• Title/Summary/Keyword: Chip flow

Search Result 316, Processing Time 0.028 seconds

In situ Microfluidic Method for the Generation of Uniform PEG Microfiber (PEG 마이크로 섬유 제조를 위한 마이크로플루이딕 제조방법)

  • Choi, Chang-Hyung;Jung, Jae-Hoon;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.470-474
    • /
    • 2010
  • In this study, we presents a simple microfluidic approach for generating uniform Poly(ethylene glycol)(PEG) microfiber. Elongated flow pattern of monomer induced by sheath flow of immiscible oil as continuous phase is generated in Y-shape junction and in situ polymerization by UV exposure. For uniform microfiber, we investigate the optimized flow condition and draw phase diagram as function of Ca and Qd. At the region for stable elongated flow pattern, the microfiber generated in microfluidic chip is very uniform and highly reproducible. Importantly, the thickness of microfibers can be easily controlled by flow rate of continuous and disperse phase. We also demonstrate the feasibility for biological application as encapsulating FITC-BSA in PEG microfiber.

Improvement of cell area overhead for crosstalk prevention design flow by using clock shielding (크로스토크 방지 기술을 적용한 칩 제작기법에서의 클럭 넷 쉴드 처리에 의한 셀 면적 오버헤드 개선)

  • Lee, Jun-Seop;Song, Jae-Hoon;Kim, Min-Chul;Kim, Ki-Bum;Park, Sung-Ju
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.445-446
    • /
    • 2008
  • With the semiconductor industry evolving into the deep sub-micron (DSM) era, the crosstalk effects on interconnect lines of a chip have increasingly caused a major bottleneck for design closure. In this paper, we propose an effective design guide line to reduce cell area overhead without crosstalk noise violations by using crosstalk prevention flow with clock shielding.

  • PDF

Design of the floating point multiplier performing IEEE rounding and addition in parallel (IEEE 반올림과 덧셈을 동시에 수행하는 부동 소수점 곱셈 연산기 설계)

  • 박우찬;정철호
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.11
    • /
    • pp.47-55
    • /
    • 1997
  • In general, processing flow of the conventional floating-point multiplication consists of either multiplication, addition, normalization, and rounding stage of the conventional floating-point multiplier requries a high speed adder for increment, increasing the overall execution time and occuping a large amount of chip area. A floating-point multiplier performing addition and IEEE rounding in parallel is designed by using the carry select addder used in the addition stage and optimizing the operational flow based on the charcteristics of floating point multiplication operation. A hardware model for the floating point multiplier is proposed and its operational model is algebraically analyzed in this paper. The proposed floating point multiplier does not require and additional execution time nor any high spped adder for rounding operation. Thus, performance improvement and cost-effective design can be achieved by this suggested approach.

  • PDF

NUMERICAL STUDY OF CHIP COOLING ENHANCEMENT WITH EVAPORATING MIST FLOW (분무 증발을 이용한 칩 냉각 향상에 대한 수치적 연구)

  • Roh, S.E.;Kim, D.;Son, G.
    • Journal of computational fluids engineering
    • /
    • v.18 no.2
    • /
    • pp.9-16
    • /
    • 2013
  • The heat transfer enhancement of heat sink with mist flow is studied numerically by solving the conservation equations for mass, momentum and energy in the continuous and dispersed phases. A Lagrangian method is used for tracing dispersed water droplets in the heat sink and an Eulerian species transport model for air and steam mixture. The continuous and dispersed phases are interacted with the drag and evaporation source terms. The computed results show that addition of evaporating mist droplets enhances the cooling performance of heat sink significantly.

Visualization of blood sucking phenomena of a female mosquito (암 모기 흡혈과정 가시화)

  • Kim, Bo-Heum;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.114-115
    • /
    • 2007
  • As a carrier of malaria and sneak of blood, mosquitoes are regarded as an unpleasant insect. However, there are novel phenomena that happen inside a mosquito. Among them, we focused on the blood sucking function of a female mosquito. The main objective of this study was to investigate the mosquito's pumping mechanism in order to resolve the problem encountered when we inject or transport biologic fluids into a micro-chip. To analyze the pumping mechanism, we visualized the blood sucking process inside a female mosquito. Flow characteristics of blood flow in a proboscis were investigated experimentally using a micro-PIV velocity field measurement technique. The anatomical variation of head, thorax, abdomen which work as pumps and valves, was visualized using the syncrotron X-ray micro-imaging technique.

