• Title/Summary/Keyword: Chloride removal

Search Result 331, Processing Time 0.026 seconds

Production of Fine Cobalt Metal Powders from Stellite Scrap (Stellite 스크랩으로 부터 Co 미분말의 제조)

  • 박문경;신동성
    • Resources Recycling
    • /
    • v.3 no.1
    • /
    • pp.9-16
    • /
    • 1994
  • Fine cobalt metal powders was produced from domestic Stellite scrap by decomposing it with molten sodium hydroxide. Complete decomposition of the scrap could be obtained with the weigth ratio of sodium hydroxide to Stellite being about 2 at the temperature ranges of $750~800^{\circ}C$ for an hour. The cobalt-bearing compound was identified as $Co_2O_3{\dot}H_2O$ by X-ray analysis and D.T.-T.G.a.. The compound was then digested in HCI to form cobalt chloride, and after iron removal by adjusting the pH of the solution, cobaltous or cobaltic hydroxide was precipitated at the pH of about 13 or 4, respectively. The precipitates were reduced by hydrogen in the temperatures of $400~500^{\circ}C$ to fine cobalt powders of high purity with the size of 1.0 to $1.5\mu\textrm{m}$. The recovery of cobalt from Stellite scrap was about 75~86% by weight.

  • PDF

Nickel Ion Adsorption Behavior of Ceriporia lacerata Isolated from Mine Tailings in Korea

  • Kim, HaeWon;Lim, Jeong-Muk;Oh, Sae-Gang;Kamala-Kannan, Seralathan;Cho, Min;Oh, Byung-Taek
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.2
    • /
    • pp.22-31
    • /
    • 2015
  • In the present study, surface of laccase producing Ceriporia lacerata was modified using 4-bromobutyryl chloride and polyethylenimine. The modified biomass was freeze dried and utilized as a biosorbent for the removal of Ni(II) from aqueous solution. The physicochemical properties of the biosorbent were analyzed using scanning electron microscopy and Fourier transform infrared spectroscopy. Batch experiments were carried out as a function of contact time (0-60 min), pH (2 to 8), adsorbent dosage (25-150 mg), and initial Ni(II) concentration (25-125 mg/L). The results indicate that surface modified biosorbent effectively adsorbed (9.5 mg/0.1 g biomass) Ni(II) present in the solution. The equilibrium adsorption data were modeled with different kinetic and isotherm models. The Ni(II) adsorption followed pseudo-first-order kinetics (R2 = 0.998) and Langmuir isotherm (R2 = 0.994) model. Hydroxyl and carbonyl functional groups present in biomass play a major role in the adsorption of Ni(II). The adsorbed Ni(II) from the biosorbent was successfully desorbed (85%) by 1M HCl. The results of the study indicate that the surface modified C. lacerate biomass could be used for the treatment of Ni(II) contaminated ground waters.

Preparation and Characteristics of Poly(phenylene ether)s in Various Reaction Conditions (다양한 반응조건에 따른 폴리페닐렌에테르의 중합 특성)

  • Park, Jong-Hyun;Kim, Nam-Cheol;Kim, Yong-Tae;Nam, Sung-Woo;Kim, Young-Jun;Kim, Ji-Heung
    • Polymer(Korea)
    • /
    • v.35 no.3
    • /
    • pp.244-248
    • /
    • 2011
  • Poly(2,6-dimethyl-1,4-phenylene ether) (PPE) was synthesized by oxidative polymerization using various Cu(I)-amine catalyst system. The effects of catalyst/monomer ratio, different amine ligand, and the content of 2,4,6-trimethylphenol (TMP) additive on the polymer yield and molecular weight were investigated by using gel permeation chromatography. The catalytic activity of various Cu-amine systems on the 2,S-dimethylphenol (DMP) polymerization was monitored and compared each other through oxygen-uptake experiment. In addition, the effect of catalyst removal using aqueous EDTA on the thermal stability of the prepared polymer was elucidated by thermogravimetric analysis.

Field Study on Application of Reactive Zone Technology Using Zero-Valent Iron Nanoparticles for Remediation of TCE-Contaminated Groundwater (TCE 오염 지하수의 정화를 위한 나노영가철 기반 반응존 공법의 현장 적용성 연구)

