Cleanliness Test by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment (전자·반도체용 스프레이 분사형 세정제에 대한 청정도 평가)

  • Heo, Hyo Jung;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • A spray-type cleaning agent in utilizing dust-remover on PCB was chosen to study the cleanliness test and efficiency. In order to choose alternative environmental-friendly cleaning agents, it is important that the systematic selection procedures should be introduced and applied through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. A novel cleaning evaluation method with scanning electron microscopy/energy-dispersive X-ray analysis of surface observation evaluation method and an infra-red thermography camera(THERMOVISION A20 model) was studied in this work. The sound card(CT-2770 model) cut by $2{\times}2cm$ size was used as a part, and before and after the spray cleaning, the cleanliness was observed by the image analyzer of SEM and further the removal efficiency of dust was quantitatively evaluated by the component analysis of EDX. For the parts of P4TE model motherboard and IPC-A-36 PCB plate, before and after the spray cleaning, temperature differences were measured and compared at room temperature and 50 oven temperature by an infra-red thermography camera in the contaminants of dust and iron powder.

Fouling and cleaning of a tubular ultrafiltration ceramic membrane

  • Siddiqui, Farrukh Arsalan;Field, Robert W.
    • Membrane and Water Treatment
    • /
    • v.7 no.5
    • /
    • pp.433-449
    • /
    • 2016
  • The successful application of cleaning protocols is vital for optimized filtration processes. A series of experiments with an ultrafiltration ceramic tubular membrane were carried out for the foulants dextran and carboxymethyl cellulose. Firstly, the impact on fouling of concentration changes was investigated with the increase in resistance being used as the key parameter. In the second phase, removal of reversible fouling was also investigated by employing intermittent rinsing consisting of a cold water rinse followed by a hot one. A comparative analysis for both foulants is reported. Across a range of concentrations and for both foulants, the reduction in resistance due to rinsing was found to depend upon concentration (C); it changed as $C^n$ where n was found to be 0.3. A plausible semi-theoretical explanation is given. Thirdly, for both foulants, the application of a combination of strong alkaline solutions with oxidizing agent (mainly sodium hypochlorite) followed by acid was found to be appropriate for cleaning of the ceramic membrane. The effect of increased temperature for cleaning agents followed by a warm water rinse contributed positively to the cleaning capability.

Evaluation of Self-Cleaning Performance of Mortar Using Nano-Titanium Dioxide Photocatalytic Coating (나노 이산화티탄 광촉매 코팅을 적용한 모르타르의 자기정화성능 평가)

  • Yang, In-Hwan;Jeon, Hyo-Jin;Lee, Seung-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.56-65
    • /
    • 2022
  • This paper aims at estimating self-cleaning performance of mortar coated with photocatalytic suspension under various conditions. Experimental variables included the concentration (1.5 % and 3.0 %) of photocatalytic suspension for coating mortar specimen, the presence of hydrophilic agent in photocatalytic suspension, and applying the primer on the surface of mortar. The color change of methylene blue solution increased and accordingly self-cleaning performance increased as photocatalytic concentration increased. The presence of hydrophilic agent in photocatalytic suspension slightly decreased the self-cleaning performance compared to the conventional photocatalytic suspension. Test results also showed that mortar specimen including primer and specimen not including primer did not show significantly different self-cleaning performance. In addition, cracks on the surface of mortar specimens decreased as the photocatalytic concentration increased. Therefore, increase in cracks on the surface of mortar at different photocatalytic concentration might adversely affect the self-cleaning performance of mortar specimens.

A Study on the Cleaning Efficiency Valuation of Alternatives Cleaning Agent for Trichloroethane & Trichlorotrifluoroethane (Trichloroethane과 Trichlorotrifluoroethane의 대체세정제에 대한 세정력 평가에 관한 연구)

  • Lee, Seok-Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.111-117
    • /
    • 1996
  • Many alternatives to Trichlorothane & Trichlorotrifluoroethane mainly used as cleaning solvent for industrial parts are developed and commercialized because the solvent is scheduled to phaseout after 1996. Considering there are many kinds of parts and contaminants in all parts cleaning, It is essential to investigating the characteristics and performance of the alternatives prior to use. For the contaminant of a standard oil, waters, hydrocarbon and halogen parts which are the comercially available and promising alternatives were experimented at the same condition of Trichlorothane & Trichlorotrifluoroethane to check the cleaning performance. Overally, the removal efficiency of halogen solvent parts was better than that of hydrocarbon or waters parts for removing the standard oil used in this experiment.

