• Title/Summary/Keyword: Chromatographic retention

Search Result 141, Processing Time 0.032 seconds

HPLC Assay and Renal Excretion Characteristics of Theophylline and Its Metabolites in Rat (테오필린과 그 대사체의 HPLC 동시 정량 및 신(腎) 배설 특성)

  • Kuh, Hyo-Jeong;Shim, Chang-Koo;Lee, Min-Hwa;Kim, Shin-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.1
    • /
    • pp.33-41
    • /
    • 1991
  • A high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of theophylline(TP) and its metabolites, 1-methyluric acid (1-MU) and 1,3-dimethyluric acid (1,3-DMU), in rat plasma and urine. An $100\;{\mu}l$ aliquot of a plasma or urine sample was mixed with $250\;{\mu}l$ of acetonitrite and vortexed. After centrifugation, $200\;{\mu}l$ (plasma) or $20\;{\mu}l$ (urine) aliquot of the supernatant was dried by $N_2$ stream and redissolved in $100\;{\mu}l$ (plasma) or $200\;{\mu}l$ (urine) of the mobile phase. A $20\;{\mu}l$ of the mobile phase solution was injected onto a $C_{18}$ reversed-phase column. The column was maintained at $45^{\circ}C$ by the aid of electric heating jacket. The mobile phase was a 3%(v/v) methanol solution in deionized water which contains sodium acetate (100 mM) and tetrabutyl ammonium hydroxide (4 mM). pH of the mobile phase was adjusted 4.5 by the addition of acetic acid. Detection limits for TP, 1-MU, and 1,3-DMU in plasma were 0.2, 0.1 and $0.1\;{\mu}/ml$, respectively and the corresponding values in urine were all $5\;{\mu}g/ml$. Inter- and intra-day variability of the assay for all compounds in the plasma samples was less than 5.5 and 3.8%, respectively. The retention times for 1-MU, 1,3-DMU, and TP were approximately 7, 8.5 and 18 min, respectively. Sample preparation procedure used in this method was simple, rapid and reproducible. Renal clearance of TP and its metabolites in rats showed plasma concentration dependency indicating renal tubular secretion and reabsorption of them.

  • PDF

Validation of a Selective Method for Simultaneous Determination of Doxifluridine and 5-Fluorouracil in Dog Plasma by LC-MS/MS (LC/MS/MS를 이용한 비글견의 혈장 중 Doxifluridine 및 5-Fluorouracil의 동시 분석법 Validation)

  • Kim, Ghee-Hwan;Kim, Won;Kim, Jin-Sung;Jin, Qingri;Kang, Won-Ku;Lee, Jong-Hwa;Ha, Jung-Heun;Jeong, Eun-Ju
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.179-186
    • /
    • 2007
  • A simple, sensitive and selective liquid chromatographic/tandem mass spectrometric method (LC-MS/MS) was developed and validated for doxifluridine and 5-fluorouracil (5-FU) quantification in dog heparinized plasma. Sample preparation was based on liquid-liquid extraction using a mixture of isopropanol/ethyl acetate (1/9 v/v) to extract doxifluridine, 5-FU and 5-chlorouracil (5-CU, an internal standard) from plasma. Chromatography was performed on a C-18 analytical column and the retention times were 2.7, 1.5 and 1.7 min for doxifluridine, 5-FU and 5-CU, respectively with shorter analysis time within 5 min than previously reported methods. The ionization was optimized using ESI negative mode and selectivity was achieved by tandem mass spectrometric analysis by multiple reaction monitoring (MRM) using the transformations of m/z 244.8>107.6, 129.0>42.0 and 144.9>42.1 for doxifluridine, 5-FU and 5-CU, respectively. The achieved low limit of quantification was 20.0 ng/mL and the assay exhibited linear range of 20-2000 ng/mL ($R^2>0.99957$ for doxifluridine and $R^2>0.99857$ for 5-FU), using $100{\mu}L$ of plasma. Accuracy and precision of quality control samples for both doxifluridine and 5-FU met KFDA and FDA Guidance criteria of 15% for accuracy with coefficients of variation less than 15%. This method demonstrated adequate sensitivity, specificity, accuracy, precision and stability to support the simultaneous analysis of doxifluridine and 5-FU in dog plasma samples in pharmacokinetic and bioequivalence studies.

