• Title/Summary/Keyword: Clarity image

Search Result 81, Processing Time 0.027 seconds

A Study on the Historical and Cultural Landscape of Han River - Around East Lake of Kyung River in Joseon Dynasty - (한강(漢江)의 역사문화경관 연구 - 조선시대 경강(京江) 동호(東湖)지역(地域)을 대상으로 -)

  • Kim, Sun-Hwa;Lee, Jae-Keun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.2
    • /
    • pp.55-67
    • /
    • 2014
  • The historic cultural landscape of East lake in Kyung river area during Joseon dynasty was very outstanding that it had many attractions of scenic beauty, however, the Han river of today is being recognized as a natural landscape and as a place with low cultural and historical traits. This study applied landscape characteristics of the cultural space of Joseon Dynasty on visual image elements of Lynch to research the landscape characteristics. The research results are as follows. When East lake was applied to visual image elements, it was recognized as a 'superb' 'paths,' and the 'edge' which signifies the boundary showed its 'superb' clarity of the East lake. For the 'node,' a turning point of direction, Dumopo represented the 'superb' awareness. As East lake, Apgujung, and Jecheonjung represented the 'superb' awareness when 'landmark' among visual image elements of Lynch was applied to the cultural space, the awareness level and reputation were proportional to the visual image elements. When pattern, structure, and meaning of the cultural space were clear and had definite identity, the 'landmark' and 'district' elements were 'superb.' It was also identified that when awareness level of space was higher, the awareness of historic cultural landscape was high as well. Therefore, considering visual awareness level of the historic cultural landscape of Han river during restoration to investigate and to conduct case studies is considered to increase the awareness level of historicity and cultural character as well as restoration of the place.

Edge Enhancement for Vessel Bottom Image Considering the Color Characteristics of Underwater Images (수중영상의 색상특성을 고려한 선박하부 영상의 윤곽선 강조 기법)

  • Choi, Hyun-Jun;Yang, Won-Jae;Kim, Bu-Ki
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.7
    • /
    • pp.926-932
    • /
    • 2017
  • Image distortion can occur when photographing deep sea targets with an optical camera. This problem arises because sunlight is not sufficiently transmitted due to seawater and various floating particles of dust. Particularly, color distortion takes place, causing green and blue color channels to be over emphasized due to water depth, while distortion of boundaries also occurs due to light refraction by seawater and floating particles of dust. These distortions degrade the overall quality of underwater images. In this paper, we analyze underwater images of the bottom of vessels. Based on the results, we propose a technique for color correction and edge enhancement. Experimental results show that the proposed method increases edge clarity by 3.39 % compared to the effective edges of the original underwater image. In addition, a quantitative evaluation and subjective image quality evaluation were concurrently performed. As a result, it was confirmed that object boundaries became clear with color correction. The color correction and contour enhancement method proposed in this paper can be applied in various fields requiring underwater imaging in the future.

Optimization of the Flip Angle and Scan Timing in Hepatobiliary Phase Imaging Using T1-Weighted, CAIPIRINHA GRE Imaging

