• Title/Summary/Keyword: Cine

Search Result 93, Processing Time 0.032 seconds

Cardiac MRI (심장 자기공명영상)

  • Lee, Jong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • The obstacles for cardiac imaging are motion artifacts due to cardiac motion, respiration, and blood flow, and low signal due to small tissue volume of heart. To overcome these obstacles, fast imaging technique with ECG gating is utilized. Cardiac exam using MRI comprises of morphology, ventricular function, myocardial perfusion, metabolism, and coronary artery morphology. During cardiac morphology evaluation, double and triple inversion recovery techniques are used to depict myocardial fluidity and soft tissue structure such as fat tissue, respectively. By checking the first-pass enhancement of myocardium using contrast-enhanced fast gradient echo technique, myocardial blood flow can be evaluated. In addition, delayed imaging in 10 - 15 minutes can inform myocardial destruction such as chronic myocardial infarction. Ventricular function including regional and global wall motion can be checked by fast gradient echo cine imaging in quantitative way. MRI is acknowledged to be practical for integrated cardiac evaluation technique except coronary angiography. Especially delay imaging is the greatest merit of MRI in myocardial viability evaluation.

  • PDF

Using 'RED ONE' Camera for Digital Film Making (디지털 영화제작을 위한 레드 원 카메라의 활용성 연구)

  • Ko, Hyun-Wook;Min, Kyung-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.9
    • /
    • pp.163-170
    • /
    • 2009
  • This paper is an analysis of the newly invented RED ONE camera and its various advantages, and also a comparison of the results with already existing digital cameras. As film production systems have been converting to digital systems, Arri Camera, one of the existing film camera companies, has invented and developed the Arri D21.Sony, the leader of the high definition digital camera industry, is also securing its role as the leader of digital filmmaking by introducing the CineAlta F-900 series. With these advances in digital filmmaking, the advent of the RED ONE camera opens doors to new possibilities to digital filmmakers. The development of digital cameras with thoughtful consideration for its users has Influenced the filmmaking environment immensely and has become the reason why it is playing a major role in digital filmmaking.

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.

Optimum Region-of-Interest Acquisition for Intelligent Surveillance System using Multiple Active Cameras

  • Kim, Young-Ouk;Park, Chang-Woo;Sung, Ha-Gyeong;Park, Chang-Han;Namkung, Jae-Chan
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.628-631
    • /
    • 2003
  • In this paper, we present real-time, accurate face region detection and tracking technique for an intelligent surveillance system. It is very important to obtain the high-resolution images, which enables accurate identification of an object-of-interest. Conventional surveillance or security systems, however, usually provide poor image quality because they use one or more fixed cameras and keep recording scenes without any cine. We implemented a real-time surveillance system that tracks a moving person using four pan-tilt-zoom (PTZ) cameras. While tracking, the region-of-interest (ROI) can be obtained by using a low-pass filter and background subtraction. Color information in the ROI is updated to extract features for optimal tracking and zooming. The experiment with real human faces showed highly acceptable results in the sense of both accuracy and computational efficiency.

  • PDF

Development of an EEG and EP Mapping System based on the Graphical User Interface and Machine Automation (Graphical User Interface 및 자동화에 기초를 둔 뇌파 및 뇌 유발 전위 진단 시스템)

  • Kim, I.Y.;Lee, T.Y.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.81-84
    • /
    • 1994
  • A clinically oriented EEG and EP mapping system was developed with user-friendly interface and easy interactive operations. The system was based on the graphical user interface developed with C/C++ and Software Development Kit (SDK) operated under Microsoft Windows 3.1. Continuous acquisition for the EEG signal and burst mode acquisition for EEG signal syncronized to the external stimuli arc implemented with real time display. A neural network based automatic artifact discrimation is developed and implemented with which examination time can be reduced by a factor of 3 or more. Several bands of spectral maps and spectrums arc displayed for EEG diagnosis. Amplitude maps of EP signal at specified times by operator are displayed together with cine mode of EP maps for dynamic study. Source localization and other statistical signal processing are also included.

  • PDF

Valve Thromboses after Mechanical Valve Replacements -3 Caseds- (기계판막 치환후 발생한 혈전증 3례 보고)

  • 문준호
    • Journal of Chest Surgery
    • /
    • v.27 no.12
    • /
    • pp.1031-1035
    • /
    • 1994
  • Mechanical valve thrombosis is a serious and potential lethal complication unless early diagnosis & prompt therapy are made. We have been experienced 3 cases of valve thrombosis. From Aug. 1988 to July 1994, reoperations of mitral valve replacement [MVR] with mechanical prostheses [all mitral] were performed in three patients[2 men, 1 woman] due to valve thromboses. All three patients were diagnosed by means of cineradiography. Preoperative status of was shock status and he was applied intra-aortic balloon pump [IABP]. All three cases of prosthetic valve failure [PVF] were treated by Redo-MVR. Time intervals of reoperations were 5months, 40months, and 35months, respectively. In all cases, valve thromboses were excised successfully. Cineradiography provided an accurate diagnosis in all cases, which was utilized as safe, reliable & noninvasive imaging modalities. There were no operative death & complication. All three patients were fully recovered and returned to their employements, and active lives.