Acoustic waves in a high-frequency ultrasonic cleaner (고주파 초음파 세정기의 파동 해석)

  • 최성훈;김진오;김용훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.656-661
    • /
    • 1997
  • Ultrasonic cleaning at high frequency near 1MHz, called megasonic cleaning, is commonly used to remove particles less than 1.mu.m by generating accelerations on them. Ultrasonic waves generated from piezoelectric transducers are transmitted through a non-metallic inner container which is used to isolate a cleaning object from metallic ions. The transmission characteristics of a double-structured megasonic cleaner on the variations of parameters such as the thickness and oblique angle of a inner container, chemical ratio of a cleaning agent and temperature and transmittivity are investigated. The results are used to determine an optimum cleaning condition.

  • PDF

Study on the Gel Cleaning System for Removal of Poly (vinyl acetate) Fixative of the Mural Paintings of the Payathonzu Temple in Bagan, Myanmar (I) - Focusing on Properties and Removability of Gel Cleaners -

  • Yu, Yeong Gyeong;Han, Gyu-Seong;Lee, Hwa Soo;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.37 no.4
    • /
    • pp.370-379
    • /
    • 2021
  • In the past, PVAc [poly(vinyl acetate)] was used as a fixative for the conservation of the murals in the murals of the Payathonzu temple located in Bagan, Myanmar. In this study, attention was paid to gel cleaning as a method for stably removing such PVAc fixatives. Based on the recent research trend related to the cleaning of murals in Bagan ruins, 3 types of gelling agents (Nevek®, Laponite®RD, Carbopol®980) and 2 types of organic solvents (Acetone, Dimethyl carbonate) were selected. Six types of gel cleaners were prepared by mixing gelling agents and organic solvents, and the properties and fixative removability of these cleaners were compared. As a result of confirming the properties of the prepared gel cleaners, the pH of the cleaners was all in the weak acidic to weakly alkaline range, which was a stable condition for mural application. Also, there was no difference in the viscosity of the cleaners depending on the type of solvent, but there was a difference depending on the type of gelling agent used. Regarding the weight loss ratio of PVAc, which is an indicator of removability, the exposure conditions of the gel cleaners, the boiling point of the solvent used, and the viscosity of the gelling agent acted as factors affecting. As a result of comparing the removability of gel cleaners, it was confirmed that the solvent's fixative solubility, the volatility of the solvent itself, and the solvent release control properties of the gelling agent had a great effect on the removability of the gel cleaners. In Part 2, the stability and the running applicability of the gel cleaners will be investigated by making mockup samples reflecting the properties of the materials and techniques used to produce the mural paintings in the Payathonzu Temple.

Influencing Factors on Cleaning Ability in the Formulated Hydrocarbon-based Cleaning Agents (탄화수소계 배합세정제에서의 세정성 영향인자 연구)

  • Jung, Young-Woo;Lee, Ho-Yeoul;Bae, Jae-Heum
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.143-150
    • /
    • 2007
  • The objective of this study is to develop hydrocarbon-based cleaning agents by blending paraffins, glycol ethers and siloxanes in oder to effectively clean contaminants such as flux, solder and grease. And the effect of cleaning ability by wetting index, aniline points and solubility parameter of the formulated hydrocarbon-based cleaning agents were studied in this work. The formulated hydrocarbon-based cleaning agents were prepared on the base of physical properties of their individual components. Wetting indexes and aniline points of their were measured through experiments and solubility parameters of their were calculated based on the Hansen's equation. In this study, evaluation of cleaning ability by cleaning agents were carried out using contaminants such as flux, solder, and grease. The experimental results showed that the cleaning ability of the formulated cleaning agents was excellent in cleaning contaminants such as flux, solder and grease and that the influencing parameters on their cleaning efficiency were found to be different according to contaminant types. MC($20.3MPa^{1/2}$), DF-1 ($24.2MPa^{1/2}$) and DF-2($21.5MPa^{1/2}$) with similar solubility parameter as flux ($21.3MPa^{1/2}$) showed 100% cleaning efficiency within 3 minutes in flux cleaning. And CFC-113, MC and 1,1,1-TCE with low aniline point less than $-20^{\circ}C$ showed excellent cleaning efficiency in solder cleaning. DG-1($16.2\;MPa^{1/2}$) and DG-2($15.5\;MPa^{1/2}$) with similar solubility parameter as grease($15.0{\sim}17.0\;MPa^{1/2}$) showed relatively low cleaning efficiency of grease, but CFC-113 and MC with high wetting index and low aniline point showed good cleaning efficiency in grease cleaning. As a result of this study, the hydrocarbon-based cleaning agents alternative to regulated cleaning agents such as CFC-113, 1,1,1-TCE and MC were able to be developed through properly blending paraffins, glycol ethers and siloxanes for cleaning flux, solder and grease. And it can be shown that various influencing parameters of cleaning efficiency such as wetting index, aniline point, solubility parameter and etc. of the non-aqueous cleaning agent should be reviewed for prediction of their cleaning ability and can be applied to formulation of cleaning agents.

