• 제목/요약/키워드: Chiller System

검색결과 190건 처리시간 0.033초

R290 냉매를 이용한 수소 충전소 냉각시스템 엑서지 분석 및 공정 최적화 (Exergy Analysis and Optimization of Chiller System in Hydrogen Fueling Station Using R290 Refrigerant)

  • 현수빈;최정호
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.356-364
    • /
    • 2021
  • During the hydrogen fueling process, hydrogen temperature inside the compressed tank were limited below 85℃ due to the allowable pressure of tank material. The chiller system to cool compressed hydrogen used R407C, greenhouse gas with a high global warming potential (GWP), as a refrigerant. To reduce greehouse gas emission, it should be replaced by refrigerant with a low GWP. This study proposes a chiller system for fueling hydrogen with R290, consisted in propane, by applying the C3 pre-cooled system use d in the LNG liquefaction process. The proposed system consisted of hydrogen compression and cooling sections and optimized the operating pressure through exergy analysis. It was also compared to the exergy efficiency with the existing system at the optimal operating pressure. The result showed that the optimal operating pressure is 700 kPa in 2-stage, 840 kPa/490 kPa in 3-stage, and the exergy efficiency increased by 17%.

사무소 건물에서 냉동기의 부분부하율 및 냉방 에너지 성능 특성 분석 (A Detailed Analysis of the Part Load Ratio and Cooling Energy Characteristics of Chiller Operation in an Office Building)

  • 서병모;유병호;이광호
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.567-573
    • /
    • 2015
  • Commercial buildings account for significant portions of the total building energy in Korea, and thus, a variety of research on chiller operation has been carried out. However, most of the studies were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in existing studies. In this study, the part load ratio and the operating characteristics of the vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. As a result, significant portions of total operating hours, cooling load, and energy consumption turned out to be in the part load ratio range of 0 through 50%. Thus, energy consumption was significantly affected by the chiller COP at low part load conditions, indicating that chiller operation at the part load is an important factor in commercial buildings.

Offset 베어링을 활용한 터보냉동기의 회전체동역학 설계 (Rotor Dynamic Design of the Centrifugal Chiller Using Offset Bearing)

  • 이창중;박용석;이준근
    • 대한기계학회논문집A
    • /
    • 제29권2호
    • /
    • pp.239-246
    • /
    • 2005
  • A rotor dynamic analysis is implemented to confirm the vibration stability of the high speed centrifugal chiller coupled with gear system. As the rotating speed of the centrifugal chiller under investigation is increased up to 17605rpm at the pinion rotating part, the bearing instability is getting higher and, furthermore, the rotor-bearing system might experience a few critical speed which lead to system failure due to the excessive vibration. In this study, considering the loading capacity and stability conditions, offset journal bearings are adopted for the pinion rotating system and general cylindrical bearings are used for motor part. From the modal analysis, the system is found to be stable as the critical damping ratio which shows the damping characteristics of the system are positive over all operating ranges, and in addition, the synchronous rotating frequency does not come across with any whirl natural frequency. From these results the authors confirm the vibration stability of the rotor-bearing system suggested in this study.

고속회전용 터보냉동기의 회전체 동역학 해석 (Rotor Dynamic Analysis of the High Speed Centrifugal Chiller)

  • 이준근;박용석
    • 한국산학기술학회논문지
    • /
    • 제4권3호
    • /
    • pp.193-198
    • /
    • 2003
  • 증속기어장치를 이용한 고속회전 터보냉동기 시스템에 대한 회전체 동역학 설계 및 해석을 수행하였다. 특히 피동축의 회전수가 17,605 rpm가지 상승하여 회전체 안정성에 문제가 될 것으로 예측하여 특수베어링의 일종인 Offset베어링을 적용하였고, 구동축의 베어링은 단순베어링인 진원형 베어링을 적용하였다. 모드해석결과 회전체 시스템의 고유진동수가 어떠한 가진성분과 교차하지 않는 것이 확인 되었고, 전 운전영역에 걸쳐 감쇠값이 양의 값을 갖는 것을 알 수 있었으며 설계된 회전체 시스템이 정격운전 상태에서 충분한 안정성을 갖고 작동할 수 있음을 확인하였다.