  • Kim, Jeongjae;Kim, Bong Soo;Lee, Jeong Sub;Woo, Seung Tae;Choi, Guk Myung;Kim, Seung Hyoung;Lee, Ho Kyu;Lee, Mu Sook;Lee, Kyung Ryeol;Park, Joon Hyuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Purpose: This study was designed to optimize the flip angle (FA) and scan timing of the hepatobiliary phase (HBP) using the 3D T1-weighted, gradient-echo (GRE) imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique on gadoxetic acid-enhanced 3T liver MR imaging. Materials and Methods: Sixty-two patients who underwent gadoxetic acid-enhanced 3T liver MR imaging were included in this study. Four 3D T1-weighted GRE imaging studies using the CAIPIRINHA technique and FAs of $9^{\circ}$ and $13^{\circ}$ were acquired during HBP at 15 and 20 min after intravenous injection of gadoxetic acid. Two abdominal radiologists, who were blinded to the FA and the timing of image acquisition, assessed the sharpness of liver edge, hepatic vessel clarity, lesion conspicuity, artifact severity, and overall image quality using a five-point scale. Quantitative analysis was performed by another radiologist to estimate the relative liver enhancement (RLE) and the signal-to-noise ratio (SNR). Statistical analyses were performed using the Wilcoxon signed rank test and one-way analysis of variance. Results: The scores of the HBP with an FA of $13^{\circ}$ during the same delayed time were significantly higher than those of the HBP with an FA of $9^{\circ}$ in all the assessment items (P < 0.01). In terms of the delay time, images at the same FA obtained with a 20-min-HBP showed better quality than those obtained with a 15-min-HBP. There was no significant difference in qualitative scores between the 20-min-HBP and the 15-min-HBP images in the non-liver cirrhosis (LC) group except for the hepatic vessel clarity score with $9^{\circ}$ FA. In the quantitative analysis, a statistically significant difference was found in the degree of RLE in the four HBP images (P = 0.012). However, in the subgroup analysis, no significant difference in RLE was found in the four HBP images in either the LC or the non-LC groups. The SNR did not differ significantly in the four HBP images. In the subgroup analysis, 20-min-HBP imaging with a $13^{\circ}$ FA showed the highest SNR value in the LC-group, whereas 15-min-HBP imaging with a $13^{\circ}$ FA showed the best value of SNR in the non-LC group. Conclusion: The use of a moderately high FA improves the image quality and lesion conspicuity on 3D, T1-weighted GRE imaging using the CAIPIRINHA technique on gadoxetic acid, 3T liver MR imaging. In patients with normal liver function, the 15-min-HBP with a $13^{\circ}$ FA represents a feasible option without a significant decrease in image quality.

Reproducibiity of setup error for prostate cancer by ultrasound image-guided radiation therapy (전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가)

  • Park, Sung Yong;Lim, Seung Kyu;Si, Myoung Geun;Lee, Ji Hae;Kim, Jong Yeol;Cho, Eun Joo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: To evaluate the reproducibility of image-guided radiotherapy using ultrasonography which is non-invasive, without radiation exposure for prostate cancer patients. Materials and Methods: We analyzed the setup variation of 1,105 images for 26 prostate cancer patients and the mean, standard deviation and 3D-error in AP, RL and SI directions. Setup variations were classified 0-1 mm, 1-3 mm, 3-5 mm, 5 mm and more. Results: The mean and standard deviation of setup variation in AP, RL and SI directions was $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$ and $2.01{\pm}1.40mm$. The 3D-error in AP, RL and SI directions was $3.63{\pm}1.63mm$. The frequency of setup variation in AP direction was 29 % in the range from 0 mm to 1 mm, 50.2 % in the range from 1 mm to 3 mm, 19.6 % in the range from 3 mm to 5 mm and 1.3 % in the range of 5 mm or more. In RL direction, the frequency was 31.3 % in the range from 0 mm to 1 mm, 52.5 % in the range from 1 mm to 3 mm, 15.8 % in the range from 3 mm to 5 mm and 0.5 % in the range of 5 mm or more. SI direction, the frequency of errors in the range from 0 mm to 1 mm was 26.3 %, 50.2 % in the range from 1 mm to 3 mm, 22.4 % in the range from 3 mm to 5 mm, and 1.1 % in the range of 5 mm or more. Conclusion: The setup error was highest in the SI direction of $2.01{\pm}1.40mm$. The frequency in each direction was the highest in more than 50 % in the range from 1 mm to 3 mm. $Clarity^{TM}$ Auto scan is possible to monitoring the motion of the prostate during the treatment and to repositioning the patient. In conclusion real-time image-guided radiotherapy using ultrasonography will be increase the reproducibility of radiation therapy.

