• 제목/요약/키워드: Clavicle fracture

검색결과 108건 처리시간 0.023초

후방으로 전위된 소아 쇄골 원위부 골절의 수술적 치료 - 1예 보고 - (Operative Treatment of Posteriorly Displaced Fracture of the Distal Clavicle in Child - A Case Report -)

  • 박현수;정태원;라종득;장영수;이병훈
    • Clinics in Shoulder and Elbow
    • /
    • 제9권2호
    • /
    • pp.207-210
    • /
    • 2006
  • We presented a case of posteriorly displaced fracture of the distal clavicle in Child. The closed reduction was failed due to posteriorly displaced proximal fragment and interpositon of trapezius muscle and periosteum. We found that periosteal sleeve and coracoclaviclar ligament and acromioclavicular ligament was intact. The open reduction should be considered for the treatment of the irreducible posteriorly displaced fracture of the distal clavicle in child.

Refracture after locking compression plate removal in displaced midshaft clavicle fractures after bony union: a retrospective study

  • Park, Ho-Youn;Kim, Seok-Jung;Sur, Yoo-Joon;Jung, Jae-Woong;Kong, Chae-Gwan
    • Clinics in Shoulder and Elbow
    • /
    • 제24권2호
    • /
    • pp.72-79
    • /
    • 2021
  • Background: A midshaft clavicle fracture is a common fracture that typically responds well to open reduction and internal fixation (ORIF). However, refracture can occur after implant removal (IR). This study aimed to analyze the rate of refracture and related factors after removal of the locking compression plate (LCP) for displaced midshaft clavicle fractures. Methods: We retrospectively reviewed the medical records of 201 patients who had undergone ORIF with LCP for midshaft clavicle fractures after IR after bony union from January 2011 to May 2018 at our institute. We evaluated basic demographic characteristics and radiographic parameters. All patients were treated with an LCP for primary fracture. The patients were divided into two groups: a refracture group that experienced a second fracture within 1 year after IR and a no-fracture group. Results: There were four cases (1.99%) of refracture; three were treated conservatively, while one was treated surgically. All patients achieved bony union. The average interval between refracture and IR was 64 days (range, 6-210 days). There was a significant difference in classification of fractures (AO Foundation/Orthopaedic Trauma Association [AO/OTA] classification) between the two groups. However, other patient demographics and radiographic measurements between refracture and IR, such as bone diameter, showed no significant difference between the two groups. Conclusions: This study showed that one in 50 patients suffered from refracture after removal of the LCP. Thus, if patients desire IR, the surgeon should explain that there is a relatively higher possibility of refracture for cases with simple or segmental fractures than for other types of fracture.

보급형 3D 프린터로 제작한 쇄골 골절 모델을 이용한 정형외과 수술에 대한 유용성과 활용가능성 평가 (Evaluation of Usefulness and Availability for Orthopedic Surgery using Clavicle Fracture Model Manufactured by Desktop 3D Printer)

  • 오왕균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.203-209
    • /
    • 2014
  • 쇄골 CT 영상을 이용하여 보급형 3D 프린터로 제작된 모델로 사전 수술계획을 실시하여 수술효율에 대한 유용성과 임상적 활용가능성을 평가하였다. CT 영상을 Open Source DICOM Viewer Osirix에서 STL 파일로 변환하여 FDM 와이어 척층가공방식의 보급형 3D 프린터로 환자 맞춤형 쇄골 골절 모델을 제작하였다. 또한, 인체의 좌우 대칭 특성을 이용하여 골절되지 않은 반대편 쇄골의 STL 파일을 Mirror 기법으로 손상되기 전 원형의 모델을 복원, 제작하였다. 모델은 골절의 위치와 크기, 정도가 동일하게 출력되었다. 영상의학과에서 적은 비용과 시간으로 직접 제작한 쇄골 모델을 활용하면 수술시 2차 손상을 줄이고, 최소 침습적 피하금속판 골유합술(MIPO)로 수술효율을 높일 수 있어 임상적으로 유용할 것으로 생각된다.

