• Title/Summary/Keyword: City Gas

Search Result 571, Processing Time 0.029 seconds

Current Status of Solar Power Generation in Jinju City Close to the South Coast and Jeonju City Close to the West Coast

  • Kwang Pyo Hong;Yun-Hi Kim;Gi-Hwan Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.1
    • /
    • pp.62-69
    • /
    • 2023
  • Recently, renewable energy has been increasing in Korea to reduce greenhouse gas, and solar power generation, which accounts for the largest proportion of renewable energy, is noteworthy. The government policy will further increase solar power generation. In order to implement the policy, it is important to understand the current status of domestic solar power generation facilities. Therefore, the current status of solar power generation facilities in Jinju city close to the south coast and Jeonju city close to the west coast was investigated and compared. By 2020, 618 solar power plants had been installed in Jeonju city and 269 in Jinju city. However, there is not much difference in the amount of solar power generation for business at 9 GWh. The reason is that Jinju city has a lower population density than Jeonju city, so there are enough places to install a large-scale solar power facilities with a large power generation capacity. Monthly solar power generation was the highest in April in both Jeonju city and Jinju city and the lowest in January. In particular, in December, Jinju city showed more solar power generation than Jeonju city because of the large amount of insolation, long sunshine hours, and few clouds.

A study on Properties of Gas Generated at Closed Landfill Site (사용종료 매립지의 발생가스 특성분석에 관한 연구(I))

  • 장성호;손영일
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.2
    • /
    • pp.17-23
    • /
    • 2001
  • The objective of this study was to investigate the component ratio of gas generated at closed GD landfill site in MY city and the decomposition status of landfill gas, and was to examine and analyze the properties of the landfill gas. In addition, to provide basic data required to stabilize landfill earlier in the future, the study was to measure gas by landfill gas gauge and to analyze the properties of landfill gas based on documents. As a result of analyzing the properties, acquired follow results. 1. The main elements of landfill gas, $CH_4$ and $CO_2$ were respectively 25.02% and 22.325 on the average. 2. $NH_3$ and $H_2S$ were respectively 1.07 4.97 and 0.75 1.15 on the average. 3. Generated gas was different depending on water, pH properties of MSW(Munticipal Solid Wastes) and their decomposition rate. Furthermore, when measured the temperature of room to inspect landfill gas, the temperature was $22{\;}-{\;}30^{\circ}C$ in the average.

  • PDF

An Evaluation of EOCS Regarding Safety Management Effects on Buried Gas Pipelines and Convenience of the Excavators and the Operators of Gas Companies

  • Ryon, Young-Don;Chae, Chung-Keun;Bang, Hyo-Jung;Yoon, Young-Kee;Lee, Su-Kyung
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.43-48
    • /
    • 2007
  • We introduced the Excavation One Call System (EOCS) as a pilot system, in Seoul, Korea. The system utilizes the phone and internet to transfer information about digging underground and buried gas pipelines, although currently written forms are used in accordance with the City Gas Business Law. After one year, we evaluated the business model by surveying the excavators and the operators of the gas companies. This paper shows that the EOCS was more effective in preventing the buried gas pipelines from being damaged than the existing method that has to use due form. It also shows that the EOCS was more convenient and cost efficient than the present policies in place. We come to the conclusion that the EOCS should be extended nationwide and gradually include other subsurface facilities.

A Study on the Microstructure and Mechanical Properties for the Weldment with Variation of Welding Process of the API 5L-B42 Pipeline for Natural Gas Transmission (천연가스 수송용 API 5L-X42 강관의 용접방법에따른 용접부의 미세조직과 기계적 특성에 관한 연구)

  • Baek Jong-Hyun;Kim Cheol-Man;Kim Young-Pyo;Kim Woo-Sik
    • 한국가스학회:학술대회논문집
    • /
    • 1997.09a
    • /
    • pp.33-38
    • /
    • 1997
  • Demand of the clean and convenient natural gas has continuously increased with recognizing of the environment problem since liquefied natural gas was introduced in Korea. Clean fuel natural gas was supplied to each city through high tensile strength pipeline connected by welding. Grades of pipeline were divided into the high and middle pressure according to supply pressure. Pipeline was welded mainly SMA welding process due to its easy handling, the other welding process was adopted according to the constructing condition. We were examined on the microstructure variation and mechanical properties of weld metal for high pressure pipeline, API 5L X-42.

  • PDF

A Study on the Emission Characteristics of LNG-diesel Dual-fuel Engine for Euro 2 Standard (Euro 2 기준 LNG-경유 혼소엔진의 배출가스 특성에 관한 연구)

  • Cho, Gyu-Baek;Kim, Chong-Min;Kim, Dong-Sik;Kim, Hong-Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2011
  • Heavy duty diesel engine has relatively small portion of whole vehicles due to long drive distance and large engine displacement, but largely influences atmosphere environment. City buses changed to CNG (Compressed Natural Gas) bus with Korea-Japan Worldcup. Heavy duty truck and intercity bus, however, were impossible to use CNG because those kinds of vehicles had long drive distance and CNG station was installed mainly at the around of the bus garage of city. Insulation container storing the natural gas as a liquid makes heavy duty truck and intercity bus possible to use the natural gas. Drive using diesel is possible where is hard to recharge the gas. With LNG (Liquefied Natural Gas), the dependence on oil is largely decreased, PM (Particulate Matter) and NOx which is chronic disadvantage of diesel is remarkably reduced and finally $CO_2$, the representative green house gas, is reduced over 10%.

