• Title/Summary/Keyword: Chromatograph

Search Result 430, Processing Time 0.023 seconds

A study on the analysis of artificial sweeteners in processed foods including emulsified foods by HPLC-DAD

  • Kim, Min-Hee;Lee, Do-Yeon;Ahn, Jang-Hyuk
    • Analytical Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.209-214
    • /
    • 2020
  • This study has been carried out to develop a standard method for quantifying of 3 permitted artificial sweeteners (including sodium saccharine, aspartame, acesulfame potassium) contained in foods by HPLC-DAD. A simple and rapid sample pretreatment method was used to remove fat and protein from the test solution with Carrez clearing regent precipitant know to be effective for protein and fat removal. The artificial sweeteners in the test solution purified through sample pretreatment were detected by high performance liquid chromatograph using a Reverse phase C18 column (5 ㎛, 4.6 × 250 mm). The simultaneous quantitative test of 3 kinds of artificial sweeteners can be effectively performed on the high fat emulsified foods containing a large amount of fat. Using the established simultaneous quantitative test method, artificial sweeteners were tested in foods such as dairy products, snacks and chocolate. The results calibration curve showed good linearity with high regression coefficients and the result of recovery test showed satisfactory recoveries within 80~110 %.

Analysis of Perchlorate in Water Using Ion Chromatograph with Preconcentration (이온크로마토그래프를 이용한 수중의 퍼클로레이트 농축 및 분석)

  • Kim, Hak-Chul
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.4 s.62
    • /
    • pp.29-38
    • /
    • 2006
  • This study included the development of analytical method for determining perchlorate in water sample. The analytical condition was referred in EPA 314.0 method which use ion chromatography and the concentrator column was replaced by the guard column. Concentrating 10mL raw or treated water sample on to AGl6 guard column made it possible to get the LOD(Limit of Detection) of $0.73\;{\mu}g/L$. The total run time was 11 minutes and during run time next sample could be concentrated on AGl6 guard column. Compared to the Concentration method which needed manual operation, the Direct Injection method could screen the many water samples. The LOD of the Direct Injection method was higher and the sensitivity was lower than that of the Concentration method. The RSDs(Relative Standard Deviations) were lower than 2.5 % for peak height and 0.7 % for retention time in pre-concentration methods. This method Showed good reproducibility and reliability and it was thought the deviations of recovery value could be reduced by considering column capacity and making water sample homogeneous. Matrix Elimination could be done using the pre-concentration method if perchlorate were in complex matrix of sample.

Beneficial Effects of Lactobacillus casei ATCC 334 on Halitosis Induced by Periodontopathogens

  • Lee, Ki-Ho;Baek, Dong-Heon
    • International Journal of Oral Biology
    • /
    • v.39 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • Halitosis is caused by consumption of certain foods or drinks and production of volatile sulfur compounds (VSCs) by periodontopathogens. VSCs-related halitosis is not easily removed using mechanical or chemical therapies such as dental floss, plaque control and mouth rinse. Lactobacillus are known to be probiotics and stimulate immune systems of human. Furthermore, L. casei ATCC 334 and L. rhamnosus GG have an effect on protection of dental caries in vitro studies. The aim of this study was to investigate effect of Lactobacillus on halitosis by Fusobacterium nucleatum- and Porphyromonas gingivalis-producing VSCs and to analyze inhibitory mechanism. The periodontopathogens were cultivated in the presence or the absence Lactobacillus, and the level of VSCs was measured by gas chromatograph. For analysis of inhibitory mechanisms, the susceptibility assay of the spent culture medium of Lactobacillus against F. nucleatum and P. gingivalis was investigated. Also, the spent culture medium of Lactobacillus and periodontopathogens were mixed, and the emission of VSCs from the spent culture medium was measured by gas chromatograph. L. casei and L. rhamnosus significantly reduced production of VSCs. L. casei and L. rhamnosus exhibited strong antibacterial activity against F. nucleatum and P. gingivalis. The spent culture medium of L. casei inhibited to emit gaseous hydrogen sulfide, methyl mercaptan and dimethyl sulfide from the spent culture medium of periodontopathogens. However, the spent medium of L. rhamnosus repressed only dimethyl sulfide. L. casei ATCC 334 may improve halitosis by growth inhibition of periodontopathogens and reduction of VSCs emission.

