• Title/Summary/Keyword: Chloride Ion

Search Result 1,128, Processing Time 0.023 seconds

Prediction of chloride penetration into hardening concrete (경화중 콘크리트의 염해 침투성능에 관한 연구)

  • Fan, Wei-Jie;Wang, Xiao-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.50-51
    • /
    • 2015
  • In marine and coastal environments, penetration of chloride ions is one of the main mechanisms causing concrete reinforcement corrosion. Currently, most of experimental investigations about submerged penetration of chloride ions are started after the four weeks standard curing of concrete. The further hydration of cement and reduction of chloride diffusivity during submerged penetration period are ignored. To overcome this weak point, this paper presents a numerical procedure to analyze simultaneously cement hydration reaction and chloride ion penetration process. First, using a cement hydration model, degree of hydration and phase volume fractions of hardening concrete are determined. Second, the dependences of chloride diffusivity and chloride binding capacity on age of concrete are clarified. Third, chloride profiles in hardening concrete are calculated. The proposed numerical procedure is verified by using chloride penetration test results of concrete with different mixing proportions.

  • PDF

Effect of Metal Ions on the Oxidation of Soybean Oil and Its Fried Noodle (각종(各種) 금속(金屬) 이온이 대두유(大豆油)및 그 튀김 면(麵)의 산패(酸敗)에 미치는 영향에 대(對)하여)

  • Choe, Myen;Kim, Tae-Woong;Lee, Yang-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.157-164
    • /
    • 1977
  • In the present study, the proxidant effect of ferrous and cupric chlorides which added to soybean oil and its fried noodle in the same concentration of the city water and the physically refined underground water were determined. As the inhibitor of metal proxidation, BHA and citric acid which are used widely in oil industry as antioxidants were compared. In both cases of soybean oil and its fried noodle, the addition of cupric chloride and ferrous chloride showed prominent proxidant effect. Especially, cupric chloride marked more proxidant effect than ferrous chloride by 3 to 6 times with the elapse of time. In the inhibition activity of metal proxidation, citric acid was more effective than BHA. The 1ppm of Cu +0.01% of citric acid treated soybean oil showed less proxidant effect than the control at the later stage. The inhibition activity of citric acid on $Fe^{++}$ in soybean oil was more effective than $Cu^{++}$ in soybean oil.

  • PDF

SEASONAL VARIATIONS OF CHLORIDE, CALCIUM AND MAGNESIUM ION CONCENTRATIONS IN NAGDONG RIVER WATER AT MUL GEUM INTAKE STATION OF BUSAN CITY WATER FROM MARCH 1974 TO MARCH 1975 (낙동강 물금구취수장 상수도원수의 염화이온 칼슘 마그네슘 농도의 연간변동에 대하여(1974년-1975년))

  • WON Jong Hun;YANG Han Serb
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.2
    • /
    • pp.103-109
    • /
    • 1978
  • The contents of chloride ion, calcium and magnesium in Nagdong River water were determined at Mul Geum where the intake station for Busan city water is located. Samples were taken in spring and neap tides of every month from March 1914 to March 1975. The range and mean values of the chloride ion and total hardness were 5.12-39.4ppm, 11.9ppm; 27.8-70.8ppm, 49.5ppm respectively from March 1974 to January 1975. The highest values were found in the period of the widest tidal range of a year, from February 9 to March 9 in 1975, such as tile ranges and means of chloride ion and total hardness were 10.8-876 ppm, 89.8ppm : 48.0-407ppm, 89.9ppm. On several days of this period those concentrations were over the criteria of drinking water, 150 ppm in chloride and 300ppm in total hardness. Chloride ion concentration was increased with increasing of water level of the Nagdong River at Mul Geum. The patterns of the variations of tide level were similar to that of water level with delay of 2.5 hours in spring tides and 3 hours in neap tides.

  • PDF

Evaluation of Exposure Indicators for Plants by Silicon Tetrachloride Release (사염화규소 누출사고지점 주변 식물에 대한 노출지표 평가)

