• 제목/요약/키워드: Clearance flow

검색결과 480건 처리시간 0.026초

회전용적형 기어펌프의 유체-구조연동 전산해석 (FLUID-STRUCTURE INTERACTION ANALYSIS OF EXTERNAL GEAR PUMP)

  • 이중호;김태구;이상욱
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.83-85
    • /
    • 2010
  • A hydraulic gear pump is widely used in many industrial applications to provide both high pressure and high flow rate by physical displacement of finite volume of fluid with each revolution. In this study, two dimensional fluid-structure interaction simulation of gear pump flow was carried out to examine detailed complex flow patterns and structural stress distribution on rotors by using a commercial software ADINA. The effect of rotor clearance size on the flow characteristics, specially the temporal variation of velocity and pressure field, which is a main source of flow noise, also was investigated.

  • PDF

축류송풍기의 삼차원 유동장 해석 (Three-dimensional analysis of the flow through an axial-flow fan)

  • 김광용;김정엽;정덕수
    • 대한기계학회논문집B
    • /
    • 제21권4호
    • /
    • pp.541-550
    • /
    • 1997
  • Computational and experimental investigations on the three-dimensional flowfield through an automotive cooling fan are carried out in this work. Steady, incompressible, three-dimensional, turbulent flow through a rotating axial-flow fan is analyzed with Reynolds averaged Navier-Stokes equations and standard k-.epsilon. turbulence model. The governing equations are discretized with finite-volume approximations in non-orthogonal curvilinear coordinates. Computational static pressures on the casing wall agree well with the experimental data which are measured in this work. And, they are sensitive to the change of tip clearance. The flowfield is not significantly affected by the thickness of the blade. The k-.omega. model gives the static pressure rise on the casing wall which is similar to that with the k-.epsilon. model.

Flow-induced instability and nonlinear dynamics of a tube array considering the effect of a clearance gap

  • Lai, Jiang;Sun, Lei;Li, Pengzhou
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1650-1657
    • /
    • 2019
  • Fluidelastic instability and nonlinear dynamics of tube bundles is a key issue in a steam generator. Especially, once the post-instability motion of the tube becomes larger than the clearance gap to other tubes, effective contact or impact between the tubes under consideration and the other tube inevitable. There is seldom theoretical analysis to the nonlinear dynamic characteristics of a tube array in two-phase flow. In this paper, experimental and numerical studies were utilized to obtain the critical velocity of the flow-induced instability of a rotated triangular tube array. The calculation results agreed well with the experimental data. To explore the post-instability dynamics of the tube array system, a Runge-Kutta scheme was used to solve the nonlinear governing equations of tube motion. The numerical results indicated that, when the flow pitch velocity is larger than the critical velocity, the tube array system is undergoing a limit cycle motion, and the dynamic characteristics of the tube array are almost similar for different void fractions.

클리어런스가 없는 초고압 회전용적형 헬리컬기어 펌프의 유동해석에 관한 연구 (A Study on Fluid Flow Analysis of High Pressure Positive Displacement Pump without Clearance)

  • 민세홍;김호철
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.33-38
    • /
    • 2015
  • 고압과 정량 흡상을 목적으로 클리어런스가 없는 초고압 회전용적형 헬리컬기어 펌프의 개발을 진행하였다. 펌프의 내부 압력과 토출 유속을 검증하기 위해 CFD 해석을 수행하였다. 이에 따라 FVM 기법으로 유동해석을 수행하였는데 클리어런스가 없는 완전히 밀폐된 형태의 FVM 유동해석은 격자가 연속하게 구성되지 않아 유체영역이 분리되어 정상적인 결과를 얻어낼 수 없었다. 이러한 문제로 격자 구성이 필요치 않은 MPS 기법으로 유동해석을 수행하였고, MPS 유동해석을 통해 펌프의 내부 압력과 토출 유속을 확인할 수 있었다. 로터의 회전속도 1,000 rpm에서 펌프 내부의 압력은 최소일 때 19.5 bar, 최대일 때 44.6 bar이고, 평균 압력은 33.9 bar로 확인되었다. 토출 유속은 최소일 때 64.5 m/s, 최대일 때 84.8 m/s이고, 평균 유속은 76.1 m/s로 확인되었다. 본 연구를 통해 클리어런스가 없는 해석 모델의 유동해석은 FVM 기법보다는 MPS 기법이 더 적합하였음을 확인할 수 있었다. 또한 초고압 회전 용적형 헬리컬기어 펌프의 압력의 변화에 따른 유속과의 관계를 본 연구를 통해 규명할 수 있었다.

