• 제목/요약/키워드: Chrome

검색결과 354건 처리시간 0.025초

크롬도금 포열의 포구속도 확률분포 특성 분석 (Analysis of Probability Distribution of Muzzle Velocity for Chrome Plated Barrel)

  • 김재갑;김재훈
    • 한국군사과학기술학회지
    • /
    • 제24권4호
    • /
    • pp.401-407
    • /
    • 2021
  • To confirm the change of muzzle velocity and the most suitable probability distribution model of the 155 mm K9 howitzer barrel with chrome plating and changed rifling. Using a statistical program, the muzzle velocity were plotted on a normal distribution, a 2-parameter and 3-parameter Weibull distribution on a probability paper. Also, statistical parameters were estimated and muzzle velocity fitness test and probability of K676 charge were plotted. In both the chrome-plated with standard rifling and changed rifling for K9 barrel, the 2-parameter and 3-parameter Weibull distribution were skewed to the left compared to the normal distribution. It was confirmed that the muzzle velocity of the K9 barrel with chromium-plated is suitable for the normal distribution and 3-parameter Weibull distribution model.

Performance evaluation of plasma nitrided 316L stainless steel during long term high temperature sodium exposure

  • Akash Singh;R. Thirumurugesan;S. Krishnakumar;Revati Rani;S. Chandramouli;P. Parameswaran;R. Mythili
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1468-1475
    • /
    • 2023
  • Enhancement of wear resistance of components used in fast reactors is necessary for long service life of the components. Plasma nitriding is a promising surface modification technology to impart high hardness and improved wear resistance of various steel components. This study discusses the characterization of chrome nitrided SS316L casing ring used in secondary sodium pump of fast breeder reactor and its stability under long term sodium exposure. Microstructural and hardness analysis showed that stress relieved component could be chrome nitrided successfully to a thickness of about 100 ㎛. Assessment of in-sodium performance of the chrome nitrided casing ring subjected to long term exposure up to 5000h at 550℃, showed retention of chrome nitrided layer with a case depth almost similar to that before sodium exposure. A slight decrease in the hardness was observed due to prolonged high temperature sodium exposure. Tribological studies indicate very low coefficient of friction indicating the retention of good wear resistance of the coating even after long term sodium exposure.

피혁 폐기물로부터 collagen 추출과 크롬이온 분리에 관한 연구 (A Study on the Extraction of Collagen and Separation of Chrome Ion from Leather Waste)

  • 임봉주;임남웅;임한진
    • 유기물자원화
    • /
    • 제6권1호
    • /
    • pp.43-52
    • /
    • 1998
  • 본 연구는 피혁 폐기물로부터 크롬 이온을 분리한 상태로 Collagen을 추출할 수 있는 최적 조건에 관한 것이다. Collagen 추출에 있어 온도, pH, 그리고 알칼리 용액 농도의 영향을 실험했다. 실험결과 점도측정에 의해 초기 변성온도는 $25^{\circ}C$, 완전 변성온도는 $31.5^{\circ}C$였다. Collagen 추출의 최적조건은 가용화 온도 $15^{\circ}C{\sim}20^{\circ}C$, pH 1.5, 알칼리 용액 3%였다. PH 1.5에서 크롬 이온이 거의 분리되었다. 탄닌 폐기물로부터 크롬 이온의 분리효율은 99.5% 이상이었다. 피혁 폐기물로부터 조단백질의 추출율은 89.%이었다. 추출된 조단백질내에 hydroxyprolne과 collagen의 함량은 각각 8.53%, 63.62%였다.

  • PDF

흑색 황산3가크롬을 이용한 태양열 흡열판 선택흡수막 도금기술 (Technology of selective absorber coatings on solar collectors using black chromium+3 sulfate acid on substrates)

  • 엄태인;여운택;김동찬
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.27-35
    • /
    • 2013
  • One of the most important factors that have a large influence on performance of the solar water heater system is performance of the solar collector, more detailedly, coating technology on the surface of the solar collector, which can provide high solar absorptance and low emittance. The core of the coating technology is to coat solar selective surfaces. In this study, various performance experiments are carried out using $Cr_2(SO_4)_3{\cdot}15H_2O$ coating technology. Here, IGBT(Insulated Gate Bipolar Transistor) of 5000A-15V was used as the surface processing rectifier which can stably output power and also can control voltage and current. The plating solution mainly contains black chrome$^{+3}$ concentration, H-y Conductivity, N-u Complex, NF Additive and NC-2 Wetter. Before applying the black chrome coating on the copper plate, optimal conditions are provided by using various preprocessing methods such as removal of fat, activation, electrolytic polishing, nickel strike, copper sulfate plating and bright neckel plating, and then the automatic continuous coating experiment are performed according to plating time and cathode current density. In the experiment, after the removal of fat, chemical polishing, nickel strike and activation processes as the preprocessing methods, the black chrome coating was performed in a plate solution temperature of $28^{\circ}C$ and a cathode current density of $18A/cm^2$ for 90 seconds. The thickness of chrome and nickel on the coated plate is $0.389{\mu}m$, $159{\mu}m$ respectively. As a result of the coating experiment, it showed the most excellent performance having a high solar absorptance of 98% and a low emittance of $5{\pm}1%$ when the black chrome surface had a thickness of $0.398{\mu}m$.

