of renogram and was least in the patients with dysfunction pattern of renogram. All above results suggested that the renogram reflects the effective renal plasma flow and degree of renal impairement, and the renogram may be one of the important indexes which could give us a more precise prognosis in Korean hemorrhagic fever.

  • PDF

Simulations of fluidelastic forces and fretting wear in U-bend tube bundles of steam generators: Effect of tube-support conditions

  • Hassan, Marwan;Mohany, Atef
    • Wind and Structures
    • /
    • v.23 no.2
    • /
    • pp.157-169
    • /
    • 2016
  • The structural integrity of tube bundles represents a major concern when dealing with high risk industries, such as nuclear steam generators, where the rupture of a tube or tubes will lead to the undesired mixing of the primary and secondary fluids. Flow-induced vibration is one of the major concerns that could compromise the structural integrity. The vibration is caused by fluid flow excitation. While there are several excitation mechanisms that could contribute to these vibrations, fluidelastic instability is generally regarded as the most severe. When this mechanism prevails, it could cause serious damage to tube arrays in a very short period of time. The tubes are therefore stiffened by means of supports to avoid these vibrations. To accommodate the thermal expansion of the tube, as well as to facilitate the installation of these tube bundles, clearances are allowed between the tubes and their supports. Progressive tube wear and chemical cleaning gradually increases the clearances between the tubes and their supports, which can lead to more frequent and severe tube/support impact and rubbing. These increased impacts can lead to tube damage due to fatigue and/or wear at the support locations. This paper presents simulations of a loosely supported multi-span U-bend tube subjected to turbulence and fluidelastic instability forces. The mathematical model for the loosely-supported tubes and the fluidelastic instability model is presented. The model is then utilized to simulate the nonlinear response of a U-bend tube with flat bar supports subjected to cross-flow. The effect of the support clearance as well as the support offset are investigated. Special attention is given to the tube/support interaction parameters that affect wear, such as impact and normal work rate.

Effect of Probenecid on Urate Excretion in the Cat Kidney

  • Jung, Dong-Keun;Kim, Yong-Keun;Jung, Jin-Sup;Lee, Sang-Ho
    • The Korean Journal of Physiology
    • /
    • v.25 no.1
    • /
    • pp.37-48
    • /
    • 1991
  • The characteristics of probenecid effect on renal urate excretion in the cat were studied by clearance method and compared with those in the rabbit. In the cat GFR was $3.03{\pm}0.09\;ml/min{\cdot}kg$, and endogenous plasma urate concentration was $1.12{\pm}0.57\;{\mu}g/ml$, which is less than that in the rabbit $(3.33{\pm}0.46\;{\mu}g/ml)$. In the rabbit, $FE_{ur}$ was $1.76{\pm}0.08$ and net urate secretion was observed, while, in the cat $FE_{ur}$ was $0.70{\pm}0.02$ and net reabsorption was observed. In the cat $FE_{ur}$ was dependent on urine flow and independent of plasma urate concentration. In the rabbit $FE_{ur}$ was suppressed by infusion of probenecid $(30\;mg/kg\;-0.6\;mg/kg{\cdot}min)$ into femoral vein. In the cat the same dose of probenecid increased $FE_{ur}$ and concomitantly increased urine flow. Thus, an increase in $FE_{ur}$ by probenecid could be considered to be resulted from a change in urine flow. In the cat infusion of probenecid $(2.5\;mg/kg{\cdot}min)$ into renal artery markedly suppressed $FE_{P\;A\;H}$, but the effects on $FE_{ur}$ and urine flow were similar to those when probenecid was infused into femoral vein. These results indicate that in the cat kidney urate filtered through glomerulus is reabsorbed by a probenecid-insensitive mechanism with no evidence for net secretion.

  • PDF

An Experimental Study on Heat Transfer Augmentation by Square Rod in Impinging Air Jet System(Effect of Rod Width) (사각로드를 이용한 충돌분류계의 열전달증진에 관한 연구(로드폭의 영향))

  • Kum, Seong-Min;Lee, Yong-Hwa;Seo, Jeong-Yun
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.127-140
    • /
    • 1995
  • This experimental study was carried out to examine the heat transfer characteristics of a 2-dimensional impinging air jet on a flat plate with a set of square rods. The objectives of the study were to investigate the flow and heat transfer characteristics caused by the square rods. Experiment was carried out first without using the rods to establish the baseline heat transfer performance. Then, rods of different widths and clearances were installed to cause the turbulence on the fluid flow. When rods are installed in front of the plate, the acceleration of the flow and the turbulence generation due to the rods and reattachment of the flow seem to contribute to the observed heat transfer augmentation and the heat transfer augmentation increases as the clearance decreases. With wider individual rod the heat transfer coefficient is higher, which is due to the increased acceleration and development of the eddies just before the rods.

