• Title/Summary/Keyword: Circulation control

Search Result 644, Processing Time 0.024 seconds

Key Application Technologies of High Efficiency Power Quality Control Systems

  • Liu, Ding-Guo;Shuai, Zhi-Kang;Tu, Chun-Ming;Cheng, Ying;Luo, An
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.458-468
    • /
    • 2013
  • Large capacity reactive power compensation and harmonic control in the low-voltage grid of an enterprise, are important technical means to improve power quality and reduce power loss. In this paper, the principle of an efficient power quality controller is analyzed. Then, key application technologies of the HPQC which would influence the performances of the HPQC are studied. Based on an analysis of the harmonic shunt problem, a frequency dividing control strategy of the HPQC continuous subsystem is proposed. A parameter design method of the HPQC discrete subsystem and its installation method are also proposed to ensure the system compensation effect. HPQC systems have been designed for a copper foil plant. The effectiveness of this paper has been verified by the simulation and application results.

Quantitative analysis of 5-hydroxymethyl-2-furaldehyde (5-HMF) in the commercial Rehmanniae Radix Preparata

  • Kim, Ho-Kyoung;Jeon, Won-Kyung;Kim, Young-A;Ko, Byung-Seob
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.204.1-204.1
    • /
    • 2003
  • Rehmanniae Radix Preparata attributes good blood circulation and it has been used for the treatment of dizziness, men's sterility, excessive loss of blood and weakness. On the quality control of the commercial Rehmanniae Radix Preparata, quantitative determination of 5-hydroxymethyl-2-furaldehyde (5-HMF) using HPLC method has been conducted. Quantitative analysis of 5-HMF in Rehmanniae Radix Preparata showered average 0.121${\pm}$0.063% in 14 samples collected throughout the regions of Korea. Contents of loss on drying, residue on ignition and residue on acid insoluble ignition showered average 14.084${\pm}$2.804%, 3.415${\pm}$0.790% and 0.807${\pm}$0.474% respectively.

  • PDF

Monitoring of Heparin and Protamine Therapy by Activated Clotting Time During Open-Heart Surgery (개심술시 Activated Clotting Time 을 이용한 Heparin 및 Protamine 양 조절에 관한 임상적 관찰)

  • Kim, Chun-Dong;Lee, Sung-Haing
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.346-355
    • /
    • 1980
  • It has been proposed that wide individual variation in response to heparin be not considered in the conventional set protocol for the control of heparin and protamine during extracorporeal circulation. In this paper, two protocol of heparin and protamine therapy were compared to assess the role of the Activated Clotting Time [ACT] in relation to heparin, protamine, and postoperative blood loss and transfusion. The study groups consisted of the 31 patients [adults 15 and children 16] anticoagulated with the conventional heparin protocol and the 31 patients [adults 15 and children 16] anticoagulated with ACT protocol during extracorporeal circulation. In the conventional heparin protocol, two mg of heparin per kg was administered initially with an additional 0.75 mg of heparin per kg every 30 minutes of extracorporeal circulation, and reversal was accomplished with protamine in a dose of 1.5 times the total milligram of heparin. In the ACT protocol, two mg of heparin per kg was administered initially with an additional dose of heparin enough to reach an ACT of 480 seconds [within safe zone 300 to 600 seconds] from the patient`s dose response curve every 1 hour of extracorporeal circulation, and reversal was done with protamine in a dose of 1.3 times the milligram of the residual heparin. The results were summarized as follows. After a dose of 2 mg per kg of heparin, the patient`s ACT varied from 240 to 600 seconds in adults and from 240 t~ 660 seconds in children. In the ACT group the total amount of heparin administered was markedly reduced when compared to the conventional group, and less protamine was required to neutralize heparin. The dose of heparin administered decreased from 7.07 [SE 0.42] mg/kg of the conventional group to 4.92 [SE 0.32] mg/k8 of the ACT group in adults and from 10.17 [SE 1.15] mg/kg to 5.23 [SE 0.24] mg/kg in children, which represent 30.4% and 48.6% decrease respectively. The dose of protamine administered for reversal decreased from 10.6 [SE 0.63] mg/kg of the conventional group to 3.35 [SE 0.35] mg/kg of the ACT group in adults and from 15.7 [SE 1.70] mg/kg to 3.26 [SE 0.27] mg/kg in children, which represent 68.4% and 79.2% respectively. The ratio of protamine to heparin administered in the conventional group was 1.50:1 in adults and 1.54:1 in children, but in the ACT group 0.68:1 in adults and 0.62:1 in children. Postoperative blood loss and transfusion revealed no statistically significant difference between the two groups. Although six patients in the conventional group and one in the ACT group needed re-exploration for continuous hemorrhage, no case of generalized oozing was encountered, and in each case a definite bleeding site was identified. Author would like emphasizing the value of the ACT protocol in controlling heparin and protamine administration during extracorporeal circulation.

