• 제목/요약/키워드: Clamping Load

검색결과 82건 처리시간 0.028초

컨테이너 크레인용 쐐기형 레일 클램프의 쐐기각에 대한연구 (Study on the Wedge Angle of Wedge Type Rail Clamp for Container Crane)

  • 한근조;이호;심재준;한동섭;안찬우;전영환
    • 한국정밀공학회지
    • /
    • 제21권9호
    • /
    • pp.119-126
    • /
    • 2004
  • In this paper, we design a wedge type rail clamp which can protect container crane from a sudden strong blast with constant clamping force regardless of the operating period. When we design wedge type rail clamp, it is important to determine the angle of wedge and analyze a contact condition of roller and wedge so that we might develop a wedge type rail clamp for parking devices of port cargo working system with variable capacity. Therefore, this paper suggests a process to decide wedge angles within feasible range which could be obtained using load analysis and FEA of wedge type rail clamp

새로운 능동 클램핑방식을 이용한 연료전지용 DC-AC 인버터의 특성 (Characteristic of fuel Cell DC-AC Inverter Using New Active Clamping Method)

  • 김칠용;조만철;문상필;김영준;김홍삼
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.337-340
    • /
    • 2007
  • In the dissertation, a power conversion system for fuel cell is composed of a PWM inverter with LC filter in order to convert fuel cell voltage to a single phase 220[V], In addition, new insulated DC-DC converters are proposed in order that fuel cell voltage is boosted to 380[V]. In this paper, it requires smaller components than existing converters, which makes easy control. The proposed DC-DC converter controls output power by the adjustment of phase-shift width using switch S5 and S6 in the secondary switch, which provides 93-97[%] efficiency in the wide range of output voltage. Fuel cell simulator is implemented to show similar output characteristics to actual fuel cell. Appropriate dead time td enables soft switching to the range where the peak value of excitation current in a high frequency transformer is in accordance with current in the primary circuit. Moreover, appropriate setting to serial inductance La reduces communication loss arisen at light-load generator and serge voltage arisen at a secondary switch and serial diode. Finally, TMS320C31 board and EPLD using PWM switching technique to act a single phase full-bridge inverter which is planed to make alternating current suitable for household.

  • PDF

가토(家兎)에 있어서 Sulfadiazine의 뇨중(尿中) 배설기전(排泄機轉) (Mechanism of Urinary Excretion of Sulfadiazine in the Rabbit)

  • 고석태;정종남;고옥현
    • Journal of Pharmaceutical Investigation
    • /
    • 제2권1호
    • /
    • pp.18-30
    • /
    • 1972
  • Renal pathways for excretion of sulfadiazine has been studied by standard clearance technique in the rabbit. 1. Large part of sulfadiazine filtered in the glomeruli is reabsorbed in the tubules, as visualized from the fact that Csd (clearance of sulfadiazine) amounts only a fraction of simultaneously measured Ccr (GFR). 2. Csd changed linearly with the rate of urine flow, whether it is increased by the duir etics or decreased by clamping u reter. 3. Csd remained unchanged until the plasma level of the Csdremained unchanged drug reached 10.0 mg%, and the amount transported in the tubules increased linearly with the increase in the load, exhibiting No maximum capacity for transport. 4. Csd was increased by 2,4-dinitrophenol which is an uncoupling agent of oxidative phosphorylation and decreased by probenecid which is on uricosuric agent. 5. During sodium bicarbonate infusion net secretion of sulfadiazine by tubules observed. All the evidences obtained in the rabbit indicated that sulfadiazine was reabsorbed by active, energy-requiring, or passive, simple diffusion, process, and secreted simultaneously by a probenecid-sensitive, active procss.