고속 회전하는 원판형 드래그펌프 회전익과 고정익 사이 간극이 배기 성능에 미치는 영향 (Effect of Clearance between a Rotor and Stator of a Disk-Type Drag Pump on the Pumping Performance)

  • 권명근;이수용;황영규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1640-1645
    • /
    • 2004
  • The pumping characteristics of a single-stage disk-type drag pump ( DTDP ) are calculated,for the variation of the vertical clearance between a rotor and stator and of the radial clearance between a rotor and casing wall, by the three-dimensional direct simulation Monte Carlo (DSMC)method. The gas flow mainly belongs to the molecular transition flow region. Spiral channels of a DTDP are cut on the both the upper and lower sides of a rotating disk, but the stationary disks are planar. As a consequence of results, the vertical and radial clearances have a significant effect on the pumping performance. Experiments are performed under the outlet pressure range of 0.4 $^{\sim}$ 533 Pa. When the numerical results are compared to the experimental data, the numerical results agree well qualitatively.

  • PDF

원판형 드래그펌프 회전자와 고정자 사이의 간극이 성능에 미치는 영향 (Effect of Vertical Clearance Between a Rotor and Stater of a Disk-Type Drag Pump on the Performance)

  • 권명근;황영규
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1501-1510
    • /
    • 2004
  • The pumping characteristics of a single-stage disk-type drag pump (DTDP) are calculated for the variation of the vertical clearance between a rotor and stator by the three-dimensional direct simulation Monte Carlo (DSMC) method. The gas flow mainly belongs to the molecular transition flow region. Spiral channels of a DTDP are cut on the both the upper and lower sides of a rotating disk, but a stationary disk is planar. The interaction between molecules is described by the variable hard-sphere model. The no time counter method is used as a collision sampling technique. The vertical clearance has a significant effect on the pumping performance. Experiments are performed under the outlet pressure range of 0.4∼533 Pa. When the numerical results are compared with the experimental data, the numerical results agree well quantitatively

충돌판(衝突板) 근방(近傍)에 배열(配列)된 2차원(次元) rod가 충돌분류(衝突噴流) 열전달(熱傳達)에 미치는 영향(影響) (1) : 전열면(傳熱面)-rod간(間)의 간극효과(間隙效果) (Heat Transfer Augmentation on Flat Plate with Two- Dimensional Rods in Impinging Air Jet System (1) : Effect of Clearance between flat plate and rod)

  • 이용화;서정윤
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.73-81
    • /
    • 1989
  • The purpose of this study is augmentation of heat transfer without additional power in a rectangular impinging air jet. As a method of passive heat transfer augmentation in a two-dimensional air jet, heat transfer surface of flat plate with rods is used. This study, particularly in the wall jet rigeon, investigates the effect of the clearance between the flat plate and rod. Mechanism of heat transfer enhancement is investigated by measuring the local heat transfer coefficient. It is concluded that the superposition of the effects of flow accelerlation through the clearance between the flat plate and the rod, and reattachment of the flow was the cause of the excellent performance. The overall heat transfer rate of flat plate with rods is about 1.5 times larger than that of flat plate without rods.