  • PDF

Development of the Control System for the Motor-Driven Electromechanical Total Artificial Hearta

  • Kim, Hee-Chan;Lee, Sang-Hun;Kim, Jong-Won-;Kim, Jin-Tae-;Min, Byoung-Goo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.858-863
    • /
    • 1988
  • A micro-processor based control system for a brushless DC motor used in the motor-driven electromechanical total artificial heart was developed. Functionally, the control system is composed of two parts. The first part is the velocity and position controller to assure that the motor follows a predetermined optimal velocity profile with minimal energy consumption, and to guarantee the full stroke length. This part also utilize the passive adaptive control method to be robust against the load disturbance, system parameter variation, and uncertainty which is the environment of artificial heart system. The pump output control is the second part, and this part provides the required responses of the artificial heart to the time-varying physiologic demands. The basic requirements of these responses are preload sensitivity, afterload insensitivity, and the balanced ventricular outputs. The performance and reliability of this control system was evaluated through a series of mock circulation tests and animal implantation, and the results are very encouraging.

  • PDF

Computational Study on the Hemodynamics of Cardiovascular System Including Short-term Auto-regulation Functions (단기적 자율조절기능을 포함하는 심혈관계 혈류역학 모델링에 관한 수치적 연구)

  • 심은보;정찬일;최한고
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.393-402
    • /
    • 2001
  • A computational model representative of cardiovascular circulation was built using 12 standard lumped compartments. Especially, both the baroreceptor reflex and the cardiopulmonary reflex control model were implemented to explain the auto-regulation of cardiovascular system. Another important aspect of this model is to utilize the impulse-response curve of the nerve system in transferring the impulse error signals to autonomous nerve system. For the verification of this model, we have computed the normal hemodynamic conditions and compared those with the clinical data. Then. hemodynamic shock of 20% hemorrhage to cardiovascular system was simulated to test the effects of the control system model. The results of these two simulations were well matched with the experimental ones. The steady state LBNP simulation was also performed. The transient changes of hemodynamic variables due to ramp increase of bias pressure of LBNP showed good agreement with the physiological experiments. Numerical solution using only the baroreflex model showed relatively a larger deviation from the experimental data. compared with the one using the control model haying both the baroreflex and the cardiopulmonary reflex systems, which shows an important role of the cardiopulmonary reflex system for the simulation of the hemodynamic behavior of the cardiovascular system .

  • PDF

Temperature distribution in VX-2 hepatoma heated with thermoseed hyperthermia (열소자 온열요법시 VX-2 hepatoma내의 온도 변화에 대한 연구)

  • Choi, Ihl-Bohng;Bahk, Yong-Whee
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.295-300
    • /
    • 1994
  • It was the purpose of present study to develop a new thermoseed for heating deep-seated tumors and assessment of the effect of magnetic control on thermoseeds. Aqueous suspension of iron micro spheres (Ferropolysaccharide) was injected directly into the VX-2 hepatoma and heated with 1.2 MHz inductive radiofrequency unit. Aqueous thermoseed suspension was delivered to the tumor by simple percutaneous injection. The limitation of the thermoseed heating method is the positional change of thermoseed particles in the tumor after implantation. The thermoseed particles could enter the systemic blood circulation and cause a severe embolization of a critical organ. To minimize this limitation, we have used the magnetic control after loading the thermoseed in the tumor, W hen ferropolysaccharides were exposed to a strong magnetic field, they magnetized and subsequently exerted a magnetic force on each other, forming larger aggregates of particles. The size of aggregated Particles were too big to enter the systemic blood circulation. Thus, unlike other thermoseed method, we hold the thermoseed particles stationary in the tumor. The temperature of the injected site and immediate vicinity elevated by $4-5^{\circ}C$. The temperature of the surrounding normal hepatic tissue elevated by $1-2^{circ}C$ only. The heating effect within the tumor was variable depending on the density of ferromagnetic aqueous suspension. Our results suggest that inductive heating of tumor injected with ferropolysaccharide solution offers the possibility of effective heat delivery to the defined tumor volume, which is difficult to heat with other heating devices.