  • Ahn, Jun-Young;Kim, Cheolyong;Hwang, Kyung-Yup;Jun, Seong-Chun;Hwang, Inseong
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.80-90
    • /
    • 2014
  • The laboratory and field studies were conducted to identify an optimal injection concentration of nanoscale zero-valent iron particles (NZVI) and to evaluate the applicability of NZVI-based reactive zone technology to the site contaminated with trichloroethylene (TCE) DNAPL (Dense Non-Aqueous Phase Liquid). The laboratory test found an optimal injection concentration of NZVI of 5 g/L that could remove more than 95% of 0.15 mM TCE within 20 days. Eleven test wells were installed at the aquifer that was mainly composed of alluvial and weathered soils at a strong oxic condition with dissolved oxygen concentration of 3.50 mg/L and oxidation-reduction potential of 301 mV. NZVI of total 30 kg were successfully injected using a centrifugal pump. After 60 days from the NZVI injection, 86.2% of the TCE initially present in the groundwater was removed and the mass of TCE removed was 405 g. Nonchlorinated products such as ethane and ethene were detected in the groundwater samples. Based on the increased chloride ion concentration at the site, the mass of TCE removed was estimated to be 1.52 kg. This implied the presence of DNAPL TCE which contributed to a higher estimate of TCE removal than that based on the TCE concentration change.

Effects of C/N Ratio on Removal of Organic Matter and Nitrogen in Alternately Intermittently Aerated Nonwoven Fabric Filter Bioreactor (교대로 간헐 포기되는 부직포 여과막 생물반응조에서 C/N비가 유기물 및 질소 제거효율에 미치는 영향)

  • Ahn, Yun-Chan;Bae, Min-Su;Lee, Jong-Ho;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.499-506
    • /
    • 2005
  • This study was performed to investigate the effects of influent C/N ratio on the removal of organic and nitrogenous compounds by two nonwoven fabric filter bioreactors. The reactors were alternately aerated at an aeration/nonaeration period ratio of 60 min/60 min, and fed with wastewater only during nonaeration period. The influent C/N ratio (COD/TKN) was gradually reduced from 10 to 2. The influent was prepared by diluting the leachate from a foodwaste treatment facility in I city so that the COD concentration could be about 2,500 mg/L. The C/N ratio of the wastewater was adjusted by adding ammonium chloride. The results of the experiment showed that the COD and BOD concentration of the effluent was $40{\sim}54\;mg/L$ and $1{\sim}4\;mg/L$, respectively at the C/N ratios of $10{\sim}3$, and the effluent SS concentration was always below 2.0 mg/L. The T-N removal efficiencies were 96% or higher at C/N ratios of $10{\sim}5$, but decreased to 83% and 81%, respectively at the C/N ratios of 3 and 2.8. At the C/N ratios of 2.6 and 2, the effluent quality deteriorated due to ammonia toxicity. The fraction of nitrifying microorganism in the reactors increased from 10% to 20% as the C/N ratio decreased from 5 to 2.6. Alkalinity consumed were $3.12{\sim}3.49\;g$ alkalinity/g T-N removed at the C/N ratios of $10{\sim}5$, which are lower than the theoretical value of 3.57. However, the ratio increased to 4.63 and 4.87 g alkalinity/g T-N removed, respectively at the C/N ratios of 3 and 2.8.

High Strength Slaughter Wastewater Treatment in a Novel Combined System of Hybrid-Rotating Biological Contactor and Biological Aerated Filter (Hybrid-RBC와 BAF의 조합공정을 이용한 고농도 도축폐수의 처리 특성)

  • Jung, Chan-Il;Ahn, Jo-Hwan;Bae, Woo-Keun;Kim, Seung-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.77-84
    • /
    • 2011
  • This study was conducted to develop a novel combined system of a hybrid rotating biological contactor (RBC) process that was composed of an attached- and suspended- biomass reactor, followed by a settler and a biological aerated filter (BAF) column to treat a high strength slaughter wastewater. Long term influences of organic and nitrogen loading rates were investigated to see how the combined system worked in terms of the removal efficiency. A synthetic wastewater containing a pork cutlet steak source (commercially available) and swine blood was used to feed the combined system. The hybrid RBC process showed excellent removals: about 95% for soluble COD and 85% for ammonium nitrogen. However, the unsettled solids seriously deteriorated the removal efficiency of total COD (TCOD) and total nitrogen (TN) in the RBC process. A significant fraction of the TCOD and suspended solids (SS) was further removed in the BAF column although the effluent quality was still unsatisfactory, giving TCOD 300 mg/L, SS 180 mg/L and TN 59 mg/L. An addition of polyaluminium chloride into the RBC effluent improved the performance of the settler and BAF, producing an excellent quality of final effluent; TCOD 16.5 mg/L, SS 0 mg/L, TN 55.5 mg/L, TP 1.3 mg/L. Therefore, it was confirmed that the combined system of hybrid RBC and BAF could treat a high strength slaughter wastewater excellently.