  • Park, Jae-Seon;Kim, Jee-Young;Kim, Myeong-Ock;Park, Hyun-Woo;Chung, Hyen-Mi;Choi, Jong-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.4
    • /
    • pp.288-292
    • /
    • 2017
  • BACKGROUND: Silicon tetrachloride reacts with moisture in the atmosphere to generate hydrogen chloride, which affects the environment. Since silicon tetrachloride and its by-products are dispersed in the atmosphere in a short time after the silicon tetrachloride release into the atmosphere, it is difficult to directly assess the extent of environmental impact. In the present study, the exposure test of silicon tetrachloride or hydrogen chloride was examined in order to establish the criterion of the range affected by the silicon tetrachloride release, and the actual crops in the area exposed to silicon tetrachloride leakage were analyzed. METHODS AND RESULTS: For the experiment of exposure to silicon tetrachloride or hydrogen chloride, the leaves of red-pepper and corn were used in glass sealed containers. In the actual accident area, 59 samples from 10 different kinds of crops were collected. The pretreatment of the sample was performed by freezing and grinding, and then extracted using distilled water. The pH and concentration of chloride ($Cl^-$) ion of the extracted solution were measured using pH meter and ion chromatograph, respectively. CONCLUSION: Exposure to silicon tetrachloride caused visible damage, increasing the concentration of chloride ion, and decreasing the pH as well as hydrochloric acid. In the actual crops of the affected area, the tendency was the same as the result of the laboratory test, and the range of influence could be estimated through the concentration of $Cl^-$ ion over 2,000 mg/kg, and the correlation evaluation between the concentration of $Cl^-$ and pH. Therefore, the concentration of $Cl^-$ ion and the correlation between $Cl^-$ and pH would be considered as the factors to estimate the influence range of silicon tetrachloride release.

A Study on the Evaluation of the Water-soluble Chloride Content and Free-chloride Content in Blast Furnace Slag Cement Pastes (고로 슬래그 시멘트 페이스트 내 자유염화물량과 물가용성 염화물량 평가에 관한 연구)

  • Jo, Young-Kug;So, Seung-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.4
    • /
    • pp.95-101
    • /
    • 2004
  • The purpose of this paper is to compare free-chloride content with water-soluble chloride in blast furnace cement(BSC) paste. The content of free-chloride in cement paste measured by pore solution analysis and water-soluble chloride measured by ASTM. The result of this study are as follows: 1. The concentration of chloride ion in pore solution of BSC-solidified matrix is almost as low as 43-71% compared to that of OPC-solidified matrix containing the same chloride content in cement paste. 2. The binding capacity of specimens, OPC Pl-P5, are 93.5-77%, but the binding capacity of specimens, BSC Pl-P5 are 97.1-86.1%, which is to be as high as 2-9.1% compared to OPC containing the same chloride content. 3. In terms of water-soluble chloride content in BSC paste are 15-31.7 percent of chloride addition but free-chloride content in pore solution are 2.9-13.9 percent of chloride addition. The free-chloride content in pore solution is 19.3-43.8 percent lower for the water-soluble chloride content in cement paste.

Analysis of Cationic Surfactants in Cosmetics By Reverse phase Ion-Pair Chromatigraphy with Suressed Conductivity Detector and UV Detector

  • Jong-Keun Choi;Jae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.23 no.3
    • /
    • pp.161-167
    • /
    • 1997
  • Determination of several cationic surfactants in cosmetics has been investigated. Reverse phase ion pair chromatography was used to identify and quantitate cationic surfactants. Cationic surfactants analyzed in this experiment were cetylpyridium chloride, stearyltrimetylammonium chloride, bezalkonium chloride, benzyldicethylcetylammonium chloride, and bihenyltrimethyl ammonium chloride. The separation was achieved on a reverse phase coumn with 10mM HCl-acetonitrile eluent. In this condition, the most of cationic surfactants with exception of CPC and CTAC respectively with suppressed conductivity detector and UV detector connected in series. The calibration curves obtained by plotting the peak areas of the cationic surfactants were linear at levels ranging from 0.005 to 0.1% correlation coefficient, r=0.9988. The detection limits were 1 to 5ppm in sample solution. The average recoveries of cationic surfactants added to hair treatment cream and hair rinse in three to five experiments were 96.7 105.2% and relative standard deviations were 1.1-3.8%. The case that there were CPC and CTAC in same solution was also tested. CPC and CTAC which couldn't be separated on reverse phase column were quantitated with suppressed conductivity detector and UV detector connected in series. Recovery of CPC and CTAC were 101.6 and 89.2% respectively. The proposed method was applied to the determination of cationic surfactants in commercial hair treatment cream.

  • PDF

Assessment of some parameters of corrosion initiation prediction of reinforced concrete in marine environments

  • Moodi, Faramarz;Ramezanianpour, Aliakbar;Jahangiri, Ehsan
    • Computers and Concrete
    • /
    • v.13 no.1
    • /
    • pp.71-82
    • /
    • 2014
  • Chloride ion ingress is one of the major problems that affect the durability of concrete structures such as bridge decks, concrete pavements, and other structures exposed to harsh saline environments. Therefore, durability based design of concrete structures in severe condition has gained great significance in recent decades and various mathematical models for estimating the service life of rein-forced concrete have been proposed. In spite of comprehensive researches on the corrosion of rein-forced concrete, there are still various controversial concepts in quantitation of durability parameters such as chloride diffusion coefficient and surface chloride content. Effect of environment conditions on the durability of concrete structures is one of the most important issues. Hence, regional investigations are necessary for durability based design and evaluation of the models. Persian Gulf is one of the most aggressive regions of the world because of elevated temperature and humidity as well as high content of chloride ions in seawater. The aim of this study is evaluation of some parameters of durability of RC structures in marine environment from viewpoint of corrosion initiation. For this purpose, some experiments were carried out on the real RC structures and in laboratory. The result showed that various uncertainties in parameters of durability were existed.