쇄골 골절 치료의 최근 경향 (Recent Treatment Options for the Clavicle Fracture)

  • 오주한;최혜연
    • Clinics in Shoulder and Elbow
    • /
    • 제15권1호
    • /
    • pp.43-51
    • /
    • 2012
  • 목적: 쇄골 골절의 치료에 관한 광범위한 자료 검토를 통해 현 시점에서의 적절한 쇄골 골절 치료방법을 찾고자 한다. 대상 및 방법: 성인에서 발생한 쇄골 골절과 관련된 전반적인 내용, 즉 쇄골 골절의 역학, 분류, 수술 적응증, 최근 도입된 치료 방법의 현황 및 결과를 문헌 고찰을 통해 정리하였다. 또한, 쇄골 중간 부위 골절의 수술 적응증의 확대와, 새로운 치료법의 하나로 주목받고 있는 anatomically precontoured plate의 도입을 비롯한 최신 지견에 대해 살펴보았다. 결과 및 결론: 지금까지 쇄골 골절은 비수술적 방법으로 대부분 치료되어 왔다. 하지만 최근 들어 기존에 추산되었던 것 보다 많은 수의 불유합, 부정유합 발생이 보고되면서 수술적 치료의 적응증이 점점 확대되는 추세이다. 하지만 아직까지는 쇄골 골절에 대한 이상적인 치료 방침이 확립되지 않았음을 고려할 때, 환자 개개인의 임상 정보와 선호도를 세심히 고려한 맞춤형 치료가 이루어져야 하겠다.

외상으로 동시에 발생한 양측 쇄골 골절 - 증례 보고 - (Simultaneous Bilateral Clavicle Fractures - A Case Report -)

  • 장기영;노권재;윤건웅;신상진
    • 대한정형외과스포츠의학회지
    • /
    • 제8권2호
    • /
    • pp.125-128
    • /
    • 2009
  • 양측 쇄골 골절은 양측 견관절 부위에 강한 외력이 동시에 작용하여 발생하는 드문 골절이다. 편측 쇄골 골절은 보존적 치료로 대부분 만족할 만한 임상 경과를 보이나 동시에 양측이 골절 되는 경우 극심한 통증과 재활 운동의 어려움을 겪게 되며, 호흡운동 장애를 초래할 수도 있다. 저자들은 다발성 늑골 골절 및 혈흉과 흉추 가시돌기 골절을 동반한 양측 쇄골 골절 환자에 대해 수술적 치료를 통해 견관절 기능 회복을 얻었으며, 호흡운동 장애 문제를 해결하였기에 문헌 고찰과 함께 보고하고자 한다.

  • PDF

Arthroscopic Stabilization for Displaced Lateral Clavicular Fractures: Can It Restore Anatomy?

  • Khan, Prince Shanavas;Yoo, Yon-Sik;Kim, Byung-Su;Lee, Seong-Jin;Ha, Jong Mun
    • Clinics in Shoulder and Elbow
    • /
    • 제19권3호
    • /
    • pp.143-148
    • /
    • 2016
  • Background: The purpose of our study was to evaluate the accuracy of reduction based on postoperative computed tomography (CT) images after arthroscopic stabilization using tightrope system for unstable distal clavicle fracture. Methods: Twelve patients with distal clavicle fracture combined with coracoclavicular (CC) ligament injury (type II, V) who received arthroscopically assisted fixation using a flip button device were evaluated for accuracy of reduction using 3-dimensional postoperative CT scan by measuring the degree of distal clavicular angulation and clavicular shortening. Results: Immediate postoperative plain radiograph confirmed restoration of the CC distance (CCD) in 10 patients. At final follow-up, the CCD remained reduced anatomically on plain radiographs in these patients. All patients showed excessive posterior angulation and shortening compared to the opposite side. The average Constant score recovered to 94.8 at final follow-up. Conclusions: Indirect reduction and arthroscopic subacromial approach with flip button fixation of unstable distal clavicle fractures demonstrated favorable clinical results despite unavoidable posterior angulation of distal clavicle and shortening the total length of clavicle.

