• Title/Summary/Keyword: Cleaner

Search Result 674, Processing Time 0.025 seconds

Acoustic Analysis of High-Frequency Ultrasonic Cleaner

  • Choi, Sunghoon;Kim, Jin Oh;Kim, Yong-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.1E
    • /
    • pp.49-56
    • /
    • 1997
  • Ultrasonic cleaning at high frequency around 1 MHz, called megasonic cleaning, is commonly used to remove particles less than 1 ㎛ by generating high frequency accelerations on the cleaning objects. Cleaning is performed in an ultrasonically-excited liquid contained in a double-structured container. Ultrasonic waves generated by piezoelectric transducers propagate in the outer container and are transmitted through the inner container. The bottom of the inner container is inclined to make oblique incidence of the ultrasonic wave in order to raise the efficiency of the transmission through the bottom plate. This work deals with the efficiency of the transmission, which directly affects the cleaning performance. The transmission characteristics of the ultrasonic wave in the megasonic cleaner have been obtained analytically and numerically for the variations of some parameters, such as the thickness and inclined angle of the bottom plate of the inner container and the chemical ratio and temperature of the cleaning liquid. The calculated results have yielded the optimum cleaning condition in terms of the sound power transmitted into the cleaning liquid.

  • PDF

The development of Air-cleaner with Roll Filter inside railroad passenger car (롤필터를 장착한 객차용공기청정장치 개발)

  • Lee, Young-Seop;NamGoong, Seok
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1297-1301
    • /
    • 2007
  • The indoor air quality guideline of public transportation means was prepared recently. therefore we consider a countermeasure for the indoor air quality improvement of public transportation means. In this work, air-cleaner with roll filter system which developed alternative of indoor air quality guideline. The develpoed roll filter system is two function. the first function harmoniously circulated to heating and cooling air through HVAC system and secondary function removed PM(particluatie matters) which re-scatting to passenger's movement and suppled from outdoor air. Filter media of roll filter system select optimum electret mesh filter out of many filter media. Selected filter media was performanced tests of pressure drop, collection efficiency and dust holding capacity. Finally developed roll filter system was performanced bench test.

  • PDF

Improvement of the mechanical performance and dyeing ability of bamboo fiber by atmospheric pressure air plasma treatment

  • Hoa, Ta Phuong;Chuong, Bui;Hung, Dang Viet;Tien, Nguyen Dung;Khanh, Vu Thi Homg
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2009.03a
    • /
    • pp.14-20
    • /
    • 2009
  • Atmospheric pressure air plasma was applied for treatment of different kinds of natural bamboo fiber to improve their mechanical properties and surface characteristics, which are suitable for adhesion and dyeing. The tensile strength and Young modulus of bamboo fiber were significantly improved; SEM and AFM study show that the surface of fiber became cleaner and rougher after plasma treatment. Plasma treatment caused the cracking, removing of the protective skin of alkali-untreated fiber and etching to form a cleaner and rougher surface. The dyeability of both groups of bamboo fiber which are used for composite and textile purposes is significantly enhanced after treatment.

  • PDF

Acoustic waves in a high-frequency ultrasonic cleaner (고주파 초음파 세정기의 파동 해석)

  • 최성훈;김진오;김용훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.656-661
    • /
    • 1997
  • Ultrasonic cleaning at high frequency near 1MHz, called megasonic cleaning, is commonly used to remove particles less than 1.mu.m by generating accelerations on them. Ultrasonic waves generated from piezoelectric transducers are transmitted through a non-metallic inner container which is used to isolate a cleaning object from metallic ions. The transmission characteristics of a double-structured megasonic cleaner on the variations of parameters such as the thickness and oblique angle of a inner container, chemical ratio of a cleaning agent and temperature and transmittivity are investigated. The results are used to determine an optimum cleaning condition.

  • PDF

Study on the Noise Characteristic of Centrifugal Fan operating at High Pressure Region (흡입저항이 높은 원심홴 소음특성에 관한 연구)

  • Jung, Yeun-Young;Park, Jin-Won;Jeon, Wan-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1011-1014
    • /
    • 2006
  • Turbo blower generates high peaks when it operates at high pressure region. The fan of the air-cleaner system, operates especially high pressure region due to several filters, generates high noise level. In this case, the tonal sound of BPF makes people annoyance. The blower of air-cleaner has several high resistance filters in its inlet area and rotates above 900rpm Moreover, for the compact design, the size of the blower should be reduced 10%. The reduced diameter of blower makes low flow rate and high noise level. In order to reduce the noise, new blade shape was suggested and optimized

  • PDF

A Study on the Performance Improvement in the Intake System of a Large-sized Commercial Bus (대형버스 흡기시스템 성능 개선에 관한 연구)

  • Lyu, Myung-Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.16-21
    • /
    • 2005
  • The performance of reciprocating internal combustion engine is a strong function of the air intake system configuration. In order to improve engine power, it is essential to optimize the air induction system. In this study, a numerical investigation has been carried out for the three-dimensional flow and pressure characteristics in air intake system of a large-sized commercial bus. CFD simulations using STAR-CD were also perform ed to evaluate effects of intake duct geometry and structure variation inside air cleaner on the negative pressure distribution of overall intake system. Studies for improving the back pressure distribution have been proposed and quantitatively examined based on intensive case studies.

Robot Vacuum Cleaner with Air Purification based on Arduino (아두이노를 이용한 공기청정 기능을 탑재한 로봇청소기)

  • Park, Myeong-Chul;Im, Hye-Jin;Shim, In-Bo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.01a
    • /
    • pp.233-234
    • /
    • 2019
  • 전 세계적으로 미세먼지는 심각한 사회문제이다. 우리나라 또한 중국의 미세먼지와 디젤 자동차 급증 등에 의한 오염으로 인하여 호흡 시 들이마시는 공기의 질이 많이 나빠지고 있는 추세이다. 이로 인해 집 안의 환기를 위해 창문을 열거나 외출 후 귀가했을 때 옷에 붙은 미세먼지들에 의하여 집 안에 미세먼지가 쌓이게 됨으로써 건강을 위협할 수 있는 요소가 된다. 이러한 문제점들을 해결하고자 청소뿐만 아니라 공기청정 기능도 수행하게 되는 효율적인 측면을 가진 공기청정 기능을 탑재한 로봇청소기를 개발하였다. 따라서 본 논문에서는 로봇청소기의 초음파 센서와 미세먼지를 사용하여 자동으로 로봇청소기와 공기청정 기능을 탑재한 로봇청소기에 대한 연구 결과에 관해 기술하였다.

  • PDF

Regeneration of solid phase filter by chemical cleaning

  • Byung-Dae Lee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.19-26
    • /
    • 2024
  • Recently, separation membranes have been applied to fields such as water supply, sewage treatment, gray water reuse, and air pollution control. Chemical cleaning technology is attracting attention among the methods of reusing these expensive separation membranes. It was found that the separation membrane could be regenerated using chemical cleaning. Specifically, it was found that the use time of the separation membranes regenerated by chemical cleaning was sustainable for more than 1,700 hours. Additionally, it was found that the flux recovery ratio after chemical cleaning was maintained at least 60%. In addition, the flux recovery ratio of HYDREX 4710, an organic membrane cleaner, and 4703, an inorganic membrane cleaner, was 76% and 62%, respectively, showing the highest flux recovery ratio among the chemicals used. Considering that the target raw water of this study is biological secondary treatment water, it was suggested that chemical cleaning could be actively used to regenerate separation membranes in future water treatment.