  • PDF

A Study on the Implementation and Development of Image Processing Algorithms for Vibes Detection Equipment (정맥 검출 장비 구현 및 영상처리 알고리즘 개발에 대한 연구)

  • Jin-Hyoung, Jeong;Jae-Hyun, Jo;Jee-Hun, Jang;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.463-470
    • /
    • 2022
  • Intravenous injection is widely used for patient treatment, including injection drugs, fluids, parenteral nutrition, and blood products, and is the most frequently performed invasive treatment for inpatients, including blood collection, peripheral catheter insertion, and other IV therapy, and more than 1 billion cases per year. Intravenous injection is one of the difficult procedures performed only by experienced nurses who have been trained in intravenous injection, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Nurses who frequently perform intravenous injections may also make mistakes because it is not easy to detect veins due to factors such as obesity, skin color, and age. Accordingly, studies on auxiliary equipment capable of visualizing the venous structure of the back of the hand or arm have been published to reduce mistakes during intravenous injection. This paper is about the development of venous detection equipment that visualizes venous structure during intravenous injection, and the optimal combination was selected by comparing the brightness of acquired images according to the combination of near-infrared (NIR) LED and Filter with different wavelength bands. In addition, an image processing algorithm was derived to threshehold and making blood vessel part to green through grayscale conversion, histogram equilzation, and sharpening filters for clarity of vein images obtained through the implemented venous detection experimental module.

Effects of Process Conditions on Electrode Patterning by Screen Printing Method (스크린 인쇄법의 공정 조건이 전극 패턴 균일성에 미치는 영향)

  • Lee, Na-Young;Kim, Dong-Chul;Yeo, Dong-Hun;Lee, Joo-Sung;Yoon, Sang Ok;Shin, Hyo-Soon;Lee, Joon-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.5
    • /
    • pp.355-359
    • /
    • 2020
  • In this study, image analysis and surface roughness measurements using an optical microscope are presented as a method to quantitatively evaluate the results of screen printing. Using this method, the squeegee speed, which is the printing process condition, and the printability of the electrode according to the screen mesh were evaluated. Increasing the squeegee speed in the printing process acts as a process element that increases the line width precision of the printed electrode and lowers the surface roughness of the printed surface. Furthermore, the edge roughness, which indicates the clarity of printing, was not significantly affected by the speed of the squeegee during printing. The print thickness increases in proportion to the squeegee speed, but is largely dependent on the screen thickness.

The Characteristics of Identical Color Coordination In Contemporary Women's Fashion - Centered on the Collections of Paris, Milan, New York, London - (현대(現代) 여성(女性) 패션에 나타난 동일색채(同一色彩) 코디네이션의 특성(特性) - 파리, 밀란, 뉴욕, 런던 컬렉션 중심(中心)으로 -)

  • Kwon, Hae-Sook
    • Journal of Fashion Business
    • /
    • v.9 no.1
    • /
    • pp.21-33
    • /
    • 2005
  • The main objective of this research was to understand the characteristics of identical color coordination through the analysis of modern female fashion color coordination as they appear in the 'Collections'. Data collection of 2026 was done through review of '$pr\hat{e}t-\grave{a}$-porter Collections' of four cities; Milan, London, New York, Paris. Lastly, statistical analysis of frequency and $X^2$-test and also qualitative interpretation of identical color coordination characteristics were completed. The main findings were; The color coordination of modern women's fashion produces a unified theme, or monochromatic harmony, through the use and coordination of identical colors. The clear contrast of tones portrays a strong image especially in achromatic color coordination, and through the use of texture variation, monochromatic color coordination becomes even more compelling. The tone variation, observed most often in monochromatic color coordination was the black and white contrast, which enhances the simplicity and clarity. Within chromatic color combinations, tone on tone color coordination was achieved by varying brightness. Furthermore, the observation of Faux Camaeu indicates that the coordination of different textures is used often in identical color coordination. While achromatic colors can lead to a hard and rough feeling, it also is compensated through the use of varying textures. In addition, adding variety of textures can add subtle interests to the simplicity of white. Lastly, in all four collections, the chromatic identical color coordination was found more frequently than the achromatic. In Paris, N.Y. & London, the chromatic identical coordination was used more often than chromatic. Milan showed most use of achromatic coordination. The use of the tones showed similar trends in all four collections, with contrasting tone being used most often, followed by similar and identical tones.

