• 제목/요약/키워드: Chopping pattern

검색결과 11건 처리시간 0.026초

고유수용성신경근촉진법 내려치기 패턴 훈련이 편측무시가 있는 뇌졸중 환자의 편측무시, 균형능력 및 일상생활수행능력에 미치는 영향: 무작위 임상 시험 (Effect of Proprioceptive Neuromuscular Facilitation Chopping Pattern on Neglect, Balance, and Activity of Daily Living of Stroke Patients with Hemi-Spatial Neglect: A randomized clinical trial)

  • 강태우;김범룡
    • 대한물리의학회지
    • /
    • 제14권2호
    • /
    • pp.107-115
    • /
    • 2019
  • PURPOSE: This study examined the effects of the chopping pattern of proprioceptive neuromuscular facilitation (PNF) on the neglect, balance ability, and activities of daily living in stroke patients with hemi-spatial neglect. METHODS: Twenty stroke patients with neglect volunteered for this study. The subjects were assigned randomly to either the experimental group (EG, n=10) or control group (CG, n=10). The chopping pattern of PNF and exercise therapy were applied in the EG and CG, respectively, for four weeks. Neglect, balance, and activities of daily living were evaluated at the pre-and post-intervention. The assessment tools included a line-bisection test, balance test using Space balance 3D, and modified Barthel index. The pre-and post-intervention values were compared in each group using a paired t-test and the between-group differences were assessed using an independent t-test. Statistical significance was set to ${\alpha}=.05$ for all variables. RESULTS: Significant differences were observed between the EG and CG in terms of neglect, balance, and activities of daily living (p<.05). Both groups showed significant improvement in neglect, balance, and activities of daily living (p<.05). CONCLUSION: These results suggest that the chopping pattern of PNF is effective in improving the hemi-spatial neglect, balance, and activities of daily living in stroke patients with neglect.

만성 뇌졸중 환자에게 PNF 내려치기와 들어올리기 패턴을 이용한 운동이 호흡기능에 미치는 영향 (Effects of Exercise using PNF Chopping and Lifting Pattern on the Respiratory Function of Chronic Stroke Patients)

  • 권교임;조용호
    • 대한물리의학회지
    • /
    • 제16권4호
    • /
    • pp.77-83
    • /
    • 2021
  • PURPOSE: This study examined the changes in the respiratory function when PNF chopping and lifting patterns were used in chronic stroke patients METHOD: The subjects were 30 patients diagnosed with chronic stroke. The respiratory function (FVC, FEV1, and FEV1/FVC) were measured by spirometry. Thirty subjects were divided randomly into an experimental group to which 15 PNF chopping and lifting were applied and a control group to which chest breathing exercise was performed. The intervention was conducted three times a week for six 6 weeks. To examine the effects of intervention, the pre- and post-intervention values for each group were compared using a paired t-test. An independent t-test was used to compare the differences in the values of changes pre- and post-intervention in the two groups. Statistical significance was set to .05. RESULTS: Satistically significant differences in FVC and FEV1 were observed in both the experimental group and control group according to the intervention (p < .05). A statistically significant difference was found in FVC and FEV1 compared to values of changes pre- and post-intervnetion between the experimental and control groups. There was no difference in FEV1/FVC. CONCLUSION: The results suggest that PNF chopping and lifting can be applied as an excellent respiratory intervention program compared to general chest breathing exercises to improve respiratory function in stroke patients.

분로리액터 개폐 과전압 해석을 위한 EMTP 모델링 (Electromagnetic Transient Program Modeling for Analysis of Switching Over-Voltage on Shunt Reactor)

  • 오승열;전인영;한기선;강지원
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.393-397
    • /
    • 2020
  • 무효전력 보상설비인 분로리액터는 전력계통의 부하 패턴에 따라서 하루에도 수 회 정도 차단기에 의해 운전되거나 정지된다. 분로리액터개폐 시 몇 가지 요인에 의해 발생하는 과전압은 차단기의 절연 성능을 저하시키며, 계통을 구성하는 전력기기에 심각한 전압 스트레스를 유발한다. 분로리액터 개폐 과정에서 발생하는 과도현상을 측정하는 것은 계통을 모의하여 차단기 성능을 검증하는 시험소 수준에서는 가능하나, 실제 계통 운전 중에 발생하는 과도현상을 측정하는 것은 여러 가지 제약으로 어려움이 있다. 따라서 본 논문에서는 실 계통에서 지상 소전류 차단과정에서 가혹한 과도회복전압(TRV: Transient Recovery Voltage)을 유발하는 재발호(reignition)나 전류재단(current chopping) 현상에 대한 해석을 위해 전자계과도해석프로그램(EMTP: Electro-magnetic Transients Program)을 활용한 모델링 과정과 이를 토대로 분로리액터 개폐 과정에서 차단기의 고장을 유발하는 주된 현상에 대해 해석하고자 한다.

