• Title/Summary/Keyword: City Gas

Search Result 568, Processing Time 0.024 seconds

A Study on the Energy Consumption Characteristic by Building Envelope of Apartment Housing in Busan Metropolitan City (부산광역시 공동주택의 외피구조에 따른 에너지 소비특성 분석)

  • Yee, Jurng-Jae;Kim, Hwan-Yong;Kim, Seung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.75-81
    • /
    • 2014
  • In this paper we made energy consumption units of glass curtain wall type apartment and general apartment in Busan metropolitan city and compared energy consumption characteristics by building envelope. The monthly electricity consumption units of general apartment were shown in the range of $1.16{\sim}1.51kWh/m^2{\cdot}mon$ which were indicated higher value in January, February, August and September with little variation. On the other hand, in case of glass curtain wall type apartment, monthly electricity consumption units were represented in the range of $1.91{\sim}7.07kWh/m^2{\cdot}mon$ with significant fluctuations monthly, which were outstandingly high in July, August and September. The monthly city gas consumption units of general apartment were found to be in the range of $1.79{\sim}18.07MJ/m^2{\cdot}mon$, while glass curtain wall type apartment were within $0.94{\sim}19.91MJ/m^2{\cdot}mon$. City gas consumption units from December to March were shown highly in both type apartments. The monthly energy consumption units of general apartment were found to be within $14.23{\sim}30.69MJ/m^2{\cdot}mon$, while glass curtain wall type apartment were within $24.49{\sim}68.9MJ/m^2{\cdot}mon$. Energy consumption units of glass curtain wall type apartment were suggested 4.84 times higher than those of general apartment.

A Simulation of Diffusion coefficients for electrons in $SF_6$-Ar Gas Mixtures (시뮬레이션에 의한 $SF_6$-Ar혼합기체의 확산계수)

  • Seong, Nak-Jin;Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.163-166
    • /
    • 2006
  • Energy distribution function for electrons in $SF_6$-Ar mixtures gas used by MCS-BEq algorithm has been analysed over the E/N range 30${\sim}$300(Td) by a two term Boltzmann equation and by a Monte Carlo Simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2(%) and 0.5(%) $SF_6$-Ar mixtures were measured by time-of-flight(TOF) method, The results show that the deduced longitudinal diffusion coefficients and transverse diffusion coefficients agree reasonably well with theoretical for a rang of E/N values The results obtained from Boltzmann equation method and Monte Carlo simulation have been compared with present and previously obtained data and respective set of electron collision cross sections of the molecules.

  • PDF

Energy Distribution Function for Electrons in $SF_6$+He mixtures gas used by MCS-BEq (MCS-BEq에 의한 $SF_6$-He 혼합기체의 에너지 분포함수)

  • Seong, Nak-Jin;Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.41-44
    • /
    • 2004
  • This paper describes the electron transport characteristics in $SF_6$-He gas calculated for range of E/N values from 50${\sim}$700[Td] by the Monte Carlo simulation(MCS) and Boltzmann equation(BEq) method using a set of electron collision cross sections determined by the authors and the values of electron swarm parameters are obtained by TOF method. The results gained that the values of the electron swarm parameters such as the electron drift velocity. the electron ionization or attachment coefficients. longitudinal and transverse diffusion coefficients agree with the experimental and theoretical for a range of E/N.

  • PDF

A Study on the Application of District Heating System using Sewage Source (하수열원을 이용한 지역난방 적용성 검토)

  • Kim, Sang-Hun;Kim, Dong-Jin;Choi, Dong-Kyoo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.928-933
    • /
    • 2009
  • The purpose of this study is to examine the energy consumption, carbon dioxide emission & energy cost of district heating using sewage source. The annual TOE of heat pump using sewage source save 37.1 percent than city gas boiler. And annual carbon dioxide emission of heat pump cut down 41.3 percent than city gas boiler. If it charges the rate schedule for district heating to apartment resident, collected amount are 3,127,170 thousand won. As energy cost of heat pump & circulation pump are 1,378,072 thousand won. the profits are 1,749,098 thousand won. As payback period is 8.97years, applicability is low level. However, it has advantages in energy consumption, carbon dioxide emission & energy cost. Therefore, it needs to proceed through government assistance.

  • PDF

A Study of Electron Transport properties in $SF_6+Ar$ Gas ($SF_6+Ar$의 전자수송계수에 관한 연구)

  • Park, Jae-Sae;Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2001.07e
    • /
    • pp.72-75
    • /
    • 2001
  • In this paper, we describe the results of a combined experimental theoretical study designed to understand and predict the dielectric properties of $SF_6$ and $SF_6+Ar$ mixtures. The electron transport, ionization, and attachment coefficients for pure $SF_6$ and gas mixtures containing $SF_6$ has been analysed over the E/N range $30{\sim}300Td$ by a two term Boltzrnann equation and by a Monte Carlo Simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2% and 0.5% $SF_6+Ar$ mixtures were measured by time- of- flight method, The results show that the deduced electron drift velocities, the electron ionization or attachment coefficients, longitudinal and transverse diffusion coefficients and mean energy agree reasonably well with the experimental and theoretical for a rang of E/N values.