Development of an Auto Dilution Unit of Substrate Solutionfor a Flow Injection Type Biosensor (흐름주입식 바이오센서용 기질용액 자동희석 장치 개발)

  • Song, D.B.;Jung, H.S.;Jung, D.H.;Kim, S.T.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.443-448
    • /
    • 2006
  • For development of an on-line monitoring unit of fermentation process, an auto dilution unit based on traditional chemical and biological analytical method was developed and the performance was evaluated. The dilution unit was constructed with two syringe pumps and flow direction change valves and fully automated. Total delivery volume of two pumps using distilled water was measured to confirm the operating stability And diluted concentrations of three substrate solutions (glucose, lactic acid, ethanol) were compared with a standard method with a high performance liquid chromatograph (glucose, lactic acid) and gas chromatograph (ethanol). Relative error values of total delivery volume of the pumps were below 3% and standard deviation values were 0.003 (n=5). Relative error values of diluted concentration of the dilution unit measurements were below 2% with 1/10 of dilution ratio and 70, $80{\mu}{\ell}$ of sample volume conditions for glucose and lactic acid, 1/30 of dilution ratio and $70{\mu}{\ell}$ of sample volume conditions for ethanol, respectively. In case of the ethanol, cause of the evaporative characteristics, the relative error values showed over 5% whole experimental conditions.

Simultaneous detection method for pesticide residues in meat by gas chromatograph-mass selective detector (Gas chromatograph-mass selective detector를 이용한 식육 중 잔류농약의 동시분석)

  • Hong In-Suk;Choi Yoon-Hwa;Kweon Taek-Boo;Lee Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.28 no.3
    • /
    • pp.285-294
    • /
    • 2005
  • This study was conducted to investigate the extraction method for the determination of organochlorine, organophosphorus and synthetic pyrethroid pesticide residues in beef fat by gas chromatography-mass selective detector(GC-MSD). Twenty one pesticide residues in fat were determined using a simple and rapid procedure based on solid- phase extraction(SPE) clean-up cartridges with octadecyl $(C_{18})-bonded$ porous silica, florisil, $10\%$ deactivated florisil. a tandem $C_{18}$ and florisil and a tandem $C_{18}$ and $10\%$ deactivated florisil. Solvent-solvent extraction using acetonitrile was not satisfied to eliminate fat interference for pesticide residue analysis by GC-MSD, and the recoveries of the method in fat ranged from 16.2 to $57.3\%$ except DDT$(83.2\%)$. The recoveries of SPE methods using a tandem $C_{18}$ and Florisil was $59.6\~123.8\%$ except fenitrothion $(135.2\%)$. the SPE method was verified the satisfactory performance of pre-treatment for pesticide residues analysis in fat by GC-MSD. The efficiency of florisil deactivated with $10\%$ water has been not proved significantly on recoveries of pesticide residues in fat.

Comparison of Analytical Methods for DEHP Migration from PVC Bags for Blood Storage and Infusion; By Gas Chromatography and UV-vis Spectrophotometry (혈액·수액용 PVC 백에서 용출된 DEHP의 검출 분석 방법 비교; 기체 크로마토그래프와 분광 광도계)

  • Kim, Jung Hwan;Kim, Seong Hun;Choi, Hyeong Ki;Lee, Chang Hyung
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.72-79
    • /
    • 2002
  • Di-(2-ethylhexyl)phthalate (DEHP) may be released from plasticized poly(vinyl chloride) (PVC) articles. In the cases of various methods for the quantitative analysis of migrating DEHP, there are much differences in migrating quantity according to the experimental methods. It is therefore important to make the comparison and analysis between these two results. A study of DEHP migration from blood and infusion bags has been carried out in different methods to evaluate the amount of DEHP migration using gas chromatograph and UV-vis spectrophotometry. Five PVC bags were cut into plane sheets in size of $40{\times}10{\times}0.4mm$, then were immersed in extraction solvent for an hour to release DEHP. It was determined by a gas chromatograph that $23.2{\sim}70.9{\mu}g/mL$ of DEHP was extracted. While extraction solvent was injected into PVC bags which were then placed for an hour to leach DEHP out. It was checked by a UV-vis spectrophotometer that the concentration of DEHP in extraction solvent was $24.8{\sim}41.3{\mu}g/mL$. Two results show different values according to the extraction conditions and experimental methods and the gas chromatographic results were converted into UV-vis spectroscopic results on condition that DEHP would be extracted equally per unit time and unit contact area. It was concluded that DEHP migrating amounts are approximately equal in two analytical methods.