Simultaneous Determination of Paeoniflorin and Glycyrrhizin in Sayuk-san by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Jeon, Min-Ji;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-Jin;Sung, Sang-Hyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.23-27
    • /
    • 2009
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, paeoniflorin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Sayuk-san (SYS). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}150mm$) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/vis detector (DAD) was used for the detection and the wavelength for quantification was set at 230 nm. The presence of paeoniflorin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. All two compounds showed good linearity ($r^2$>0.996) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 7.3% and the limits of detection (LOD) were less than 55.7 ng. The mean recovery of each compound was $102.3{\sim}111.1%$ with R.S.D. values less than 4.6%. This method was successfully applied to the determination of contents of paeoniflorin and glycyrrhizin in three commercial products of SYS. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial SYS products.

A Study on the Elution Behavior of some Metal-N-Alkylisonitrosoacetylacetone imine Chelates by Reversed Phase High Performance Liquid Chromatography (역상 액체 크로마토그래피에 의한 몇 가지 금속-N-Alkylisonitrosoacetylacetone imine 킬레이트의 용리거동에 관한 연구)

  • Kim, Yong Jun;Kewon, Ji Hae;Lee, Won
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.63-71
    • /
    • 1992
  • Liquid chromatographic behavior of Pd(II), Ni(II) and Co(III) in N-Alkylisonitrosoacetylacetone imine(HIAA-NR) chelates was investigated by reversed phase high perfomance liquid chromatography. The optimum conditions for the separation of IAA-NR-metal chelates were examined respect to the flow rate and mobile phase strength. The metal-N-Alkylisonitrosoacetylacetone imine chelates in solution were successfully separated on Novapak $C_{18}$ column using acetonitrile/water mixture as mobile phase. The elution order of chelates is methyl>ethyl>propyl>butyl as N-alkyl group for ligand is varied. It was found that all IAA-NR-metal chelates were eluted in an acceptable range of capacity factor value($0{\leq}log\;k^{\prime}{\leq}1$). The dependence of log k' on the volume fraction of water in the binary mobile phase was examined. Also, the dependence of k' on the liquid-liquid extraction distribution ratio(Dc) in acetonitrile-water-alkane extraction system was investigated for IAA-NR-metal chelate. Both kinds of dependence are linear, which suggests that the retention of the electroneutral metal chelates on Novapak $C_{18}$ column is largely due to the hydrophobic effect.

  • PDF

Simultaneous Determination of Prostaglandin E1 and Prostaglandin E1 Ethyl Ester in Hairless Mouse Skin Homogenate by High-Performance Liquid Chromatography

  • Choi, Han-Gon;Kim, Ji-Hyun;Li, Dong-Xun;Piao, Ming-Guan;Kwon, Tae-Hyub;Woo, Jong-Soo;Choi, Young-Wook;Yoo, Bang-Kyu;Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.5
    • /
    • pp.375-381
    • /
    • 2005
  • A rapid and specific high-performance liquid chromatographic method was developed and validated for the simultaneous determination of prostaglandin $E_{1}\;(PGE_{1})$ and prostaglandin $E_{1}$ ethyl ester $(PGE_{1}-EE)$ in hairless mouse skin homogenate. The sample treatment procedure involved deproteination and precipitation by acetonitrile. $PGE_{1}$ and $PGE_{1}-EE$ in supernatant were separated in a reversed-phase C18 column without being interfered by other components present in hairless mouse skin homogenate. 9-Anthracenecarboxylic acid was used as an internal standard. The retention times of $PGE_{1}$, 9-anthracenecarboxylic acid and $PGE_{1}-EE$ were, 4.5, 9.5 and 18.0 min, respectively. The assay showed linearity from 1 to $40\;{\mu}g/ml$ for both $PGE_{1}$ and $PGE_{1}-EE$. Precision expressed as RSD ranged from 2.3 to 14.1 % for $PGE_{1}$ and 1.6 to 11.0% for $PGE_{1}-EE$. Accuracy ranged from 100.5 to 119.6 % for $PGE_{1}$ and from 98.0 to 103.7% for $PGE_{1}-EE$. This method was employed successfully to follow the time course of concentrations of $PGE_{1}$ and $PGE_{1}-EE$ in hairless mouse skin homogenate for stability study.

