• 제목/요약/키워드: Circuit break

검색결과 77건 처리시간 0.027초

Integrated Thyristor Switch Structures for Capacitor Discharge Application

  • 김은동;장창리;김상철;백도현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 반도체재료
    • /
    • pp.22-25
    • /
    • 2001
  • A thyristor switch circuit for capacitor discharge application, of which the equivalent circuit includes a resistor between cathode and gate of a reverse-conducting thyristor and an avalanche diode anti-parallel between its anode and gate to set thyristor tum-on voltage, is monolithically integrated by planar process with AVE double-implantation method. To ensure a lower breakdown voltage of the avalanche diode for thyristor tum-on than the break-over voltage of the thyristor, $p^+$ wells on thyristor p base layer are made by boron implantation/drive-in for a steeper doping profile with higher concentrations while rest p layers of thyristor and free-wheeling diode parts are formed with Al implantation/drive-in for a doping profile of lower steepness. The free-wheeling diode part is isolated from the thyristor part by formation of separated p-well emitter for suppressing commutation between them, which is achieved during the formation of thyristor p-base layer.

  • PDF

광전소자를 이용한 전류안정부저항 특성회로의 구성 (A Study on Composition of Current Stable Negative Resistance Circuitwith LED and CdS.)

  • 박의열;도시홍;문재덕
    • 대한전자공학회논문지
    • /
    • 제12권5호
    • /
    • pp.1-5
    • /
    • 1975
  • 접합형 트린지스터와 발광다이오드(LED) 및 광도전소자(CdS)로서 구성된 광결합 전류안정부저항회로를 진안하였다. 이는 일반적으로 광트랜지스터보다도 더 예민한 것을 이용하여, CdS와 LED를 밀착 시켜서 LED에 흐르는 전류와 CdS의 실효저항변화로써 결합된 광결합방식을 택하였다. 트랜지스터의 콜랙터-에미터간에 인위적인 누변저항을 삽입하는 방법을 도입함으로써 부저항치 및 최대입력단자전압치를 임의로 변화할 수 있게 하였으며, 제안한 회로를 분석하고 또 이를 실험적으로 확인하였다. 누변저항을 1KΩ에서 30KΩ까지 변화시켰을 때 최대입력단자전압은 1.65V에서 4.22V로 변하였고, 부저항치는 -1.0KΩ에서 -10.0KΩ까지 변하였다. 또 실험치에 대한 계산치에의 상대백분최대오차가 11%이었다. A current stable negative resistance circuit has been constucted with combination of coulplementary symmetrical transistors, a light emitting diode and a photoconductive cell. The negative resistance(Rn) and break-over voltage(VBo) can be set at a designed value according to adjustment of the artificial leakage resistance of p-n-p transistor. The RN and VBo calculated in this designed circuit are checked though the experiments, the errors are found less than 11%.

  • PDF

전력선 모뎀을 이용한 최대 수요전력 관리 시스템 (Demand Controller Management System using Power Line Modem)

  • 김수곤;임병국;이원선;전희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1067-1070
    • /
    • 2002
  • The maximum demand power management system(the demand controller) is an equipment for demand management. If the pre-estimated load is over the preset power, the demand controller make warnings and break the load circuit according to predefined priority. Then consumption power is maintained below the maximum demand power level. The DTU receives the control commands from demand controller, and then controls loads. In this paper, the power line cables are used for communication between the demand controller and DTUs and monitoring PC. The experiments show that the proposed system is compatible with the conventional system, and feasible for new or remodeling plant.

  • PDF

퍼지논리를 적용한 전기적 접촉불량 및 아크 검출에 관한 연구 (A study on the detection of poor contact and arcing fault using a fuzzy logic)

  • 김현우;김인태
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2007년도 추계학술논문발표회 논문집
    • /
    • pp.205-210
    • /
    • 2007
  • This study on the prevention of electric fire. Generally the electric fire is caused by break or disconnection of the power line, short circuit and poor contact, arcing fault ect. In these causes, this paper is studied on the detection of poor contact and arcing fault. The arcing fault is caused by poor contact mainly. The arcing fault can occurs a electric fire by interaction of flammable gas and materials and it can be caused of tracking and carbonization. These phenomenons is also caused of electric fire. Therefore this paper is studied on the detection of arcing fault and poor contact.

  • PDF

154kV 주변압기용 가스차단기(GCB) 소손에 따른 원인규명과 항구대책 분석 (A Study on the cause and permanent measures on trouble of the GCB for the Main Tr. of Voltage, 154kV)

  • 전규남;장문성;옥광석;남궁혁;안주훈;정재원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.285-286
    • /
    • 2008
  • The Gas Circuit Breaker for the Main Transformer of voltage, 154kV at the ist Hapcheon hydraulic power station, break down by the falling of a thunderbolt from now, let's improve the efficiency on the maintenance of generating equipment by studying about the cause and the method for this problem.

  • PDF

전차선 섹션 보호장치에 관한 연구 (Apparatus for section of electric automobile)

  • 박지수;신동남;안승갑;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.829-835
    • /
    • 2007
  • For constant operation, Electric Railway System has many electrically divided parts of the trolley lines to avoid error spreading. FRP-Section have a role to divide Catenary trolley lines electrically. If one electric train approach to the section at the same time with partial power failure, the pantograph of train can make a short circuit with supplied part to failure part. Electric arc induced with this switching effect, can break FRP-section, and there are such error cases. In this study, we propose one method to prevent FRP-section breakdown from these reason, with detecting sensor at the sectional position.

