• Title/Summary/Keyword: Chip fabrication

Search Result 458, Processing Time 0.028 seconds

Nanoscale Fabrication of Biomolecular Layer and Its Application to Biodevices

  • Park, Jeong-Woo;Nam, Yun-Suk;Masamichi Fujihira
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.76-85
    • /
    • 2004
  • Biodevices composed of biomolecular layer have been developed in various fields such as medical diagnosis, pharmaceutical screening, electronic device, photonic device, environmental pollution detection device, and etc. The biomolecules such as protein, DNA and pigment, and cells have been used to construct the biodevices such as biomolecular diode, biostorage device, bioelectroluminescence device, protein chip, DNA chip, and cell chip. Substantial interest has focused upon thin film fabrication or the formation of biomaterials mono- or multi-layers on the solid surfaces to construct the biodevices. Based on the development of nanotechnology, nanoscale fabrication technology for biofilm has been emerged and applied to biodevices due to the various advantages such as high density immobilization and orientation control of immoblized biomolecules. This review described the nanoscale fabrication of biomolecular film and its application to bioelectronic devices and biochips.

Fabrication of a CNT Filter for a Microdialysis Chip

  • An, Yun-Ho;Song, Si-Mon
    • Molecular & Cellular Toxicology
    • /
    • v.2 no.4
    • /
    • pp.279-284
    • /
    • 2006
  • This paper describes the fabrication methods of a carbon nanotube (CNT) filter and a microdialysis chip. A CNT filter can help perform dialysis on a microfluidic chip. In this study, a membrane type of a CNT filter is fabricated and located in a microfluidic chip. The filter plays a role of a dialysis membrane in a microfluidic chip. In the fabrication process of a CNT filter, individual CNTs are entangled each other by amide bonding that is catalyzed by 1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The chemically treated CNTs are shaped to form a CNT filter using a PDMS film-mold and vacuum filtering. Then, the CNT filter is sandwiched between PDMS substrates, and they are bonded together using a thin layer of PDMS prepolymer as adhesive. The PDMS substrates are fabricated to have a microchannel by standard photo-lithography technique.

The fabrication of micro mass flow sensor by Micro-machining Technology (Micromachining 기술을 이용한 micro mass flow sensor의 제작)

  • Eoh, Soo-Hae;Choi, Se-Gon
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.481-485
    • /
    • 1987
  • The fabrication of a micro mass flow sensor on a silicon chip by means of micro-machining technology is described on this paper. The operation of micro mass flow sensor is based on the heat transfer from a heated chip to a fluid. The temperature differences on the chip is a measure for the flow velocity in a plane parallel with the chip surface. An anisotropic etching technigue was used for the formation of the V-type groove in this fabrication. The micro mass flow sensor is made up of two main parts ; A thin glass plate embodying the connecting parts and mass flow sensor parts in silicon chip. This sensor have a very small size and a neglible dead space. Micro mass flow sensor can fabricate on silicon chip by micro machining technology too.

  • PDF

Fabrication of Hydrophobic/Hydrophilic Pattern as a Template for DNA Chip Microaray (DNA Chip Microarrays를 위한 template로서 소수성 패턴의 제작)

  • Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.472-475
    • /
    • 2004
  • Microarray-based DNA chips provide an architecture for multi-analyte sensing. In this paper, we report a new approach for DNA chip microarray fabrication. Multifunctional DNA chip microarray was made by immobilizing many kinds of biomaterials on transducers (particles). DNA chip microarray was prepared by randomly distributing a mixture of the particles on a chip pattern containing thousands of m-scale sites. The particles occupied a different sites from site to site. The particles were arranged on the chip pattern by the random fluidic self-assembly (RFSA) method, using a hydrophobic interaction for assembly.

  • PDF

Fabrication of Biochip by Hydrophobic Interaction (무작위 조립법을 이용한 바이오칩의 제작)

  • Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.404-405
    • /
    • 2006
  • Microarray-based DNA chips provide an architecture for multi-analyte sensing. In this paper, we report a new approach for DNA chip microarray fabrication. Multifunctional DNA chip microarray was made by immobilizing many kinds of biomaterials on transducers (particles). DNA chip microarray was prepared by randomly distributing a mixture of the particles on a chip pattern containing thousands of m-scale sites. The particles occupied a different sites from site to site. The particles were arranged on the chip pattern by the random fluidic self-assembly (RFSA) method, using a hydrophobic interaction for assembly.

