• 제목/요약/키워드: Cleaning Test

검색결과 393건 처리시간 0.026초

근관와동형태에 따른 근관치료된 하악절치의 파절강도 (THE INFLUENCE OF DIFFERENT ACCESS CAVITY DESIGNS ON THE FRACTURE STRENGTH IN ENDODONTICALLY TREATED MANDIBULAR ANTERIOR TEETH)

  • 이영균;신혜진;박세희;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제29권6호
    • /
    • pp.515-519
    • /
    • 2004
  • Straight access cavity design allows the operator to locate all canals, helps in proper cleaning and shaping, ultimately facilitates the obturation of the canal system. However, change in the fracture strength according to the access cavity designs was not clearly demonstrated yet. The purpose of this study was to determine the influence of different access cavity designs on the fracture strength in endodontically treated mandibular anterior teeth. Recently extracted mandibular anterior teeth that have no caries, cervical abrasion, and fracture were divided into three groups (Group 1 : conventional lingual access cavity, Group 2 : straight access cavity, Group 3 : extended straight access cavity) according to the cavity designs. After conventional endodontic treatment, cavities were filled with resin core material. Compressive loads parallel to the long axis of the teeth were applied at a crosshead speed of 2mm/min until the fracture occurred. The fracture strength analyzed with ANOV A and the Scheffe test at the 95% confidence level. The results of this study were as follows: 1. The mean fracture strength decrease in following sequence Group 1 (4558.90{\;}\pm{\;}77.40{\;}N$), Group 2 ($494.07{\;}\pm{\;}123.98{\;}N) and Group 3 ($267.33{\;}\pm{\;}27.02{\;}N). 2. There was significant difference between Group 3 and other groups (P = 0.00). Considering advantage of direct access to apical third and results of this study, straight access cavity is recommended for access cavity form of the mandibular anterior teeth.

설문조사를 통한 우리나라 연안복합어선의 조업 실태 (Operating status of Korean coastal composite fishing boats by the questionnaire survey)

  • 황보규;장호영;김민선
    • 수산해양기술연구
    • /
    • 제54권4호
    • /
    • pp.324-332
    • /
    • 2018
  • We conducted a questionnaire survey to analyze the current status of the coastal composite fisheries, as well as the improvement point in designing a new type coastal composite fishing boat suitable for Korean fishing environments from April to August 2017. The questionnaire composed of 20 questions about the features of the coastal composite fishing boat and fishing work. The survey sites were selected to cover all parts of the country by considering the geographical position. The significance testing for the response results was accessed by ${\chi}^2$ test and ANOVA. The results revealed that more than half (59.1%) of the fishermen operated one day per voyage and operating alone topped with 22.5% in the number of crews, followed by 2 persons (20.3%) and 5 persons (22.1%). The navigation devices had a high rate of installation and GPS plotter ranked first in the devices. In addition, fish finder ranked first in fishing equipment, followed by net hauler. The most inconvenient work that they felt during the fishing operation was fish handing at 49.8% and other general fishing works like setting and hauling line, deck cleaning accounted for about 25%. The hardest work was the accident by ropes wrapped around propeller and the engine trouble came in second. The most inconvenient facilities to the present design of fishing boat was wheelhouse (76.7%), followed by fish hold (38.5%), and deck (35.1%). Furthermore, inconvenient points related to the movement of fishing gear, noise and vibration of engine, slippery deck and small fish hold exceeded 50%.

Preparation of highly hydrophobic PVDF hollow fiber composite membrane with lotus leaf-like surface and its desalination properties

  • Li, Hongbin;Zi, Xingchen;Shi, Wenying;Qin, Longwei;Zhang, Haixia;Qin, Xiaohong
    • Membrane and Water Treatment
    • /
    • 제10권4호
    • /
    • pp.287-298
    • /
    • 2019
  • Lotus leaf has a special dual micro and nano surface structure which gives its highly hydrophobic surface characteristics and so-called self cleaning effect. In order to endow PVDF hollow fiber membrane with this special structure and improve the hydrophobicity of membrane surface, PVDF hollow fiber composite membranes was obtained through the immersion coating of poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) dilute solution on the outside surface of PVDF support membrane. The prepared PVDF composite membranes were used in the vacuum membrane distillation (VMD) for the desalination. The effects of PVDF-HFP dilute solution concentration in the dope solution and coating time on VMD separation performance was studied. Membranes were characterized by SEM, WCA measurement, porosity, and liquid entry pressure of water. VMD test was carried out using $35g{\cdot}L^{-1}$ NaCl aqueous solution as the feed solution at feed temperature of $30^{\circ}C$ and the permeate pressure of 31.3 kPa. The vapour flux reached a maximum when PVDF-HFP concentration in the dilute solution was 5 wt% and the coating time was kept in the range of 10-60 s. This was attributed to the well configuration of micro-nano rods which was similar with the dual micro-nano structure on the lotus leaf. Compared with the original PVDF membrane, the salt rejection can be well maintained which was greater than 99.99 % meanwhile permeation water conductivity was kept at a low value of $7-9{\mu}S{\cdot}cm^{-1}$ during the continuous testing for 360 h.

