• 제목/요약/키워드: Chiral chromatography

검색결과 115건 처리시간 0.023초

Resolution of Salbutamol Enantiomers in Human Urine by Reversed-Phase High Performance Liquid Chromatography after Derivatization with 2,3,4,6-Tetra-O-acetyl-${\beta}$-D-glucopyranosyl Isothiocyanate

  • Kim, Kyeong-Ho;Kim, Tae-Kyun
    • Archives of Pharmacal Research
    • /
    • 제21권2호
    • /
    • pp.217-222
    • /
    • 1998
  • A stereospecific HPLC method has been developed for the resolution of the enantiomers of salbutamol in human urine. After solid-phase extraction and derivatization with 2,3,4,6-tetra-O-acetyl-$\beta$-D-glucopyranosyl isothiocyanate, the diastereomeric derivatives were resolved (Rs=1.83) on $5{\mu}m$ octadecylsilan column using 35% acetonitrile in 0.05M ammonium acetate buffer (pH=6) as a mobile phase with electrochemical detection. The diastereomeric derivatives were formed within 30 min. The detection limit of each enantiomer was 20 ng/ml (S/N=3).

  • PDF

Chiral Purity Test of Metoprolol Enantiomer After Derivatization with (-)-Menthyl Chloroformate by Reversed-Phase High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Choi, Pok-Wha;Hong, Seon-Pyo;Kim, Hyun-Ju
    • Archives of Pharmacal Research
    • /
    • 제22권6호
    • /
    • pp.614-618
    • /
    • 1999
  • A reversed-phase high-performace liquid chromatographic method was developed to determine the optical purity of metoprolol enantiomers. The enantiomers were converted to diastereomeric derivatives using (-)-menthyl chloroformate reagent. Separation of the enantiomers as diastereomers was achieved by reversed-phase HPLC within 30 min using Inertsil C8 column. This method allowed determination of 0.05% of either enantiomer in the presence of its stereoisomer and method validation showed adequate linearity over the required range. Owing to the reaction condition during the derivatization with (-)-menthyl chloroformate, the possibility of racemization had to be established. Different ratios of (S)-(-)-metoprolol and (R)-(+)-metoprolol were prepared. Enantiomeric separation of these mixtures took place on a chiralcel OD column or, after derivatization with (-)-menthyl chloroformate, on a C8 column. The results form the these two independent separation systems were compared with trace racemization and were in very good agreement. No racemization was found during the experiment.

  • PDF

Separation of D and L Amino Acids by High-Performance Liquid Chromatography

  • Lee, Sun-Haing;Ryu, Jae-Wook;Park ,Kyoung-Sug
    • Bulletin of the Korean Chemical Society
    • /
    • 제7권1호
    • /
    • pp.45-50
    • /
    • 1986
  • Separation of optical isomers of some derivatives of amino acids by reversed-phase HPLC has been accomplished by adding a chelate of an optically active amino acid to copper(Ⅱ) to the mobile phase. Cu(Ⅱ) complexes of L-proline and L-hydroxyproline in the mobile phase showed different degrees of separation. Optical isomers of DNS derivatives of amino acids are selectively separated, but those of several other derivatives are not at all. The kinds of buffer agents, the pH, and the concentrations of acetonitrile and the Cu(Ⅱ) ligand all affect the separations. The elution behavior between D and L DNS-amino acids appears to depend on the alkyl side chain of the amino acids. A chromatographic mechanism is proposed that is based on a stereospecificity of the formation of ternary complexes by the D, L-DNS-amino acids and the chiral additive associated with the stationary phase. The steric effects of the ligand exchange reactions are related with the feasibility of cis and/or trans attack of the amino acids to the binary chiral chelate retained on the stationary phase.

Effective determination of nicotine enantiomers from e-liquids and biological fluids by high performance liquid chromatography (HPLC) using dispersive liquid-liquid microextraction (DLLME)

  • Song, Seunghoon;Myung, Seung-Woon
    • 분석과학
    • /
    • 제34권4호
    • /
    • pp.180-190
    • /
    • 2021
  • This study compared the efficacy of chiral GC and chiral HPLC for the analysis of nicotine. To develop a suitable dispersive liquid-liquid microextraction (DLLME) method, the following parameters were optimized: pH, extraction solvent, dispersive solvent, type and quantity of salt, and laboratory temperature. The validation of the method was carried out by the established HPLC method. The LODs were 0.11 ㎍/mL and 0.17 ㎍/mL for the (S)- and (R)- enantiomers, respectively. The LOQs were 0.30 ㎍/mL and 0.44 ㎍/mL, respectively. The optimal calibration range was between 0.30-18 ㎍/mL and 0.44-4.40 ㎍/mL, respectively, and the correlation coefficient (r2) was 0.9978-0.9996. The intra-day accuracy was 79.9-110.6 %, and the intra-day precision was 1.3-12.0 %. The inter-day accuracy was 87.8-108.0 %, and the inter-day precision was 4.0-12.8 %. E-liquid and biological fluids (urine and saliva) were analyzed using the established method.

