• Title/Summary/Keyword: Cleaner

Search Result 673, Processing Time 0.024 seconds

Experimental Analysis of Flow Fields inside Intake Heads of a Vacuum Cleaner

  • Daichin;Lee, Sang-Joon
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.894-904
    • /
    • 2005
  • The flow structure inside the intake head greatly affects the working efficiency of a vacuum cleaner such as suction power and aero-acoustic noise. In this study, the flow inside intake heads of a vacuum cleaner was investigated using qualitative flow visualization and quantitative PIV (Particle Image Velocimetry) techniques. The aerodynamic power, suction efficiency and noise level of the intake heads were also measured. In order to improve the performance of the vacuum cleaner, inner structure of the flow paths of the intake head, such as trench height and shape of connection chamber were modified. The flow structures of modified intake heads were compared with that of the original intake head. The aero-acoustic noise caused by flow separation was reduced and the suction efficiency was also changed due to flow path modification of intake head. In this paper, the variations of flow fields for different intake heads are presented and discussed together with results of aerodynamic power, suction efficiency and noise level.

Remediation effect of indoor airborne fungi by operating the ionizing air cleaner in the university office.

  • Heo, S.M.;Song, J.H.;Paik, N.W.
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.181-182
    • /
    • 2003
  • Our study from Feburary to March, 2003, were done in university office A and B, located in Seoul. This study was carried out to investigate the reduction of the airborne fungi before and after we activate the air cleaner which using ionization. And the method of assessment was done by the CAMNEA method. The result was as follows. 1. In the research office A, the concentration of the airborne fungi was 18(${\pm}$11.3) CFU/㎥ before the ionizing air cleaner system was turned on: whereas three days after this result the concentration decreased to less than 1 CFU/㎥. 2. In the laboratory office B, the concentration was 210.6(${\pm}$5.3) CFU/㎥ before using the air cleaner and was decreased to 32.2(t 10.3) CFU/㎥ after using the air cleaner. The remediation rate in the experiment was 85 percentile,

  • PDF

Development of Index for Sound Quality Evaluation of Vacuum Cleaner (인공지능망을 이용한 진공청소기 음질 인덱스 개발)

  • 구진회;전완호;김창준;이상준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.1003-1008
    • /
    • 2004
  • In our life, we have used many digital appliances. They helped us to improve the quality of lift but sometimes gave us unsatisfactory result because they produce specific noise. Especially a vacuum cleaner produces a great deal of noise that is very annoying. So we need to study what sound metrics affect human sensibility. In this paper, we will study sound quality index for vacuum cleaner. The subjective evaluation of vacuum cleaner sound can be indicated to objective parameters by sound metrics of psychoacoustics. The artificial neural network can estimate the nonlinear characteristics of relation between subjective evaluation and sound metrics. We applied the artificial neural network to the development of sound quality index for vacuum sound.

  • PDF

The development of Air-cleaner for railroad passenger car to remove fine dust (객차내 미세먼지 저감을 위한 공기청정장치 개발)

  • Lee, Young-Seop;NamGoong, Seok;Yoon, Jong-Eun
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2125-2129
    • /
    • 2008
  • This study was the development of air-cleaner for railroad passenger car. the characteristic of air-cleaner is to improvement of in door air quality and easy of maintenance. the air-cleaner is applicated to roll filter system. advantage of roll filter is to reduce time and cost of maintenance. The developed air-cleaner was installed to the railroad passenger car, and then has fieldtested for roll filter system's performance. the result of field-test performance was average Eff. 32% that is average of several days' measurement data.

  • PDF

Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner (2단 평행판 전기집진기의 방전부 특성 실험)

  • Kim, I.S.;Lee, J.O.;Kim, Y.J.;Choi, H.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.27-34
    • /
    • 1993
  • The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.

