Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest (동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

A Robust Fingerprint Matching System Using Orientation Features

  • Kumar, Ravinder;Chandra, Pravin;Hanmandlu, Madasu
    • Journal of Information Processing Systems
    • /
    • v.12 no.1
    • /
    • pp.83-99
    • /
    • 2016
  • The latest research on the image-based fingerprint matching approaches indicates that they are less complex than the minutiae-based approaches when it comes to dealing with low quality images. Most of the approaches in the literature are not robust to fingerprint rotation and translation. In this paper, we develop a robust fingerprint matching system by extracting the circular region of interest (ROI) of a radius of 50 pixels centered at the core point. Maximizing their orientation correlation aligns two fingerprints that are to be matched. The modified Euclidean distance computed between the extracted orientation features of the sample and query images is used for matching. Extensive experiments were conducted over four benchmark fingerprint datasets of FVC2002 and two other proprietary databases of RFVC 2002 and the AITDB. The experimental results show the superiority of our proposed method over the well-known image-based approaches in the literature.

Effect of the slice thickness and the size of region of interest on CT number (상층두께와 관심영역의 크기 변화가 CT 번호에 미치는 영향)

  • Lee Ji-Youn;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.31 no.2
    • /
    • pp.85-91
    • /
    • 2001
  • Purpose: To evaluate the effect of the slice thickness and the size of region of interest (ROI) on CT number using quantitative CT phantom Materials and Methods: The phantom containing 150 mg/cc, 75 mg/cc and 0 mg/cc calcium hydroxyapatite was scanned with 1, 3, 5 and 10 mm slice thicknesses by single energy quantitative computed tomography (QCT). CT numbers were measured on center position of the phantom. Shape of ROI was circular and sizes were 1, 3, 5, 11, 16, 21, 26 and 33 mm². ANOVA and Tukey's multiple comparison method were performed for statistical comparison of CT numbers according to different slice thicknesses. Coefficient of variation of CT number measured in each size of ROI was evaluated in same slice thickness. Results : CT numbers had statistically significant difference according to slice thicknesses (p<0.05). As the slice thickness increased, CT number also increased. As the density of phantom became lower and the size of ROI became smaller, the coefficient of variation of CT number increased. When the size of ROI was more than 11 mm² in 1 mm slice thickness, 5 mm² in 3 mm slice thickness and 3 mm² in 5 mm slice thickness, the coefficient of variation became consistent. In 10 mm slice thickness, the size of ROI had little effect on the coefficient of variation. Conclusion: CT number had variation according to the slice thickness and the size of ROI although the object was homogeneous. The slice thickness and the size of ROI are critical factors in precision of the CT number measurements.

  • PDF

3D Shape Reconstruction using the Focus Estimator Value from Multi-Focus Cell Images (다초점 세포 영상으로부터 추정된 초점 값을 이용한 3차원 형태 복원)

  • Choi, Yea-Jun;Lee, Dong-Woo;Kim, Myoung-Hee;Choi, Soo-Mi
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.4
    • /
    • pp.31-40
    • /
    • 2017
  • As 3D cell culture has recently become possible, it has been able to observe a 3D shape of cell and volume. Generally, 3D information of a cell should be observed with a special microscope such as a confocal microscope or an electron microscope. However, a confocal microscope is more expensive than a conventional microscope and takes longer time to capture images. Therefore, there is a need for a method that can reconstruct the 3D shape of cells using a common microscope. In this paper, we propose a method of reconstructing 3D cells using the focus estimator value from multi-focal fluorescence images of cells. Initially, 3D cultured cells are captured with an optical microscope by changing the focus. Then the approximate position of the cells is assigned as ROI (Region Of Interest) using the circular Hough transform in the images. The MSBF (Modified Sliding Band Filter) is applied to the obtained ROI to extract the outlines of the cell clusters, and the focus estimator values are computed based on the extracted outlines. Using the computed focus estimator values and the numerical aperture (NA) of the microscope, we extract the outline of the cell cluster considering the depth and reconstruct the cells into 3D based on the extracted outline. The reconstruction results are examined by comparing with the combined in-focus portions of the cell images.