  • PDF

개의 신장기능에 미치는 목통 수성 엑기스의 영향 (An Influence of Water Extract of Akebiae Lignum on Renal Function of the Dog)

  • 이은화
    • 약학회지
    • /
    • 제22권4호
    • /
    • pp.207-214
    • /
    • 1978
  • Influence of Akebiae Lignum on the renal function of the dog was observed with water-extract, utilizing clearance technique. Akebiae Lignum water-extract (AWE) given intravenously in does of 3.0mg/kg and 30.0mg/kg elicited a marked antidiuretic effect and produced a distinguished decrease of glomerular filtration rate and renal plasma flow as reduction of sodium and potassium excretion in urine, positive free water clearance and osmolar clearance. AWE infused into a renal artery in doses of 0.03mg/kg/min and 0.1mg/kg/min exhibited identical results to the intravenous action confined only to the infused kidney. These results suggest that AWE elicits antidiuresis in the dog by decreasing glomerulor filtration and renal plasma flow, which are caused by the constriction of vas afferens in the glomeruli.

  • PDF

인공신장 투석기에서 Ultrafiltration이 Clearance에 미치는 영향 (Effect of Ultrafiltration on the Clearance of Artificial Kidney Dialyzers)

  • 장호남;김진곤;박한철
    • 대한의용생체공학회:의공학회지
    • /
    • 제3권1호
    • /
    • pp.3-8
    • /
    • 1982
  • Solute transfer in artificial kidney dialyzers was analyzed using Kedem-Katcha- Isky's description on membrane transport. Mass transfer coefficient, K was deduced from the diffusive clearance of commercial hemodialyzers. It can to seen that Kd increases with the increase of blood flow rate, which means that there is substantial resistance in the blood phase for solute transport. Total clearance was estimated with the Werynski's formula. The increase in total clearance due to ultrafiltration was most significant for middle molecules like vitamin Bla, however that for smaller molecules such as urea and creatinine was minimal.

  • PDF

No Effect of Diltiazem on the Hepatic Clearance of Indocyanine Green in the Rats

  • Joo, Eun-Hee;Lee, Yong-Bok
    • Archives of Pharmacal Research
    • /
    • 제21권4호
    • /
    • pp.411-417
    • /
    • 1998
  • In order to investigate the effect of the pretreatment with various doses of diltiazem (DTZ) on the pharmacokinetics of indocyanine green (ICG) at steady state, especially the hepatic blood clearance due to the change of hepatic blood flow, the following experiments were carried out with ICG, a hepatic function test marker, not metabolized in liver and only excreted in bile. The intravenous bolus injection ($3,780\mu\textrm{g}$/kg) and the constant-rate infusion ($10,100\mu\textrm{g}$/kg/hr) of ICG into the left femoral vein were made in order to check the steady-state plasma concentration ($C_{ss} of $10\mu\textrm{g}$/ml) of ICG at 20, 25 and 30 min. Following a 90-min washout period, the intravenous bolus injection (108, 430, 860 and $1,720\mu\textrm{g}$/kg) and the constant-rate infusion (108, 433, 866 and $1,730\mu\textrm{g}$/kg/hr) of DTZ into the right femoral vein were made and the achievement of the steady-state plasma levels ($C_{ss} of 50, 200, 400 and 800 ng/ml) of DTZ were conformed at 60, 70 and 80 min. During the steady state of DTZ, the intravenous bolus injection ($3,780\mu\textrm{g}$/kg) and the constant-rate infusion ($10,200\mu\textrm{g}$/kg/hr) of ICG into the left femoral vein were made and also the steady-state plasma concentration of ICG was checked at 20, 25 and 30 min. The plasma concentrations of DTZ and ICG were determined using a high performance liquid chromatographic technique. At the steady state, the hepatic blood clearance of ICG was obtained from the plasma concentration and blood-to-plasma concentration ratio ($R_B$) of ICG. The pretreatment with various doses of DTZ did not influence the plasma concentrations, $R_B$ and plasma free fraction ($f_p$) of ICG. So the hepatic blood clearance of ICG was independent of concentration of DTZ. The hepatic blood clearance of ICG could be affected by both hepatic bood flow and hepatic intrinsic clearance. But there was no change of the hepatic blood clearance of ICG between the control and the DTZ-pretreated rats in this study. So it may be suggested that DTZ does not influence hepatic blood flow.

  • PDF