• Title/Summary/Keyword: Chrome(Cr)

Search Result 101, Processing Time 0.031 seconds

The Biocompatibility Of Cultured Bone Marrow Cells And Gingival Fibroblasts On The Titanium Surfaces (티타늄 배양에 대한 배양골수와 치은 섬유아세포의 생체적합성)

  • Oh, Choong-Young;Park, Joon-Bong;Kwon, Young-Hyuk;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.143-160
    • /
    • 1996
  • The purpose of this study was to evaluate the response in aspect of attachment and growth rate of osteoblasts and growth rate of osteoblasts and human gingival fibroblasts to the commercially pure titanium(CP titanium)and titanium alloy(Ti-6AI-4V) that are used widely as implant materials, and to obtain the basic information to ideal implant materials. In the studly, commercially pure titanium in first test group, titanium alloy(Ti-6AI-4V) in second test group, cobalt-chrome-molybdenum alloy(Co-Cr-Mo alloy) in positive control group, and tissue culture polystyrene plate in negative control group were used. The results of this study were as follows. 1. Bone marrow cells cultured on CP titanium and Ti-6Al-4V showed significantly greater attachment and growth rate(p(0.05) compared to Co-Cr-Mo alloy in each time. 2. There were no significant differences(p>0.05) in attachment and growth rate of bone marrow cells cultured on CP titanium and Ti-6AI-4V or tissue culture plate. 3. Most bone marrow cells cultured on CP titanium, Ti-6Al-4V and tissue culture plate were attached well to each substratum in first 2days, and then, grew at higher growth rate. On the other hand, some cells cultured on Co-Cr-Mo alloy failed to attach in first 2 days, and then, attached cells grew at lower growth rate than other groups. 4. Attachment and growth rates of gingival fibroblasts cultured on CP titanium and Ti-6Al-4V showed no significant differences(p>0.05) compared to Co-Cr-Mo alloy in 2 days, but significantly greater increase(p<0.05) in 5 and 9 days. 5. There were no significantly differences(p>0.05) between growth rates on gingival fibroblasts cultured on CP titanium, Ti-6Al-4V and tissue culture plate in 2 and 5days, but a significant lower growth rate(p<0.05) on CP titanium and Ti-6Al-4V versus tissue culture plate. 6. Some gingival fibroblasts cultured on all specimen groups failed to attach, but attached cells grew well, especially on CP titanium, Ti-GAl-4V and tissue culture plate. 7. There were no significant differences(P>0.05) between growth rates of both bone marrow cells and gingival fibroblasts cultured on CP titanium and Ti-6AI-4V. As a result of this study, both commercially pure titanium and Ti-6AI-4V showed excellent biocompatibility and there was no significant difference in the cellular response to the both metals. Bone marrow cells cultured on each substratum showed significantly greater growth rate and responded sensitively to cytotoxic effects of metal surfaces compared to gingival fibroblasts. Considering cell response to the substrate, it was likely that the composition itself of titanium metals have no significant effect on the biocompatibility. Further study need to be done to evaluate the influence of surface characteristics on cellular responses.

  • PDF

Effect of Nickel Content on Corrosion Resistance and Machinability of Fe-23Cr-2.5C-1.2Si-1.08Mn-0.48Mo-0.3V-xNi Cast Iron (Fe-23Cr-2.5C-1.2Si-1.08Mn-0.48Mo-0.3V-xNi 주철의 내식성 및 피삭성에 미치는 Ni의 영향)

  • Kim, Ki-Bin;Jung, Sung-Sik;Baek, Min-Sook;Yoon, Dong Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.576-584
    • /
    • 2020
  • The extruder screw material is mainly SKD11, but the recent development of synthetic resins have increased the occurrence of chemical corrosion and wear. To solve this issue, high chromium cast iron is needed because of its good abrasion resistance and corrosion resistance, but its use is avoided because of its poor machinability. In this study, to improve the machinability of high chrome cast iron, 0, 0.5, 1.0, 1.5% of nickel, which has excellent workability, was added to high chromium cast iron with a composition of Fe-23Cr-2.5C-1.2Si-1.08Mn-0.48Mo-0.3V, and annealed after casting. Subsequently, the effect of nickel on the machinability and corrosion resistance was analyzed using a turning test and coin polarization test, and compared with SKD11. After casting using a high-frequency vacuum induction furnace, the annealing treatment was performed at 750 ℃ for five hours and then reheated at 1100 ℃ for five hours. A turning test after annealing at 750 ℃ showed that the machinability was improved remarkably when the nickel content was over 1.0%. In the potentiodynamic polarization test in a 5% NaCl solution, the corrosion resistance decreased with increasing nickel content in the as-cast and annealing treatment. On the other hand, after reheating, the corrosion resistance was best with a 1.5% nickel content.