Comparison of blue light, visible light and infrared light transmittance difference of shading Goggles (청색광, 가시광선 및 적외선이 차광보안경에 따라 투과되는 투과율 차이 비교)

  • Jung, In-Ho;Lee, Sang-Deok;Lee, Sook-Jeong
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.65-71
    • /
    • 2020
  • Purpose: To know the transmittance of light when wearing shading goggles and to protect eyes from blue light emitted from dental scanner when using CAD/CAM works or inducing polymerization reactions of dental resin with curing unit and infrared light occurred when melting Dental precious metal and non-precious metal alloys. Methods: By measuring and comparing the average transmittances of blue light, visible light and infrared ight by using UV-Vis Spectrophotometer analysis measuring instrument, I compared 3 GREEN Color Goggles worn when casting Dental precious metal and non-precious metal alloys, and compared each of YELLOW, ORANGE Color Goggles worn when using Dental CAD/CAM scanners and Light Curing(LED) the Dental resin. Results: In blue light range, YELLOW Color Goggles are more effective than ORANGE Color Goggles. In infrared light range, No.12 Goggles are more effective than No.10 and No.11 Goggles. Conclusion: When wearing blue light shading goggles to avoid harmful blue light occurred in using dental scanner and curing light, and when wearing infrared light shading goggles to avoid harmful infrared light during casting, to avoid the Side Effects like transmittance rate of blue light and infrared light goggles becomes too high to block appropriate amount of harmful light or too low that causing lower image clarity.

A study on the animal figures in Scytian Ornament -focusing on the single animal figures (스카타이계 장식품에 나타난 동물문에 대한 연구 -단독동물문을 중심으로-)

  • 김문자
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.8
    • /
    • pp.13-27
    • /
    • 2000
  • The background of single animal figures was originated from those northern mounted nomadic groups, which was Scythe style Culture. The art of the nomads working in the Scythian idiom was small in size and essentially decorative in intention, yet practically every object which can be associated with any unit in this group of people possesses many of the attributes essential to a real work of art. Clarity of conception, purity of form, co-ordination of rhythm and balance, and not least, an understanding and respect for the material employed were triumphantly blended by the Eurasian nomads to produce a distinctive style. In Scythian art the multitude of animal representations well illustrates the reoccupation of this nomadic people with animals in their environment. Usually only wild animals are represented. Commonly depicted are: stags and deer, lions or other large cats, eagles, birds heads (perhaps of ravens), griffins, snakes, hares, fish, goats, rams, boars, moose (elk), yak, sheep and bears. The occasional exception to the wild animal rule is domesticated horses-important because the Scythians were horse bleeders and their whole culture revolved around their dependence on the horse. The nomads had little reason to create object in honour of gods or men, but they had an instinct for beauty and the wish to surround themselves with the animal forms in which they had come to delight The Scytians tried to combine in a single rendering all the salient points of the animal they were delineating. They archived considerable success in the difficult task of showing in a single image the various and often incompatible poses assumed by a single animal in the course of its life. Zoomorphic motifs were used not simple for decorative effect, but to trim the object into amulets, with magical power to assist in hunting, and to protect the owner from harm.

  • PDF

The reliability of tablet computers in depicting maxillofacial radiographic landmarks

  • Tadinada, Aditya;Mahdian, Mina;Sheth, Sonam;Chandhoke, Taranpreet K;Gopalakrishna, Aadarsh;Potluri, Anitha;Yadav, Sumit
    • Imaging Science in Dentistry
    • /
    • v.45 no.3
    • /
    • pp.175-180
    • /
    • 2015
  • Purpose: This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). Materials and Methods: A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Results: Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Conclusion: Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.