만성 요통환자에 대한 PNF와 체간운동프로그램이 통증, 기능장애 및 균형에 미치는 효과 (The Effects of PNF Technique Versus Trunk Exercise Program on the Pain, Disability and Balance in Chronic LBP Patients)

  • 전혜진;이문환
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.665-673
    • /
    • 2009
  • 본 연구는 만성요통환자 30명을 대상으로 PNF와 체간 운동프로그램을 적용한 다음 환자들의 통증, 기능장애 그리고 정적균형과 동적균형에 미치는 효과에 대해 알아보기 위해 실시하였다. 각 군의 운동효과를 측정하기 위해 모든 대상자는 통증과 함께 Oswestry 장애지수와 외다리기립검사를 통해 정적균형을 측정하였고, Balance 측정기를 이용하여 동적균형을 측정하였다. 그 결과 통증, Oswestry 장애지수, 외다리 기립검사 및 동적균형 모두 체간운동군에 비해 PNF 군이 유의한 차이가 있었다(p<0.05). 따라서 이번 연구결과를 통해 알 수 있는 것은 PNF의 내려치기와 들어올리기 패턴이 만성 요통환자에게 효과적이라는 것을 알 수 있다.

정상교합자와 골격성 III급 부정교합자의 저작운동형태의 비교 (A Comparative Study on Chewing Movement in Normal Occlusion and Skeletal Class III Malocclusion)

  • 성기혁;성재현
    • 대한치과교정학회지
    • /
    • 제27권5호
    • /
    • pp.801-813
    • /
    • 1997
  • 정상교합자와 골격성 III급 부정교합자의 저작운동형태를 비교연구하기위해서 30명의 정상교합자와 20명의 골격성 III급 부정교합자를 대상으로 츄잉검을 사용하고 BioPAK system을 이용하여 전두면상에서 저작운동을 기록, 분석하였다. 각 개체마다 대표하는 저작경로를 정하여 저작폭경, 개구거리, 개구각, 페구각, 최대개구속도, 최대폐구속도를 알아보았다. 또 저작경로의 형태에 따라 특징적인 7가지 패턴으로 분류하여 다음의 결과를 얻었다. 1. 정상교합자군에 비해 골격성 III급 부정교합자군에서는 좀 더 다양하고 수직적인 저작양상을 나타내었다. 2. 저작폭경의 비교에서는 골격성 III급 부정교합자군이 정상교합자군에 비해 더 좁게 나타났다(p<0.01) 3. 개구거리에서는 골격성 III급 부정교합자군이 정상교합자군에 비해 더 작게 나타났으나 통계학적으로 유의성은 없었다(p>0.05). 4. 개구각과 폐구각에서는 골격성 III급 부정교합자군에서 정상교합자군보다 더욱 예각으로 나타났다(p<0.01). 5. 최대개구속도, 최대폐구속도에서는 정상교합자군에 비해 골격성 III급 부정교합자군에서 느리게 나타났으나 통계학적으로 유의성은 없었다(p>0.05). 6. 저작운동형태에 따른 분류에서 정상교합자군에서는 Type II가 73.4%로 가장 많은 비율을 차지하였으나, 골격성 III 급 부정교합자군에서는 Type III가 35.0%, Type II가 30.0%로 많은 비율을 차지하였다. 7. 저작운동형 태에 따른 분류에서 골격성 III급 부정교합자군에서는 Type IV(chopping type)가 25.0%로 정상교합자군 3.3%에 비해 많은 비율을 차지하였다.

  • PDF

스트로보스코픽 전자 스페클 패턴 간섭법을 이용한 디스크 브레이크의 진동 모드의 정량적 가시화에 관한 연구 (A Study on Quantitiative visualization of Vibration Mode Shape of Disk Brake by Using Stroboscopic ESPI)

  • 강영준
    • 한국자동차공학회논문집
    • /
    • 제7권9호
    • /
    • pp.97-104
    • /
    • 1999
  • Brake squeal noise has been a problem since the early days of motoring . It is important to obtain vibration mode shape for reduction of brake noise . Stroboscopic Electronic Speckle Pattern Interferometry is a very powerful measuring method for study of vibrating objects in static state compared with conventional methods because this method can give both resonance frequency and quantitative visualization of vibration mode shape at the same time. In this paper, we performed qualitative visualization and quantitative analysis of vibration mode shpae of disk brake by using stroboscopic ESPI and phase shifting method. The stroboscopic wavefronts are obtained by chopping continuous wave laser beam using acousto-optic modulator .Experiments were performed at the same constraint conditions as disk brake of the practical vehicle as far as possible. The experimental results of this paper show quantitative measurement of vibration mode shape and quantiative visualization of vibration amplitude of disk brake with 3D plotting.