  • PDF

고온초전도벌크형 전동기의 특성시험 (Performance Evaluation of the HTS Bulk type Motor)

  • 심정욱;임형우;차귀수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.44-48
    • /
    • 2000
  • The high temperature superconducting bulk can be used as the rotor of an ac motor. This paper presents the fabrication and test results of a ac motor with HTS bulk rotor. The rotor of a conventional squirrel cage induction motor was replaced with cylinder type YBCO bulk. Height and outer diameter of the HTS bulk was 15mm and 46mm, respectively. Eddy current brake using aluminium disk was used to measure the torque of the HTS motor. No load test, locked rotor test and load test were performed to examine the characteristics of the HTS motor. Test results show the motor can rotate at synchronous speed without any special starting circuit. Maximum output power of the constructed HTS motor was 408W.

  • PDF

TN-C-S계통에서 PEN도체의 단선고장의 위험성 및 보호대책 (Hazards and Solutions of Loss of the PEN Conductor in TN-C-S System)

  • 이복희;이규선;안창환;김한수
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.113-120
    • /
    • 2007
  • 본 논문은 TN-C-S계통에서 중성선 겸용 보호도체(PEN도체)의 단선고장시 감전의 위험성 및 보호대책에 관한 것으로 PEN도체의 단선고장시 노출도전성 부분의 접촉전압을 줄이기 위하여 전원측 접지저항과 수용가 추가접지 저항에 따른 PEN도체 단선시 노출도전성 부분에 나타나는 접촉전압을 실험적으로 조사하였다. 그 결과 TN-C-S 계통으로 공급되는 설비에 대하여 등전위본딩은 중요한 요건이다. 수용가의 인입구에 추가접지를 하는 것은 PEN 도체의 단선시 노출도전성 부분에 나타나는 접촉전압을 저감시키는 방법 중의 하나이다. 접촉전압을 안전전압 50[V]이하로 제한하는데 필요한 추가접지의 접지저항은 부하용량과 고장회로정수에 의하여 정해진다. 또한 부족전압계전기는 TN-C-S계통에서 PEN도체의 단선고장을 검출할 수 있는 적절한 해결방안이 될 수 있다.

IoT Enabled Smart Emergency LED Exit Sign controller Design using Arduino

  • Jung, Joonseok;Kwon, Jongman;Mfitumukiza, Joseph;Jung, Soonho;Lee, Minwoo;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • 제6권1호
    • /
    • pp.76-81
    • /
    • 2017
  • This paper presents a low cost and flexible IoT enabled smart LED controller using Arduino that is used for emergency exit signs. The Internet of Things (IoT) is become a global network that put together physical objects using network communications for the purpose of inter-communication of devices, access information on internet, interaction with users as well as permanent connected environment. A crucial point in this paper, is underlined on the potential key points of applying the Arduino platform as low cost, easy to use microcontroller with combination of various sensors applied in IoT technology to facilitate and establishment of intelligent products. To demonstrate the feasibility and effectiveness of the system, devices such as LED strip, combination of various sensors, Arduino, power plug and ZigBee module have been integrated to setup smart emergency exit sign system. The general concept of the proposed system design discussed in this paper is all about the combination of various sensor such as smoke detector sensor, humidity, temperature sensor, glass break sensors as well as camera sensor that are connected to the main controller (Arduino) for the purpose of communicating with LED exit signs displayer and dedicated PC monitors from integrated system monitoring (controller room) through gateway devices using Zig bee module. A critical appraisal of the approach in the area concludes the paper.

A Novel Separator Membrane for Safer Lithium-ion Rechargeable Batteries

  • Lee, Sang-Young;Kim, Seok-Koo;Hong, Jang-Hyuck;Shin, Byeong-Jin;Park, Jong-Hyuck;Sohn, Joon-Yong;Jang, Hyun-Min;Ahn, Soon-Ho
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.69-70
    • /
    • 2006
  • In lithium-ion batteries, separator membrane's, main role is to physically isolate a cathode and an anode while maintaining rapid transport of ionic charge carriers during the passage of electric current. As far as battery safety is concerned, the electrical isolation of electrodes is most crucial since unexpected short-circuits across the membrane induces hot spots where thermal runaway may break out. Internal short-circuits are generally believed to occur by protrusions on the electrode surface either by unavoidable deposits of metallic impurities or by dendritic lithium growth during battery operation. Another cause is shrinkage of the separator membrane when exposed to heat. If separator membrane can be engineered to prevent the internal short-circuit, it will not be difficult to improve lithium-ion batteries' safety. Commonly the separators employed in lithium-ion batteries are made of polyethylene (PE) and/or polypropylene (PP). These materials have terrible limitations in preventing the fore-mentioned internal short-circuit between electrodes due to their poor dimensional stability and mechanical strength. In this study we have developed a novel separator membrane that possesses very high thermal and mechanical stability. The cells employing this separator provided noticeable safety improvement in the various abuse tests.

  • PDF