Development of Two Dimensional Chloride Ion Penetration Model Using Moving Mesh Technique (Moving Mesh Technique을 이용한 2차원 염해 침투 예측 모델의 개발)

  • Choi, Won;Kim, Hanjoong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.1-7
    • /
    • 2015
  • Most of chloride diffusion models based on finite difference method (FDM) could not express the diffusion in horizontal direction at each elevation. To overcome these weakness, two dimensional chloride ion penetration model based on finite element method (FEM) to be able to combine various multi-physics simultaneously was suggested by introducing moving mesh technique. To avoid the generation of mesh being able to be distorted depending on the relative movement of water level to static concrete, a rectangular type of mesh was intentionally adopted and the total number of meshes was empirically selected. The simulated results showed that the contents of surface chloride decreased following to the increase of elevation in the top part of low sea level, whereas there were no changes in the bottom part of low level. In the DuraCrete model, the diffusion coefficient of splashed zone is generally smaller than submerged zone, whereas the trend of Life365 model is reverse. Therefore, it could be understood that the developed model using moving mesh technique effectively reflects $DuraCrete^{TM}$ model rather than $Life365^{TM}$ model. In the future, the model will be easily expanded to be combined with various multi-physics models considering water evaporation, heat of hydration, irradiation effect of sun and so on because it is based on FEM.

Effect of Benzalkonium Chloride on Percutaneous Absoption of Antisense Phosphorothioate Oligonucleotides

  • Lee, Young-Mi;Lee, Sung-Hee;Ko, Geon-Il;Kim, Jae-Baek;Sohn, Dong-Hwan
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.435-440
    • /
    • 1996
  • The effect of benzalkonium chloride on skin permeability of partially modified antisense phosphorothioate oligonucleotides (PS-ODN), which are designed as scar formation inhibitor, was investigated using Franz Diffusion Cell. When the concentration ratio of PS-ODN-quarternary ammonium salt complex is more than 1:100, the apparent partition coefficient (APC) of each complex was increased in the following order; tetraphenyl phosphonium chloride (TPP) < cetyltrimethyl ammonium bromide(CTAB) < benzalkonium chloride (BZ). The permeability of PS-ODN through the rat skin increased in the presence of BZ. The fluxs of PS-ODN with BZ were increased by addition of Pluronic F 68 or Triton X-100 to phosphate buffered saline (PBS), respectively. When the mole ratio of PS-ODN to BZ is 1:10, the fluxs penetrated of PS-ODN with BZ was greatest. The increase of the permeability in the presence of BZ might be due to the formation of lipophilic ion-pair complex between PS-ODN and BZ. By regulation of mole ratio of PS-ODN to BZ, the development of topical dosage forms using PS-ODN as scar formation inhibitor will be possible with minimal systemic exposure.

  • PDF

Corrosion Protective Method Applicable to Air Vent Connected with a Heat Transport Pipe (열수송관에 연결된 에어벤트에 적용 가능한 부식 방지 방안)

  • Min Ji Song;Gahyun Choi;Woo Cheol Kim;Soo Yeol Lee
    • Corrosion Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.115-122
    • /
    • 2023
  • This study aimed to elucidate causes of corrosion of heat transport pipes and air vents installed under a manhole of heat transport facilities and suggest effective anticorrosive measures by applying paints or adhesive tapes. It was found that air vent corrosion was attributed to corrosion under insulation caused by the inflow of water and the enrichment of chloride ions. The infiltrated water caused a hydrolysis of polyurethane foam (PUF) insulation by concentrating chloride ions at the interface between a pipe and the PUF. As insulator deteriorated, more chloride ions were eluted as confirmed by ion chromatograph (IC) analysis. As an effective method to prevent air vent corrosion, different types of paints and adhesive tapes with higher corrosion resistance on chloride ions were applied and environmental resistance tests were performed with those samples. Based on environmental test results of samples exposed to 10% HCl solution, it was revealed that a wax tape was the most adequate from a viewpoint of stability at operating condition, environmental resistance, surface treatment, and field applicability.