  • PDF

소결온도에 따른 ZnO 바리스터의 내환경 특성 (Environmental Properties of ZnO Varistors with Variation of Sintering Temperature)

  • 이성갑;조현무;이종덕;박상만
    • 한국전기전자재료학회논문지
    • /
    • 제18권12호
    • /
    • pp.1111-1116
    • /
    • 2005
  • ZnO varistor ceramics added a glass-frit 0.03 $wt\%$ were fabricated with variation of sintering temperature. The sintering temperature and time were $1125^{\circ}C\~1200^{\circ}C$ and 2 h. The average grain sizes increased and the varistor voltage decreased with increasing the sintering temperature. The values of the specimen sintered at $1200^{\circ}C$ were $23.7\;{\mu}m$ and 329 V, respectively. The leakage current of all specimens was less than $1\;{\mu}A$ at DC $82\%$ of varistor voltage. The clamping voltage ratio of the specimen sintered at $1175^{\circ}C$ was 1.37. The endurance of surge current and the deviation of varistor voltage of the specimen sintered at $1175^{\circ}C$ were 6400 $A/cm^2$ and ${\Delta}-2.81\%$, respectively. After the High Temperature Load Test(HTLT) at $85^{\circ}C$ for 1000 h, the specimen sintered at $1175^{\circ}C$ showed the lowest deviation of varistor voltage of ${\Delta}-1.92\%$.

바리스터와 LC필터를 조합한 뇌써-지보호장치 (The Ligthning Surge Protective Devices with Combination of Varistor and LC Filter)

  • 김지훈;이경옥;이복희;이영근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1873-1875
    • /
    • 1996
  • This paper deals with the lightning surge protective devices with combination of varistor and LC filter. UP to now, the varistor alone were used as overvoltage protection devices fer the AC power mains. In this work, in order to improve the cutoff performance of surge protective device, the hybrid circuit surge protective device for an AC single phase mains was designed and investigated. The first stage of hybrid circuit is to remove most of any large surge energy and protect the second stage components. The purpose of the second is to protect the load and increase the cutoff capacity of surge protective devices. Also LC filter attenuates the remnant that travels downstream from the first stage component and the high frequency noises. As a consequence, it was found that the proposed hybrid surge protective device for AC power mains has a variety of advantages such as low and tight clamping voltage, high frequency noise reduction and large cutoff capacity.

  • PDF

실차 주행시험을 통한 디스크-패드 마찰계수 측정방법 (Measuring methods for friction coefficient of disc-pad through running test)

  • 목진용;김영국;김석원;박찬경;김기환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.996-1001
    • /
    • 2008
  • To stop the train safely within the limited traveling distance and reduce its speed to the desired speed, it is necessary to guarantee the correct braking force. Presently, most trains have electric propulsion system and have adopted combined electrical and mechanical(friction) braking system. The friction coefficient between brake disc and pad is an important parameter in determining the mechanical braking force. In general, friction coefficient data of braking material have been taken through the dynamo-test in a laboratory. This study have suggested two methodologies that can measure friction coefficient of braking material on the train's actual operating condition. The first is the direct method; measure the brake force and the clamping force applied on the mechanical brake by using strain gauges installed at the brake disk, and then calculate it. The second method is the indirect method; obtain the friction coefficient by using the train load and the equivalent brake force which is deducted the longitudinal force, such as resistance to motion, gradient resistance and curved resistance, from the inertia force applied to the train.

  • PDF

고주파 결합 인덕터 직렬 공진형 ZCS-PFM 초퍼 제어 방식을 이용한 새로운 승압형 DC-DC 컨버터 (A Novel Boost DC-DC Converter using High Frequency Coupled Inductor Series Resonant ZCS-PFM Chopper Control Method)

  • 김홍신;허영환;문상필;박한석
    • 전기학회논문지P
    • /
    • 제66권2호
    • /
    • pp.63-68
    • /
    • 2017
  • This paper proposes a new non-isolated DC conversion circuit topology of the voltage source coupled inductor series resonant high-frequency PFM controlled boost chopper type DC-DC power converter using two in one IGBT power module, which can efficiently operate under a principle of zero current soft switching for wide output regulation voltage setting ranges and wide fluctuation of the input DC side voltage as well as the load variation ranges. Its steady state operating principle and the output voltage regulation characteristics in the open-loop-based output voltage control scheme without PI controller loop are described and evaluated from theoretical and experimented viewpoints. Finally, in this paper the computer-aided simulation steady-state analysis and the experimental results are presented in order to prove the effectiveness and the validity of voltage regulation characteristics of the proposed series resonant zero current soft switching boost chopper type DC-DC power converter circuit using IGBTs which is based on simple pulse frequency modulation strategy more than, 20kHz.