  • PDF

마이크로 가스터빈 열병합장치 성능특성 연구 (Study on the Performance Characteristics of Micro Gas Turbine (MGT) Co-generation System)

  • 허광범;김재훈
    • 한국소음진동공학회논문집
    • /
    • 제16권9호
    • /
    • pp.964-970
    • /
    • 2006
  • Micro gas turbine(MGT) has received attention recently as small-scale distributed power sources. With characteristics such as their small size, lightweight, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of ' applications, including residential and small-scale industrial use. It is very easier to start-up and stop the MGT system which is the friendly environmental power system has just below the 9ppm NOx emmission and good quality of noise level. The exhaust heat emitted by the MGT is in the form of about $300^{\circ}C$ clean exhaust gas. The exhaust gas is suitable for absorption chiller/heater system. 1 has researched performance characteristics of the 60 kW class MGT-absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated.

캡슐형 빙축열시스템에 대한 운전 시뮬레이션 및 에너지비용 분석 (Simulation and Energy Cost Calculation of Encapsulated Ice Storage System)

  • 이경호;주용진;최병윤;김상준
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.63-73
    • /
    • 1999
  • Ice storage systems are used to shift the peak load in day time into night time in summer. This paper describes a system simulation of partial ice storage system composed of an encapsulated ice storage tank, a screw compressor chiller, a heat exchanger, and a brine pump. For the system simulation, a one-dimensional model of ice storage tank is developed and validated by comparison with the performance data from measurements of an ice storage tank installed at a building. The control strategies considered in this study are chiller priority and storage priority being used commercially. The system is simulated with design cooling load of 600 RT peak load in design day and with off-design day cooling load, and the electric energy costs of the two control strategies for the same system size are compared. As a result of calculation, the energy consumption in a week for storage priority is higher than that for chiller priority control. However due to lower cost of night electric charge rate, energy cost for storage priority control is lower than chiller priority.

  • PDF

베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구 (An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier)

  • 이흥주;장영수;강병하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.36-41
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. FDD algorithm can detect refrigerant leak failure, when 20% amount of charged refrigerant for normal operation leaks from the water chiller. The refrigerant leak failure caused COP reduction by 6.7% compared with normal operation performance. When two kinds of faults, such as a decrease in the mass flow rate of cooling water and temperature sensor fault of cooling water inlet, are detected, COP is a little decreased by these faults.

  • PDF

혼합흐름 사이클용 흡수식 냉온수기의 성능특성 (Performance Characteristics on the Mixed Flow Type Absorption Chiller-Heater)

  • 윤정인;신기부;박석호
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.351-360
    • /
    • 1996
  • This study focuses on the development and evaluation of the high efficiency absorption chiller-heater, which can be applied to a direct gas fired, double effect system with 40RT (508,000kJ) cooling capacity. The performance of the absorption chiller-heater is investigated through cycle simulation and experiment to obtain the system characteristics with the inlet tenperature of cooling, chilled water, and gas input flow rate. The efficiency of the different cycles has been studied and the simulation and experiment results show that higher coefficient of performance could be obtained for mixed flow cycle. The five percent difference was obtained from the comparison between experimental and cycle simulation results. As a result of this study, the optimum designs were determined based on the operating conditions and the coefficient of performance.

  • PDF

냉동기 성능 진단을 위한 적응형 뉴로퍼지(ANFIS) 모델 개발 (Prediction of Vapor-Compressed Chiller Performance Using ANFIS Model)

  • 신영기;장영수;김영일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.89-95
    • /
    • 2001
  • On-site diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the on-site diagnosis is to predict the COP of a target chiller. Many models based on thermodynamics background have been proposed for the purpose. However, they have to be modified from chiller to chiller and require deep insight into thermodynamics that most of field engineers are often lacking in. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). Quality of the training data for ANFIS, sampled over June through September, is assessed by checking COP prediction errors. The architecture of the ANFIS, its error bounds, and collection of training data are described in detail.

  • PDF

부분축열식 빙축열시스템의 냉방에너지소비 절약을 위한 냉동기 On-Off 제어기법의 평가 (Evaluation of Chiller On-Off Control of Partial Ice Storage System for Energy Saving in Cooling Operation)

  • 이경호;최병윤;이상렬;한승호
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2000년도 춘계 학술발표회 논문집
    • /
    • pp.69-74
    • /
    • 2000
  • This paper describes an operation strategy of ice storage systems for energy saving during building cooling. In this study, chiller is assumed not having function of part load control. Thus, it is needed to adopt on-off control with the objective function of summed energy consumption for minimum energy consumption. A conventional control strategy compared with the chiller-on-off control is chiller-priority control. in this control chiller operates as its full capacity and ice storage meets the rest of the cooling load.

  • PDF