• Title/Summary/Keyword: Class B fire

Search Result 24, Processing Time 0.024 seconds

A Study on the Flame Extinguishing Characteristics of Inerting Gaseous Agents (불활성가스계 소화약제의 불꽃소화 특성에 관한 연구)

  • Kim, Sung-Min;Shin, Chang-Sub;Park, Jae-Man
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.148-150
    • /
    • 2008
  • Halon gas agent has been widely used as the extinguishing agent for B class and C class fires because of its excellent extinguishing power. But Halon was found to contribute to the ozone layer destruction, eventually Halon designated as one of ozone-layer-destroying materials in the Montreal Protocol in 1987, In this study, in the context of such researches, we measured the characteristics of flame concentrations of inert gaseous agents by Cup-burner method.

  • PDF

Fire Extinguishing Capability of an Automatic Spreading Fire Extinguisher in Accordance with Horizontal Distance from a Fire Source (자동확산소화장치의 이격거리에 따른 소화성능평가연구)

  • Kwark, Ji-Hyun;Kim, Dong-Suk;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.38-43
    • /
    • 2013
  • An automatic spreading fire extinguisher usually installed in a closed area like a boiler room, a laundry store or a restaurant's kitchen room is one of the fire protection equipments. This extinguisher automatically discharges dry powder, extinguishing fire. As this extinguisher has the extinguishing capability applicable to the nominal protection area, objects outside the area cannot be properly extinguished. However only its number is being requested according to the floor area in the related laws, and the extinguishing capability depends on the distance from a fire source. In this study we tried to investigate the extinguishing capability of the automatic spreading fire extinguisher in accordance with horizontal separation distance from a fire source. It appeared that the maximum horizontal separation distance was about 30 cm for both class A and B fire to be certainly extinguished.

A Study on Ship Evacuation Safety Consequent on the Size and Sort of Fire (화재의 크기와 종류에 따른 선박 피난 안전 연구)

  • KIM, Won-Ouk;KIM, Dae-Hee
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.5
    • /
    • pp.1358-1364
    • /
    • 2016
  • Maritime accidents caused by a ship include collisions, sinking, stranding and fire etc. This study is intending to consider fire accidents among such diverse marine accidents. It is much likely that various sorts of fires break out because crewmen are living in a narrow space for long periods of time consequent on the ship's characteristic of sailing on the sea. According to the ship fire survey, about 50% of the total fire accidents occurred at an engine room, and the main fire origin was analyzed to be oil. In addition, ship fire breaks out in the order of baggage racks and living quarter. In short, the survey indicates that all sorts of fires belonging to A, B, C and D-class have occurred. This study, targeting an actual passenger ship 'A', found the response time to evacuation, during which the people on board a ship recognize the outbreak of fire, and act, and the travel time for evacuation which is the actual travel time. In addition, this study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of passengers and crew based on the collected simulation data by fire size and sort. As a result of the analysis, it was found that when examining the only actual evacuation movement time excepting the response time to evacuation, people are safe by completing evacuation before the effective evacuation time only in case fire size is 100Kw among all sorts of fires. In other words, in case of the outbreak of fire more than 1 MW, it was found to fail to meet evacuation safety regardless of fire size.

A Study on the Implementation of Inheritance Anomaly in Concurrent Programming (병행 프로그래밍에서 상속 이상의 구현에 관한 연구)

  • Cho, Myung-Hyun;Lee, Myung-Un
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.1
    • /
    • pp.53-57
    • /
    • 2005
  • When concurrency is integrated to programming language, problem more than inheritance remains yet. Because more than inheritance happens by collision or cross fire between synchronization and inheritance of same time object, when synchronization code is not detached properly from method code about same time object, it makes expanded of code to make derivation class change synchronization code of super class and method code. In this paper, minimize right of inheritance method, When subclass is introduced to new synchronization limitation condition, wish to solve problem more than inheritance of three types that happen in same time programming embodying C++ class that do so that can avoid alteration of method reed.

Full-scale Fire Suppression Test for Application of Water Mist System in Road Tunnel (미분무수 소화시스템의 도로터널 적용을 위한 실물 화재 실험)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Lee, Yu-Whan;So, Soo-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.51-56
    • /
    • 2011
  • The full-scale experiments are carried out to investigate the fire suppression characteristics of water-based fire fighting systems in a road tunnel. Applied systems are the low-pressure water spray system at 3.5 bar and the high-pressure water mist system at 60 bar. The water flow rate of the high-pressure system is one sixth only of the water spray system. A passenger car and a heptane fuel pan with area of $1.4m^2$ are used as fire sources. A blower system is installed at the tunnel exit to realize the longitudinal ventilation conditions (0.9~3.8 m/s) in the tunnel. Temperatures from the fire source to the down-stream direction are measured by K-type thermocouple trees. The experimental results show that the cooling effect of the high pressure water mist system in the test conditions were equivalent to that of the low pressure water spray system for B-class fire.

A Study on the Application Medium Expansion Foam Extinguisher by a Fire Performance Analysis used Medium Expention Foam Agent (중발포 소화약제 소화성능 분석을 통한 중발포기 적용에 관한 연구)

  • Lee, Jang Won
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.402-408
    • /
    • 2019
  • Purpose: The study want to verify application the medium expantion foam extinguisher of expantion foam rate and fire extinguishing Performance test because the medium expansion system can maintain the discharge distance less affected by air currents, and the foam agent can be used efficiently. Method: For the study, the medium-expansion testing apparatus was manufactured and with synthetic surfactant foam agent of (class B) fire extinguishing model, and Fire Performance was analyzed for foam expansion rate and the fire agent consumption was measured and analyzed. Results: We measured the medium-spray testing apparatus and found that the expansion rate was 26.1 times. The test results of a 20-unit fire extinguishing model show that the extinguishing time is faster than the high and low foam expansion. It has been analyzed that it is possible to apply a hand-operated with a hose reel or medium expansion apparatus. Conclusion: Considering that the foaming agent and the extinguishing performance of the medium foam ratio are excellent, It is necessary to introduce the technical standards of medium foam agent for the introduction of hand-operated equipment, such as hose reel or portable medium foam apparatus.