  • PDF

Effect of Atrial Natriuretic Factor on the Renal Function and Renin Release in Unanesthetized Rabbit (무마취 가토 신장기능에 미치는 Atrial Natriuretic Factor의 영향)

  • Lee, June-K.;Cho, Kyung-W.
    • The Korean Journal of Physiology
    • /
    • v.20 no.1
    • /
    • pp.103-124
    • /
    • 1986
  • Since it has been suggested that atrial receptor may be involved in the mechanism of extracellular volume regulation, it was shown that the granularity of atrial cardiocytes can be changed by water and salt depletion, and that an extract of cardiac atrial tissue, when injected intravenously into anesthetized rats, was shown to cause a large and rapid increase in renal excretion of sodium. Various natriuretic peptides were isolated and synthetized, and the effects were investigated by many workers. Most studies, however, have been carried out under anesthesia and there have teen some controversies over direct effect of the factor on the renal function. Therefore, it was attempted in this study to access the effects of an atrial extract and a synthetic natriuretic factor in unanesthetized rabbits. Intrarenal arterial infusion of atrial extract caused a rapid increase of urinary volume and excretion of sodium. Glomerular filtration rate and renal plasma flow were both increased with no change in filtration fraction. The ventricular extract produced no change in urinary excretion of electrolytes, nor in renal hemodynamics. Intrarenal infusion of synthetic atrial natriuretic factor caused increases of renal excretory rate of sodium, chloride and potassium, and $FE_{Na}$. Glomerular filtration rate, renal plasma flow increased. And free water clearance also increased. Accentuated excretory function correlated well with increased glomerular filtration rate and renal plasma flow during infusion and for 10 minutes following the cessation of the infusion. Renin secretion rate decreased during constant infusion of atrial natriuretic factor. However, no correlation was found with the changes in glomerular filtration rate, renal plasma flow, or urinary excretion of sodium. These results suggest that atrial extract or atrial natriuretic factor induces changes in renal hemodynamics, as in excretion of electrolytes either indirectly through hemodynamic changes or directly by inhibiting tubular reabsorption. At the same time, renin secretory function is affected by the factor possibly through an unknown mechanism.

  • PDF

Performance Analysis of a Vacuum-Compatible Air Bearing (진공용 공기베어링의 성능해석)

  • Khim, Gyung-Ho;Park, Chun-Hong;Lee, Hu-Sang;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.10
    • /
    • pp.103-112
    • /
    • 2006
  • This paper describes a theoretical analysis and experimental verification on the performances of a vacuum-compatible air bearing, which is designed with a cascaded exhaust scheme to minimize the air leakage in a vacuum environment. The design of the vacuum-compatible air bearing equipped with the differential exhaust system requires great care because several design parameters, such as the number of exhaust stages, diameter of exhaust tube, pumping speed of a vacuum pump, and bearing clearance greatly influence the air leakage and thus degree of vacuum. In this study, a performance analysis method was proposed to estimate the performances of the air bearing, such as load capacity, stiffness, and air leakage. Results indicate that the load capacity and stiffness of the air bearing was improved as its boundary pressure, which was determined by the $1^{st}$ exhaust method, was lowered, and the dominant factors on the chamber's degree of vacuum were the number of exhaust stages, exhaust tube diameter and bearing clearance. A vacuum chamber and air bearing stage using porous pad were fabricated to verify the theoretical analysis. The results demonstrate that chamber pressure up to an order of $10^{-3}$ Pa was achieved with the air bearing stage operating inside the chamber, and this analysis method was valid by comparing predicted values with experimental data, for the mass flow rates from the porous pad, and pressures at each exhaust port and chamber, respectively.