Simultaneous determination of four fluoroquinolones in chicken, pork and beef edible muscle by HPLC (식육 중 항균물질 (플루오르퀴놀론계) 동시 다성분 분석법 개선 연구)

  • Park Dong-Yeob;Hwang Bo-Won;Cho Sung-Suk;Choi Chan-Young;Cho Sang-Lae;Park Ae-Ra;Jung Eun-Hee;Byun You-Sung
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.2
    • /
    • pp.111-122
    • /
    • 2006
  • A direct, accurate and sensitive chromatographic analytical method for quantitative determination of four fluoroquinolones (norfloxacin, cirprofloxacin, danofloxacin and enrofloxacin) in chicken, pork and beef edible muscle is proposed in the present study. The developed method was successfully applied to the determination of enrofloxacin, as the main component of commercially available veterinary drugs. The samples were homogenized and the antimicrobials were added, then they were extracted twice with dichloromethane. Fluoroquinolone antibiotics were separated on an agilent $250x4mm,\;C_{18},\;5{\mu}m$, analytical column, at $25^{\circ}C$. The mobile phase consisted of a mixture of DW : acetonitrile : triethylamine(80:19:1%, v/v, pH 3.0) leading to retention times less than 14 min. at a flow rate 0.5 ml/min. These fluoroquinolones were detected by liquid chromatography with fluorescence at 290 nm excitation and 465 nm emission. The limits of quantification in each edible muscle (chicken, pork, and beef) were 0.32-6.54 ng/g. Using 0.5 g of each sample, average recovery rates at fortification levels of 0.05, 0.1 and 0.2 ${\mu}g/ml$ ranged 70.14-71.71% for NFX, 71.87-73.89% for CFX, 82.16-92.35% for DFX, and 90.13-98.12 for EFX This is a simple and economic method to quantify the presence of NFX, CFX, EFX and DFX in edible muscle of animal origin.

Development of Isotope Dilution LC-MS/MS Method for Accurate Determination of Arsenobetaine in Oyster Certified Reference Material

  • Lee, Woo Young;Yim, Yong-Hyeon;Hwang, Euijin;Lim, Youngran;Kim, Tae Kyu;Lee, Kyoung-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.821-827
    • /
    • 2014
  • An isotope dilution liquid chromatography tandem mass spectrometry (ID LC-MS/MS) method has been developed and applied to the determination of arsenobetaine (AsB, ${(CH_3)_3}^+AsCH_2COO^-$) from oyster candidate certified reference material (CRM). The exact matching isotope dilution approach was adopted for accurate determination of AsB using $^{13}C_2$-labeled AsB as an internal standard. Efficiencies of different AsB extraction methods were evaluated using a codfish reference material and a simple sonication method was selected as the method of choice for the certification of the oyster candidate CRM. The hydrophilic interaction liquid chromatography (HILIC) combined with electrospray ionization tandem mass spectrometry (ESI/MS/MS) in selected reaction monitoring (SRM) mode was optimized for adequate chromatographic retention and robust quantification of AsB from codfish and oyster samples. By analyzing 12 subsamples taken from each 12 bottles systematically selected from the whole oyster CRM batch, the certified value of AsB was determined as $6.60mg{\cdot}kg^{-1}{\pm}0.31mg{\cdot}kg^{-1}$ and it showed excellent between-bottle homogeneity of less than 0.42%, which is represented by relative standard deviation of 12 bottles from the CRM batch. The major source of uncertainty was the certified value of the AsB standard solution.