  • PDF

Evaluation of Cleaning Ability of Aqueous Cleaning Agents according to their Additives (수계세정제의 첨가제에 따른 세정성 평가연구)

  • Kim, Hansung;Bae, Jae Heum
    • Clean Technology
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2006
  • Aqueous cleaning agents which are considered to be environmental-friendly and promising alternative ones among various industrial cleaning agents were evaluated in this words. In order to formulate aqueous cleaning agents, primary alcohol ethoxylates with 3, 5 and 7 moles of ethylene oxides among nonionic surfactants were selected as main surfactants. And anionic surfactants and alcohols were chosen as their cosurfactants. Builders such as NaOH, KOH, $Na_2CO_3$ and $NaHCO_3$ were also evaluated as additives for improvement of cleaning efficiency of aqueous cleaning agents. The experimental results of cleaning ability tests show that introduction of anionic surfactant TLS as cosurfactant in alcohol ethoxylate-based aqueous solution gives the best cleaning efficiency for removing mixed soil of cutting oil and grease. NaOH and $Na_2CO_3$ are also shown to play an important role for improvement of cleaning efficiency in a aqueous cleaning agent.

  • PDF

Optimization of chemical cleaning for reverse osmosis membranes with organic fouling using statistical design tools

  • Park, Ki-Bum;Choi, Changkyoo;Yu, Hye-Weon;Chae, So-Ryong;Kim, In S.
    • Environmental Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.474-484
    • /
    • 2018
  • The cleaning efficiency of reverse osmosis (RO) membranes inevitably fouled by organic foulants depends upon both chemical (type of cleaning agent, concentration of cleaning solution) and physical (cleaning time, flowrate, temperature) parameters. In attempting to determine the optimal procedures for chemical cleaning organic-fouled RO membranes, the design of experiments concept was employed to evaluate key factors and to predict the flux recovery rate (FRR) after chemical cleaning. From experimental results and based on the predicted FRR of cleaning obtained using the Central Composite Design of Minitab 17, a modified regression model equation was established to explain the chemical cleaning efficiency; the resultant regression coefficient ($R^2$) and adjusted $R^2$ were 83.95% and 76.82%, respectively. Then, using the optimized conditions of chemical cleaning derived from the response optimizer tool (cleaning with 0.68 wt% disodium ethylenediaminetetraacetic acid for 20 min at $20^{\circ}C$ with a flowrate of 409 mL/min), a flux recovery of 86.6% was expected. Overall, the results obtained by these experiments confirmed that the equation was adequate for predicting the chemical cleaning efficiency with regards to organic membrane fouling.

Effect of surfactant types in aqueous cleaning agents on their physical properties, cleaning ability and oil-water separation (수계세정제의 계면활성제 종류에 따른 물성, 세정성 및 유수분리 영향 연구)

  • Park, S. W.;Cha, A. J.;Kim, H. T.;Kim, H. S.;Bae, J. H.
    • Clean Technology
    • /
    • v.9 no.1
    • /
    • pp.9-21
    • /
    • 2003
  • CFC-113 and 1,1,1-TCE which are ozone destruction substances are not used any more in the advanced countries because of Montreal protocol. MC and TCE are now used restrictively at small part of industrial fields in most of countries since they are known to be hazardous or carcinogenic materials. Thus, it is indispensible that the alternative cleaning agents which are environmental-friendly and safe, and show good cleaning ability should be developed or utilized for replacement of the halogenated cleaning agents. Aqueous cleaning agents are evaluated to be promising alternative ones among various alternatives in environmental and economical view point. This study has been carried out as a part of development program of aqueous cleaning agent. First of all, several types of surfactants which are the most important component in aqueous cleaning agents were chosen, and the physical properties, foaming ability, cleaning ability and oil-water separation efficiency of their aqueous solutions were measured and compared for selection of proper type of surfactant in aqueous cleaning agents.

  • PDF