  • PDF

A Study on Development of City Gas Safety Diagnosis System Index (도시가스 안전 진단 지표 개발에 관한 연구)

  • 정원익;양광모;전형정;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.1-4
    • /
    • 2004
  • Need safety diagnostic indicator pointer that is objective as estimation basis to be scientific and manages systematically safety existing condition and level for city gas facilities. Safety diagnostic indicator pointer can divide by greatly two. One is management (Software) side that one that differ with mechanical (Hardware) side that handle laying stress on equipment connected with safety manages organization and management connected with safety. Weight appropriates according to specific gravity that relevant element occupies in facilities. To give so big value in particular element in grant of weight pays attention because break balance of whole guideline and should gives. Finally, efficient safety net may see effect before self-regulation inside by minimum target establishment by government and legal, systematic countermeasure establishment for this, strict law application and each business proprietor and though activity and user's active safety activity forms harmony properly.

  • PDF

Fracture Characteristics of D 3507 and D 3631 City Gas Steel Pipes (도시가스용 D3507 및 D3631 강관의 파괴특성)

  • 박재학;김한국;신규인;김만원
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.39-46
    • /
    • 2001
  • It is noted that KS D 3507 pipe steel has several problems when it is used as a city gas pipe at medium pressure. So new pipe steel, KS D 3631, was developed in order to be used as a pipe for medium and low pressure and now it is being substituted for D 3507. In this study, several mechanical tests, such as tensile test, microhardness test, and Charpy impact test were conducted to get material properties of D 3507 and D 3631 pipe steels. And also microstructures at the weld and heat affected zones were observed for the two materials. From the Charpy test results $K_{IC}/$ was estimated for the upper and lower shelf and the critical crack length is calculated for supposed axial semi-elliptical surface cracks. And the burst pressure is estimated as a function of wear depth for a defective D 3631 pipe by using the finite element method. The burst pressure is also calculated for pipes with an axial crack by using the published equations.

  • PDF

${\gamma}-Fe_2O_3$ Thick Film City Gas Sensor (${\gamma}-Fe_2O_3$ 후막형 도시가스 감지 소자)

  • Choi, Dong-Han;Lee, Won-Kee;Lee, Duk-Donq;Sohn, Hyunq-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.477-480
    • /
    • 1987
  • ${\gamma}-Fe_2O_3$ thick film city gas sensors have been fabricated by using screen printing method. The sensitivity to $C_4H_{10}$ and, $CH_4$ was about 90% and 65% respectively. The devices heated in air at $400^{\circ}C$ for 1 hour exhibited the highest sensitivity (-90%) to $C_4H_{10}$ at the operating temperature of $300-350^{\circ}C$. And they had good selectivity for $C_4H_{10}$ in comparistion with other gases (CO, $H_2$, $C_3H_8$ etc).

  • PDF

Drift Velocities for Electrons in $SF_6$-Ar Mixtures Gas by Simulation (시뮬레이션을 이용한 $SF_6$-Ar혼합기체의 전자 이동속도)

  • Hwang, Cheong-Ho;Kim, Sang-Nam
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.451-452
    • /
    • 2007
  • Drift velocities for electrons in $SF_6$-Ar mixtures gas by simulation has been analysed over the EIN range 30~300[Td] by a two term Boltzmann equation and by a Monte Carlo Simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2[%] and 0.5[%] $SF_6$-Ar mixtures were measured by time-of-flight (TOF) method. The results show that the deduced electron drift velocities, the electron ionization or attachment coefficients. longitudinal and transverse diffusion coefficients and mean energy agree reasonably well with theoretical for a rang of E/N values.

  • PDF

An Experimental Study on the Improvement of City Gas Buried Double Piping Integrity (도시가스 매설이중배관 건전성 향상에 관한 실험적 연구)

  • Lim, Hyung-Duk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.5
    • /
    • pp.757-763
    • /
    • 2020
  • City gas buried pipes are managed by corrosion protection to prevent corrosion. In the case of the press-in section, the double pipe and the main pipe may cause corrosion under the influence of stray current, which can shorten the life of the pipes. In addition, if the insulator is filled in the press-in section, the press-in section itself is a single structure, and can be directly affected by external impact, and when the surrounding ground subsidence occurs, the stress may be concentrated, resulting in serious consequences. In this study, a serration-type shock absorber in the form of a sliding support was proposed as a new buried double piping construction method using EPS. The serration-type shock absorber can contribute to the improvement of the integrity of the buried double piping, as it can utilize the gas piping's own ductility and stress distribution characteristics with proper anti-corrosion management and shock-absorbing material properties by preventing contact inside the buried double pipe. However, for application to ground piping, there remains a task to supplement the vulnerability against fire due to the characteristics of EPS materials.