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

The Mechanical Properties of WC-CoFe Coating Sprayed by HVOF (고속화염용사코팅으로 제조된 WC-CoFe 코팅의 기계적 특성에 관한 연구)

  • Joo, Yun-Kon;Cho, Tong-Yul;Ha, Sung-Sik;Lee, Chan-Gyu;Chun, Hui-Gon;Hur, Sung-Gang;Yoon, Jae-Hong
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.25 no.1
    • /
    • pp.6-13
    • /
    • 2012
  • HVOF thermal spray coating of 80%WC-CoFe powder is one of the most promising candidate for the replacement of the traditional hard chrome plating and hard ceramics coating because of the environmental problem of the very toxic $Cr^{6+}$ known as carcinogen by chrome plating and the brittleness of ceramics coatings. 80%WC-CoFe powder was coated by HVOF thermal spraying for the study of durability improvement of the high speed spindle such as air bearing spindle. The coating procedure was designed by the Taguchi program, including 4 parameters of hydrogen and oxygen flow rates, powder feed rate and spray distance. The surface properties of the 80%WC-CoFe powder coating were investigated roughness, hardness and porosity. The optimal condition for thermal spray has been ensured by the relationship between the spary parameters and the hardness of the coatings. The optimal coating process obtained by Taguchi program is the process of oxygen flow rate 34 FRM, hydrogen flow rate 57 FRM, powder feed rate 35 g/min and spray distance 8 inch. The coating cross-sectional structure was observed scanning electron microscope before chemical etching. Estimation of coating porosity was performed using metallugical image analysis. The Friction and wear behaviors of HVOF WC-CoFe coating prepared by OCP are investigated by reciprocating sliding wear test at $25^{\circ}C$ and $450^{\circ}C$. Friction coefficients (FC) of coating decreases as sliding surface temperature increases from $25^{\circ}C$ to $450^{\circ}C$.

Evaluation of Heavy Metal Pollution in the Dumping Site of the Dredged Sediment, Masan Bay (마산만 오염퇴적물 준설토 투기해역의 중금속 오염평가)

  • Kwon Young-Tack
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.2
    • /
    • pp.75-81
    • /
    • 2004
  • A large amount 2.1×106 ㎥ of the polluted sediment was dredged from the Masan Bay and deposited in Gapo confined area, Masan. The dissolved metal concentrations of seawater in the dumping site (Gapo area) were observed during one tidal cycle and compared with those of seawater obtained from Jinhae Bay. The sediment was evaluated as from Non polluted to Moderately polluted by USEPA standards. It was judged that toxicological effects of sediment analyzed ranged from ERL to ERM with copper and zinc, and ERL with cadmium, chrome, lead, and nickel by the Adverse Biological Effects. The pollutant concentration was low in surface sediment compared to deeper sediment since the sediments with relatively low concentrations of pollutant were dumped to the surface. The pollutant concentration was low in surface sediment compared to deeper sediment since the sediments with relatively low concentrations of pollutant were dumped to the surface. The benthic organisms in Gapo area had higher concentrations of trace metals (Oyster: Zn 238.96, Cu 5.29 ㎍/g wet wt., Clam: Zn 17.71, Cu 1.00 ㎍/g wet wt., Mussel. Zn 187.98, Pb 0.28, Cr 0.15, Mn 4.23, Sr 1.45 and Fe 100.33 ㎍/g wet wt.) compared to outside of dumping site. However, the trace metal level in the bivalves was less than the NFPQIS (National Fisheries Products Quality Inspection Service) standard.