  • PDF

Development of High-Intergrated DNA Chip Microarrays by Using Hydrophobic Interaction (소수성 상호작용을 이용한 고집적 DNA칩 마이크로어레이의 개발)

  • 김도균;최용성;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.757-760
    • /
    • 2001
  • We have used the random fluidic self-assembly (RFSA) technique based on the chip pattern of hydrophobic self-assembly layers to assemble microfabricated particles onto the chip pattern. Immobilization of DNA, fabrication of the particles and the chip pattern, arrangement of the particles on the chip pattern, and recognition of each using DNA fluorescence measurement were carried out. Establishing the walls, the arrangement stability of the particles was improved. Each DNA is able to distinguish by using the lithography process on the particles. Advantages of this method are process simplicity, wide applicability and stability. It is thought that this method can be applicable as a new fabrication technology to develop a minute integration type biosensor microarray.

  • PDF

Design and Fabrication of the System in Package for the Digital Broadcasting Receiver (디지털 방송 수신용 System in Package 설계 및 제작)

  • Kim, Jee-Gyun;Lee, Heon-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.107-112
    • /
    • 2009
  • This paper describes design and fabrication issues of the SiP(System in Package) one-chip for a portable digital broadcasting receiver. It includes RF tuner chip, demodulator chip and passive components for the receiver system. When we apply the SiP one-chip technology to the broadcasting receiver, the system board size can be reduced from $776mm^2$ to $144mm^2$. SiP one-chip has an advantage that the area reduces more 81% than separated chips. Also the sensitivity performance advances -1dBm about 36 channels in the RF weak electric field, the power consumption reduces about 2mW and the C/N keeps on the same level.

Fabrication of DNA Chip Using a Hydrophobic Template (소수성 Template를 이용한 DNA칩의 제작)

  • Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1315-1316
    • /
    • 2006
  • Microarray-based DNA chips provide an architecture for multi-analyte sensing. In this paper, we report a new approach for DNA chip microarray fabrication. Multifunctional DNA chip microarray was made by immobilizing many kinds of biomaterials on transducers (particles). DNA chip microarray was prepared by randomly distributing a mixture of the particles on a chip pattern containing thousands of m-scale sites. The particles occupied a different sites from site to site. The particles were arranged on the chip pattern by the random fluidic self-assembly (RFSA) method, using a hydrophobic interaction for assembly.

  • PDF

Fabrication of plastic CE (capillary electrophoresis) microchip by hot embossing process (핫 엠보싱 공정을 이용한 플라스틱 CE(capillary electrophoresis) 마이크로 칩의 제작)

  • Cha Nam-Goo;Park Chang-Hwa;Lim Hyun-Woo;Park Jin-Goo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1140-1144
    • /
    • 2005
  • A plastic-based CE (capillary electrophoresis) microchip was fabricated by hot embossing process. A Si mold was made by wet etching process and a PMMA wafer was cut off from 1mm thick PMMA sheet. A micro-channel structure on PMMA substrate was produced by hot embossing process using the Si mold and the PMMA wafer. A vacuum assisted thermal bonding procedure was employed to seal an imprinted PMMA wafer and a blank PMMA wafer. The results of microscopic cross sectional images showed dimensions of channels were well preserved during thermal bonding process. In our procedure, the deformation amount of bonding process was below 1%. The entire fabrication process may be very useful for plastic based microchip systems.

  • PDF

Development of DNA Chip Microarray by Using Secondary-step immobilization methods (2단계 고정화법을 이용한 DNA칩 마이크로어레이의 개발)

  • Yoon, Hee-Chan;Kim, Do-Kyun;Shin, Hoon-Kyu;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.263-265
    • /
    • 2002
  • We have used the secondary-step immobilization methods based on the chip pattern of hydrophobic self-assembly layers to assemble microfabricated particles onto the chip pattern. Immobilization of DNA, fabrication of the particles and the chip pattern, arrangement of the particles on the chip pattern, and recognition of each using DNA fluorescence measurement were carried out. Establishing the walls, the arrangement stability of the particles was improved. Each DNA is able to distinguish by using the lithography process on the particles. Advantages of this method are process simplicity, wide applicability and stability. It is thought that this method can be applicable as a new fabrication technology to develop a minute integration type biosensor microarray.

  • PDF