내열강의 고온부식특성에 대한 크롬함량의 영향 (Hot Corrosion Properties of Heat Resistant Chrome Steels)

  • 이한상;정진성;유근봉;김의현
    • 대한금속재료학회지
    • /
    • 제48권4호
    • /
    • pp.277-288
    • /
    • 2010
  • The hot corrosion properties of heat-resistant steels were investigated in an oxidation atmosphere including artificial ash and sulfur dioxide. The heat-resistant steels of T22, T92, T122, T347HFG, Super304H and HR3C were evaluated at 620, 670 and $720^{\circ}C$ for 400 hours. The relationship between the corrosion rate and the temperature followed a bell-shaped curve with a peak rate at around $670^{\circ}C$. The corrosion rates showed a decreasing tendency as the chrome contents of these steels increased from 2.15 wt.% to 24.5 wt.%, and austenitic steels had a lower corrosion rate than ferritic steels. Sulfidation by $SO_2$ as well as molten salt corrosion also had an effect on the total corrosion rate, especially showing an increase in the corrosion rate in ferritic steels. Regardless of the chrome content in the steels and irrespective of the test temperature, the corrosion scale was composed of an outer oxide and an artificial ash mixed layer, a middle oxide layer and inner sulfide, and a mixed oxide layer. As the chrome content increased, the proportion of chrome oxide in the corrosion scale increased. Before spalling of the corrosion scale, voids and cracks were initiated in the sulfide and the mixed oxide layer or at the interface with the substrate.

염색견직물의 크롬매염에 관한 연구 (A Study on the Chrome Mordant with Dyed Silk Fabric)

  • 정인모;장병호
    • 한국잠사곤충학회지
    • /
    • 제26권2호
    • /
    • pp.26-31
    • /
    • 1984
  • In general, acid dyes been used for silk dyeing, but acid dyed silk shows weakness in color fastess, To improve this defect, the silk dyed with Acid Mordant Blue 13 was treated with chromes salts solution. Some mechanical properties and dyeing behaviors of the chrome mordant with dyed silk fabric were tested in this work. The tensile strength of silk fabric treated with chrome salts solution was decreased as the duration of treatment was increased. The mean rate constant (K) of photo-degradation was 1.019, and 1.047 after treated with Cr (III) and Cr (Ⅵ), respectively, whereas it was 1.304 in untreatment. The washing fastness of silk fabric also was improved by treatment with mordant and it was 3rd-4th grade and 4th grade when silk was treated with Cr (III) and Cr (Ⅵ), respectively, while untreatment gave 1st grade. The colour of dyed silk fabric was 2.5RP.3/10, but it was 5PB.4/3 and 5PB. 4/4 when the silk fabric was treated with Cr (III) for two hours and with Cr (Ⅵ) for one hour at 90$^{\circ}C$, respectively.

  • PDF

Black Chrome 태양광 선택흡수막의 표면분석 (Surface Analysis of Black Chrome Solar Selective Coatings)

  • 이길동;최영희;오정무
    • 태양에너지
    • /
    • 제9권2호
    • /
    • pp.69-77
    • /
    • 1989
  • The thermal degradation of electroplated black chrome coating on Ni substrates has been investigated by using Auger electron spectroscopy technique. The sample was prepared by electroplating at $20^{\circ}C$ for 20 seconds with the current density at $0.4A/cm^2$. Its surface oxidation process was investigated with 1 hour annealed sample for a temperature range of $300-550^{\circ}C$. While its optical solar absorption was dominated by fine metallic Cr particles, thermal degradation was occurred primarily by oxidation of metallic Cr particles as increasing the annealing temperature.

  • PDF

고속 경질 크롬 도금 용액 개발에 관한 연구 (A study for development of high speed hard chrome plating solution)

  • 추현식;이홍로
    • 한국표면공학회지
    • /
    • 제25권5호
    • /
    • pp.263-269
    • /
    • 1992
  • To enhancing efficiency of hard chrome plating solution more highly, cathode current efficiency were surveyed connected with hardness of deposits, surface morphology, TEM analysis and corrosion test of anode materials. Efficiency war increased up to 26% values by adding catalyst and two kind of additives. With given bath composition and 6$0^{\circ}C$, 60A/d$\m^2$ electrolosis conditionss bright and micro cracked deposits were well obtained, which showed HV 1000 values. From corrosion tests, anode materials such as Pb-Te (0.02%) and Pb-Ag(1%) showed most anti-corrosive results. Through SEM micrograph observations, ef-fects of additives on levelling, brightness and micro crack properties of hard chrome deposits could be con-firmed. Also, through TEM analysis the fact that deposits from crack free solution or high speed solution were more fine than from sargent solution could be confirmed.

  • PDF

Study on the Microstructure of Trivalent Chrome Layers b AFM and SANS

  • Choi, Y.;Lee, J.J.;Lee, B.K.;Kim, M.;Kwon, S.C.;Seung, B.S.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2003년도 춘계학술발표회 초록집
    • /
    • pp.61-61
    • /
    • 2003
  • It is important to know SIze distribution of defects In electroplated trivalent chrome layers because it significantly influences on performance of the layers. Most of the nano-scale defects are able to be introduced by hydrogen evolution during the plating. Little information is available on the nano-size defects. In this study, SANS was applied to determine the size distribution of nano-scale defects in the trivalent chrome layers prepared in a formate bath. The defect size and distribution was dependent upon plating conditions such as current density and applied voltage. SANS is one of useful techniques to determine the nano-scale defect in the electroplated layers.

  • PDF

연소기 적용 전해니켈/크롬도금 공정개발을 위한 시편시험 (Specimen Tests for a Process Development of the Electro-Nickel/Chrome Coating for a Thrust Chamber)

  • 임병직;유철성;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.113-116
    • /
    • 2011
  • 고온, 고압의 조건에서 작동하는 연소기 내벽을 보호하기 위해 적용되는 니켈/크롬코팅에 대한 적용 가능성과 성능을 평가하기 위해 3가지 코팅 조건으로 9개의 평판형 시편을 제작하였다. 제작된 시편을 이용하여 코팅 층 두께 측정, 열전도율을 측정하고 열충격시험을 수행하고 있다.

  • PDF