• 제목/요약/키워드: Circulation Rate

검색결과 749건 처리시간 0.028초

Research on heat transfer coefficient of supercritical water based on factorial and correspondence analysis

  • Xiang, Feng;Tao, Zhou;Jialei, Zhang;Boya, Zhang;Dongliang, Ma
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1409-1416
    • /
    • 2020
  • The study of heat transfer coefficient of supercritical water plays an important role in improving the heat transfer efficiency of the reactor. Taking the supercritical natural circulation experimental bench as the research object, the effects of power, flow, pipe diameter and mainstream temperature on the heat transfer coefficient of supercritical water were studied. At the same time, the experimental data of Chen Yuzhou's supercritical water heat transfer coefficient was collected. Through the factorial design method, the influence of different factors and their interactions on the heat transfer coefficient of supercritical water is analyzed. Through the corresponding analysis method, the influencing factors of different levels of heat transfer coefficient are analyzed. It can be found: Except for the effects of flow rate, power, power-temperature and temperature, the influence of other factors on the natural circulation heat transfer coefficient of supercritical water is negligible. When the heat transfer coefficient is low, it is mainly affected by the pipe diameter. As the heat transfer coefficient is further increased, it is mainly affected by temperature and power. When the heat transfer coefficient is at a large level, the influence of the flow rate is the largest at this time.

2탑 유동층 시스템에서 선택적 고체순환을 위한 고체분리기 개발 (Development of Solid Separator for Selective Solid Circulation in Two-interconnected Fluidized Beds System)

  • 류호정;박영철;이승용;김홍기
    • Korean Chemical Engineering Research
    • /
    • 제47권2호
    • /
    • pp.195-202
    • /
    • 2009
  • 선택적 고체순환이 가능한 2탑 유동층 공정 개발을 위한 기초연구로 금속 망이 장착된 입자크기분리 시스템에 의해 입자크기 차이를 이용하여 고운입자와 굵은입자를 분리할 수 있는 고체분리기를 개발하였으며 고체분리속도에 미치는 유속, 고체분리기의 설치높이 및 분리면적의 영향을 측정 및 고찰하였다. 고체분리기에 의한 고체분리속도는 기체유속, 고체분리기의 설치높이, 분리면적이 증가함에 따라 증가하였다. 기체유속 및 고체분리기 설치높이 증가에 따른 고체분리속도의 변화경향은 기포크기의 변화경향과 유사하였다. 본 연구에서 개발한 고체분리기를 이용하여 굵은입자($212{\sim}300{\mu}m$)와 고운입자($63{\sim}106{\mu}m$)의 분리가 가능하였으며 고체분리속도는 4.4~127 g/min의 범위를 나타내었다. 개발된 고체분리기를 회수증진 수성가스변환 공정에 적용하여 선택적 고체순환이 가능한 2탑 유동층 공정구성을 제안하였다.

연소 전 CO2 포집 흡수제들의 마모특성 (The Characteristics of Attrition of Absorbents for Pre-combustion CO2 Capture)

  • 류호정;이동호;문종호;박영철;조성호
    • 한국수소및신에너지학회논문집
    • /
    • 제24권5호
    • /
    • pp.428-436
    • /
    • 2013
  • Attrition characteristics of $CO_2$ absorbents for pre-combustion $CO_2$ capture were investigated to check attrition loss of those absorbents and to determine solid circulation direction and the better $CO_2$ absorbent. The cumulative attrition losses of two absorbents increased with increasing time. However, attrition loss under a humidified condition was lower than that under a non-humidified condition case. Between two absorbents, attrition loss of PKM1-SU absorbent was higher than that of P4-600 absorbent. The average particle sizes of the attrited particles were less than $2.5{\mu}m$ for two absorbents under a non-humidified condition case, and therefore, we could conclude that the main mechanism of attrition for two absorbents is not fragmentation but abrasion. Based on the results from the test for the effect of humidity on the attrition loss, we selected solid circulation direction from SEWGS reactor to regeneration reactor because the SEWGS reactor contains more water vapor than regeneration reactor. Attrition loss and make-up rate of two absorbents were compared based on the results from $CO_2$ sorption capacity tests and attrition tests. Required make-up rate of P4-600 absorbent was lower than that of PKM1-SU absorbent. However, more detail investigation on the optimum regeneration temperature, manufacturing cost, solid circulation rate, regeneration rate, and long-term sorption capacity should be considered to select the best $CO_2$ absorbent.