Chiral Separation of Lactic Acid in Culture Media and Cells of Lactobacillus delbrueckii subsp. lactis as O-Pentafluoropropionylated (S)-(+)-3-Methyl-2-Butyl Ester by Achiral Gas Chromatography-Mass Spectrometry

  • Paik, Man-Jeong;Nguyen, Duc-Toan;Yoon, Jae-Hwan;Chae, Han-Seung;Kim, Kyoung-Rae;Lee, Gwang;Lee, Pyung-Cheon
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권7호
    • /
    • pp.2418-2422
    • /
    • 2011
  • The enantiomeric separation of lactic acid for its absolute configuration has become important task for understanding its biological origin and metabolic process involved in the formation of lactic acid. It involves the conversion of enantiomers as diastereomeric O-pentafluoropropionylated (S)-(+)-3-methyl-2-butyl ester and the direct separation by gas chromatography-mass spectrometry on a achiral capillary column. The (R)- and (S)-lactic acids were completely separated with a high resolution of 1.9. The newly developed method showed good linearity (r ${\geq}$ 0.999), precision (% relative standard deviation = 3.4-6.2), and accuracy (% relative error = -7.7-1.4) with the detection limit of 0.011 ${\mu}g/mL$. When the method was applied to determine the absolute configuration of lactic acid in Lactobacillus delbrueckii subsp. lactis 304 (LAB 304), the composition (%) of (R)-lactic acid in the cell pellet and in the culture medium were $89.0{\pm}0.1$ and $78.2{\pm}0.4$, respectively. Thus, it was verified that the present method is useful for the identification and composition test of lactic enantiomers in microorganisms.

모세관 기체 크로마토그래피에 의한 치환된 Cyclodextrin 정지상을 이용한 알코올 유도체의 키랄분리 (Chiral Separation of Derivatized Racemic Alcohols on Substitued Cyclodextrin Stationary Phases by Capillary Gas Chromatography)

  • 이선행;서영주;이광필
    • 대한화학회지
    • /
    • 제39권2호
    • /
    • pp.94-102
    • /
    • 1995
  • 모세관 기체크로마토그래피에 의한 cyclodextrin 정지상들(PH-${\beta}$-CD, DA-${\beta}$-CD, TA-${\gamma}$-CD)을 이용하여 라세미 알코올들과 그 유도체들의 분리를 연구하였다. 실험에 사용한 모든 알코올들은 trifluoro acetic anhydride, acetic anhydride, trichloro acetic anhydride를 써서 유도화하였다. 거울상체들의 분리선택성은 acylation 시약의 형태에 상당히 의존하는 것을 알았다. 알코올과 그 유도체들의 광학분활에 대한 최상의 실험조건은 용질분자들의 극성에 따라 다르다. 그리고 키랄분리에 관해서 온도, 컬럼이 극성, 수소 결합력, 알코올과 CD 정지상의 입체효과 등의 의존에 관한 연구를 행하였다. 키랄 인식 기구는 키랄 정지상의 종류에 의존하지 않고, 라세미 알코올의 유도체화에 의존하는 것으로 나타났다.

  • PDF

다당유도체를 기초로 한 키랄 컬럼에서 이동상에서의 산 또는 염기 첨가제가 아미노 알코올의 광학분리에 미치는 영향 (Effect of acid or base additive in the mobile phase on enantiomer separation of amino alcohols using polysaccharide derived chiral columns)

  • 황호;김경옥;이원재
    • 분석과학
    • /
    • 제22권4호
    • /
    • pp.313-318
    • /
    • 2009
  • 다당유도체를 기초로 하는 키랄 컬럼들을 사용하여 여러 amino alcohol의 거울상 이성질체를 산 또는 염기 등의 첨가제가 포함된 이동상에서 액체크로마토그래피로 광학분리를 수행하였다. 산 또는 염기 등의 첨가제가 각각 포함된 이동상뿐만 아니라 사용한 키랄 컬럼에 따라 광학분리된 선택성과 분리 인자가 크게 영향을 받았다. 특히 Chiralcel OD 컬럼에서 이동상에 0.1% trifluoroacetic acid를 산 첨가제로 사용했을 경우 0.1% triethylamine을 염기 첨가제로 사용했을 경우보다 머무름인자 값은 더 작게 나타났지만 광학분리의 선택성과 분리인자는 크게 증가됨을 보여주었다. 또한 Chiralcel OD 컬럼에서 이동상에 0.05% trifluoroacetic acid와 0.05% triethylamine을 함께 사용했을 때 광학분리의 선택성과 분리인자가 어느 이동상 조건보다도 가장 좋은 광학분할 결과를 보여주었다.

Chiral Separation of Salbutamol Enantiomers in Human Plasma

  • Seo, Joung-Min;Kim, Kyeong-Ho
    • Archives of Pharmacal Research
    • /
    • 제17권4호
    • /
    • pp.244-248
    • /
    • 1994
  • A stereoselective and sensitive high performance liquid chromatography using fluoresecence deterctor was examined for the determination of R(-) and S(+)-salbutamol in human plasma. Solid phase extraction method using silica as sorbent was used to extract salbutamol racemates from the plasma matrices. After fractionation and freeze-drying of the eluates containing salbutamol racemates, they were separated and quantified on a chirla stationary column. The detection limit of each enantiomer was 2 ng/ml in human plasma (S/N=3).

  • PDF