비압축성 유동해석에 기초한 대면적 표면처리용 브라스팅 노즐 설계 및 실험적 검증 (Design and Experimental Verification of Blasting Nozzle for Wide Area Surface Treatment based on Incompressible Flow Analysis)

  • 김태형;곽준구;이세창;이상규;이승호
    • 에너지공학
    • /
    • 제28권1호
    • /
    • pp.49-56
    • /
    • 2019
  • 본 연구에서는 발전소에서 사용되는 부품의 넓은 표면을 세정하기 위한 브라스팅 노즐을 비압축성 유동해석에 기초하여 설계하였다. 설계된 노즐의 출구측 단면은 광폭의 직선 모양이다. 설계 후 3차원 프린팅으로 노즐 시제품을 제작하였고 이를 브라스팅 머신에 장착 후 세정 성능실험을 수행하였다. 해석 후 얻은 광폭 크기와 실험 후 시편 표면에서 얻은 세정된 광폭 크기가 거의 같았다. 이로부터 대면적 표면처리를 위한 브라스팅 노즐의 설계가 유효함을 확인하였다.

Flip Chip Non-wet 개선 및 신뢰성 향상을 위한 Low Residue Flux 구현 방안 연구 (A Study on Low Residue Flux for Improving Flip Chip Non-wet and Reliability)

  • 이현숙;김민석;김태훈;문기일
    • 마이크로전자및패키징학회지
    • /
    • 제28권2호
    • /
    • pp.45-50
    • /
    • 2021
  • Flip chip 제품의 난이도 증가에 따라 solder wetting 및 신뢰성 관점에서 강점을 갖는 flux 소재에 대한 관심이 높아지고 있다. 지용성 flux의 경우 별도의 세정 공정이 없기 때문에 공정 효율화 측면에서 유리하나, 리플로우 공정이후 반응을 마친 잔여물이 잔존하게 되는 경우 Cu migration 및 delamination을 발생시킬 수 있다. 본 연구에서는 저잔사 flux 구현을 위해 신규 resin에 적합한 solvent 및 activator를 변경 하였으며, package 환경에서 non-wet 및 신뢰성 개선 유무를 확인하였다. 저장 안정성 평가를 통해 신규 소재에 대한 안정성을 확보하였으며, boiling point가 상이한 solvent와 activator 2종 적용 및 activator 함량 증대를 통해 non-wet 미 발생 flux 소재를 확보하였다. 해당 소재에 대한 신뢰성 검증 이후 평면 분석 결과 flux residue 기인성 delamination 현상은 발견되지 않았으며, 이를 통해 저잔사 flux에 대한 최종 조성을 확보하였다.

아동·청소년 학생치과주치의 사업의 문제점 및 개선방안 (Problems and improvements of a child·adolescent dental care service)

  • 곽선희;신보미;신선정;이효진;배수명
    • 한국치위생학회지
    • /
    • 제21권4호
    • /
    • pp.441-453
    • /
    • 2021
  • Objectives: This study identified problems and improvements in projects targeted to dental workers in a child-adolescent dental care service. Methods: The subjects were 40 dentists, 43 dental hygienists, and 51 others who participated in service in Seoul. A self-administered questionnaire was used to address the problems and improvements in the project. Descriptive statistics, chi-square test, and one-way analysis of variance were performed using SPSS 23.0. Results: Oral examination was performed by 99.2% of dentists, and some service items such as professional tooth cleaning, fluoride application, and scaling were performed by dental auxiliary personnel regardless of legal duties. The problem was that the subjects took a lot of time in providing services, and students or guardians participating in the project refused to receive preventive dental services. As regards improvements, the insurance fee was the highest (48.1%), followed by the provision of regular services (38.8%), and system improvement and administrative support (35.7%). Conclusions: To activate a child-adolescent dental care service, it is thought that continuous efforts such as providing financial support by the government, education to increase participants' understanding, and social consensus for the participation of service providers and beneficiaries are required.