High Temperature Fiber Fragmentation Characteristics of SiC Single-Fiber Composite With Titanium Matrices

  • Matikas, Theodore E.
    • Advanced Composite Materials
    • /
    • 제17권1호
    • /
    • pp.75-87
    • /
    • 2008
  • Aerospace structural applications, along with high performance marine and automotive applications, require high-strength efficiency, which can be achieved using metal matrix composites (MMCs). Rotating components, such as jet-engine blades and gas turbine parts, require materials that maximize strength efficiency and metallurgical stability at elevated temperatures. Titanium matrix composites (TMCs) are well suited in such applications, since they offer an enhanced resistance to temperature effects as well as corrosion resistance, in addition to optimum strength efficiency. The overall behavior of the composite system largly depends on the properties of the interface between fiber and matrix. Characterization of the fiber.matrix interface at operating temperatures is therefore essential for the developemt of these materials. The fiber fragmentation test shows good reproducibility of results in determining interface properties. This paper deals with the evaluation of fiber fragmentation characteristics in TMCs at elevated temperature and the results are compared with tests at ambient temperature. It was observed that tensile testing at $650^{\circ}C$ of single-fiber TMCs led to limited fiber fragmentation behavior. This indicates that the load transfer from the matrix to the fiber occurs due to interfacial friction, arising predominantly from mechanical clamping of the fiber by radial compressive residual and Poisson stresses. The present work also demonstrates that composite processing conditions can significantly affect the nature of the fiber.matrix interface and the resulting fragmentation of the fiber.

$Nb_2O_5$ 첨가에 따른 바리스터의 전기적 특성 (Electrical Properties of ZnO Varistors with variation of $Nb_2O_5$)

  • 조현무;이성갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.67-69
    • /
    • 2004
  • ZnO varistor ceramics which were fabricated with variation of added of 0.01, 0.02, 0.03, 0.05, 0.1mol% $Nb_2O_5$ sintered at $1150^{\circ}C$. In the specimen added 0.05mol% $Nb_2O_5$, sintered density was $5.87g/cm^3$ and electrical properties were superior to any other components. The nonlinear coefficient was 75, and clamping voltage ratio was 1.40. And, endurance surge current in the specimen added 0.05mol% $Nb_2O_5$ was $6500A/cm^2$, and deviation of varistor voltage was -1.7%. As P.C.T and T.C.T environment test were succeed in all specimens, and deviation of varistor voltage in the specimen added 0.3mol% $Nb_2O_5$ was -0.81%. All specimens showed a good leakage current property in the High Temperature Continuous Load Test for 1000hr, at $85^{\circ}C$, and variation rate of the varistor voltage was -1.71%.

  • PDF

Compact Wireless IPT System Using a Modified Voltage-fed Multi-resonant Class EF2 Inverter

  • Uddin, Mohammad Kamar;Mekhilef, Saad;Ramasamy, Gobbi
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.277-288
    • /
    • 2018
  • Wireless inductive power transfer (IPT) technology is used in many applications today. A compact and high-frequency primary side inverter is one of the most important parts of a WPT system. In this study, a modified class EF-type voltage-fed multi-resonant inverter has been proposed for WPT application at a frequency range of 85-100 kHz. Instead of an infinite input choke inductor, a resonant inductor is used to reduce loss and power density. The peak voltage stress across the MOSFET has been reduced to almost 60% from a class-E inverter using a passive clamping circuit. A simple yet effective design procedure has been presented to calculate the various component values of the proposed inverter. The overall system is simulated using MATLAB/SimPowerSystem to verify the theoretical concepts. A 500-W prototype was built and tested to validate the simulated results. The inverter exhibited 90% efficiency at nearly perfect alignment condition, and efficiency reduced gradually with the misalignment of WPT coils. The proposed inverter maintains zero-voltage switching (ZVS) during considerable load changes and possesses all the inherent advantages of class E-type inverters.