Circular Fast Fourier Transform Application: A Useful Script for Fast Fourier Transform Data Analysis of High-resolution Transmission Electron Microscopy Image

  • Kim, Jin-Gyu;Yoo, Seung Jo;Kim, Chang-Yeon;Jou, Hyeong-Tae
    • Applied Microscopy
    • /
    • v.44 no.4
    • /
    • pp.138-143
    • /
    • 2014
  • Transmission electron microscope (TEM) is an excellent tool for studying the structure and properties of nanostructured materials. As the development of $C_s$-corrected TEM, the direct analysis of atomic structures of nanostructured materials can be performed in the high-resolution transmission electron microscopy (HRTEM). Especially, fast Fourier transform (FFT) technique in image processing is very useful way to determine the crystal structure of HRTEM images in reciprocal space. To apply FFT technique in HRTEM analysis in more reasonable and friendly manner, we made a new circular region of interest (C-ROI) FFT script and tested it for several HRTEM analysis. Consequentially, it was proved that the new FFT application shows more quantitative and clearer results than conventional FFT script by removing the streaky artifacts in FFT pattern images. Finally, it is expected that the new FFT script gives great advantages for quantitative interpretation of HRTEM images of many nanostructured materials.

Design and Comparison of Superconducting Magnets with Circular Coil Elements for Magnetic Resonance Imaging (원형무코일로 구성된 MRI용 초전도 자석의 설계와 비교)

  • Kim, Yong-Gwon;Hyun, Jung-Ho;Seo, Jeung-Hoon;Kim, Hyug-Gi;Oh, Chang-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.6
    • /
    • pp.57-62
    • /
    • 2011
  • This paper proposed a method which is the three types of magnet model for improving field inhomogeneity of superconducting magnet. The length of coil wire was compared for the optimized current pattern using minimum power methods and field inhomogeneity under the specific simulation condition in case of same magnet field strength about each magnet type field inhomogeneity. Length of wire and field inhomogeneity were compared under the same condition(18 target points, 20cm DSV). According to the simulation results, the smaller target points can reduce the wire length but it can not improve the field inhomogeneity. Length of wire and low field inhomogeneity can not improve in same time. However, small DSV and reducing target points can overcome the these problem. And to conclude, if it processes shimming as reducing target points in case of magnet model which is open to space, about the size of same imaging region it needs a lot of current values(or the length of wire) and decreases field homogeneity but it is useful to get small ROI.

An Analysis of the Management of a Tertiary General Hospital (2011 to 2013)

  • Park, Hyun-Suk
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.1
    • /
    • pp.276-289
    • /
    • 2015
  • Purpose. To efficiently manage hospitals, this study aims to analyze the general characteristics, common-type balance sheet, common-type profit and loss statement and financial ratio of a tertiary general hospital and use the results as basic data for future hospital development by comprehending causes for problems and analyzing hospital management. Methods. By using information about a tertiary general hospital, located in A Metropolitan City, provided through Alio (www.alio.go.kr), a public organization information provider, Health Insurance Review & Assessment Service, and Ministry of Health and Welfare, this study used data during 3 years(2011 to 2013) by analyzing the general characteristics, common-type balance sheet, common-type profit and loss statement, industrial mean ratio and financial ratio of hospitals. Results. This study came to the following conclusions through the general characteristics, common-type balance sheet, common-type profit and loss statement, industrial mean ratio, financial ratio, circular chart and ROI by analyzing the data from 2011 to 2013. Conclusions. Overall, A Tertiary General Hospital showed an increase in fixed cost due to the construction of J Hospital and even in the size of capital and assets. It also showed an increase in medical profit, but the increase of its medical cost was higher, resulting in a financial loss. Especially, this hospital showed a slight decrease in net profit, featuring a reduction in inventory turnover. When the management of A Tertiary General Hospital was predicted based on such features, this hospital is expected to improve its profit structure through the opening of J Hospital, and it is necessary for this hospital to increase and sustain the turnover rate of inventories accumulated by managing them better.