상업 운항 중인 대형 컨테이너선의 항차 중 속력 시운전을 통한 선속-동력 특성 연구 Part I (Study on the Speed-Power Characteristics Through a Speed Trial of a Large Container Vessel During a Commercial Voyage Part I)

  • 김호;이준형;장진호;안해성;강대열;변상수
    • 대한조선학회논문집
    • /
    • 제58권6호
    • /
    • pp.366-374
    • /
    • 2021
  • This paper presents the analysis of the speed-power performance in the real sea using a large container vessel data provided as a test bed from a shipping company. To perform a speed trial of the vessel during a commercial voyage, the on-board measuring device and various operation data acquisition systems were mounted on the vessel for long-term performance monitoring and the voyage operated under the container loading condition close to the design draft was adopted. The content of this paper consists of Part I and Part II. Part I, such as this paper, contains the speed trial method and analysis results of the operating vessel. Part II contains the analysis of the speed-power characteristics change over time and before and after hull cleaning using operation data measured from the voyage operated under a condition similar to the speed trial.

Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography

  • Katheng, Awutsadaporn;Kanazawa, Manabu;Komagamine, Yuriko;Iwaki, Maiko;Namano, Sahaprom;Minakuchi, Shunsuke
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.45-55
    • /
    • 2022
  • PURPOSE. This in vitro study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. MATERIALS AND METHODS. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40℃. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α < .05). RESULTS. The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group (P < .05). For precision, this was significantly different from those of other groups (P < .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. CONCLUSION. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.

Industrial application of WC-TiAlN nanocomposite films synthesized by cathodic arc ion plating system on PCB drill

  • Lee, Ho. Y.;Kyung. H. Nam;Joo. S. Yoon;Jeon. G. Han;Young. H. Jun
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2001년도 춘계학술발표회 초록집
    • /
    • pp.3-3
    • /
    • 2001
  • Recently TiN, TiAlN, CrN hardcoatings have adapted many industrial application such as die, mold and cutting tools because of good wear resistant and thermal stability. However, in terms of high speed process, general hard coatings have been limited by oxidation and thermal hardness drop. Especially in the case of PCB drill, high speed cutting and without lubricant process condition have not adapted these coatings until now. Therefore more recently, superhard nanocomposite coating which have superhard and good thermal stability have developed. In previous works, WC-TiAlN new nanocomposite film was investigated by cathodic arc ion plating system. Control of AI concentration, WC-TiAlN multi layer composite coating with controlled microstructure was carried out and provides additional enhancement of mechanical properties as well as oxidation resistance at elevated temperature. It is noted that microhardness ofWC-TiA1N multi layer composite coating increased up to 50 Gpa and got thermal stability about $900^{\circ}C$. In this study WC-TiAlN nanocomposite coating was deposited on PCB drill for enhancement of life time. The parameter was A1 concentration and plasma cleaning time for edge sharpness maintaining. The characteristic of WC-TiAlN film formation and wear behaviors are discussed with data from AlES, XRD, EDS and SEM analysis. Through field test, enhancement of life time for PCB drill was measured.

  • PDF

세척 방법 및 세척 시간에 따른 3D 프린팅 방식으로 제작된 임시 보철물의 변연 및 내면 적합도 평가 (Evaluation of Marginal and Internal Gap of Temporary Prosthesis Fabricated by 3D Printing Method According to Rinsing Method and Rinsing Time)

  • 배지현;최재원
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.561-570
    • /
    • 2023
  • This study was to evaluate the effect of different rinsing times and methods on the accuracy of temporary prostheses fabricated by 3D printing method. Sixty temporary prostheses were fabricated with LCD types of 3D printer(Halot-Sky, Creality, Shenzhen, China) and divided into six groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5 and 10 min using three methods-hand washed, ultrasonic cleaning, and automated washing. All specimens were polymerized for 3 minutes under the same conditions. The marginal and internal gaps of specimens were examined using a replica technique. The light-body silicone thickness was measured at 6 reference points(Absolute marginal discrepancy, Marginal, Chamfer, Axial, Angle, and Occlusal gap). All measurements were performed by a stereomicroscope. Reference point images were taken at 100× magnification and then measured using an image analysis program. Statistical analysis was performed using Two-way ANOVA, One-way ANOVA, and the Kruskal-Wallis test (p = .05). The marginal and internal gaps were statistically different according to the rinsing methods and rinsing times(p < .001). In the rinsing time, the temporary prosthesis rinsed for 5 minutes group showed higher accuracy than 10 minutes group. In the rinsing method, the hand washing group showed higher accuracy than the automated washing group.