• Title/Summary/Keyword: Chromatographic resolution

Search Result 112, Processing Time 0.034 seconds

A Study on the Simultaneous Determination of Residual Zeranol, Zearalenone and Their Metabolites in Beef by Gas Chromatography/Mass Spectrometry (Gas Chromatography/Mass Spectrometry에 의한 우육 중의 잔류 Zeranol, Zearalenone 및 그 대사산물들의 동시 분석법에 대한 연구)

  • 이은섭;이용욱
    • Journal of Food Hygiene and Safety
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 1994
  • A Simultaneous determination method was improved for the determination and confirmation of zeranol, zearalenone, as well as their isomers and metabolites, in beef. The analytes were extracted from tissue by CH3CN, hydrolyzed enzymatically(for glucuronide conjugates), cleaned up by a strong basic anion exchange resin combined with a liquid/liquid partitioning, derivatized using MSTFA and confirmed, quantified by GC/MS/SIM with a internal standard, zearalane. The results were as follows : (1) all the estrogens were separated on the GC/MS chromatogram under the extraction method and the chromatographic conditions improved, the retention times of zearalane-TMS2, zearalanone-TMS2, zearalenone-TMS2, zeranol-TMS3, taleranol-TMS3, and $\alpha$-zearalenol-TMS3, $\beta$-zearalenol-TMS3, were 18.49, 19.44, 19.63, 19.71, 19.79 and 19.99, 20.08 minutes, respectively. (2) The calibration curves of residual zeranol, zearalenone and their metabolites showed constantly linear(r=0.99) in the range of 5~20 ng. The minimum detection concentration of residual zeranol, zearalenone and their metabolites was 1 ppb. (3) The total average recovery of residual zeranol, zearalenone and their metabolites from spiked beef was 60.2%(CV=29.7%) at the 1 ppb and 63.5%(CV=26.5) at the 2 ppb, 72.9%(CV=18.2%) at the 4 ppb. (4) The preservation method for 6 estrogens was improved for the fast running time(21 min) and MSTFA was utilized for derivatizing 6 estrogens for improvement of recovery, for good resolution, for characteristic mass spectra unlike Jose's method and Tina's method. The utilization of zearalane as internal standard showed good quantification result for zeranol, zearalenone, as well as their isomers and metabolites, in beef.

  • PDF

Analysis of Low-level ${\alpha}$-D-glucose-1-phosphate in Thermophilic Enzyme Reaction Mixuture Using High pH Anion-exchange Chromatograph (고성능 액체 크로마토그래프를 이용한 내열성 효소반응 산물인 ${\alpha}$-D-glucose-1-phosphate의 저농도 분석)

  • 신현재;신영숙;이대실
    • KSBB Journal
    • /
    • v.14 no.3
    • /
    • pp.384-388
    • /
    • 1999
  • We have used high pH anion-exchange chromatography to analyze low level (below $20{\mu}M$) $\alpha$-D-glucose-1-phosphate (G-1-P) that can be used as a cytostatic compound, an antibiotic, and immunosuppressive drug. Our chromatographic method afforded excellent peak resolution and seletivity for glucose-6-phosphate and various maltooligosaccharides as well as G-1-P. The pulsed amperometric detector yielded linear response on G-1-P ranging from 2 - $20{\mu}M$, giving slope of $4.8{\times}10^4$(peak area/${\mu}M$). The detection limit was $2{\mu}M$. This method was applied to the purification of thermophilic $\alpha$-glucan phosphorylase from Thermus caldophilus. The technique will be extremely useful in future studies concerning carbohydrate metabolism in living organisms.

  • PDF

A New Gas-Chromatograghic Method of Organic Elemental Analysis (가스크로마토그래피에 依한 微量元素分析)

  • Kim, You-Sun;Son, Youn-Soo;Choi, Q.Won
    • Journal of the Korean Chemical Society
    • /
    • v.8 no.4
    • /
    • pp.188-191
    • /
    • 1964
  • A new gas-chromatographic method for determining carbon and hydrogen in organic compounds has been developed. After sample combustion was performed in a regular analytical combustion tube with an internal oxidant (a mixture of silver oxide and manganese dioxide) under a helium flow, the water produced was converted to acetylene by passing through a calcium carbide tube. The carbon dioxide and acetylene were trapped by a molecular sieve 5A column at room temperature. The trapped gases were released under programmed temperature raise up to $340^{\circ}C$ and the released gases were passed through a silica gel column. The adsorption of $CO_2$ and $C_2H_2$ in the molecular sieve 5A trapping column were found to be quantitative and the silica gel column showed an excellent resolution of $CO_2$ and $C_2H_2$ for analytical purpose. The analytical results for various known compounds based on the out-put of the thermal conductivity cell calibrated for the amounts of carbon and hydrogen contents in benzoic acid, showed average errors ${\pm}0.5%$ and ${\pm}0.33%$ for carbon and hydrogen, respectively.