해수교환시스템의 수질향상 효율평가 (Efficiency Tests of Seawater Exchange System for Enhancement of Seawater Quality)

  • 장창환;김상택;김효섭;김규한;송만순
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제13권3호
    • /
    • pp.206-215
    • /
    • 2010
  • 주문진항의 해수교환율을 증대시킬 목적으로 기존의 해수교환방파제에 원거리 방류가 가능하도록 다기수로를 설치하였다. 원거리 방류가 가능한 해수교환시스템의 성능을 평가하기 위해서 총 4개의 CASE를 선정하여 수리모형 실험과 수치모형실험을 실시하였고, 항내수역의 해수순환 양상과 해수교환율을 비교 및 분석하였다. 실험결과 기존의 해수교환방파제(CASE 1)를 통하여 유입된 해수는 정체수역의 발생으로 전체 해수교환율이 48%로 측정되었다. 반면, 원거리 방류가 가능한 해수교환시스템은 해수순환이 원활하지 않은 정체수역까지 외해수를 전달하여 CASE 2, CASE 3, 그리고 CASE 4의 경우 전체 해수교환율은 CASE 1에 비교하여 각각 19%, 15%, 그리고 17%가 향상되었다.

다양한 아민 흡수제를 이용한 천연가스 중에 포함되어 있는 산성가스 제거 성능 비교 (Comparison of Removal Capabilities among Several Aqueous Amine Absorbents for Sweeting Acid Gases Contained in Natural Gas)

  • 조두희;김동선;조정호
    • 플랜트 저널
    • /
    • 제10권1호
    • /
    • pp.34-39
    • /
    • 2014
  • 본 연구에서는 상용성 공정모사기인 BR&E사의 PROMAX를 사용하여 amine류 흡수제인 30 wt%의 MEA수용액, 30 wt%의 DEA수용액 그리고 50 wt%의 MDEA수용액과 50 wt%의 MDEA에 첨가제로써 3 wt%의 piperazine을 첨가한 공정을 이용하여 천연가스 중에 포함되어 있는 산성가스인 $CO_2$$H_2S$ 성분의 제거 성능에 대한 비교 작업을 수행하였다. 공정모사 결과로 MEA는 상대적으로 많은 $CO_2$를 제거 할 수 있는 반면에 DEA, MDEA, MDEA와 첨가제인 piperazine은 $H_2S$를 많이 제거한다는 것을 알 수 있었고, MEA 30 wt%수용액의 경우는 lean amine의 circulation rate가 가장 적은 것으로 나타냈다. 재비기의 heat duty는 MDEA 50 wt%에 첨가제인 piperazine 3 wt% 수용액이 가장 적음을 알 수 있었다. 또한 MDEA 그리고 MDEA와 첨가제인 piperazine을 비교해 보면 첨가제로 인하여 solvent circulation rate가 감소된 것을 알 수 있었다.

  • PDF

극저온냉동기를 이용한 자연순환 루프의 실험 (Experiment of Natural Circulation Loop Using a Cryocooler)

  • 김민지;장호명
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2194-2199
    • /
    • 2007
  • An experimental study is performed to investigate the thermal and flow characteristics of subcooled liquid nitrogen in a natural circulation loop. Experimental apparatus is designed and constructed such that a closed loop is cooled at the top by a cryocooler and heated nearly at the bottom by cartridge heaters. Steady state is obtained by controlling the heating power to the cartridge heaters and a thin-film heater to reduce the cooling power of the cryocooler. Temperature is measured at several locations of the loop and the mass flow rate through the loop is estimated from the energy balance in terms of the measured temperatures. Experiment is repeated for various values of the vertical height between the cooling and heating parts. The results show that the heat transfer capability of the loop has a maximum at a certain value of height. The optimal height to maximize the heat transfer is in a good agreement with analytical prediction to take into account the buoyancy and viscous forces in the loop.

