• Title/Summary/Keyword: Chiller System

검색결과 192건 처리시간 0.026초

LiBr/$H_2O$계 흉수기의 흡수촉진에 관한 실험적 연구 (Experimental investigation of enhanced heat and mass transfer toy LiBr/$H_2O$ absorber)

  • 설원실;권오경;윤정인
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.581-588
    • /
    • 1998
  • An experimental study of the absorption process of water vapor into Lithium Bromide solution was performed. For the purpose of development of high performance absorption chiller-heater utilizing Lithium Bromide solution as working fluid, the absorber is the most effective to improve the performance of an absorber because it requires the largest heat transfer area in an absorption chiller-heater system. This paper introduces bare tube and floral tube for the absorber of absorption chiller-heaters. floral tube has higher heat and mass transfer performance than bare tube conventionally used in absorbers and the it is expected to perform high heat and mass transfer. This paper will provide important information on the selection of absorber tubes in commercial absorption chiller -heaters.

  • PDF

흡수식 공조 시스템의 동적 모델과 시뮬레이션 (Dynamic Models and Simulation of the Absorption Air Conditioning System)

  • 한도영;이승기
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.994-1003
    • /
    • 2000
  • Control algorithms for the absorption air conditioning system may be developed by suing dynamic models of the system. The simplified effective dynamic models, which can predict the dynamic behaviors of the system, may help the development of effective control algorithms for the system. In this study, a dynamic simulation program for the absorption air conditioning system was developed. Dynamic models for an absorption chiller, a cooling tower, an air handling unit, a boiler, a three way valve, a controller, and a duct were developed and programed. Control algorithms for the absorption chiller, the cooling tower, and the air handling unit were selected, and analyzed to show the effectiveness of dynamic models. From the simulation results, it may be concluded that this simulation program may be effectively used for the development of optimal control algorithms of the absorption air conditioning system.

  • PDF

최소가동시간 제약을 고려한 심층 강화학습 기반의 다중 냉동기 운영 모델 (A Multi-chiller Operation Model Based on Deep Reinforcement Learning Considering Minimum Up-time Constraint)

  • 김종은;김관호;김재곤
    • 한국빅데이터학회지
    • /
    • 제9권1호
    • /
    • pp.153-168
    • /
    • 2024
  • 여름철 냉동기가 건물의 주 에너지 소비자로 고려됨에 따라 효율적인 냉동기 운영은 매우 중요한 문제로 고려된다. 그러나, 건물의 냉방수요가 건물 내외부 환경, 건물 재실자의 행동 등의 여러 요인에 의해 변동하고 냉동기의 가동제약조건으로 인해 현재 시점의 운영이 미래 시점의 운영에 제약을 발생시킴에 따라 건물의 냉방수요를 정확하게 만족하도록 냉동기를 운영하는 것은 어렵다. 본 연구에서는 이러한 문제를 해결하기 위해 냉동기의 최소가동시간을 고려한 심층 강화학습 기반의 다중 냉동기 운영 모델을 제안한다. 제안한 모델은 외기 정보와 냉방시스템 내부 정보로 구성된 상태에 따른 냉동기 운영 조합이 갖는 가치를 학습하고 실현 가능한 냉동기 운영 중 건물의 냉방수요와 냉동기에 의한 공급 부하 간의 차이를 최소화할 수 있는 냉동기 운영 조합을 결정한다. 냉동기의 최소가동시간 제약을 고려한 훈련 알고리즘을 적용하여 제안한 모델의 현실 적용 가능성을 높였으며 실제 국내 A대학교의 데이터를 바탕으로 실험한 결과, 제안한 다중 냉동기 운영 모델이 최소가동시간을 준수함과 동시에 건물 냉방 부하와의 차이 측면에서 A대학교의 기존 냉동기 운영 로직보다 우수한 성능을 보임을 확인하였다.

암모니아-물 흡수식 냉각기의 동적 해석 (Dynamic Analysis of an Ammonia-Water Absorption Chiller)

  • 김병주
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.990-998
    • /
    • 2004
  • Dynamic behavior of an ammonia-water absorption system was investigated numerically. Thermal-hydraulic model for a single-effect 3 RT chiller was developed by applying transient conservation equations of total mass, $NH_3$ mass, energy and momentum to each component. Transient variations of system properties and transport variables were analysed during start-up operation. Numerical analyses were performed to quantify the effects of bulk concentration and charging ratio on the system performance in terms of cooling capacity, coefficient of performance, and time constant of system. For an absorption chiller considered in the present study, optimum charging ratio and bulk concentration were to found to exist, which resulted in the maximum cooling capacity and COP. The time constant increased as the charging ratio increased, but decreased with the increase of bulk concentration.