  • PDF

가변속 유도 전동기를 구동하기 위한 PWM인버터의 새로운 변조 방식 (A Novel Modulation Techniques for Driving a Variable-Speed Induction Motor)

  • 윤병도;전희종;김국진;정율기;손진근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.600-604
    • /
    • 1991
  • In this paper, an advanced PWM modulation strategy for driving a variable-speed induction motor is introduced. According to this method, the technique of efficiently eliminating harmonics component is achived. A switching pattern was computed making use of the near-proportionality of voltage and frequency in AC machines operating with constant flux. At low magnitudes and low frequencies of the foundamental, many more harmonics are eliminated than at high magnitudes and frequencies. In order to keep the inverter switching frequency constant over the output frequency range, chopping times diminishes as the frequency of the fundamental increases.

  • PDF

가변속 유도전동기의 구동을 위한 PWM인버터의 다단변조 기법 (Multi-step Modulation Techniques in PWM Inverter for a Variable-Speed Induction Motor Driving)

  • 박충규;정헌상;김국진;정을기;손진근
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권6호
    • /
    • pp.32-41
    • /
    • 1992
  • In this paper, an advanced Pulse Width Modulation Inverter strategy for driving a variable-speed induction motor is introduced. A switching pattern making use of the near-proportionality of voltage and frequency in AC machines operating with constant flux was computed. At low magnitudes and ow frequencies of the fundamental, many more harmonics are eliminated than at high magnitudes and frequencies. In order to keep the inverter switching frequency constant over the output frequency range, the chopping frequency is diminished as the frequency of the fundamental increases. Using these modulation strategy, the harmonics components of PWM inverter are efficiently eliminated.

  • PDF

Measurement of electron density of atmospheric pressure Ne plasma jet by laser heterodyne Interferometer with voltage

  • Lim, Jun Sup;Hong, Young June;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.140.1-140.1
    • /
    • 2015
  • Currently, As Plasma application is expanded to the industrial and medical industrial, Low temperature plasma characteristics became important. Especially in Medical industrial, Low temperature plasma directly adapted to human skin, so their plasma parameter is important. One of the plasma parameters is electron density, some kinds of method to measuring electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods is expensive to composed of experiment system. Heterodyne interferometer system is cheap and simple to setting up, So we tried to measuring electron density by Laser heterodyne interferometer. To measuring electron density at atmospheric pressure, we need to obtain the phase shift signal. And we use a heterodyne interferometer. Our guiding laser is Helium-Neon laser which generated 632 nm laser. We set up to chopper which can make a laser signal like a pulse. Chopper can make a 4 kHz chopping. We used Needle jet as Ne plasma sources. Interference pattern is changed by refractive index of electron density. As this refractive index change, phase shift was occurred. Electron density is changed from Townsend discharge's electron bombardment, so we observed phenomena and calculated phase shift. Finally, we measured electron density by refractive index and electron density relationship. The calculated electron density value is approximately 1015~1016 cm-3. And we studied electron density value with voltage.

  • PDF

균형측 교합장애로 인한 하악운동 및 저작근 활성도의 변화에 관한 연구 (A STUDY ON THE CHANCE OF MANDIBULAR MOVEMENT AND MASTICATORY MUSCLE ACTIVITY REFLECTED BY BALANCING-SIDE OCCLUSAL INTERFERENCE)

  • 이윤정;박남수;최부병
    • 대한치과보철학회지
    • /
    • 제36권4호
    • /
    • pp.533-548
    • /
    • 1998
  • The purpose of this study was to investigate the influence of balancing interference on the mandibular movement and masticatory muscle activity. 5 subjects(male. average age of 24.3) without dysfuction in masticatory system were selected. The balancing interference was provided by construction of cast metal crown and onlay on the upper and lower first molars. Clinical examination, changes displacement and velocity, and muscle activity were recorded and analyzed by means of BioPak system(Bioresearch Inc., Milwaukee Wisconsin. USA). The results were as follows ; 1. In clinical examination, various symptoms were reported by all subjects after application of interference. Almost symptoms were subsided after elimination of interference. 2. In the border movements in frontal plane, lateral border movement toward non-interference side was changed according to the interference after application of interference. Immediately after removal of interference, border movements' pattern was recovered as same as before experiment. 3. During gum chewing on the non-interference side, horizontal movement was decreased immediately after application of interference(p<0.05). 1 week after application of interference, horizontal movement was more decreased in 3 subjects and showed a chopping type masticatory stroke. But in 2subjects, horizontal movement was increased to avoid interference. 4. In EMG of the mandibular rest position, no significant changes were showed in the experiment period(p>0.05). 5. During gum chewing on the interference side, the activity of opposite temporal muscle was increased immediately after application of interference(p<0.05). 1 week after application of interference. The activity of ipsilateral temporal muscle and left and right masseter muscles was increased (p<0.05). 1 week after elimination of interference, increased muscle activity was recovered about the same level as before experiment. 6. During gum chewing on the non-interference side, 1 week after application of interference, the activity of ipsilateral temporal muscle was increased (p<0.05). 1 week after elimination of interference. increased muscle activity was returned about the same level as before experiment.

  • PDF