Role of Water Current in the CROM Operation for the Water Quality Improvement of Eutrophic Reservoir (부영양 저수지의 수질개선을 위한 CROM 운영 및 유속의 영향)

  • Lee, Ju-Hwan;Hwang, Soon-Jin;Kim, Baik-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.518-524
    • /
    • 2010
  • Continuous removal of organic matters (CROM) using freshwater bivalve Anodonta woodiana was operated to evaluate the effect of water current on the water quality improvement (clearance) of eutrophic lake. The CROM system comprised three treatment steps such as flow control, treatment and analysis, and operated at the two different currents ($24L\;h^{-1}$ and $48L\;h^{-1}$) with mussels at density of $312.5indiv.\;m^{-2}$ for 12 consecutive days. Water quality including suspended solids (SS) and chlorophyll-a (Chl-a) was daily measured at the same time. Results indicate that although both the system strongly decreased the concentration of SS and chl-a, a slow CROM system was more effective to diminish the SS contents than a fast CROM system; 82% and 66%, respectively (ANOVA, P<0.0001). Clearance rates, based on chl-a, were also significantly higher in a slow system than a fast system (ANOVA, P<0.0001), although the mussel mortality was conversely. In both systems, there showed a remarkable excretion of dissolved inorganic nutrients (i.e. $NH_3-N$ and $PO_4-P$), while a slow CROM system was higher than a fast system, significantly (ANOVA, P<0.0001). Therefore, it may suggest that a slow current CROM system is more suitable to maximize the efficacy of water quality improvement, but further study is needed to diminish the mortality of mussel and to reuse the nutrient released during the operation.

Effects of Diabetes Mellitus on the Disposition of Tofacitinib, a Janus Kinase Inhibitor, in Rats

  • Gwak, Eun Hye;Yoo, Hee Young;Kim, So Hee
    • Biomolecules & Therapeutics
    • /
    • v.28 no.4
    • /
    • pp.361-369
    • /
    • 2020
  • Tofacitinib, a Janus kinase inhibitor, was developed for the treatment of rheumatoid arthritis. Recently, it has been associated with an increased change in arthritis development in patients with diabetes. Herein, we evaluated the pharmacokinetics of tofacitinib after intravenous (10 mg/kg) and oral (20 mg/kg) administration to rats with streptozotocin-induced diabetes mellitus and control rats. Following intravenous administration of tofacitinib to rats with streptozotocin-induced diabetes mellitus, area under the plasma concentration-time curve from time zero to infinity of tofacitinib was significantly smaller (33.6%) than that of control rats. This might be due to the faster hepatic intrinsic clearance (112%) caused by an increase in the hepatic cytochrome P450 (CYP) 3A1(23) and the faster hepatic blood flow rate in rats with streptozotocin-induced diabetes mellitus than in control rats. Following oral administration, area under the plasma concentration-time curve from time zero to infinity of tofacitinib was also significantly smaller (55.5%) in rats with streptozotocin-induced diabetes mellitus than that in control rats. This might be due to decreased absorption caused by the higher expression of P-glycoprotein and the faster intestinal metabolism caused by the higher expression of intestinal CYP3A1(23), which resulted in the decreased bioavailability of tofacitinib (33.0%) in rats with streptozotocin-induced diabetes mellitus. In summary, our findings indicate that diabetes mellitus affects the absorption and metabolism of tofacitinib, causing faster metabolism and decreased intestinal absorption in rats with streptozotocin-induced diabetes mellitus.

Effect of Heat Transfer Augmentation by Square Rod Array in Impinging Air Jet System(Heat Transfer Characteristic of Potential Core Region) (충돌공기분류계에서 사각 ROD에 의한 전열증진 효과(포텐셜코어영역에서의 전열특성))

  • Kum, Seong-Min;Oh, Soo-Cheol;Seo, Jeong-Yoon
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.85-94
    • /
    • 1995
  • This research has been proceeded over the potential core region(H/B=2) of two-dimensional impinging air jet sytem, in which square rods(width of 6 mm) has been set up in front of heating surface in order to increase heat transfer. The objective of this research was to investigate the characteristics of heat transfer and air flow, in eases of the clearance from rods to heating surface(C=1, 2, 4, 6 mm) and the pitch between each rods(P=30, 40, 50 mm) changed. And this research compared the above with the experimentation without rods. As result, heat transfer performance was best under the condition of C=1mm, in case clearance changed, and there was no serious difference in the effect of heat transfer augmentation in the case of pitch of rods changed.

  • PDF