  • PDF

On the Lift Enhancement Technique of the Trailing Edge Rotor of Two Dimensional Hydrofoil (날개 끝 회전자를 이용한 양력강화기법에 관한 연구)

  • Oh, Jung-Keun;Noh, Jackyou
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.2
    • /
    • pp.200-206
    • /
    • 2015
  • In order to verify the lift enhancement of the 2D hydrofoil with trailing edge rotor and check the ability of its practical use, experimental studies were conducted in the caviation tunnel using the test model with NACA0020 section. The three-component forces acting on the model could be measured by exclusively designed sting type multi-component load cell. The trailing edge of the model has been replaced with rotor which could be controlled by DC servo motor installed at the exterior of the tunnel. A typical effect of the trailing edge rotor has been introduced among the systematic experiments on various angular deviation of the model and the rotational velocity of the trailing edge rotor. It is appeared that the circulation control effect could be easily adjusted by selecting the rotational velocity of the trailing edge rotor and the lift force was augmented more than two times. Thus the proposed lifting device could be utilized as a novel high lifting device which has adjustability of lift force.

Comparative analysis on environment control systems for glasshouses and plastic houses (유리온실과 플라스틱 온실의 환경조절시스템 비교분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho;Seo, Dong-Uk;Yu, In-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.3
    • /
    • pp.251-258
    • /
    • 2014
  • In order to set up the basic environmental control systems which the new concept greenhouses have to equip, greenhouse characteristics, environmental management and control systems in domestic glasshouses and plastic houses were investigated and analyzed comparatively. Survey results on the width, length, eaves height, and the number of spans etc. showed that glasshouses were bigger than plastic houses significantly. New concept greenhouses claim to be plastic houses, but it will be reasonable to follow the specifications of the glasshouse. Specifications to be applied to new concept greenhouses were proposed as follows; hot water heating systems, aluminum screens as the thermal curtain, evaporative cooling systems, roof vents on the ridge, circulation fans, $CO_2$ enrichment, hydroponic systems, and automatic irrigation control systems. Environmental measurement systems for the indoor and outdoor temperature, humidity, light, wind speed and indoor $CO_2$ concentration have to be fully equipped. The automatic control system has to be as a complex environmental control system, not a single item control system. Also, for stable dissemination, domestically producing complete greenhouse control system should be made as soon as possible.

Bile Acid Inhibition of N-type Calcium Channel Currents from Sympathetic Ganglion Neurons

  • Lee, Hye-Kyung;Lee, Kyoung-Hwa;Cho, Eui-Sic
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.1
    • /
    • pp.25-30
    • /
    • 2012
  • Under some pathological conditions as bile flow obstruction or liver diseases with the enterohepatic circulation being disrupted, regurgitation of bile acids into the systemic circulation occurs and the plasma level of bile acids increases. Bile acids in circulation may affect the nervous system. We examined this possibility by studying the effects of bile acids on gating of neuronal (N)-type $Ca^{2+}$ channel that is essential for neurotransmitter release at synapses of the peripheral and central nervous system. N-type $Ca^{2+}$ channel currents were recorded from bullfrog sympathetic neuron under a cell-attached mode using 100 mM $Ba^{2+}$ as a charge carrier. Cholic acid (CA, $10^{-6}M$) that is relatively hydrophilic thus less cytotoxic was included in the pipette solution. CA suppressed the open probability of N-type $Ca^{2+}$ channel, which appeared to be due to an increase in (no activity) sweeps. For example, the proportion of sweep in the presence of CA was ~40% at +40 mV as compared with ~8% in the control recorded without CA. Other single channel properties including slope conductance, single channel current amplitude, open and shut times were not significantly affected by CA being present. The results suggest that CA could modulate N-type $Ca^{2+}$ channel gating at a concentration as low as $10^{-6}M$. Bile acids have been shown to activate nonselective cation conductance and depolarize the cell membrane. Under pathological conditions with increased circulating bile acids, CA suppression of N-type $Ca^{2+}$ channel function may be beneficial against overexcitation of the synapses.

A Study on the Improvement of Digital Library System for School Library (학교도서관업무지원시스템(DLS) 개선방안에 관한 연구)

  • Byun, Woo-Yeoul;Lee, Mihwa
    • Journal of the Korean Society for information Management
    • /
    • v.34 no.1
    • /
    • pp.31-50
    • /
    • 2017
  • This study was to suggest the problems and the improvement plan of Digital Library System (DLS) which has solved the library management and has supported the data building for resource sharing in school libraries since 2001. The 9 DLS committees were interviewed about the current situation of DLS use and the problems of DLS system in the 6 areas of acquisition, cataloging, circulation and discharge, inventory, library statistics, and searching interface as the research methods. Based on the interviews, the improvement plans were suggested as followed. In acquisition, it was to need the acquisition system development and online purchase for users. In cataloging, the improvement of data quality management, and indexes and vocabularies control for upgrade of searching function were needed. The advanced circulation speed in circulation, the restoration of discarded data in inventory and the exact statistic data in library statistics were need to improve the DLS. This study would contribute to the betterment of DLS and increase the use of DLS.