칠러장비의 온도제어를 위한 최적 PID 제어 (Optimal PID Control for Temperature Control of Chiller Equipment)

  • 박영신;이동주
    • 산업경영시스템학회지
    • /
    • 제45권3호
    • /
    • pp.131-138
    • /
    • 2022
  • The demand for chiller equipment that keeps each machine at a constant temperature to maintain the best possible condition is growing rapidly. PID (Proportional Integral Derivation) control is a popular temperature control method. The error, which is the difference between the desired target value and the current system output value, is calculated and used as an input to the system using a proportional, integrator, and differentiator. Through such a closed-loop configuration, a desired final output value of the system can be reached using only the target value and the feedback signal. Furthermore, various temperature control methods have been devised as the control performance of various high-performance equipment becomes important. Therefore, it is necessary to design for accurate data-driven temperature control for chiller equipment. In this research, support vector regression is applied to the classic PID control for accurate temperature control. Simulated annealing is applied to find optimal PID parameters. The results of the proposed control method show fast and effective control performance for chiller equipment.

흡수식 냉동시스템의 고장현상 분석과 진단 (Fault Symptom Analysis and Diagnosis for a Single-Effect Absorption Chiller)

  • 한동원;장영수;김용찬
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.587-595
    • /
    • 2015
  • In this study, fault symptoms were simulated and analyzed for a single-effect absorption chiller. The fault patterns of fault detection parameters were tabulated using the fault symptom simulation results. Fault detection and diagnosis by a process history-based method were performed for the in-situ experiment of a single-effect absorption chiller. Simulated fault modes for the in-situ experimental study are the decreases in cooling water and chilled water mass flow rates. Five no-fault reference models for fault detection of a single-effect absorption chiller were developed using fault-free steady-state data. A sensitivity analysis of fault detection using the normalized distance method was carried out with respect to fault progress. When mass flow rates of the cooling and chilled water decrease by more than 19.3% and 17.8%, respectively, the fault can be detected using the normalized distance method, and COP reductions are 6.8% and 4.7%, respectively, compared with normal operation performance. The pattern recognition method for fault diagnosis of a single-effect absorption chiller was found to indicate each failure mode accurately.

터보냉동기의 고효율 운전을 위한 협조 방식 기반의 압축기 대수제어 (Operating Number Control of Compressors Based on Cooperative Logic for a High Efficiency Centrifugal Water Chiller)

  • 정석권;임승관;류근수
    • 설비공학논문집
    • /
    • 제27권5호
    • /
    • pp.233-240
    • /
    • 2015
  • This paper discusses compressors operating number control strategy using cooperative logic to cope with variable partial load for high efficiency of a centrifugal water chiller. The cooperative logic is composed of a speed-up and speed-down controller, enabling smooth operation of compressors and equivalent distribution of thermal load in each compressor. This centrifugal water chiller design can be operated with high efficiency without incurring excessive energy waste and large transient phenomena at partial load states. Simulations in MATLAB and experiments in a real chiller system were conducted and verified the high efficiency control of a centrifugal water chiller achieved by the suggested strategy.

현장에서 운전중인 터보냉동기의 냉수와 냉각수 조건 변화에 따른 성능 해석 (In-Situ Performance Analysis of Centrifugal Chiller According to Varying Conditions of Chilled and Cooling Water)

  • 김영일;장영수;신영기;백영진
    • 대한기계학회논문집B
    • /
    • 제26권3호
    • /
    • pp.482-490
    • /
    • 2002
  • This paper presents modelling and analyzing method of centrifugal chiller which has a rated capacity of 200 RT(703 kW) through on-site performance test. Field performance data of a chiller installed in a research building of KIST have been collected. Simple models were developed for predicting the heat exchanger and system performances by regression of chiller operation data during 5 days in August. The models proposed here account for the effect of variations of cooling capacity, temperatures and flew rates of secondary fluids. The proposed models can predict the actual performance data from June to September within $\pm$ 5% error. The COP of centrifugal chiller are estimated under the standard rating conditions and reduced mass flow rates of chilled and cooling water.

전축열방식 빙축열 시스템의 최적제어 알고리즘 (Optimal Control Algorithms for the Full Storage Ice Cooling System)

  • 한도영;이준호
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.350-357
    • /
    • 2002
  • Optimal control algorithms for the full storage ice cooling system were developed by using a dynamic simulation program. Control algorithms for the storage charging mode were developed for the chiller outlet temperature setpoint control and the chiller capacity control. Control algorithms for the storage discharging mode were developed for the proper mode selection, the storage-only mode control, and the storage-priority chiller-shared mode control. Two different cases of the expected outdoor air temperature profile and the expected cooling load profile were used to analyze the effectiveness of these algorithms. Simulation results show the energy savings and the satisfactory controls of the ice storage system. Therefore, control algorithms developed for this study may effectively be used for the improved control of the ice storage cooling system.

냉방부하 변동을 고려한 빙축열시스템의 경제적 운전방식 (Control strategy for economic operation of an ice-storage system considering cooling load variation)

  • 정성훈;이대영;강병하;김우승
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.140-149
    • /
    • 2000
  • A comparative analysis was peformed on the operation cost at partial loads between ice storage systems with the two conventional control strategies, i.e., storage priority and chiller priority. The storage priority control is shown to be more economic for small cooling loads, while the chiller priority control is superior when the cooling load is as large as the design value. Based on this finding, a new control strategy is devised for an ice-storage system to minimize the operation cost at any cooling load. The new control strategy is found to be comparable to the chiller priority for large cooling loads, while it is more economic for small loads compared to the conventional control strategies. The practicality of the new control strategy is also confirmed through a performance test applying the new control strategy to an existing ice-storage system.

  • PDF