• Title/Summary/Keyword: Chrome(Cr)

Search Result 101, Processing Time 0.025 seconds

Stress analysis of the CR lens using the chrome conversion (Chrome 변환을 이용한 CR 렌즈의 미세응력 시각화)

  • Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 2005
  • The polariscope to measure the microscopic stress in CR lens consists of light source polarizer, model, polarizer, CCD, computer, chrome conversion orderly and the principal-stressed difference, (${\sigma}_1-{\sigma}_2$) and the fringe order n were measured by analyzing two components of light wave $E_1$ and $E_2$ following each polarizer's steps. The two-dimensional model could be determined from the fact that the optical axes of sample concide with the principal-stress directions. The bi-refringence acted to a light wave and the phase retardation were in proportion to the principal-stressed difference(${\sigma}_1-{\sigma}_2$) and the intensity of final light wave was proportioned to $sin2({\Delta}/2)$ and when ${\Delta}/2=n{\pi}$ (n=0, 1, 2, ${\ldots}$) the extinction occurs. Photoelastic's image by microscopic stress could analyzed using chrome conversion, and the image showed clearly.

  • PDF

A Study on the Chrome Mordant with Dyed Silk Fabric (염색견직물의 크롬매염에 관한 연구)

  • 정인모;장병호
    • Journal of Sericultural and Entomological Science
    • /
    • v.26 no.2
    • /
    • pp.26-31
    • /
    • 1984
  • In general, acid dyes been used for silk dyeing, but acid dyed silk shows weakness in color fastess, To improve this defect, the silk dyed with Acid Mordant Blue 13 was treated with chromes salts solution. Some mechanical properties and dyeing behaviors of the chrome mordant with dyed silk fabric were tested in this work. The tensile strength of silk fabric treated with chrome salts solution was decreased as the duration of treatment was increased. The mean rate constant (K) of photo-degradation was 1.019, and 1.047 after treated with Cr (III) and Cr (Ⅵ), respectively, whereas it was 1.304 in untreatment. The washing fastness of silk fabric also was improved by treatment with mordant and it was 3rd-4th grade and 4th grade when silk was treated with Cr (III) and Cr (Ⅵ), respectively, while untreatment gave 1st grade. The colour of dyed silk fabric was 2.5RP.3/10, but it was 5PB.4/3 and 5PB. 4/4 when the silk fabric was treated with Cr (III) for two hours and with Cr (Ⅵ) for one hour at 90$^{\circ}C$, respectively.

  • PDF

Dynamic Material Property of the Sinter-Forged Cu-Cr Alloys with the Variation of Chrome Content (구리-크롬 소결단조 합금의 크롬 함유량 변화에 따른 동적 물성특성)

  • Song Jung-Han;Huh Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.6 s.249
    • /
    • pp.670-677
    • /
    • 2006
  • Vacuum interrupters are used in various switch-gear components such as circuit breakers, distribution switches, contactors. The electrodes of a vacuum interrupter are manufactured of sinter-forged Cu-Cr material for good electrical and mechanical characteristics. Since the closing velocity is 1-2m/s and impact deformation of the electrode depends on the strain-rate at the given velocity, the dynamic material property of the sinter-forged Cu-Cr alloy is important to design the vacuum interrupter reliably and to identify the impact characteristics of a vacuum interrupter accurately. This paper is concerned with the dynamic material properties of sinter-forged Cu-Cr alloy for various strain rates. The amount of chrome is varied from 10 wt% to 30 wt% in order to investigate the influence of the chrome content on the dynamic material property. The high speed tensile test machine is utilized in order to identify the dynamic property of the Cu-Cr alloy at the intermediate strain-rate and the split Hopkinson pressure bar is used at the high strain-rate. Experimental results from both the quasi-static and the high strain-rate up to the 5000/sec are interpolated with respect to the amount of chrome in order to construct the Johnson-Cook and the modified Johnson-Cook model as the constitutive relation that should be applied to numerical simulation of the impact behavior of electrodes.

A Study on the Chrome of Clothing Leathers (의류용 피혁의 크롬에 관한 연구)

  • Cho, Seung-Shick;Sim, Mi-Sook;Kim, Un-Bae
    • Textile Coloration and Finishing
    • /
    • v.4 no.1
    • /
    • pp.16-20
    • /
    • 1992
  • This study was to examine the dry cleaning resistance of chrome bonding in the chrome-tanned garment leathers, and to analyze their chrome content. The results are as follows: 1. The average percentage of the chrome content (as $Cr_2O_3$) in the chrome-tanned garment leathers was 2.7%. 2. By the dry cleaning treatment and its numbers, the values of chrome content were little affected. 3. The resistance against dry cleaning with perchloroethylene $(Cl_2C = CCl_2)$ of samples was confirmed.