The Lowest Dose for CT Attenuation Correction in PET/CT

  • Kang, Byung-Sam;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.111-115
    • /
    • 2011
  • PET/CT(Positron Emission Tomography/Computed Tomography) is an examination combining morphological and functional information in one examination. The purpose of this study is to see the lowest CT dose for attenuation correction in the PET/CT maintaining good image quality when considering CT scan dose to the patients. We injected $^{18}F$-FDG and water into the cylinder shaped phantom, and obtained emission images for 3 mins and transmission images(140 kVp, 8 sec, 10~200 mA for transmission images), and reconstructed the images to PET/CT images with Iterative method. Data(Maximum, Minimum, Average, Standard Deviation) were obtained by drawing a circular ROI(Region Of Interest) on each sphere in each image set with Image J program. And then described SD according to the CT and PEC/CT images as graphes. Through the graphes, we got the relationships of mA and quality of images. SDs according to CT graph were 16.25 at 10 mA, 7.26 at 50 mA, 5.5 at 100 mA, 4.29 at 150 mA, and 3.83 at 200 mA, i.e. the higer mA, the better image quality was presented. SDs according to PET/CT graph were 1823.2 at 10 mA, 1825.1 at 50 mA, 1828.4 at 100 mA, 1813.8 at 150 mA, and 1811.3 at 200 mA. Calculated SDs at PET/CT images were maintained. This means images quality is maintained having nothing to do with mA of high and low.

  • PDF

Strain elastography of tongue carcinoma using intraoral ultrasonography: A preliminary study to characterize normal tissues and lesions

  • Ogura, Ichiro;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.45-49
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the quantitative strain elastography of tongue carcinoma using intraoral ultrasonography. Materials and Methods: Two patients with squamous cell carcinoma (SCC) who underwent quantitative strain elastography for the diagnosis of tongue lesions using intraoral ultrasonography were included in this prospective study. Strain elastography was performed using a linear 14 MHz transducer (Aplio 300; Canon Medical Systems, Otawara, Japan). Manual light compression and decompression of the tongue by the transducer was performed to achieve optimal and consistent color coding. The variation in tissue strain over time caused by the compression exerted using the probe was displayed as a strain graph. The integrated strain elastography software allowed the operator to place circular regions of interest (ROIs) of various diameters within the elastography window, and automatically displayed quantitative strain (%) for each ROI. Quantitative indices of the strain (%) were measured for normal tissues and lesions in the tongue. Results: The average strain of normal tissue and tongue SCC in a 50-year-old man was 1.468% and 0.000%, respectively. The average strain of normal tissue and tongue SCC in a 59-year-old man was 1.007% and 0.000%, respectively. Conclusion: We investigated the quantitative strain elastography of tongue carcinoma using intraoral ultrasonography. Strain elastography using intraoral ultrasonography is a promising technique for characterizing and differentiating normal tissues and SCC in the tongue.

Analysis of the Effect of Entry-Level 3D Printer Materials on CT Images (보급형 3D프린터 재료가 CT 영상에 미치는 영향 분석)

  • Se-Hwan, Park;Hyun-Jung, Jo;Sung-Jun, Lee;Song-Bin, Lee;Sang-Hyub, Park;Dae-Yeon, Ryu;Yeong-Cheol, Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.673-680
    • /
    • 2022
  • In this study, based on PLA, we analyzed the Hounsfield Unit (HU) of materials containing 20% each of aluminum, wood, copper, carbon, and marble, and tried to analyze how they affect the image. A cylindrical phantom of 5×30×30 ㎣ (thickness×diameter×height) was fabricated using a entry-level 3D printer. The kV was changed to 80, 100 and 120, and the mAs was changed to 100 and 200 mAs, and the phantom in the center of the table was cross-scanned under a total of six conditions. A circular ROI was set using image J program and the quantification value of the material part HU and the quantification value of the peripheral part CNR were obtained. The HU average of the material part increased in the order of [PLA - wood 20%], [PLA - marble 20%], [PLA - carbon 20%], [PLA 100%], [PLA - aluminum 20%], [PLA - copper 20%] (p<0.05) a negative correlation was confirmed with the HU by increasing kV. It was confirmed that the CNR value in the peripheral area increased in the order of [PLA - marble 20%], [PLA - copper 20%], [PLA - carbon 20%], [PLA - wood 20%], [PLA - aluminum 20%], and [PLA - 100%] (p<0.05). Human organs with similar HU values for each material are [PLA - copper 20%] compact bone, [PLA - aluminum 20%] cancellous bone, [PLA 100%] coagulated blood, [PLA - carbon 20%] and [PLA - marble 20%] liver, muscle, spleen and [PLA - wood 20%] had similar values to fat. In addition, we confirmed the blur phenomenon that blurs the image around the filament with all materials, and confirmed that [PLA 100%] especially has the most blur around the filament. Therefore, it is considered desirable to reflect the HU value of the target organ and consider cloudiness around the phantom when selecting materials for medical phantom fabrication, and this research can provide basic data.