• Title/Summary/Keyword: Circularly polarized

Search Result 165, Processing Time 0.02 seconds

XAS Studies of Ion Irradaited MgO Thin Films

  • Suk, Jae-Kwon;Gautam, Sanjeev;Song, Jin-Ho;Lee, Jae-Yong;Kim, Jae-Yeoul;Kim, Joon-Kon;Song, Jong-Han;Chae, Keun-Hwa
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.312-312
    • /
    • 2012
  • Magnesium oxide has become focus for research activities due to its use in magnetic tunnel junctions and for understanding of do ferromagnetism. Theoretical investigations on such type of system indicate that the presence of defects greater than a threshold value is responsible for the magnetic behaviour. It has also been shown experimentally that by decreasing the film thickness and size of nanoparticles, enhancement/increase in magnetization can be achieved. Apart from the change in dimension, swift heavy ions (SHI) are well known for creating defects and modifying the properties of the materials. In the present work, we have studied the irradiation induced effects in magnesium oxide thin film deposited on quartz substrate via X-ray absorption spectroscopy (XAS). Magnesium oxide thin films of thickness 50nm were deposited on quartz substrate by using e-beam evaporation method. These films were irradiated by 200 MeV Ag15+ ion beam at fluence of $1{\times}10^{11}$, $5{\times}10^{11}$, $1{\times}10^{12}$, $3{\times}10^{12}$ and $5{\times}10^{12}ions/cm^2$ at Nuclear Science Centre, IUAC, New Delhi (India). The grain size was observed (as studied by AFM) to be decreased from 37 nm (pristine film) to 23 nm ($1{\times}10^{12}ions/cm^2$) and thereafter it increases upto a fluence of $5{\times}10^{12}ions/cm^2$. The electronic structure of the system has been investigated by X-ray absorption spectroscopy (XAS) measurements performed at the high energy spherical grating monochromator 20A1 XAS (HSGM) beamline in the National Synchrotron Radiation Research Center (NSRRC), Taiwan. Oxides of light elements like MgO/ZnO possess many unique physical properties with potentials for novel application in various fields. These irradiated thin films are also studied with different polarization (left and right circularly polarized) of incident x-ray beam at 05B3 EPU- Soft x-ray scattering beamline of NSRRC. The detailed analysis of observed results in the wake of existing theories is discussed.

  • PDF

-1 Mode Circular Polarization Antenna Design by Using Cross Aperture-Coupled Feed (십자 개구 결합 급전을 이용한 -1 모드 원형 편파 안테나)

  • Kim, Jun-Sik;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.156-163
    • /
    • 2014
  • In this paper, a compact circularly polarized metamaterial patch antenna using cross aperture-coupled feed is proposed. The CP antenna utilizes the -1 mode that is induced by the composit right-left handed(CRLH) transmission line. Since the -1 mode has the same properties with the $TM_{010}$ mode of the conventional patch antenna, the circular polarization(CP) can be realized. If two orthogonal modes are excited with $90^{\circ}$ phase difference, the CP property can be obtained. In order to obtain two orthogonal modes and $90^{\circ}$ phase difference, 4 mushroom structures having the shape of square are employed. The width and length of the cross aperture are optimized through the design algorithm. The fabricated antenna is based on RT/duroid5880 substrate and the total area of the 4 mushroom is $0.25{\lambda}_0{\times}0.25{\lambda}_0$. The center frequency of the LHCP(Left-Handed Circular Polarization) antenna is measured as 1.622 GHz and circular polarization bandwidth(3 dB) is measured as 3 MHz. The center frequency of the RHCP(Right-Handed Circular Polarization) antenna is measured as 1.609 GHz and circular polarization bandwidth (3 dB) is measured as 3 MHz, respectively. The measured radiation efficiency of LHCP antenna is 61.1 % and the measured radiation efficiency of RHCP antenna is 54.5 %.

A Polarization-Switchable Microstrip Patch Antenna Using Corner Slots on Ground Plane and PIN Diodes (모서리 접지면 슬롯과 PIN 다이오드를 이용한 편파 변환 마이크로스트립 안테나)

  • Park, Chul-Woo;Lee, Tae-Hak;Choi, Jun-Ho;Yoon, Won-Sang;Pyo, Seong-Min;Kim, Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.769-777
    • /
    • 2010
  • In this paper, a switchable circularly polarized microstrip patch antenna using PIN diodes and corner slots on ground plane is proposed at 2.4 GHz. The proposed antenna has a square microstrip patch and ground plane that consists of two pair of slots and PIN diodes. The electrical lengths of the slots are adjusted by using the switching characteristic of the PIN diode, so the polarization of the proposed antenna can be switchable between linear, left-handed(LH) and right-handed(RH). By separating the ground plane for the DC bias, the size reduction effect is also obtained. When the proposed antenna is operated as linear polarization, the return loss and impedance bandwidth are 15 dB, 59 MHz, and when operated as LH and RH polarization, the minimum axial ratio and 3-dB axial ratio bandwidth are 1.17 dB, 1.67 dB, 28 MHz, and 32 MHz, respectively.

A Study on the Design of Wideband Microstrip Cross Slot Array Antennas with Circular Polarization (원편파용 광대역 마이크로스트립 크로스 슬롯 어레이 안테나의 설계에 관한 연구)

  • Min, Kyeoung-sik;Ko, Jee-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.4
    • /
    • pp.894-900
    • /
    • 2004
  • There are many types of circularly polarized(CP) microstrip antenna elements, which are used as a good unit radiator. Since an advantage of CP antenna is no strict alignment requirements between Rx and Tx system, the printed antennas with circular polarization are very often used in numerous satellite and mobile radio systems. In order to realize the broad bandwidth of 3 dB axial ratio and impedance of CP microstrip antenna, complex feed structure and tri-plate patch element have been researched. This paper describes a design of wideband microstrip cross slot array antennas with circular polarization. The proposed antenna is composed of an open-ended microstrip feed line as a feeder and a cross slot as a radiator for circular polarization. To realize the wide bandwidth, tri-plate structure are considered and cross slot is electromagnetically coupled with feed line. Optimum parameters of 1-element cross slot antenna are analyzed and designed by method of moments. These parameters are also applied to may antennas design considered the mutual coupling between radiating elements. Right hand circular polarization(RHCP) and left hand circular polarization(LHCP) of the proposed antenna are easily controlled by asymmetrical cross slot structure and slot position. In 1-element and 15-element cross slot array antenna, the good axial ratio of 1 dB below and the broad bandwidth characteristics of antenna are obtained.

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF