• 제목/요약/키워드: Circuit analysis ability

검색결과 38건 처리시간 0.024초

M.Tr 87Ry 2nd CT 회로 오결선 등 개선사례 분석 (Study on the reform case about a bad connection of M.Tr 87Ry 2nd CT circuit etc.)

  • 박강서;박준성;최종수
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.374-378
    • /
    • 2008
  • 사업용전기설비에 대한 사용전검사 수행 중 전기설비기술기준 및 판단기준에 부합되지 않거나 공사계획신고의 기술시방서 및 설계도서 등의 내용과 일치 않는 부분에 대한 시정 조치한 개선사례를 분석하고 이를 전파하여 전기재해 예방에 도움을 주고자 하며, 향후에도 중요 개선사례들을 지속적으로 발굴하여 현장 전력기술 능력 향상을 위하여 노력해 나아가고자 한다.

  • PDF

로드셀을 이용한 요류검사기의 구현 및 평가 (Estimation and Implementation of the Uroflowmetry Using Load Cell)

  • 정도운;조성택;남기곤;정문기;전계록
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.436-445
    • /
    • 2004
  • In this study, a uroflowmetry system was developed to detect a voiding symptom conveniently at home or hospital. A implemented hardware was composed of mechanism and system circuit part, the software was developed to process uroflow data, graph display, extraction of parameter, and evaluation of congregate rate so as to analysis obtaining uroflow data. The following experiment was performed to evaluate an ability of classification and fitness. The curve pattern of uroflow was classified into each symptom. Various parameters were calculated in the curve pattern of each uroflow as follows. The parameters are MFR, AFR, VOL, VT, and FT. A significant difference among parameters was examined by a statistical analysis for extracted parameters between normal and abnormal experimental group. The uroflow data with the various symptom was divided into normal and abnormal group using fuzzy classifier. The result of the fuzzy classification using MFR and AFR was superior by 91.23 % than grouping evaluation including VOL.

전기적 불완전 접촉에 따른 동산화물의 발열 및 아크 특성 (The Heating of Cu-oxide and Arc Properties according to Electrical Poor Contact)

  • 김완수;박상준;황동현
    • 한국안전학회지
    • /
    • 제34권3호
    • /
    • pp.15-20
    • /
    • 2019
  • As industry is progressing and standards of living are improved, the demand of electrical energy is expected to grow 8-9% annually. Therefore, the importance of electrical fire prevention technology with the ability of the power supply is being emphasized. According to the statistics of fire in Korea, fire occurred about 45,000 cases annually, and electrical fire possessed about 20%. The electrical fire by poor contact has increased gradually, can be connected as great fire to secondarily induce short circuit and earth fault. Then analysis of heating causes of electrical connections between copper and copper alloy is needed. Also, detection and analysis algorithm of oxide at copper alloy are necessary. In this research, in order to understand the characteristics of oxide growth with rising resistance and heating, it is demonstrated that the oxide at electrical connections can cause fire due to arcing.

Modeling and Control Method for High-power Electromagnetic Transmitter Power Supplies

  • Yu, Fei;Zhang, Yi-Ming
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.679-691
    • /
    • 2013
  • High-power electromagnetic transmitter power supplies are an important part of deep geophysical exploration equipment. This is especially true in complex environments, where the ability to produce a highly accurate and stable output and safety through redundancy have become the key issues in the design of high-power electromagnetic transmitter power supplies. To solve these issues, a high-frequency switching power cascade based emission power supply is designed. By combining the circuit averaged model and the equivalent controlled source method, a modular mathematical model is established with the on-state loss and transformer induction loss being taken into account. A triple-loop control including an inner current loop, an outer voltage loop and a load current forward feedback, and a digitalized voltage/current sharing control method are proposed for the realization of the rapid, stable and highly accurate output of the system. By using a new algorithm referred to as GAPSO, which integrates a genetic algorithm and a particle swarm algorithm, the parameters of the controller are tuned. A multi-module cascade helps to achieve system redundancy. A simulation analysis of the open-loop system proves the accuracy of the established system and provides a better reflection of the characteristics of the power supply. A parameter tuning simulation proves the effectiveness of the GAPSO algorithm. A closed-loop simulation of the system and field geological exploration experiments demonstrate the effectiveness of the control method. This ensures both the system's excellent stability and the output's accuracy. It also ensures the accuracy of the established mathematical model as well as its ability to meet the requirements of practical field deep exploration.

매트랩을 사용한 윈도우 구동형 EMTP 패키지의 개발 (The Development of Window Operating EMTP Package Using Matlab)

  • 이재용
    • 전자공학회논문지T
    • /
    • 제36T권3호
    • /
    • pp.79-84
    • /
    • 1999
  • 기존의 포트란-77로 작성된 EMTP(전자기 과도현상 해석 프로그램)는 폐쇄적인 구조로 되어 있을 뿐 아니라, 낮은 수준의 데이터 관리에서부터 실제적인 수치적 풀이에 이르기까지 그 기능을 만족하기 위하여 많은 양의 코드수를 사용하기 때문에, 수치적인 풀이의 프로그램화는 희석되어지고, 시각화는 거의 불가능하다. 그래서, 프로그램 모듈의 관리나 개발에 있어서 많은 어려움이 있다. 본 논문에서는 매트랩과 비주얼 C++을 사용하여 EMTP의 재개발을 위해 적합한 새로운 디자인 아이디어를 제안하고, 윈도우 환경에서 구동하는 새로운 EMTP 패키지의 개발을 제시한다. 이 패키지는 전기회로에서 과도현상의 해석을 위한 매트랩 계산 엔진과 그래픽 사용자 인터페이스 기능을 가진다.

  • PDF

ABS 모듈의 접속부 및 전원배선 손상으로 인한 차량화재 사고사례 분석 (Analysis on the Fire Accident of Vehicle Due to Damage of Connector and wiring on an Anti-lock Brake System(ABS) Module)

  • 박남규;김진표;남정우;박종택;송재용
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.13-19
    • /
    • 2017
  • In this paper, study of vehicle fire cases caused by connector and power wiring of anti-lock brake system(ABS) module damage is presented. The purpose of ABS module is to improve braking and steering ability under sudden stop of the vehicle by repeatedly activating and releasing the brake with electric signal via electric control unit. The electric control unit for ABS may experience incomplete contact between power line and signal line or electrical breakdown on the printed circuit board by undergoing repetitive signal change which would consequently result in electrical heat and spark, eventually leading to automotive fire. Therefore, the purpose of this paper is to provide fundamental data by analyzing connector and power wiring of ABS module damage conducive to the precise investigation on the cause of vehicle fire.

저가형 요분석 시스템의 다중 광 검출 모듈개발 (Development of multi-colorimeter module for low-cost urinalysis strip readers)

  • 예수영;전용욱;정도운;전계록;노정훈
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.387-395
    • /
    • 2008
  • An optic module system is developed adopting multiple colorimetry units for the measurement of multi-pad urinalysis dipsticks. Multiple photometry system instead of moving mechanisms has the advantages of system reliability and simplicity as well as economic aspects due to the recent development of economic color light emitting diodes and stable photo sensors. An integration amplifier with programmable integration time, a current source circuit with selectable and stable current settings were connected through analog multiplexers to thirty light emitting diodes for illumination and ten photo transistors for reading each strip pad. All the circuits are controlled by a microprocessor through a simple set of serial communication commands. The detect ability is eighteen times better than the minimum color difference of the test grading which is 0.013 in urobilinogen in the color space defined in this paper.

전철 지중배전선로의 충전전류보상에 관한 연구 (A Study of the Charging Current Effect on Underground Distribution Line in Electric Railway)

  • 김양수;장우진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.214-218
    • /
    • 2008
  • Because on the high-tension underground distribution line of an electric railway high voltage XLPE Cable two or three circuits between railway stations with a standard as receiving transformer facilities are established at a $30km{\sim}50km$ interval, reactive power in which the phase of a current is larger than that of a voltage is supplied when trains are not working, so when there are no loading or low loading as night. Due to the long-distance trend of the underground distribution system on an alternating current railway distribution line, the terminal voltage of a transformer is over the standard voltage, and after all, commercial cycle overvoltage is continued. To solve this problem, the shunt reactor is installed in middle of power distribution lines to maintain receiver voltage meted under the allowance regulation through control of the reactive power. Also, in case that the thickness of single cable is over $60mm^2$ and length of line is about over 30km, a circuit breaker is broken by shorting shunt ability of charging current in excess of shunt current(31.5A.rms). Therefore, this thesis presents installing the location of shunt reactor for quantitative analysis by using optimum algorism for compensation and control of the charging current.

  • PDF

The Impact of Food Delivery Apps on Urban Hotels after the Pandemic and its Implications

  • Eungoo KANG
    • 산경연구논집
    • /
    • 제15권4호
    • /
    • pp.11-18
    • /
    • 2024
  • Purpose: The primary purpose of this research is to investigate the multidisciplinary effect of food delivery apps (FDAs) in urban hotels in the wake of the lockdown due to Covid-19 pandemic. Specifically, the study aims: To explore and scrutinize the primary shifts in customer behavior and preferences in modern urban hotels, and to explore and scrutinize the primary shifts in customer behavior and preferences in modern urban hotels. Research design, data and methodology: This study conducted a systematic literature review to gather evidence of the FDA's effect on customer behavior and the hospitality industry during the Covid-19 pandemic. Complying with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) principles guarantees a structured and transparent method to search the literature and its analysis. Results: The result based on the systematic review has indicated that the booming business of food delivery at home companies and changing consumer tastes prove the FDA's growing circuit in the hotel industry, thus demonstrating their ability and power to adapt to changing trends. Conclusions: Therefore, this study concludes that using FDA's platform, future hospitality managers have to focus on agility in operations, innovation, and technology integration to keep up with changing consumer trends and market conditions.

ChatGPT을 활용한 디지털회로 설계 능력에 대한 비교 분석 (Comparative analysis of the digital circuit designing ability of ChatGPT)

  • 남기훈
    • 문화기술의 융합
    • /
    • 제9권6호
    • /
    • pp.967-971
    • /
    • 2023
  • 최근에는 다양한 플랫폼 서비스가 인공지능을 활용하여 제공되고 있으며, 그 중 하나로 ChatGPT는 대량의 데이터를 자연어 처리하여 자가 학습 후 답변을 생성하는 역할을 수행하고 있다. ChatGPT는 IT 분야에서 소프트웨어 프로그래밍 분야를 포함하여 다양한 작업을 수행할 수 있는데, 특히 프로그램을 대표하는 C언어를 통해 간단한 프로그램을 생성하고 에러를 수정하는데 도움을 줄 수 있다. 이러한 능력을 토대로 C언어를 기반으로 만들어진 하드웨어 언어인 베릴로그 HDL도 ChatGPT에서 원활한 생성이 예상되지만, 베릴로그 HDL의 합성은 명령문들을 논리회로 구조 형태로 생성하는 것이기에 결과물들의 정상적인 실행 여부를 확인해야 한다. 본 논문에서는 용이한 실험을 위해 규모가 적은 논리회로들을 선택하여 ChatGPT에서 생성된 디지털회로와 인간이 만든 회로들의 결과를 확인하려 한다. 실험 환경은 Xilinx ISE 14.7로 모듈들을 모델링하였으며 xc3s1000 FPGA칩을 사용하여 구현하였다. 구현된 결과물을 FPGA의 사용 면적과 처리 시간을 각각 비교 분석함으로써 ChatGPT의 생성물과 베릴로그 HDL의 생성물의 성능을 비교하였다.