• Title/Summary/Keyword: Clean level test

Search Result 57, Processing Time 0.03 seconds

A Study on Methods for Developing by Nurturing Clean Thermal Power Generation Technology (청정화력발전 기술 육성 방안 연구)

  • Kim, Yeong-Mi;Lee, Won-Hak
    • Journal of Climate Change Research
    • /
    • v.9 no.2
    • /
    • pp.197-207
    • /
    • 2018
  • The Korean government views coal-fired power plants as the key cause of the fine dust generation, and is developing an energy policy to replace and demolish old coal-fired power plants. According to the Eighth Power Supply Base Plan (2017-2031), the maximum power capacity in 2030 is expected to be 100.5GW, which is 17.9% higher than the current level (85.2GW). The plan aims to reduce the facility size and power generation ratio from nuclear and coal resources to even lower levels than today, and to rapidly expand power generation from new and renewable energy. Despite that, the proportion of coal power generation is still much higher than other resources, and it is expected that the reliance on goal will maintain for next several decades. Under such circumstances, the development, supply, and expansion of clean coal technology (CCT) that is eco-friendly and highly efficient, is crucial to minimize the emission of pollutants such as carbon dioxide and fine dust, as well as maximize the energy efficiency. The Korean government designated the Yong-Dong Thermoelectric Power Plant in Gangneung to develop clean coal power generation, and executed related projects for three years. The current study aims to suggest a plan to develop parts, technologies, testing, evaluation, certification, and commercialization efforts for coal-fired power generation, In addition, the study proposes a strategy to vitalize local economy and connect the development with creation of more jobs.

Flight Test of Stalling Speed for ChangGong-91 (창공-91 실속속도 비행시험)

  • Lee, Jung-Hoon;Kim, Chil-Young
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.3
    • /
    • pp.1-6
    • /
    • 2008
  • The stalling speed flight test of light airplane, ChangGong-91, was performed to acquire the certification. With power-off engine condition, the wings level stall flight tests were conducted at the aircraft configuration of various flap angle - clean, 20degree, and full flap, respectively. They were performed considering with the combination of the maximum and minimum test weight, and forward and afterward center of gravity. The stalling speeds and the minimum speeds of light airplane were determined from the results of flight test. Also, the appropriateness of stall warning speeds are evaluated through the flight test measures. The airplane is recoverable only with pitch control and engine throttle from stall state without exceptional operation.

  • PDF

Characteristics for Sound Power of Wind Turbine Gearbox by Load Variation (부하변동에 따른 풍력발전기용 증속기의 음향파워 특성)

  • Lee, Jae-Jeong;Lee, Seung-Yong;Seo, Young-Wook;Lee, Jin-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.311-315
    • /
    • 2012
  • In these days, promising renewable energy, wind turbine is clean energy but has an environmental pollutant which is noise. Noise assessment is one of the major performance evaluations for wind turbine and nowadays, developing and research for measurement and method of the assessment considering environmental pollutants is being important. Object in this study is that figuring out sound power characteristic of the gearbox for wind turbine through measuring sound intensity. In back-to-back test, we can figure out the noise characteristic of the gearbox for wind turbine through comparing and measuring sound pressure level, sound power level in operating at the each load condition respectively.

  • PDF

Effects of Jinyeosoo Clean Mist on the Improvement of Facial Skin in Middle-aged Women (진여클린미스트를 이용한 중년여성의 안면피부개선 효과)

  • Kim, Min Joo
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.3
    • /
    • pp.220-228
    • /
    • 2021
  • In this study, 20 middle-aged women aged from 35 to 55 were studied from October 12, 2020 to November 15, 2020 to find out the effects of improvement of facial skin of Jinyeosoo Clean Mist. Among the 20 participants, 10 were divided into experimental group and 10 control group. The Janus facial skin scope system (PSI Co.) used on the skin to measure pore, wrinkles, elasticity, UV pigmentation, and skin tone observed depending the difference in light sources. The facial examination took place 10 minutes after cleansing to stabilize and a total of 4 examinations were carried out after every week of using Jinyeosoo Clean Mist for 4 weeks. For statistical processing, SPSS statistics program 21.0 was utilized to compare the mean averages of pre-experimental and post-experimental data from the above two groups - the experimental group that used Jinyeosoo Clean Mist (hydrogen ion mist) 1 and 2 and the control group that did not use the subject products - and the corresponding sample t-test was used. As a result of the analysis, the group that used Jinyeosoo Clean Mist showed difference in pores (t=3.280, p<.05), wrinkles (t=4.353, p<.01) and elasticity (t=3.003, p<.05), skin tone(t=3.280, p<.01) under the statistical significance level.

Analysis of CA Certification Performance Test Results and Improvement of CA Test Method for a Better Differentiation of Gas Removal Performances for Room Air Cleaners (공기청정기 CA 규격성능시험 결과 분석 및 가스시험 변별력 향상 방안연구)

  • Kim, Hak-Joon;Han, Bangwoo;Kim, Yong-Jin;Cha, Sung-Il
    • Particle and aerosol research
    • /
    • v.7 no.3
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4 times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

Properties of Surface Electrical Conduction in Materials for Outdoor Insulator (옥외 애자용 재료의 표면 전기전도특성)

  • 박영국;강성화;정수현;이운석;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.207-210
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition. The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

Adsorptive Desulfurization of Diesel for Fuel Cell Applications: A Screening Test

  • Ho, Hoang Phuoc;Kim, Woo Hyeong;Lee, So-Yun;Son, Hong-Rok;Kim, Nak Hyeon;Kim, Jae-Kon;Park, Jo-Yong;Woo, Hee Chul
    • Clean Technology
    • /
    • v.20 no.1
    • /
    • pp.88-94
    • /
    • 2014
  • During the past decades much attention has been paid to the desulfurization of diesel oil which is important as a source for the fuel cells to prevent the sulfur poisoning of both diesel steam reforming catalyst and electrode of fuel cell. Although alternative desulfurization techniques have been investigated, desulfurization for ultra-low sulfur diesel (ULSD) is still challenged. Therefore, this research focuses on the desulfurization of commercial ULSD for the application to molten carbonate fuel cell (MCFC). Herein, the performances of several kinds of commercial adsorbents based on activated carbons, zeolites, and metal oxides for desulfurization of ULSD were screened. The results showed that metal oxides based materials can feasibly reduce sulfur concentration in ULSD to a level of 0.1 ppmw while activated carbons and zeolites did not reach this level at current conditions.