  • PDF

Studies on the Development of Liquid Chromatographic Methods for Pesticide Residues (I)-Separation Optimization of Thiocarbamates (잔류농약의 액체 크로마토그래피 분석법 개발에 관한 연구 (I) Thiocarbamates 제초제의 분리 최적화)

  • Lee Dai Woon;Choi Yong Wook;Suh Joon Ha
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.1
    • /
    • pp.57-65
    • /
    • 1992
  • The method for investigating the retention behavior and separation optimization was studied to develop a reversed-phase liquid chromatography of eleven thiocarbamates that are used as herbicides. As an isocratic elution system, the statistical simplex technique was applied to find the optimum separation conditions. The resolution was quantitatively evaluated by using COF and ORM method. For thiocarbamate herbicides in which the elution order varies dramatically with solvent composition, the ORM method gave better result than the COF method. For the solvent composition of mobile phase in the ORM method, the ratio of methanol : acetonitrile : tetrahydrofuran : water was 16 : 29 : 2 : 53. Also in this research, an adjusted COF $(\overline{COF})$ method was proposed to rectify the defect in the current COF method, and the compositional ratio of mobile phase containing methanol : acetonitrile : water was 29.5 : 21.5 : 49.0 result of which is similar to that obtained by the ORM method.

  • PDF

Development of chemical ionization method in a GC-TOF mass spectrometer for accurate mass and isotope ratio measurement (Accurate mass 및 isotope ratio 측정을 위한 GC-TOF 질량분석기에서의 화학적 이온화방법)

  • Chung, Joo-Hee;Na, Yun-Cheol;Hwang, Geum-Sook;Shin, Jeoung-Hwa;Ahn, Yun-Gyong
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2011
  • An accurate mass and isotope ratio were determined using a gas chromatography/time of flight mass spectrometer in CI positive mode for the identification of unknown metabolites. High mass tune was used to improve the ion intensity of $[M+H]^+$. Chromatographic resolution and dynamic range enhancement were performed to obtain more reliable accurate masses and correct isotope abundance ratios. Average absolute errors of mass and isotope ratios for 24 reference metabolite -TMS (trimethylsilyl) derivatives were 6.8 ppm, 1.5% of (M+1/M ratio) and 1.7% of (M+2/M ratio), respectively. The correct formulas of twenty one compound were retrieved within top-2 hit from the heuristic algorithm for elemental composition using each accurate mass and isotope abundance ratio.

Structural evaluation of degradation products of Loteprednol using LC-MS/MS: Development of an HPLC method for analyzing process-related impurities of Loteprednol

  • Rajesh Varma Bhupatiraju;Bikshal Babu Kasimala;Lavanya Nagamalla;Fathima Sayed
    • Analytical Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.98-113
    • /
    • 2024
  • The current investigation entails the characterization of five degradation products (DPs) formed under different stress conditions of loteprednol using liquid chromatography-tandem mass spectrometry (LC-MS/MS). In addition, this study developed a stable high-performance liquid chromatography (HPLC) method for evaluating loteprednol along with impurities. The method conditions were meticulously fine-tuned which involved the exploration of the appropriate solvent, pH, flow of the mobile phase, columns, and wavelength. The method conditions were carefully chosen to successfully resolve the impurities of loteprednol and were employed in subsequent validation procedures. The stability profile of loteprednol was exposed to stress degradation experiments conducted under five conditions, and DPs were structurally characterized by employing LC-MS/MS. The chromatographic resolution of loteprednol and its impurities along with DPs was effectively achieved using a Phenomenex Luna 250 mm C18 column using 0.1 % phosphoric acid, methanol, and acetonitrile in 45:25:30 (v/v) pumped isocratically at 0.8 mL/min with 243 nm wavelength. The method produces an accurate fit calibration curve in 50-300 ㎍/mL for loteprednol and LOQ (0.05 ㎍/mL) - 0.30 ㎍/mL for its impurities with acceptable precision, accuracy, and recovery. The stress-induced degradation study revealed the degradation of loteprednol under basic, acidic, and photolytic conditions, resulting in the formation of seven distinct DPs. The efficacy of this method was validated through LC-MS/MS, which allowed for the verification of the chemical structures of the newly generated DPs of loteprednol. This method was appropriate for assessing the impurities of loteprednol and can also be appropriate for structural and quantitative assessment of its degradation products.

A rapid separation of Cs, Sr and Ba using gas pressurized extraction chromatography with inductively coupled plasma-mass spectrometry

  • Sojin Jeong;Jihye Kim;Hanul Cho;Hwakyeung Jeong;Byungman Kang;Sang Ho Lim
    • Analytical Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.123-129
    • /
    • 2024
  • We present a rapid method for the determination of Cs, Sr, and Ba, heat generators found in highly active liquid wastes, by gas-pressurized extraction chromatography (GPEC) using a column containing a cation-exchange resin. GPEC is a microscale column chromatographic technique that uses a constant flow rate of solvent (0.07 mL/min) with pressurized nitrogen gas supplied through a valve. In particular, because this method uses a small sample volume (a few hundred microliters), it produces less chemical waste and allows for faster separation compared to traditional column chromatography. In this study, we evaluated the separation of Cs, Sr, and Ba using GPEC. The eluate from the column (GPEC or conventional column chromatography) was quantitatively analyzed using inductively coupled plasma-mass spectrometry to measure the column recovery and precision. The column reproducibility of the proposed GPEC system (RSDs of recoveries) ranged from 2.7 to 4.1 %, and the column recoveries for the three elements ranged from 72 to 98% when aqueous HCl was used as the eluent. The GPEC results are slightly different in efficiency and separation resolution compared to those of conventional column chromatography because of the differences in the eluent flow rate as well as the internal diameter and length of the column. However, the two methods had similar recoveries for Cs and Sr, and the precision of GPEC was improved by two-fold. Remarkably, the solvent volume required for GPEC analysis was five times lower than that of the conventional method, and the total analysis time was 11 times shorter.