  • PDF

Acid and Base Catalyzed Intramolecular Cyclizations of N-Benzoylthiocarbamoyl-acetals

  • Lee, Bong-Yong;Kim, Choong-Sup;Lee, Jong-Wook
    • Archives of Pharmacal Research
    • /
    • v.23 no.2
    • /
    • pp.99-103
    • /
    • 2000
  • Acid and base catalyzed intramolecular cyclizations of N-benzoylthioureidoacetal, contain-ing four functional groups adjacent to thiourea such as benzocarbamoyl, acetal, thioure and amide, were investigated. The condensation reaction of N-benzoyl thiocarbamoylgly-cine amide in the presence of 10% aqueous NaOH provided 1-(2,2-dimethoxy)ethyl-imi- dazolidine-2-thione exclusively. In the presence of pyridine, it was transformed to 2- thiohydantoin. N-Benzoyl thiocarbamoyl glycine amide was completely transformed to an iminothiazolidine exclusively in the presence of Lewis acid such as borontrifluoride ether-ate or trimethylsilyl iodide. 1-(2,2-Dimethoxy)ethyl-imidazolidine-2-thione was transformed to imidazole[2,1-b]thiazole and pyrazino[5,1-a]imidazole in the presence of $BF_3$.$ET_2$O and formic acid, respectively.

  • PDF

Surgical Treatment of the Sinus Valsalva Aneurysm Rupture - 5 cases reviews - (Sinus Valsalva Rupture 에 대한 외과적 치료)

  • 이재진
    • Journal of Chest Surgery
    • /
    • v.22 no.5
    • /
    • pp.748-752
    • /
    • 1989
  • We experienced 6 patients with the sinus Valsalva aneurysm rupture during last 12 years [Jan. 1977-Sep. 1989]. Of them. 5 cases were reviewed. They consist of 3 males and 2 females, and the age ranged from 12 years to 40 years with the mean age of 25 years. 4 patients showed congestive heart failure symptoms. The diagnosis was made by 2D-Echo and cine-angiogram. In 4 patients. sinus Valsalva aneurysm ruptured from the Rt. coronary sinus to the Rt. ventricle, and in one from non-coronary sinus to the Rt. atrium. In 2 cases, resection of the aneurysm and simple stitch closure was made. Resection of the aneurysm k patch closure and AVR in one, closure of the fistula, AVR and patch closure of the associated VSD in one, and closure of the fistula, AVR k TVR in one were made in another 3 cases. There was no postoperative mortality case.

  • PDF

Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current (관상동맥 조영술(Coronary Angiography)의 씨네(cine) 촬영조건 변화에 따른 입사표면선량(ESD)과 흡수선량(DAP) 및 영상의 SNR·CNR 유용성 분석: 관전류 변화를 중점으로)

  • Seo, Young Hyun;Song, Jong Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.371-379
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the change in the X-ray condition on the entrance surface dose (ESD) and dose area product (DAP) in the cine imaging of coronary angiography (CAG), and to analyze the usefulness of the condition change on the dose relation and image quality by measuring and analyzing the Signal to Noise Radio (SNR) and Contrast to Nois Ratio (CNR) of the angiographic images taken by the Image J program. Data were collected from 33 patients (24 males and 9 females) who underwent CAG at this hospital from November 2017 to March 2018. In terms of imaging condition and data acquisition, the ESD and DAP of group A with a high tube current of 397.2 mA and group B with a low tube current of 370.7 mA were retrospectively obtained for comparison and analysis. For the SNR and CNR measurement and analysis via Image J, the result values were derived by substituting the obtained data into the formula. The correlations among ESD and DAP according to the change in the imaging condition, SNR, and CNR were analyzed by using the SPSS statistical analysis software. The relationships of groups A and B, having a difference in the imaging condition, mA, with ESD ($A:483.5{\pm}60.1$; $B: 464.4{\pm}39.9$) and DAP ($A:84.3{\pm}10.7$; $B:81.5{\pm}7$) were not statistically significant (p>0.05). In the relationships with SNR and CNR based on Image J, the SNR ($5.451{\pm}0.529$) and CNR ($0.411{\pm}0.0432$) of the images obtained via the left coronary artery (LCA) imaging of group B showed differences of $0.475{\pm}0.096$ and $-0.048{\pm}0.0$, respectively, from the SNR ($4.976{\pm}0.433$) and CNR ($0.459{\pm}0.0431$) of the LCA of group A. However, the differences were not statistically significant (p<0.05). In the SNR and CNR obtained via the right coronary artery (RCA) imaging, the SNR ($4.731{\pm}0.773$) and CNR ($0.354{\pm}0.083$) of group A showed increased values of $1.491{\pm}0.405$ and $0.188{\pm}0.005$, respectively, from the SNR ($3.24{\pm}0.368$) and CNR ($0.166{\pm}0.033$) of group B. Among these, CNR was statistically significant (p<0.05). In the correlation analysis, statistically significant results were shown in SNR (LCA) and CNR (LCA); SNR (RCA) and CNR (RCA); ESD and DAP; ESD and sec; DAP and CNR (RCA); and DAP and sec (p<0.05). As a result of the analyses on the image quality evaluation and usefulness of the dose change, the SNR and CNR were increased in the RCA images of the CAG obtained by increasing the mA. Based on the result that CNR showed a statistically significant difference, it is believed that the contrast in the image quality can be further improved by increasing the mA in RCA imaging.