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

Development and validation of an analytical method for the determination of lepimectin residues by HPLC-PDA (HPLC-PDA를 이용한 lepimectin 잔류량 분석법 개발 및 확인)

  • Do, Jung-Ah;Kwon, Ji-Eun;Kim, Mi-Ra;Lee, Eun-Mi;Kuk, Ju-Hee;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.142-153
    • /
    • 2013
  • A new, rapid, and simple analytical method was developed and validated using high performance liquid chromatograph-photodiode array detector (HPLC-PAD) for the determination of lepimectin residues in agricultural commodities. The lepimectin residues in samples were extracted with methanol, partitioned with dichloromethane, and then purified with glass column filled with subsequently to aminopropyl ($NH_2$) solid phase extraction (SPE) cartridge. The purified samples were detected using HPLC-PAD. Correlation coefficient ($R^2$) of both lepimectin $A_3$ and $A_4$ solutions were 0.9999. The method was validated using cucumber spiked with lepimectin at 0.02 and 0.2 mg/kg and pepper, mandarin, hulled rice, potato, soybean at 0.02 and 0.5 mg/kg. Average recoveries were 76.0~114.8% with relative standard deviation less than 10%, and limit of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.01 mg/kg, respectively. The result of recoveries and overall coefficient of variation of a laboratory results in Gwangju regional KFDA and Daejeon regional KFDA was followed with Codex guideline (CAC/GL 40). Therefore, developed method in this study is accurate, rapid, and appropriate for lepimectin determination and will be used to keep safety of lepimectin residues in agricultural products.

Determination of trace impurities of HFC-134a by gas chromatograph with atomic emission detector (GC/AED) (GC/AED를 이용한 HFC-134a의 미량 불순물 분석)

  • Kim, Myeongja;Lim, Jeongsik;Lee, Jinbok;Lee, Jeongsoon
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.240-251
    • /
    • 2017
  • 1,1,1,2-Tetrafluoroethane (HFC-134a), which is used as refrigerant in air conditioners, has been recently regulated as a greenhouse gas and is recommended for reuse by refining. It is very important to quantitatively analyze trace impurities present in the refrigerant to evaluate the criteria for reuse. In this study, trace impurities including C, H, Cl, and F, which are difficult to quantify because there are no reference materials, were quantitatively analyzed by a gas chromatograph-atomic emission detector (GC/AED); for this analysis, this was preceded by a qualitative analysis with a GC-mass selective detector (GC/MSD). In addition, the AED response was investigated using a hydrocarbon mixed reference material, which was proportional to the number of atoms in the component. Fifteen refrigerant components were detected as trace impurities in HFC-134a by qualitative analysis of trace impurities including C, H, Cl, and F in the samples. Based on the results of the qualitative analysis, quantitative analysis of trace impurities using AED showed that the highest mole fractions were for the $CHClF_2$ component ($45438.38{\mu}mol/mol$) in one sample and for the $C_2H_2ClF_3$ component ($1311.47{\mu}mol/mol$) in another sample. From this study, it has been shown that it is possible for this analytical method to be applied to the qualitative and quantitative analysis of trace compounds in refrigerants, which are difficult to quantify because of the absence of reference materials.

Analysis of Aroma Pattern of Panax Species by Potable Handheld Gas Chromatograph (Potable handheld gas chromatograph(PHGC)를 이용한 인삼속(Panax species) 식물들의 향기패턴 분석)

  • Lee, Boo-Yong;Yang, Young-Min;Lee, Oak-Hwan;Kim, Kyung-Im
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.862-866
    • /
    • 2002
  • This study was performed to analyze aroma pattern of Panax species (Korean Panax ginseng C.A. Meyer, Chinese Panax ginseng C.A. Meyer, Panax quinquefolium L, and Panax notoginseng F.H. Chen) by the PHGC (potable handheld gas chromatograph). Ratios of several peak areas in chromatogram of derivative parrtern were as follows. If ratio of Korean Panax ginseng was 1, Panax notoginseng was $0.030{\sim}0.674$, Chinese Panax ginseng was $0.005{\sim}0.212$ and panax quinquefolium was $0.241{\sim}0.871$. Ratios of peak area at $Rt_{20.02}$ were that if Korean panax ginseng was 1, Chinese Panax ginseng was 0.212, Panax quinquefolium was 0.343 and Panax notoginseng was 0.065. Ratios also of peak area at $Rt_{21.70}\;and\;Rt_{24.90}$ showed clear difference among aroma patterns of Panax specie cultivars. Flavor component at $Rt_{26.15}$ was not detected in Panax quinquefolium and Panax notoginseng but in Korean Panax ginseng and Chinese Panax ginseng. Ratios of peak area at $Rt_{26.15}$ were that if Korean Panax ginseng was 1, Chinese Panax ginseng was 0.185. And so habitat of Panax species cultivars was discriminated. Cultivar and habitat of dried panax species was remarkably distinguised by the chromatogram of frequency pattern, derivative pattern and visual pattern using olfactory images known as Vapor $print^{TM}$.