Unusual Migration of Kirschner's Wire into Intervertebral Foramen after Lateral Clavicle Fracture Fixation - A Case Report

  • Lee, Jin-Ho;Chung, Jae-Yoon;Kim, Myung-Sun
    • Clinics in Shoulder and Elbow
    • /
    • 제17권2호
    • /
    • pp.77-79
    • /
    • 2014
  • The migration of metallic devices such as Kirschner's wire (K-wire) from the shoulder is a well-recognized and significant complication of operation, the wire ending up in the lungs, the heart, the esophagus, the aorta or the subclavian artery. However, spinal migration is very rare. We report the case of a 72-year-old female patient with K-wire migration into the C7-T1 intervertebral foramen, 2 months after surgery for a lateral end fracture of left clavicle.

쇄골 간부골절의 전하방 부착 재구성 금속판을 이용한 치료 (Anterior inferior reconstruction plate on acute midshaft clavicle fvacture)

  • 강재도;김광열;김형천;임문섭;김성훈;권준형
    • Clinics in Shoulder and Elbow
    • /
    • 제6권1호
    • /
    • pp.44-49
    • /
    • 2003
  • Purpose: Many different operative technique of mid-shaft clavicle fracture have been reported. The aim of this prospective study was to compare the results of anterior or anterior-inferior plating with superior plating on the acute mid-shaft fracture of clavicle Materials and Methods: From February1997 to February 2002, thirty-eight consecutive open reduction and internal fixation with reconstruction plates were performed in thirty-eight patients. from August 1999, anterior or anterior-inferior plating was mainly used, prospectively. The duration of follow-up averaged 17 months (range,23 to 43 months). The mean age was 38 years old (range,21 to 57 years old) on anterior or anterior-inferior plating group and 35 years old (range,24 to 55 years old) on superior plating group. The physician progress note, VAS patient complement score, Roentgenogram and ASES score was evaluated. Results: Four patients were lost to follow-up. There was no statistical difference on mean radiological bone union time (8.7 weeks vs. 8.6 weeks) and ASES score (92 vs 94) at inferior and superior plating groups (P > 0.05). VAS patient complement score was very good or excellent on anterior or anterior-inferior group, average score was 1.1 (ranger,0 to 2) compare with superior plating group (P < 0.05). There were two cases of infection, 1 case of failed fixation on superior plating group and 1 case of delayed union on anterior inferior plating group. Conclusion: Anterior inferior plating on acute clavicle midshaft fracture results in excellent patient complement score compare with conventional superior reconstruction plate.

Anatomical Locking Plate with Additional K-wire Fixation for Distal Clavicle Fracture

  • Nam, Woo-Dong;Moon, Sung-Hoon;Choi, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.230-235
    • /
    • 2017
  • Background: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. Methods: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. Results: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. Conclusions: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.

공개용과 상업용 DICOM STL 파일변환 프로그램으로 출력한 삼차원 프린팅 쇄골 골절 모델의 품질비교 (Comparison of the Quality of Clavicle Fracture Three-dimensional Model Printing by Open Source and Commercial use Digital Imaging and Communications in Medicine Stereolithography File Conversion Program)

  • 오왕균;김형균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권1호
    • /
    • pp.61-66
    • /
    • 2018
  • The recent 3D printing technology is used in various medical, manufacturing, and education fields and is more efficient in terms of production process, time, and cost than existing production. Especially in fracture surgery, interest and research have been focused on improving accuracy, shortening of operation time and recovery time, and reducing reoperation. However, because of the financial and technical problems of the 3D printer and the file conversion program, the 3D printing is made directly at the hospital, and it is not generally used for diagnosis of fracture and surgical research. In this study, to solve those problems, clavicle CT imaging was switched into Osirix Open Source DICOM Viewer, Stereolithography file conversion programs and commercial Terarecon 3D DICOM Viewer, file conversion programs, and then clavicle fracture model was directly made through 3D printer of fused filament fabrication wire additive processing method, and then the accuracy of the shape was compared and analyzed. Clavicle fracture models printed in two methods were blind-tested on clinicians of general hospitals' orthopedics and radiologic technicians with over 10 years of experiences, and then their analysis opinions of resolution reviews were analyzed. The result showed no difference. The 3D printing model with open source DICOM STL file conversion program used was applicable to clinical, so it is considered useful in precision diagnosis of fracture and operation plans.