• 제목/요약/키워드: Chloride Ion Penetration

검색결과 291건 처리시간 0.033초

콘크리트 표면도장에 의한 내구성증진 효과 (Effect of Concrete Coating Materials for the Improvement of Concrete Durability)

  • 문한영;김성수;안태송;김홍삼
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.433-436
    • /
    • 1999
  • Long-term durability of the reinforced concrete structures exposed to marine environment deteriorates seriously by the attack of the chloride ion from see water results in corrosion of steel reinforcement in concrete. Their coating effect is aluminum oxide-isocyanate-based coating material, resistance of chloride penetration, carbonation and freezing and thawing resistance were compared to acryl-based coating material and sealer type o waterproofing material. Aluminum oxide-isocyante-based and acryl-based coating material show higher resistance to chloride penetration and carbonation than the sealer type do waterproofing material and aluminum oxide-isocyanate-based coating resist about 99% of chloride penetration. Resultants to the accelerated test for freezing and thawing, coating concrete show higher resistance than non-coating concrete, respectively.

  • PDF

메타카올린 및 실리카퓸의 혼입이 고강도 콘크리트의 압축강도와 염소이온 투과에 미치는 영향에 관한 통계적 가설검증 (The Statistical Hypothesis Verification to Influence of Addition of Metakaolin and Silica Fume on Compressive Strength and Chloride Ion Penetration of High Strength Concrete)

  • 민정욱
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.215-225
    • /
    • 2011
  • 메타카올린은 고령토나 카올린으로 알려진 카올린 광물의 풍화물로, 도자기 산업에 주로 사용되는 원료로, 일반적으로 메타카올린의 입자 크기는 시멘트보다는 작지만, 마이크로 실리카퓸보다는 크다. 본 연구에서는 콘크리트용 혼화재로 메타카올린을 사용한 콘크리트의 압축강도와 염소이온 투과저항 특성에 관한 영향에 관해 조사하였다. 메타카올린과 실리카퓸의 혼입률이 압축강도와 염소이온 투과저항에 주는 영향을 비교하기 위해 물-결합재비를 30%로 고정하고 각각 0, 5, 10, 15, 20%인 배합수준을 설정하여 비교하였다. 연구결과 메타카올린을 혼입한 콘크리트는 실리카퓸을 혼입한 콘크리트와 유사한 강도특성을 보였지만, 염소이온 투과저항성은 다소 불리한 것으로 나타났다. 따라서, 강도와 염소이온 투과저항 성능을 동시에 만족하기 위한 메타카올린의 혼입률은 10% 정도인 것으로 나타났다.

콘크리트의 염소이온 확산특성에 미치는 양생조건의 영향 (Effect of Curing Conditions on the Characteristics of Chloride Ion Diffusion in Concrete)

  • 임병탁;배수호;정영수;심은철;하재담
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.715-720
    • /
    • 2003
  • The chief factors for the penetration and diffusion of chloride ions in concrete are water-cement ratio(W/C), aging, curing conditions, chloride ions concentration of given environment., wet and dry conditions and etc. In this study, of these factors effect of curing conditions such as standard and outdoor curing on the characteristics of chloride ions diffusion in concrete were researched when environmental factors for the penetration and diffusion of chloride ions were constant. For this purpose, the voltages passing through the diffusion cell were measured by using accelerated test method using potential difference, and then diffusion coefficients of chloride ions by using Andrade's method were estimated for 44%, 49.5% and 60% of w/c, respectively. As a result., according to curing conditions correlation among diffusion coefficients of chloride ions, W/C and aging were concluded through multiple regression model.

  • PDF

염화물 고정화를 고려한 철근 콘크리트 구조물의 내구수명 예측 (Service Life Prediction of R.C. Structures Considering Chloride Binding)

  • 이창수;박종혁;김영욱
    • 한국방재학회 논문집
    • /
    • 제10권1호
    • /
    • pp.15-22
    • /
    • 2010
  • 자연환경 중 다양한 형태로 존재하는 염화물은 콘크리트 구조물의 철근 부식을 야기하며 이에 따른 심각한 내구성 저하와 함께 구조물의 수명을 감소시킨다. 현재 콘크리트 중의 염화물 침투 특성을 규명하기위한 연구는 해안가 장기 폭로 시험과 전기화학적 촉진 시험에 의한 확산계수 평가 등에 의해 지속적인 발전을 이루어왔으나 콘크리트의 배합, 수화도, 고정화능력, 공극률의 재료적 특성을 고려한 이성적이며 포괄적인 염화물 침투 모델에 관한 연구는 부족한 실정이다. 따라서 본 연구에서는 실내 염화물 침지 실험을 통해 콘크리트의 염화물 고정화 특성을 파악하고 이를 고려한 염화물 침투 모델로서 비정상상태의 염화물 침투 해석과 함께 해양침지환경하의 철근콘크리트 구조물의 내구수명 예측을 시도하였으며 SHRP 기준과 20~40%의 내구수명의 차이를 보였다.