Degradation of Triclosan by the Photolysis, the Fenton, and the Hybrid Reaction with Fe$^{2+}$ and UV : A Comparative Study (광반응, 펜톤, 그리고 Fe$^{2+}$와 UV의 조합반응을 이용한 Triclosan의 분해 : 공정 비교 연구)

  • Son, Hyun-Seok;Zoh, Kyung-Duk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.5
    • /
    • pp.517-523
    • /
    • 2008
  • The degradation mechanism of Triclosan(TCS), which is a potent broad-spectrum antimicrobial agent and has been considered as an emerging pollutant, was investigated in the Fenton and the hybrid reaction with Fe$^{2+}$ and UV-C. The results show that the Fe$^{2+}$ is oxidized to 30% by $H_2O_2$, 28% by UV-C, and 15% by UV-A for 10 min. The degradation rate of TCS for beginning time(10 min) was higher in UV-C only reaction than that in hybrid reaction, which of the order was inverted according to the lapse of reaction time. The effect of methanol was the greatest in Fenton reaction, in which the degradation rate of TCS decreased from 90% to 5% by the addition of methanol. Chloride, ionic intermediate, was produced to 77% for 150 min of hybrid reaction(Fe$^{2+}$ + UV-C), which was the greatest. In case with methanol, the generation rate of chloride for 15 min was ignorable in all reactions($\leq$2%) but the hybrid reaction with Fe$^{2+}$ and UV-C(12%). Additionally, the removal rate of TOC in each reaction was estimated as the followed orders; Fe$^{2+}$ + UV-C > Fe$^{2+}$ + $H_2O_2$ > Fe$^{2+}$ + UV-A > UV-C > UV-A. However, the Fenton reaction was almost stopped after 90 min because the reaction between Fe$^{2+}$ and $H_2O_2$ cannot be kept on without adding the oxidant. The phenomena was not observed in the hybrid reaction. In view of generating chloride, the reductive degradation of TCS may be in the hybrid reaction with Fe$^{2+}$ and UV-C, which is favorable to mineralize halogenated organic compounds such as TCS. Consequently, the hybrid process with Fe$^{2+}$ and UV-C may be considered as the alternative treatment method for TCS.

The Application of Aluminum Coagulant for the Improvement of Water Quality in Three Recreational Ponds (알루미늄 응집제를 사용한 호수수질 개선 사례 연구)

  • Kang, Phil-Goo;Kim, Bom-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.4 s.105
    • /
    • pp.447-454
    • /
    • 2003
  • Aluminum coagulant was applied to two eutrophic lakes (Lake Sukchon, in Seoul, and a pond on the campus of Kangwon National University), to precipitate suspended particles and phosphate from the water column. Aluminum sulfate (alum) was used for seven treatments and polyaluminum chloride (PAC) was used for one treatment. The effect of treatment varied depending on the dose of alumium coagulant. Particles and phosphate were completely precipitated from the water column with a dose of 10.0 mgAl/l. Partial removal was observed at doses of 3.3 and 1.8 mgAl/l, but not at 0.45 mgAl/l. Therefore, coagulant should be applied at a dose over the threshold in order to remove particles effectively, which seems to be between 1.8 and 10.0 mgAl/l. The length of treatment effect was determined by new inputs of nutrients and particles from external sources. Renewal of pond water by stream water caused recovery of algal growth in Lake Sukchon, and rainfall runoff and ground water pumping caused a return of turbid water in the campus pond. During treatment there was no sign of decreasing pH, or harmful effects on fish or mussels. Aluminum coagulant may be an economically feasible alternative for water quality improvement when the external control of pollutant sources is difficult. However, repeated application is required when there is a renewal of lake water or new input of nutrients.

Lead Biosorption by Alginate Beads Immobilizing Aspergillus niger (Aspergillus niger를 고정화한 Alginate Bead에 의한 납 흡착)

  • Bang, Byung-Ho
    • Applied Biological Chemistry
    • /
    • v.44 no.3
    • /
    • pp.185-190
    • /
    • 2001
  • Alginate, a well-known biopolymer, is universally applied for immobilization of microbial cells. Biosorption characteristics of lead by waste biomass of immobilized A. niger beads, used in fermentation industries to produce citric acid, were studied. The immobilized A. niger beads, prepared via capillary extrusion method using calcium chloride, were applied in the removal of lead. Pb uptake was the highest in A. niger beads cells grown for 3 days with medium producing citric acid (12% sucrose, 0.5% $NH_4NO_3$, 0.1% $KH_2PO_4$, and 0.025% $MgSO_4$). Lead uptake by the immobilized A. niger beads and free A. niger mycellia beads increased sharply with time. However, while uptake by the immobilized A. niger beads continued to increase slowly, that by free A. niger mycellia beads stopped after 30 min. The optimum pH and temperature of lead uptake were found to be 6 and $35^{\circ}C$, respectively. The maximum uptake of lead was achieved with $50{\sim}100$ beads and 50 ml lead solution in a 250-ml Erlenmeyer flask, while, at over 100 beads, uptake of the lead decreased. The order of biosorption capacity for heavy metals was Pb>Cu>Cd. Pb uptake capacity of the immobilized A. niger beads treated with 0.1 M $CaCI_2$, 0.1 M NaOH, and 0.1 M KOH decreased compared to the untreated beads. On testing the desorption of Pb from the immobilized A. niger beads, re-uptake of Pb was found possible after desorption of the binding metal with 0.1 M HCI.