A Study on the Effectiveness of Remanufacturing Technology for the Diesel Oxidation Catalyst(DOC) Deactivated by Diesel Exhaust Gas (경유차 매연저감장치에 의해 비활성화된 DOC촉매의 재제조 효과에 관한 연구)

  • Park, Hea-Kyung
    • Clean Technology
    • /
    • v.16 no.4
    • /
    • pp.265-271
    • /
    • 2010
  • The deactivated diesel oxidation catalyst(DOC) was remanufactured by ultrasonic wave treatment with various solutions, followed by active component re-impregnation. The catalytic performance and surface properties of remanufactured DOC were studied at various remanufacturing conditions. The proper ultrasonic-wave cleaning time at various solutions and optimal re-impregnation amounts of active component for the best catalytic performance were investigated. The catalytic performance tests on the conversions of CO and THC(total hydrocarbon) were also carried out at various temperatures by catalytic reaction test unit using bypass gas from the diesel engine dynamo system. It was found that the catalytic performance of DOC remanufactured with the high-temperature air washing, ultrasonic wave cleaning at acidic/basic solutions and active component re-impregnation method was recovered to 90% level of its activity compared to that of the fresh DOC, which was caused by removing the deactivating materials from the surface of the DOC through the analyses of catalyst performance test and their characterization by Optical microscope, EDX, ICP, TGA, and porosimeter.

A Study on the Level of Recognition & Performance of Traditional Postpartal Care for postpartal Women in Postpartum Care Center (산후조리원 이용 산모의 산후조리 인지도와 수행도)

  • Park, Shim-Hoon;Kim, Hyun-Ok
    • Women's Health Nursing
    • /
    • v.8 no.4
    • /
    • pp.506-520
    • /
    • 2002
  • The purpose of this study is to research the degree of recognition & performance of traditional postpartal care for postpartal women and to provide the basic data for improvement of service in a postpartum care center. The respondents of this study were 100 women of 6 postpartum care centers within a C province from Oct. 20 to Dec. 10, 2000. The instruments of measure were used for collecting data on the degree of recognition & performance of traditional postpartal care developed by the researcher. Data analysis consisted of frequency, percentage, mean, standard deviation, paired t-test, t-test, ANOVA which are calculated by Scheffe test and Cronbach's alpha which is used as a reliance level by using a SPSS-PC+. The results of the study were as follows:1. The average score for the degree of recognition of traditional postpartal care(Sanhujori) for postpartal women was $3.09{\pm}.31$, and they recognized that it was important. The methods which were ranked were as follows; Protecting the body from a harmful state, invigorating the body by the argumentation of heat and avoidance of cold, handling with whole heart, and keeping clean, resting without working, eating well. 2. The average score for the degree of performance of traditional postpartal care (Sanhujori) for postpartal women was $2.81{\pm}.31$, and they performed that it was important, too. The methods which were ranked were as follows; Protecting the body from a harmful state, invigorating the body by the augumentation of heat and avoidance of cold, eating well, handling with whole heart, and keeping clean, resting without working. 3. There were significant differences statistically (paired-t=-8.39, p=.000) of the degree of recognition & performance of traditional postpartal care(Sanhujori) for the postpartal women. The degree of recognition was higher than the degree of performance. So, the recognition of traditional postpartal care (Sanhujori) was higher than the performance of it. 4. There were no statistical differences of the degree of recognition & performance of traditional postpartal care(Sanhujori) among the postpartal women's age, religion, job, educational background, delivery frequency, delivery method or the sex of baby. So, the Characteristics of the respondents were not influenced as far as the degree of recognition & performance of traditional postpartal care(Sanhujori). 5. There were significant differences statistically of the degree of performance of traditional postpartal care(Sanhujori) among the 5 postpartum care centers except 1 postpartum care center(p<.01). So, the recognition of traditional postpartal care(Sanhujori) was higher than the performance of traditional postpartal care(Sanhujori) in the 5 postpartum care centers. But there was performed as good as recognition in only 1 postpartum care center.

  • PDF

Mechanism of Soil Remediation in Contaminated Area Using Vertical Drains (연직배수재(VDs)에 의한 오염지반정화 메커니즘 연구)

  • Lee Haeng Woo;Chang Pyoung Wuck;Kang Byung Yoon;Kim Hyun Tae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.5
    • /
    • pp.63-71
    • /
    • 2005
  • In-situ soil remediation mechanism through the vertical drains (VDs) is analyzed with numerical model as the error and complementary error function. Results from in-situ test and analysis indicate that the contaminant concentration ratio as initial one ( C/$C_0$) increases as the radius ratio ( r/R) increases from the injection well, and also increases as the depth ratio ( z/ H) increases from the top of contaminated area. The elapse time needed to attain $50\%$ and $90\%$ clean up level ($ t_{50},\;t_{90}$) increases as the radius ratio ( r/R) and the depth ratio ( z/ H) increase. As above results, the procedure of soil flushing in contaminated area using vertical drains makes progress from the top of injection well to the bottom of extraction well.