  • PDF

A Study for the Improvement of Temperature Distribution in the Motor Housing of Vacuum Cleaner (진공청소기 모터 하우징 내부 온도상승 개선을 위한 연구)

  • Kim, Joo-Shin;Kim, Sung-Guen;Lee, Eung-Ho;Chu, Bo-Gyoung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.425-429
    • /
    • 2008
  • The present study has been conducted to improve temperature distribution in the motor housing of vacuum cleaner and reduce the development period by CFD analysis. CFD analysis is performed to investigate the thermal flow pattern in the motor housing and validated by experiments. The validation of CFD analysis is conducted by comparing the temperature distribution on motor housing cover. Through the present study the CFD analysis procedure in the motor housing of vacuum cleaner is established and various experimental materials are obtained. These analysis results can be used effectively as design factors of vacuum cleaner.

  • PDF

Comprehensive evaluation of cleaner production in thermal power plants based on an improved least squares support vector machine model

  • Ye, Minquan;Sun, Jingyi;Huang, Shenhai
    • Environmental Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.559-565
    • /
    • 2019
  • In order to alleviate the environmental pressure caused by production process of thermal power plants, the application of cleaner production is imperative. To estimate the implementation effects of cleaner production in thermal plants and optimize the strategy duly, it is of great significance to take a comprehensive evaluation for sustainable development. In this paper, a hybrid model that integrated the analytic hierarchy process (AHP) with least squares support vector machine (LSSVM) algorithm optimized by grid search (GS) algorithm is proposed. Based on the establishment of the evaluation index system, AHP is employed to pre-process the data and GS is introduced to optimize the parameters in LSSVM, which can avoid the randomness and inaccuracy of parameters' setting. The results demonstrate that the combined model is able to be employed in the comprehensive evaluation of the cleaner production in the thermal power plants.

Self-Localization Algorithm for a Mobile Air Cleaner

  • Kim, Young-Baek;Cho, Jin-Hee;Rhee, Sang-Yong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.9 no.4
    • /
    • pp.321-326
    • /
    • 2009
  • The mobile air cleaner analyzes a distribution of polluted air to purify the air fast, calculates an optimal position and moves the position so that it can remove indoor dust more quickly. At this time, the self-localization is necessary to make the mobile air cleaner move accurately to the calculated position. This paper proposed a self-localization algorithm having high accuracy without complicated calculation and implemented it by combining a ultrasonic sensor and video processing technologies, so that it is suitable for a mobile air cleaner, and as a test result, the mean error of $\pm1cm$ appeared between the actually measured position and the calculated position.

High Speed Operation of Fuel Injectors with Over Current Protection (과전류 제한 기능을 갖는 연료 분사장치의 고속 구동 방법)

  • Yang, Hyong-Yeol;Suh, Eui-Suk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2043-2048
    • /
    • 2011
  • High speed drive method for a fuel injector cleaner with current control is presented in this paper. The fuel injector cleaner is used for cleaning the fuel injectors in vehicles when it is clogged with deposit and rust. The fuel injector cleaner cleans the fuel injector by turning on and off the fuel injector rapidly. When the fuel injectors are cleaned, the switching speed is very important. However, when the fuel injector is turned off, the residual current in the fuel injector coil slows down the return action of the plunger in the fuel injector deteriorating performance and speed of the fuel injector cleaner. In this paper, fast turn off operation method of fuel injectors is developed for more effective cleaning. The simulation and experiment results show the validity of the proposed method.

The Sound Quality Evaluation and preference Analysis of Vacuum Cleaner (진공 청소기의 음질 평가 및 선호도 분석)

  • Jung, Dong-Hyun;Park, Sang-Gil;Fawazi, Noor;Lee, You-Yub;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1297-1301
    • /
    • 2007
  • The Conventional noise control attempts to simply reduce the level of product noise. But it is very straight forward way that we have consider human perception on noise. Since human listening is very sensitive to sound. Evaluation of the sound quality of a Vacuum Cleaner is studied base on human sensibility engineering. In this paper, we choose two Vacuum Cleaners that are sold in Korea and reduced noise control. Comparison Method is used to evaluate noise and preference of Vacuum Cleaner by steps. The sound quality of Vacuum Cleaner noise is analyzed by employing the subjective evaluation and by representing them in terms of the objective quantities. Semantic Differential Method is used to study sound quality Evaluation. To analyze the sound quality of Vacuum Cleaner noise, consider the coefficients of correlation between sound metrics and subjective rating. The linear regression models were obtained for the subjective evaluation and sound quality metrics.

  • PDF