  • PDF

Relationship between Workers′ Exposure to Airborne Chromium and Blood and Urine Chromium Levels in Plating Process (도금업체 근로자의 공기중 크롬 노출 농도와 요 및 혈중 크롬 농도간의 상관성)

  • 이지태;신용철
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.1-10
    • /
    • 2001
  • This study was performed to evaluate chromium in air and chromium concentrations in whole blood and urine of workers at chrome plating factories, and to determine the correlation between environmental and biological chromium levels. This study involved 29 workers as study group and 24 undergraduate students as control group. The geometric means(GM) of airborne hexavalent chromium and total chromium concentrations in the plating factories were 3.4 $\mu\textrm{g}$/㎥ and 10.8 $\mu\textrm{g}$/㎥, respectively. Hexavalent chromium levels in two of total 29 measurements exceeded the korean occupational exposure limit and the American Conference of Governmental Industrial Hygienists Threshold Limit Value(ACGIH-TLV) of 50$\mu\textrm{g}$/㎥. Only one sample for total chromium exceeded the Korea occupational exposure limits, the ACGIH-TLV, and the National Institute for Occupational Safety and Health Recommended Exposure Limits(NIOSH-REL) of 500 $\mu\textrm{g}$/㎥. The GM of chromium concentrations in blood and urine of workers exposed to chromium were 8.4 $\mu\textrm{g}$/L and 11.9 $\mu\textrm{g}$/L. The GM of chromium concentrations in blood and urine of workers exposed to chromium were 8.4 $\mu\textrm{g}$/L and 11.9 $\mu\textrm{g}$/L, respectively, whereas the chromium concentrations in blood and urine of the controls were 1.6 $\mu\textrm{g}$/L and 3.8 $\mu\textrm{g}$/L, respectively. There were statistically significant differences of blood and urine concentrations between study group and control group (p<0.01). The chromium concentrations in urine were most highly related to hexavalent chromium, concentration in air(r=0.642, p<0.01). Also, there was a relatively high correlation between the hexavalent chromium concentrations in air and chromium concentrations in whole blood(r=0.557, p<0.05). These results indicate that whole-blood chromium with urinary chromium could be an indicator of chromium body burden caused by exposure to chromic acid mist in plating operation.

  • PDF

Facial Color Map of Koreans in Their Twenties - A Study for a Map of Facial Color I - (20대(代) 한국인(韓國人)의 얼굴색 지도(地圖) - 얼굴색 지도 설계를 위한 연구 I -)

  • Kim, Kyung-Soon;Park, Myung-Hee
    • Journal of the Korean Society of Costume
    • /
    • v.60 no.6
    • /
    • pp.101-116
    • /
    • 2010
  • The purpose of this thesis is in investigating the Korean twenties face color, according to the seasons, thus presenting a sample Korean Facial Color Map. The face is divided into 20 parts to take measures, and investigated through the four seasons. Minolta Chrome Meter CR-200 has been used for taking measures of the face color. Measuring subjects and area are, University students of both sex, living in the Suncheon. They are of ages the twenties. Classified measuring values of the skin colors are expressed following to the A. H. Munsell's color system. The result of this study is as followed. When comparing parts among male and female(make-up and no make-up) groups for changes with seasonal hue and value of a face color, differences have been sighted among these three groups following the seasons ; Spring(March), Summer(June), Autumn (September) and Winter(December). According to the result of Duncan's proof, the differences of the women group with the make-up attitude was shown only in value from Summer and Autumn, but no differences have been sighted between the make-up group and the no make-up group, concerning hue. Concerning hue, it was shown that men had a redder hue than women in all seasons. In Spring, both men and women had the strongest red hue, then from Summer to Autumn a strong yellowish hue appeared, to make place to a diverse coloring in Winter, followed by a reddish hue, to start all over again. Value number proved to be lower in the Summer and Autumn for the no make-up group when compared to the make-up group, showing an averaging high number for all seasons when putting on make-up; and men value number shows the lowest of the three groups.