Quantification and Resolution of Dioxins on Capillary Columns (캐필러리 컬럼 종류에 따른 다이옥신 이성체 분리능과 정량 특성 변화)

  • Kim, Jong-Guk;Park, Jin-Soo;Kim, Kyoung-Sim;Lee, Geun-Hee;Kim, Shin-Jo
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.43-53
    • /
    • 2002
  • The analysis of polychlorodibenzo-p-dioxins (PCDDs) and polychlorodibenzo furans(PCDFs) was performed by using four different gas chromatographic columns (SP-2331, DB-5, DB-17 and DB-DIOXIN). The data reported is pertaining to flue gas, fly ash, ambient air, soil and fish. The difference in quantification of samples according to four columns was observed, it was noted that major difference was observed in the flue gas when compared with soil, fly ash, ambient air and fish. The quantification of the same samples according to four columns it was also found that DB-5 column have the highest concentration whereas SP-2331 column showed the lowest concentration. The quantification of DB-17 column for 1,2,3,6,7,8-HxCDF was found to be twice and three times higher when compared with other columns, whereas the quantification of DB-DIOXIN column for 1,2,3,7,8-PeCDD was also found to be over estimated twice when compared with other columns.

Separation Characteristics of Mandelic Acid in Kromasil HPLC Column (Kromasil HPLC 칼럼에서 Mandelic Acid의 분리특성)

  • Kim, Byung Lip;Kim, Jong Min;Kim, Woo Sik;Kim, In Ho
    • Korean Chemical Engineering Research
    • /
    • v.46 no.4
    • /
    • pp.681-685
    • /
    • 2008
  • Chiral separation of racemic mandelic acid was achieved on a Kromasil KR100-5CHI-TBB column. Some chromatographic parameters (resolution, number of theoretical plates, capacity factor) are calculated under different separation conditions such as changes of mobile phase compositions (hexane/t-BME = 85/15 - 10/90) as well as formic acid concentrations for adjusting pH (0.1, 0.5, 1.0 v/v%). Flow rate versus number of theoretical plates was compared to evaluate column efficiency. To determine the adsorption isotherms, PIM (Pulse Input Method) was carried out. At the concentrations of racemic mandelic acid between 0.1 and 0.3 mg/ml, L- and D-mandelic acids have the same retention times of 8.8 and 9.4 min respectively. Mandelic acid isotherms show a linear form under the concentrations of 0.3 mg/ml with eluent (hexane/t-BME = 75/25). As the concentrations of mandelic acids increase, nonlinear Langmuir isotherms were observed as $C_{S,L}=3.358C_{M,L}/(1+0.0897C_{M,L})$ for L-mandelic acid and, $C_{S,D}=3.692C_{M,D}/(1+0.1457C_{M,D})$ for D-mandelic acid.

Separation and Adsorption-Desorption Characteristics of Heavy Rare Earth Elements (Gd, Tb, Dy) using P507 Resin (P507 추출수지를 이용한 중희토류 원소(Gd, Tb, Dy)의 흡탈착 분리특성에 관한 연구)

  • Lee, Sungeun;Kim, Joung Woon;Jeon, Jong Hyuk;Jun, Hong Myeong;Lee, Jin Young;Han, Choon
    • Resources Recycling
    • /
    • v.25 no.4
    • /
    • pp.60-67
    • /
    • 2016
  • This study was conducted to establish the adsorption-desorption mechanism and the optimum condition of chromatographic operation for separations of heavy rare earth elements (Gd, Tb, Dy) using a p507-containing resin. By employing Langmuir and Freundlich isotherm together with pseudo first and second order kinetics, absorption-desorption reaction mechanism was investigated. Langmuir and Freundlich isotherm was applied under assumption that adsorption reaction occurs in form of monolayer, and because the result was identical to the assumption, now we know adsorption of heavy rare earth elements occurs in form of monolayer. Concerning the pseudo first and second order kinetic, the pseudo second order seemed to be more suitable to represent heavy rare earth element adsorption mechanism. By using the extraction chromatography to separate heavy rare earth elements, ${\alpha}^{Tb}_{Gd}=1.24$, and ${\alpha}^{Dy}_{Tb}=1.03$ were confirmed in eluent HCl 0.25 M which indicates almost perfect separations of three elements. Furthermore, as concentrations of eluent became higher, the resolution value decreased and the elution area got shortened.