  • PDF

Removal of Color and non-biodegradable organic matter from biologically treated effluent by coagulation. (응집에 의한 생물학적 처리수의 색도 및 난분해성 유기물 제거)

  • Seo, Tae-Gyeong;Park, Sang-Min;Park, No-Baek;Jeon, Hang-Bae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.859-863
    • /
    • 2008
  • 축산폐수, 침출수 등의 고농도 폐수를 생물학적으로 처리할 경우 최종 방류수는 강한 색도를 띠며 고분자량의 유기물질을 다량 함유한다. 이는 생물학적으로 분해하기 어려운 유기성 복합체와 생화학적 반응에 의한 중간생성물로 색도를 띠는 천연유기물질(NOM)을 포함한다. 생물학적 처리수의 색도는 심미적인 불안감, 방류수역의 수질오염 및 공중보건상의 잠재적 위해성을 갖는다. 또한, 수자원 이용측면에서 정수처리공정에서의 약품투입량 증가와 특히, 소독부산물 생성이라는 잠재적 문제점이 뒤따른다. 따라서 이러한 문제점을 해소하기 위한 생물학적 2차 처리수의 후속처리가 요구되며, 실제로 난분해성 유기물과 색도를 제거하기 위한 흡착, 막 분리, 고급산화(AOP) 및 화학적 응집 등의 물리-화학적 공정에 대한 연구가 수행되어왔다. 특히, 화학적 응집은 무기응집제 또는 고분자중합체(Polymer)를 이용하여 콜로이드성 입자와 색도를 띠는 난분해성 유기물을 전기적 불안정화를 유도함으로서 흡착 및 응집과정을 통해 제거하는 공정으로 많은 연구자들에 의해 연구되어왔다. 그러나 난분해성 유기물과 색도제거는 대상원수의 성상과 화학적 특성 등에 따라 각각의 제거효율과 최적 운전조건이 상이하게 나타난다. 화학적 응집공정은 비교적 높은 제거효율을 보이지만, 운전 및 유지관리의 기술적 어려움, 경제적 비효율성 등으로 인하여 적용에 어려움을 겪고 있는 실정이다. 본 논문에서는 생물학적 혐기-호기성 공정에서 방류되는 축산폐수의 2차 처리수를 대상으로 화학적 응집에 의한 색도 및 난분해성 유기물의 제거거동을 고찰하였다. 대상 처리수의 $TCOD_{Cr}$ 농도는 평균 410 mg/L인 반면, $BOD_5$는 7-15 mg/L 범위로 난분해성 유기물을 다량 함유하고 있음을 알 수 있었다. 이에 황산알루미늄(Aluminium sulfate; $Al_2(SO_4){\cdot}14H_2O$)과 염화철(ferric chloride)의 무기응집제를 이용하여 자 테스트(jar test)를 수행한 결과, 동일한 응집제 주입량에서 염화철의 유기물 제거 효율이 높은 것으로 나타났다. 황산알루미늄과 염화철의 경우 각각의 응집제 주입율 5.85mM에서 89%, 7.03mM에서 97.5%의 최대 유기물 제거효율을 보여주었으며, 이 때 최종 pH는 4.0-5.6 범위이었다. 한편, 대상 원수 내의 콜로이드성 입자 또는 용존성 유기물의 작용기(functional group)는 일반적으로 음으로 하전 되어 있어 응집에 의해 잘 제거되지 않는 특성을 가지고 있다. 따라서 과량의 응집제를 주입하여 다가의 양이온성 금속염을 흡착시켜 전기적으로 중화시키고, 생성된 침전성 수화물 내에 포획 또는 여과시켜 제거하게 된다. 이 때, 금속염 수화종의 전하밀도가 응집효율에 영향을 주는 것으로 알려져 있는데, 다가의 양이온은 전기적 이중층(Double layer) 압축에 의한 불안정화를 향상시킬 수 있기 때문에다. 또한, 2가 금속염은 색도유발물질과 흡착하여 humate 또는 fulvate 등의 착화합물(complex)을 형성시켜 응집효율을 향상시킬 수 있다. 따라서 본 연구에서는 생물학적 2차 처리수의 화학적 응집처리에 있어서 알루미늄염 등의 다가이온 첨가가 응집에 미치는 영향을 관찰하고, 후속되는 플록형성 및 침전공정에 의한 제거효율을 비교, 평가함으로써 2차 처리수로부터 난분해성 유기물과 색도를 보다 효과적이고 경제적으로 제거할 수 있는 최적인자를 도출하고자 하였다.

  • PDF