고농도 황산염 이온이 함께 존재하는 경우의 염소이온 침투특성에 관한 실험 연구 (Experimental Study on Chloride Penetration into Concrete under Combined Exposure Conditions of Chlorides and High Concentrated Sulfates)

  • 오병환;정상화;강의영;김지상
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.173-182
    • /
    • 2003
  • 최근 영종도신공항, 서해대교, 원자력발전소 등 열악한 환경에 노출되는 구조물들의 건설이 증가되면서 구조물의 내구성 확보에 관한 관심이 커지고 있는 실정이다. 특히 철근부식과 관련하여 콘크리트 구조물의 성능저하에 가장 큰 영향을 미치는 염해에 대한 연구가 활발히 진행되고 있다. 그러나 그 동안 주로 염소이온 단일열화에 대한 연구는 많았으나 염소이온과 황산염 등이 복합으로 작용하는 경우 등 복합열화에 대한 연구는 찾아보기 어려운 실정이다. 따라서, 본 연구에서는 이러한 단일염소이온 만이 아니라 염소이온과 황산염 이온이 복합된 환경하에서 콘크리트 구조물의 성능저하 현상을 규명하고 이들의 상호영향을 연구하는데 목적을 두고 두 가지 경우에 대한 실험을 수행하였다. 단일 염소이온이 존재하는 경우보다 황산염 이온이 동시에 작용하는 경우 염소이온 침투량이 증가하였으며, 모든 조건에서 표면염소이온의 농도는 시간에 따라 증가하고 반면에 확산계수는 시간에 따라 감소하는 경향을 나타냈다. 또한 플라이애시를 사용한 경우 모든 배합과 노출환경에서 확산계수가 줄어드는 것으로 나타났다. 본 연구에서는 실험결과에 따라 표면염소이온의 농도와 확산계수의 시간의존성을 예측하는 식을 제시하였으며, 이들의 영향을 고려한 염소이온 침투 예측식을 제시하였다. 본 연구의 결과는 해수 등과 같이 염소이온 및 황산염 이온이 복합 작용하는 경우 장기적인 염소이온 침투량을 예측하는 데 참고자료가 될 것으로 사료되며, 정확한 예측을 위해서는 이를 통한 진전된 복합환경하의 연구가 필요하다.

마감재가 시공된 콘크리트에 있어서 염화물 확산계수 산정 방법 (A Calculating Method of Chloride Ion Migration Coefficient in Concrete Coated Finish Materials)

  • 조한규;안재철;강병희;오상균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.31-32
    • /
    • 2011
  • The purpose of this study is to investigate the amount of chloride penetration into concrete finishing materials. Chloride ion migration test was used rapid infiltration method proposed by 'NT-Build 492'. The kind of coated finishing material is 'None-finished(N)', 'Cement Mortal(M)', 'Water based paint(P)', 'Bone-Tile(B)', 'Repair Mortal(R1)' in this paper.

  • PDF

하이볼륨 플라이애시 콘크리트의 철근부식 및 염소이온 확산 특성 (Characteristics for Reinforcement Corrosion and Chloride Ion Diffusion of High Volume Fly Ash Concrete)

  • 권순오;배수호;이현진;정상화
    • 한국건설순환자원학회논문집
    • /
    • 제2권1호
    • /
    • pp.34-39
    • /
    • 2014
  • 이 연구의 목적은 하이볼륨 플라이애시(HVFA) 콘크리트의 강도수준 및 플라이애시의 혼입률별로 콘크리트 내의 철근부식 및 염소이온 침투 저항성을 평가하는 것이다. 이를 위하여 물-결합재비 및 플라이애시 혼입률에 따라 철근 상부를 노출시킨 원주형 공시체와 통상적인 원주형 공시체를 제작하였으며, 이들 각각에 대해 압축강도 및 염소이온 침투 저항성 시험과 전기화학적 방법에 의한 철근부식 촉진시험을 수행하였다. 실험 결과, 대체적으로 플라이애시 혼입률이 많을수록 HVFA 콘크리트의 압축강도는 감소하였으나, 철근부식 및 염소이온 침투 저항성은 크게 개선되는 것으로 나타났다.