The study on the methane activation by a plasma (플라즈마 반응에 의한 메탄 활성화에 관한 연구)

  • Cho Won Ihl;Baek Young Soon;Kim Byung Il;Kim Young Chai
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.3
    • /
    • pp.60-69
    • /
    • 1998
  • Methane, the major constituent of natural gas, had been converted to higher hydrocarbons by microwave and radio-frequency plasma in vacuum condition. Methane had been activated to plasma by suppling high energy then converted to ethane, ethylene, acetylene. The direct conversion process of methane had produced few by-products and demanded low-energy. The plasma sources were microwave and radio-frequency. Two types of reactor had been used to activate methane. One is common single tubular-type reactor and the other is series coil-type reactor which used for the first time in this study. To produce more C2 products, methane had been converted by a plasma and catalyst. The results of this study could be used to study mechanism of plasma reaction of methane, design the plant-scale reactor.

  • PDF

A study on the Estimation of Standard Heating City Gas Consumption of Apartment Housing (공동주택의 난방용 도시가스 표준사용량 산정에 관한 연구)

  • Shim, Yun-Hee;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.89-97
    • /
    • 2006
  • Our Housing culture continuously changes for the correspondence to social development and changes of economy, and be developing. A massive apartment complex continuously increased, and According to this in our country heating energy consumption of a residential building is continuously increasing at country me whom was limited in order to raise efficient residential land use and diffusion ratio of house. If confirm an element to be able to reduce use of a heating energy, and there is saving possibility to parts of energy saving, this study will present the standard amount used with bases to the gas amount used for heating and Field Test data about room temperature. Execute simulation with building balance (public area, a plain), the gas amount useds such as incense of a building, indoor setting temperature ($^{\circ}C$), a position of an apartment house etc. to affect the energy amount used of a valuation object building of a variable through Field Test and research on the actual condition. Calculate the standard amount used of city gas for winter season heating of a comparative analysis apartment house to data value getting the above results through Field Test and simulations with bases.

Comparison of effects of spark timing and fuel ratio on engine efficiency and $NO_x$ emission for fuel of city gas and syngas($H_2$ and CO) (도시가스와 혼합가스($H_2$, CO) 적용 시 점화시기 및 공연비에 따른 발전효율 및 질소산화물 배출량 비교)

  • Jeong, Chul-Young;Lee, Kyung-Teak;Song, Soon-Ho;Chun, Kwang-Min;Nam, Sang-Ick
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.817-820
    • /
    • 2009
  • Research on usage of syngas produced by waste gasification is on going all around the world. Syngas which consists of $H_2$, CO, $CO_2$, $N_2$, has different combustion characteristics from current city gas; due to distinct flame propagation speed of the fuel, syngas has different spark timing and air fuel ratio at maximum generating efficiency. This is why finding both the optimum point of spark timing and air fuel ratio is so important in order to improve thermo efficiency and secure stable running of gas generated by relatively low heating value syngas. Moreover, since emission of $NO_x$ is strictly regulated, it is important to operate lean burn condition that reduces NOx emission.

  • PDF

The Intrinsic Safety Evaluation of Solar Photovoltaic Cell (태양전지셀의 본질안전 방폭성능 평가)

  • Lee, Chun-Ha;Jee, Seung-Wook;Kim, Si-Kuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.49-54
    • /
    • 2011
  • Now the world will regulate the CO2 emission due to environmental issues. For an alternative plan photovoltaic system is watched. So, photovoltaic system is trend of big city and it is mandatory for renovation of construction. Oil & gas filling station existed in city is suitable to found the photovoltaic system. But the general photovoltaic system in oil & gas filling station is difficult to found because it is classified into hazardous area. This paper evaluates intrinsic safety evaluation of solar cell for making basic data to found for the photovoltaic system on hazardous area. The intrinsic safety characteristic is evaluated by short-circuit ignition test using IEC type spark ignition test apparatus and temperature rising test. The result of short-circuit ignition test, propane-air mixture gas is exploded on condition that 4 solar cells(9[V], 90[mA]) are connected serially under insolation 800[W/$m^2$]. So, if a larger solar module will be used at oil & gas filling station than we were tested, it needs explosion proof. As the result of rising temperature test, the temperature rising due to short circuit is not so much, but when the temperature rises due to radiant heat, it demands careful consideration for environmental influence.

Determination of Stream Reaeration Coefficient Using Modified Gas Tracer Method (Modified Gas Tracer Method 를 이용한 하천 재폭기계수의 산정)

  • 조영준
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.4
    • /
    • pp.57-65
    • /
    • 1999
  • A modified gas tracer method was used to obtain reaeration coefficient from an artificial channel and a reach of Bokha stream, Ichon city. Propane was used as the tracer gas and Rhodamine-B dye as a dispersion and dulution tracer. Concentrations of propane in water sample were measured using a gas chromatograph and concentrationsof dye using UV-Spectrophotometer. To compare measured values with predicted values,commonly used 14 equations were selected . Results of this study suggested that the modified gas tracer method is a potentially useful procedure for th edetermination of reaeration cofficients. However, estimated reaeration coefficients from predictive equations were significantly different from that of this study. Therefore, when using predictive equations, careful selection of equation with consideration for hydraulic characteristics such as flow depth and average velocity, or use of newly derived predictive equation which is adequate for questioned stream would be needed.

  • PDF