  • PDF

동중국해 표층수온의 장기 변동성: 종설 (Long-term Variability of Sea Surface Temperature in the East China Sea: A Review)

  • 이재학;김철호
    • Ocean and Polar Research
    • /
    • 제35권2호
    • /
    • pp.171-179
    • /
    • 2013
  • The long-term variability of sea surface temperature in the East China Sea was reviewed based mainly on published literatures. Though the quantitative results are not the same, it is generally shown that sea surface temperature is increasing especially in recent years with the rate of increase about $0.03^{\circ}C$/year. Other meaningful results presented in the literatures is that the difference of water properties between layers upper and lower than the thermocline in summer shows an increasing trend both in temperature and salinity, suggesting that the stratification has been intensified. As a mechanism by which to evaluate the wintertime warming trend in the region, the weakening of wind strength, which is related to the variation of sea level pressure and atmospheric circulation in the western North Pacific and northern Asian continent, is suggested in the most of related studies.

유로저항에따른 속도제어를 통한 Zone별 유량특성 연구 (A Study of Flow Characteristics through the Speed Control and Flow Resistance)

  • 오병길;김회서
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.762-768
    • /
    • 2011
  • We use floor radiant heating system in the house of commons in winter Floor radiant heating system, which transfer heat by radiation, is one of the energy efficient and comfortable systems that. Floor radiant heating system is configured to be controlled by the room for energy-saving. Proper flow rate to a comfortable heating in the room is important. However, Using a constant speed circulation pump in separate rooms, heating system may cause an imbalance because of the difference of length of coil when operating in the rooms. In this study, our Research team examined heating imbalance due to the variation length through the coil length changes and flow control of the circulation pump.

Effect of Liquid Circulation Velocity and Cell Density on the Growth of Parietochloris incisa in Flat Plate Photobioreactors

  • Changhai Wang;Yingying Sun;Ronglian Xing;Liqin Sun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제10권2호
    • /
    • pp.103-108
    • /
    • 2005
  • For more accurately describing the durations of the light and the dark phases of micro-algal cells over the whole light-dark cycle, and probing into the relationship between the liquid circulation time or velocity, the aeration rate and cell density, a series of experiments was carried out in 10 cm light-path flat plate photobioreactors. The results indicated that the liquid flow in the flat plate photobioreactor could be described by liquid dynamic equations, and a high biomass output, higher content and productivity of arachidonic acid, $70.10\;gm^{-2}d^{-1},\;9.62\%$ and 510.3 mg/L, respectively, were obtained under the optimal culture conditions.

백화점 매장계획을 위한 VMD와 고객동선의 상관관계에 관한 분석적 연구 (A Study on the Correlation between Customer's Circulation and VMD in Planning the Interior of Department Stores)

  • 최영신;차소란;임채진
    • 한국실내디자인학회논문집
    • /
    • 제32호
    • /
    • pp.121-130
    • /
    • 2002
  • At the large commercial facilities, people try to grasp a customer's needs as the marketing strategies for effective management and maximization of profits as well as the primary purpose for functional and effective spatial plan. In planning the interior of each department, they try to provide the image of the interior environment corresponding to customer's emotional needs. And this kind of efforts also have been improved as visual merchandising strategies based on the transmission of visual information. This study is to examine the correlation among customer's behavior, circulation and VMD by gasping their shopping patterns at the department stores based on the spatial and emotional approach to form an environmental image of each department. The researcher focused on time, speed and rate of shopping that show customer's behavioristic characteristics and examine the factors to have an influence on decision making. With the result, this study proposes the primary data and evidence for MD planning, circulation planning and VMD planning of each department.