Moving Mesh Technique을 이용한 2차원 염해 침투 예측 모델의 개발 (Development of Two Dimensional Chloride Ion Penetration Model Using Moving Mesh Technique)

  • 최원;김한중
    • 한국농공학회논문집
    • /
    • 제57권6호
    • /
    • pp.1-7
    • /
    • 2015
  • Most of chloride diffusion models based on finite difference method (FDM) could not express the diffusion in horizontal direction at each elevation. To overcome these weakness, two dimensional chloride ion penetration model based on finite element method (FEM) to be able to combine various multi-physics simultaneously was suggested by introducing moving mesh technique. To avoid the generation of mesh being able to be distorted depending on the relative movement of water level to static concrete, a rectangular type of mesh was intentionally adopted and the total number of meshes was empirically selected. The simulated results showed that the contents of surface chloride decreased following to the increase of elevation in the top part of low sea level, whereas there were no changes in the bottom part of low level. In the DuraCrete model, the diffusion coefficient of splashed zone is generally smaller than submerged zone, whereas the trend of Life365 model is reverse. Therefore, it could be understood that the developed model using moving mesh technique effectively reflects $DuraCrete^{TM}$ model rather than $Life365^{TM}$ model. In the future, the model will be easily expanded to be combined with various multi-physics models considering water evaporation, heat of hydration, irradiation effect of sun and so on because it is based on FEM.

LIBS와 이온교환막을 활용한 모르타르 단면 침투 황산염과 염화물 분석 (A Comparative Study of Sulfate and Chloride Intrusion in Mortar Sections: An Approach Using Laser Induced Breakdown Spectroscopy and Ion Exchange Membrane)

  • 박원준
    • 한국건축시공학회지
    • /
    • 제23권3호
    • /
    • pp.221-229
    • /
    • 2023
  • 본 연구에서는 모르타르 내 침투 염화물과 황산염 분석을 단면 깊이별 용출액을 대상으로 음이온교환막(AEM)과 LIBS를 활용하여 수행하였다. 염화물(황산염) 농도별로 침지한 모르타르를 대상으로 IC 분석과 LIBS 분석을 동시에 진행하였다. 실험 결과로, Cl(837.59nm) 및 S(921.3nm)의 파장에서 AEM은 동일 침투 농도에서 paper substrate보다 높은 LIBS 강도가 측정되었고, LIBS 강도와 Cl농도 사이의 높은 상관관계가 확인되었다. 동일 깊이 IC 분석 농도 결과와 비교할 때, AEM을 활용하여 높은 강도를 얻을 수 있었다. AEM을 통해 저농도 구간의 LIBS 강도 향상과 오차 저감을 확인하였으나, S(921.3nm)의 경우는 저농도 구간에 대한 LIBS 신호 감도의 향상이 향후 필요할 것으로 보인다.

우레탄계와 아크릴계 도막 방수재가 도포된 바탕 모르타르의 염해 저항성 평가 (Salt damage resistance of mortar substrate coated by the urethane and acrylic waterproofing membranes)

  • 이준;미야우치 히로유키;구경모;최경철;미야우치 카오리;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.329-331
    • /
    • 2013
  • The salt damage resistance of waterproofing membrane was evaluated on the cracked mortar substrate. The types of specimens are urethane, acrylic waterproofing membrane, and no coating mortar substrate. After these specimens were cured by water curing for 4 weeks, they were cured by atmospheric curing at 20±2Co for 8 weeks. The salt water immersion test was carried out by following KS F 2737, and the penetration depth of chloride ion into substrate was measured in 1, 4, 8, and 13 weeks. As a result, in the case of non coating specimen, the chloride ion penetrated within one week. In the coated specimens, a regardless of the membrane type, the chloride ion did not penetrate during 13 weeks-tests on condition that the cracked width of substrate is less than 0.3mm. Also, the penetration speeds of the coated specimens were lower than that of non coating specimen. Therefore, our results reached a conclusion that waterproofing membrane has high salt damage resistance.

  • PDF