Quantitative Analysis of Glycyrrhizic Acid in Fermented Glycyrrhizae Radix by HPLC (HPLC를 이용한 발효 감초의 지표 성분 분석)

  • Um, Young-Ran;Shim, Ki-Shuk;Lee, Jae-Hoon;Park, Hwa-Yong;Ma, Jin-Yeul
    • Korean Journal of Oriental Medicine
    • /
    • v.15 no.1
    • /
    • pp.85-89
    • /
    • 2009
  • The aim of this study was to study the quantitative analysis of glycyrrhizic acid in Glycyrrhizae Radix extract fermented with Paecilomyces japonica, Ganoderma lucidum, honey or Nuruk. The amounts of dry on loss were measured and the quantitative analysis of glycyrrhizic acid was performed by high performance liquid chromatographic (HPLC). HPLC method was performed on C18 column ($250\;mm\;{\times}\;4.6\;mm$, $5\;{\mu}m$, RS tech) using gradient solvent mixtures of water-acetonitrile with photodiode array detector (254 nm). The flow rate was $1.0\;m{\ell}/min$. Retention time of glycyrrhizic acid was about 23.96 min and linearity of calibration was $R^2$=0.9998. Contents of glycyrrhizic acid in Glycyrrhizae Radix extract (control) was $5.048\;{\pm}\;0.14$; Contents of glycyrrhizic acid in Glycyrrhizae Radix extract fermented with Paecilomyces japonica (SDT) was $1.975\;{\pm}\;0.07$; Contents of glycyrrhizic acid in Glycyrrhizae Radix extract fermented with Ganoderma lucidum (SYT) was $2.676 \;{\pm}\;0.07$; Contents of glycyrrhizic acid in Glycyrrhizae Radix extract fermented with honey (SST) was $5.191\;{\pm}\;0.06$; Contents of glycyrrhizic acid in Glycyrrhizae Radix extract fermented with Nuruk (SNT) was $5.305\;{\pm}\;0.34$, respectively. Contents of glycyrrhizic acid in SDT and SYT were decreased but that in SST and SNT was increased when compared to control.

  • PDF

Separation of Caffeine and Tryptophan Using Molded Macroporous Poly(glycidyl methacrylate-co-ethylene glycol dimethacrylate) Rods (주조된 매크로 다공성 Poly(glycidyl methacrylate-co-ethylene glycol dimethacrylate) 막대를 이용한 카페인과 트립토판의 분리)

  • Jin, Longmei;Yan, Hongyuan;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.603-608
    • /
    • 2005
  • The molded macroporous poly (glycidyl methacrylate-co-ethylene glycol dimethacrylate) rods produced by a facile molding process were polymerized in situ within a tubular mold, chromatographic column ($4.6{\times}100mm$) by free radical polymerization. It was complemented by epoxy derivatized monolithic column and chemical modification of the epoxide groups with the sulphuric acid. By variation of the polymerization conditions, such as the ratio of the monomers, the porogen (pore generating material), and the temperature, the pore size could be varied, so the retention time of the samples may be adjusted. For the mixture of caffeine and tryptophan in the prepared monolithic column, the influences of polymerization material compositions to the efficiency, selectivity, and resolution of the monolithic column were investigated.

An Improved Method for Multiresidue Analysis of Pesticides in Lettuce, Chinese Cabbage and Green Pepper by Gas Chromatography

  • Hong, Yong-Soon;Park, Hee-Won;Choi, Hoon;Moon, Joon-Kwan;Kim, Min-Jeong;Kim, Jang-Eok;Lee, Young-Deuk;Oh, Chang-Hwan;Kim, Jeong-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.3
    • /
    • pp.158-169
    • /
    • 2004
  • For the improvement of gas chromatographic analysis of multiple pesticide residues in green pepper, lettuce and Chinese cabbage, multiresidue test mixtures (MRTMs) of 10 groups (ECD 5 groups and NPD 5 groups) and a recovery test mixture (RTM) of 18 compounds (11 compounds for ECD and 7 compounds for NPD) were established based on retention time and response to relevant detectors. A new extraction solvent (acetone: acetonitrile=1 : 9) and a clean up eluent (hexane: dichloromethane : acetonitile = 50 : 48.5 : 1.5) for solid-phase extraction (SPE) cartridge were selected to test two types of multiresidue methods (MRM I and MRM II). MRM II provided high recovery better than MRM I when RTM was tested Recovery experiment with MRTMs which was conducted using MRM II resulted in that more than seventy percents of compounds were recovered in the range of $50{\sim}140%$, while 9% of compounds were over 140% of recovery and only $7{\sim}8$ compounds failed to detect. MRM II, an improved method, could be employed for screening residues of 190 pesticides in those vegetables.