Experimental Study on the Toxicity Characteristics of Non-Class 1E Cables according to Accelerated Deterioration (가속열화에 따른 비안전등급 케이블의 독성특성에 관한 실험적 연구)

  • Jang, Eun-Hui;Kim, Min-Ho;Lee, Min Chul;Lee, Sang-Kyu;Moon, Young-Seob
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.105-113
    • /
    • 2019
  • This study investigates the toxicity characteristics of two Non-Class 1E Cables (For security reasons, we refer to company A and company B) used in nuclear power plants according to the accelerated deterioration period. In accordance with NES 713 test equipment and standards, tests were carried out on non-aged cables and the cables subjected to 20- and 40-year-accelerated-deterioration; each of the cables was further classified into sheath and insulation. The test results showed that the toxicity indices of 20- and 40-year-accelerated-aged cables were higher than those for the non-aged cables, and 20-year-aged cables of both A and B companies showed the highest toxicity indices. This is attributed to the extensive emissions of carbon monoxide and halide gases such as hydrogen chloride and hydrogen bromide. Furthermore, to analyze the toxicity indices of sheath and insulation in detail, the US Department of Defense standard (MIL-DTL) was applied to determine whether the Toxicity index (T.I.) allowance was exceeded, and the results showed that the insulating materials emitted considerably more than the allowable limit.

A Numerical Study on the Effects of SOFA on NOx Emission Reduction in 500MW Class Sub-bituminous Coal-Fired Boiler (500MW급 아역청탄 전소 보일러의 NOx 배출저감에 미치는 SOFA 영향에 관한 연구)

  • Kang, Ki-Tae;Song, Ju-Hun;Yoon, Min-Ji;Lee, Byoung-Hwa;Kim, Seung-Mo;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.11
    • /
    • pp.858-868
    • /
    • 2009
  • A numerical investigation has been carried out about the performance of a 500MW class tangentially coal-fired boiler, focusing on the optimization of separated overfire air (SOFA) position to reduce NOx emission. For this purpose, a comprehensive combination of NOx chemistry models has been employed in the numerical simulation of a particle-laden flow along with solid fuel combustion and heat and mass transfer. A reasonable agreement has been shown in baseline cases for predicted operational parameters compared with experimental data measured in the boiler. A further SOFA calculation has been made to obtain optimum elevation and position of SOFA port. Additionally, clarifying on the effect of SOFA on NOx emission has been carried out in the coal-fired boiler. As a result, this paper is valuable to provide an information about the optimum position of SOFA and the mechanism by which the SOFA would affect NOx emission.

Combustion Characteristics of a Staged Burner for a Boiler (다단 연소 버너의 보일러 연소실에서의 연소 특성)

  • Ahn, Joon;Kim, Jong-Jin;Kang, Sae-Byul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.10
    • /
    • pp.767-772
    • /
    • 2009
  • The demand for a boiler with low NOx burner is increasing with the recent strict NOx regulation. Staged burner is a common low NOx burner to suppress the formation of thermal NOx by yielding local fuel rich and lean condition. The staged burner gives fire with bigger frontal area and length compared with a conventional burner, which changes heat transfer characteristics in the combustion chamber. The heat transfer and exhaust gas characteristics have been studied in the present study for a 0.5 t/h class furnace type boiler adopting the staged burner. A numerical simulation has been conducted to clarify the detailed physics inside the combustion chamber.

Amphibian Biotope Planning to Research on Reproduction of Bombina orientalis (무당개구리(Bombina orientalis) 번식 연구를 위한 양서류 바이오톱(amphibian biotope) 조성)

  • Yoon, Seong-Il;Park, Chan-Jin;Bhan, Young-Ho;Gye, Myung-Chan
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.1
    • /
    • pp.22-29
    • /
    • 2008
  • Bombina orientalis, or Korean fire-bellied toad is belonging to Class Amphinia, Order Anura, Family Bombinatoridae, Genus Bombina. Ecological characteristics, such as small size, slow moving and swimming, gentle attitude to other species, under laboratory and/or wild condition lead the toad as suitable experimental animals with easy handling. Seasonal reproductive biology except breeding season (usually from Apr. to late Jun.) are unknown still caused by sampling methods for hibernating specimens have not been established yet. Most species of amphibian, include B. orientalis, are declined around the world related with global warming, therefore, wild caught specimen for any purposes must be limited controled soon. Even though, some pre-studies of biotope for increasing biodiversity have been reported, construction of an artificial biotope to get natural breeding cycling specimen for study of amphibian reproduction is unique modelling and only trial. In an effort to set year-round sampling for study of reproduction of B. orientalis, we suggest protocols for planning, construction manual and SOP(Standard Operation Process) to manage amphibian biotope. During pilot operation of a designed and constructed biotope, the seasonal acclimation during winter hibernation of B. orientalis were successful. It will be helpful for studying the reproductive biology of wild amphibians in temperate region and allow to get reasonable research conditions in amphibian laboratory.