  • PDF

Characterization of Electro-deposited Chrome-Carbon Layer Prepared by Pulse Plating (펄스 전착된 크롬-카본 도금층의 특성)

  • Lee, J.J.;Lee, B.K.;Y.S. Pyun;Kim, Man;S.C. Kwon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.36-36
    • /
    • 2002
  • Effects of pulse-plating on the wear and corrosion resistance of chrome-carbon layers were studied. The plating were carried out at $06A/\textrm{cm}^2$ in modified Sargent bath containing formic acid at $53^{\circ}C$. The chrome layer were super-saturated with carbon up to 2.0wt. %, which precipitated as chrome carbide such as $Cr_{23}C_6$ after vacuum aging above $200^{\circ}C$ for 1 hour. This resulted in improvement of hardness and wear resistance of the chrome layer. Considering the reduction of corrosion resistance due to the thermal effect, optimum vacuum aging condition of the chrome layer in this study was I-hour at $200^{\circ}C$.

  • PDF

The Effect of Recasting on the Corrosion behavior of Ni-Cr alloy for Porcelain Fused to Metal Crown (도재용착주조관용 Ni-Cr 합금의 반복주조가 부식거동에 미치는 영향)

  • Bae, Soo-Hyun;Kim, Bu-Sob;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.355-366
    • /
    • 2006
  • The purpose of this study was to determine if repeated casting has a detrimental effect on the corrosion behavior of nickel-chrome casting alloys. The X-ray diffraction analysis, vickers hardness test, SEM, EDX and corrosion test were performed to determine the effects of recasting on chemical composition, microstructure, physical property, castability and corrosion behavior of nickel-chrome casting alloys. The X-ray diffraction analysis results for the cast and recast specimens of the VeraBond and the Rexillium V showed that major crystal phase contained nickel-chrome compounds, Nickel carbide and Chrome carbide. Microstructure analysis results for the cast and recast specimens of the VeraBond and the Rexillium V showed recasting has no effect on microstructure. EDX analysis results indicated the percentage of the main component nickel(Ni) in the specimens of the VeraBond showed a tendency to increase with recasting, but those of other components Carbon(C) showed a tendency to decrease with recasting, Chrome(Cr), Silicon(Si), Aluminium(Al) and molybdenum(Mo) showed no changes in the percentage. The percentage of the main component nickel(Ni) in the specimens of the Rexillium V showed a tendency to increase with recasting, but those of other components silicon(Si), carbon(C) and molybdenum(Mo) showed a tendency to decrease with recasting, chrome(Cr) and aluminium(Al) showed no changes in the percentage. The vickers hardness results for the cast and recast specimens of the VeraBond and the Rexillium V showed a tendency to decrease with recasting, but the differences for the first to fifth cast were not statistically significant. The castability results for the cast and recast specimens of the VeraBond and the Rexillium V showed a tendency to decrease with recasting, but the differences for the first to fifth cast were not statistically significant. The cast and recast specimens of the VeraBond and the Rexillium V showed no differences in the corrosion resistance. The results indicate that the VeraBond and the Rexillium V can be safely recast.

  • PDF

Surface Analysis of Black Chrome Solar Selective Coatings (Black Chrome 태양광 선택흡수막의 표면분석)

  • Lee, Kil-Dong;Chea, Young-Hi;Auh, Paul Chung-Moo
    • Solar Energy
    • /
    • v.9 no.2
    • /
    • pp.69-77
    • /
    • 1989
  • The thermal degradation of electroplated black chrome coating on Ni substrates has been investigated by using Auger electron spectroscopy technique. The sample was prepared by electroplating at $20^{\circ}C$ for 20 seconds with the current density at $0.4A/cm^2$. Its surface oxidation process was investigated with 1 hour annealed sample for a temperature range of $300-550^{\circ}C$. While its optical solar absorption was dominated by fine metallic Cr particles, thermal degradation was occurred primarily by oxidation of metallic Cr particles as increasing the annealing temperature.