A Study on Removal Efficiency and Applicability of Natural Type Road Non-point Pollutant Reduction Facilities (자연형 도로 비점오염저감시설의 저감효율 및 적용성 연구)

  • Lee, Sang Hyuk;Cho, Hye Jin;Kim, Lee Hyung
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.9-17
    • /
    • 2014
  • PURPOSES : The purpose of this study is to assess removal efficiency of non-point pollutants and applicability for non-point pollutant reduction facilities by conducting the demonstration project operation. METHODS : In order to analyze removal efficiency of non-point pollutants for facilities such as a grassed swale, a small constructed wetland, a free water surface wetland, a horizontal sub-surface flow wetland, and a sand filtration, the field data including specifications of facilities, rainfall, inflow and runoff rainfall effluent etc. was acquired after occurring rainfall events, and the acquired data was analyzed for removal efficiency rate to assess road non-point pollutants facilities using event mean concentration (EMC) and summation of load (SOL) methods. RESULTS : The results of analyzing rainfall effluent, non-point pollutant sources showed that total suspended solid (TSS), chemical oxygen demand (COD), biochemical oxygen demand (BOD), total nitrogen (TN), total phosphorus (TP), chrome (Cr), zinc (Zn), and lead (Pb) can be removed through non-point pollutant reduction facilities by 60.3% ~ 100%. Especially removal efficiency of TSS, COD and BOD is relatively higher than removal efficiency of other non-point pollutant sources in all kind of non-point pollutant facilities. CONCLUSIONS : Based on the result of this study, even though natural type of non-point pollutant reduction facilities for roads occupy small areas comparing with drainage basin areas, most of non-point pollutant sources would be removed through the facilities.

Chromium and nickel concentrations in air and in serum of workers in chromium and nickel electroplating plants (도금업 근로자의 혈청과 공기중 크롬 및 니켈 농도)

  • Choi, Ho Chun;Kim, Hae Jeong;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.117-127
    • /
    • 1991
  • The exposure level of chromium and nickel for chrome and nickel plating workers were evaluated. Chromium and nickel concentrations in serum from 82 exposed workers and 66 controls, who were not exposed occupationally to metals, were analyzed by flameless atomic absorption spectrophotometry. The results were as follows : 1. The recovery percent of chromium and nickel concentrations in personal air samples were 95-108.2%, 88.0-107.7%, precisions (C.V., %) were 2.7-3.1%, 2.1-4.4%. respectively. 2. The recovery percent of chromium and nickel concentrations in serum were 93.6-106.4%, 91.3-107.9% and precisions (C.V. %) were 1.1-7.6%, 2.4-5.4% respectively. 3. The exposure level of chromium and nickel concentrations in the place of preparation process were $2.0{\pm}2.00{\mu}g/m^3$, chromplating were $35.7{\pm}53.07{\mu}g/m^3$, $2.8{\pm}3.42{\mu}g/m^3$, nickelplating were $4.6.0{\pm}5.8{\mu}g/m^3$, $18.62{\pm}4.41{\mu}g/m^3$, and covering were $2.9{\pm}2.02{\mu}g/m^3$, $1.1{\pm}0.47{\mu}g/m^3$ respectively. There were significant difference of concentrations for chromium and nickel in workplaces by groups statistically. 4. Chromium concentrations in serum of exposed group and control were $0.68{\pm}0.399{\mu}g/l$, $1.41{\pm}0.748{\mu}g/l$, respectively. There were significant difference of concentrations for chromium and nickel in serum by groups statistically. 5. Chromium and nickel concentrations in serum of exposed group were not significant by workplaces.

  • PDF

Fabrication and Characteristics of X-ray Position Detection Sensor (방사선 위치 검출센서의 제작 및 특성)

  • Park, Hyung-Jun;Kim, In-Su
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.535-540
    • /
    • 2015
  • A microstrip gas chamber (MSGC), applied to digital radiography system, was designed and constructed. The microstrip electrodes were fabricated with Chrome(Cr.). by photolithography process on Silicon(Si) wafer and glass substrate. The width of anode and cathode electrodes was $10{\mu}m$, and $290{\mu}m$, respectively. The distance of the electrodes was $100{\mu}m$, and the active area was $50{\times}50mm^2$. And the number of anode was 80. The microstrip electrodes were damaged when discharges occurred over the 600 V of anode voltage. As the result of experiments. It detected the typical output signals of the pulse width, 20 ns, under the condition that the detecting gas was Ar(90%) + $CH_4$(10%), X-ray tube voltage was 42 kV, and tube current was 1 mA.