  • PDF

Flow Visualization in a new CSC micromixer (새로운 CSC micromixer 를 이용한 유동가시화)

  • Singh, Kanika;Kim, Hyun-Hoon;Min, Young-Uk;Kim, Hyung-Dong;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.63-65
    • /
    • 2007
  • The paper reports on a new type of combinatorial chaotic and serpentine micromixer. Such a new and novel micromixer is simple to fabricate and easy to use. The micromixer is characterized and visualized with the help of the Micro-LIF technique. The new micromixer will e further applied to lab-on-chip device. The mixing capabilities of this mixer is about 30-33%.

  • PDF

PIV measurements of a microfluidic elements fabricated in a plastic chip (플라스틱 미소유체요소 내부유동의 PIV 측정)

  • Lee, In-Won;Choi, Jay-Ho;Lee, In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.400-404
    • /
    • 2001
  • A micro-PIV(particle image velocimetry) measurement has been conducted to investigate flow fields in such microfluidic devices as microchannels and micronozzle. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. Velocity vector fields with a resolution of $6.7\times6.7{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent molding process. Flow fields in a variety of microchannels as well as micronozzle have been investigated.

  • PDF

A Study on the Design of Compression Air Hole in Front of Spindle for Chip Removal (주축 전면부 칩 제거를 위한 압축공기 구멍 설계에 관한 연구)

  • Kang, Dong Wi;Lee, Choon Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.3
    • /
    • pp.278-283
    • /
    • 2013
  • While Built-in Spindle is working in machining center, the tool is changed by ATC(Automatic Tool Changer) automatically. However, impurities could be stacked in front of spindle because of chips formation while machining, and positional error between spindle and tool could be generated. Compressed air holes are necessary for removal of the impurities. But, the diameter and number of compressed air hole are different for each built-in spindle in market. In this paper, flow analysis is carried out to find out the efficient figuration of the compressed air hole by using velocity and pressure distributions.

A Study on the Effects of Tool Geometry on Chip Flow (공구형상이 칩유동에 미치는 영향에 관한 연구)

  • 김경우;김우순;윤주식;채왕석;김동현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.211-215
    • /
    • 2000
  • A new methodology is presented to evaluate material properties at high strain rates and high temperatures based on orthogonal metal cutting experiments and FEM simulations. Average strain rate and average temperature found in the deformation zone are computed and flow stress data at these conditions are modified until cutting forces calculated in simulations match those determined in experiments. Material properties obtained from this method were verified by additional metal cutting simulations. Derivation from cutting forces measured in experiments was less than 10%. The feasibility of tool design using FEM simulations is also demonstrated.

  • PDF

A Study of Wire Sweep, Pre-conditioning and Paddle Shift during Encapsulation of Semiconductor Chips (반도체 칩 캡슐화 성형 공정에 있어서 와이어 스윕 및 패들 변형에 관한 연구)

  • Han, Se-Jin;Heo, Yong-Jeong;Lee, Seong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.102-110
    • /
    • 2001
  • In this paper, methods to analyze wire sweep and paddle shift during the semiconductor ship-encapsulation process have been studied. The analysis of wire sweep includes flow-field analysis in a complicated geometry, drag-force calculation for given flow of fluid, and wire-deformation calculation for given loads. The paddle-shift analysis is used to analyze the deformation of the paddle due to the pressure difference in two cavities. the analysis is done using either analytical solutions or numerical simulation. The analytical solution is used for rough but fast calculation of wire sweep. The numerical solution is used for more accurate calculation of wire-sweep. The numerical results of wire sweep show good agreements with the experimental ones.

  • PDF