  • PDF

A COMPARATIVE STUDY ON PHYSICAL PROPERTIES OF ORTHODONTIC STAINLESS STEEL WIRES (교정용 스테인리스강선재의 물리적 성질에 관한 비교연구)

  • Kwon, Oh-Won;Sohn, Byung-Hwn
    • The korean journal of orthodontics
    • /
    • v.15 no.2
    • /
    • pp.163-174
    • /
    • 1985
  • The requirements of orthodontic wire should include chemical stability, non-discoloration and non-corrosion in oral environment. Ability to be soldered, ease of fabrication and elasticity should be also considered. The purpose of this study was to compare and analyze the physical properties of Tru-chrome wire and manufactured E.S.S. (Experimental Stainless Steel) wire similar to Tru-chrome. The results were as follows: 1. Tru-chrome wire and E.S.S. wire were SUS 304 which was 18 Cr-8Ni austenite stainless steel. There was not significant difference in each composition between two wires. 2. There were not significant differences in ultimate tensile strength, yield strength, elongation and modulus of elasticity between Tru-chrome and E.S.S. wires. 3. There was not significant difference between flexuree modulus of elasticity of Tru-chrome and E.S.S. wires. 4. Micro-hardness value of E.S.S. wire was more than that of Tru-chrome wire and they were softened significantly by solution heat reatment. 5. Micro-structure of Tru-chrome and E.S.S. wires showed fibrous interlocking grains, and an austenite structure after solution heat treatment. 6. There was significant difference between corrosion rate of Tru-chrome and E.S.S. wires.

  • PDF

High Temperature Corrosion Properties of Heat Resistant Chrome Steels in SO2 Atmosphere (고온 이산화황 환경 내 내열 크롬강에 대한 부식특성 연구)

  • Lee, Han-sang;Jung, Jine-sung;Kim, Eui-hyun
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.2
    • /
    • pp.99-106
    • /
    • 2009
  • The high temperature corrosion properties of heat resistant steels were investigated in oxidation atmosphere including sulfur dioxide. The heat resistant steels of T22, T92, T122, T347HFG and T304H were evaluated at 620, $670^{\circ}C$ for 400 hours. The corrosion rates showed a decreasing tendency while chrome contents of those steels increased from 2 mass.% to 19 mass.%. The in crease in temperature increasement has an more effect on the corrosion rates of low chrome steels than high chrome steels. The weight gains of T22, T92, T304H at $670^{\circ}C$ were 3.7, 1.65, 1.23 times compared with those at $620^{\circ}C$. The external scale formed on T22 was composed of hematite, magnetite and Fe-Cr spinel and internal layer including iron oxide mixed with sulfide. The scales formed on T92, T122, T304H consisted of an outer layer of hematite and inner layer of chrome oxide and hematite. The proportion of chrome oxide at inner layer was increased when the chrome contents in heat resistant steels were increased.

Effective Chrome Removal Process from Shaving Dust (피혁분의 효율적인 탈 크롬 방법에 관한 연구)

  • Yun, Sun-Gyu;Park, Sung-Ha;Lee, Sang-Seob;Na, Jung-Won;Ko, Myung-Han
    • Applied Chemistry for Engineering
    • /
    • v.10 no.8
    • /
    • pp.1104-1108
    • /
    • 1999
  • In this study it was focused that if the chrome could be removed in the shaving dust, the reusable protein resource could be recycled from the shaving dust. As the chrome forms a Cr-collagenate by cross linking of collagen in the shaving dust, the dust was steeped for swelling and plumping by $Ca(OH)_2$ solution and then chromium in dust was resolved out by $H_2SO_4$ solution in the first stage process. In the second stage one, dust was swelled and plumped by NaOH solution and then the chromium in dust was oxygenated to a hexavalent chrome, which has high solubility in $H_2O_2$ solution. And then the chromium was removed byt he steeping of $H_2SO_4$ solution as the last process. The first stage process was consisted of the sequential steeping of 3%-$Ca(OH)_2$ and $0.8%-H_2SO_4$. In the second stage the total chrome was effectively removed by the sequential steeping of 0.1%-NaOH, $3%-H_2O_2$ and $1%-H_2SO_4$. In the completely dechromated dust, the humidity was measured as 10.68% and the crude protein was contained by 79.81%. Steeping solutions were reused 3 times for chrome removal process, the chrome was entirely removed in shaving dust.

  • PDF