• 제목/요약/키워드: Chilled water temperature

검색결과 68건 처리시간 0.026초

최속 강하법을 이용한 흡수식 냉동공조시스템 제어 (Control of the Absorption Air Conditioning System by Using Steepest Descent Method)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.495-501
    • /
    • 2003
  • Control algorithms for the absorption air conditioning system may be developed by using dynamic models of the system. The simplified effective dynamic models, which can predict the dynamic behaviors of the system, may help to develop effective control algorithms for the system. In this study, control algorithms for an absorption air conditioning system were developed by using a dynamic simulation program. A cooling water inlet temperature control algorithm, a chilled water outlet temperature control algorithm, and a supply air temperature control algorithm, were developed and analyzed. The steepest descent method was used as an optimal algorithm. The simulation results showed energy savings and the effective controls of an absorption air conditioning system.

The Optimal Control of an Absorption Air Conditioning System by Using the Steepest Descent Method

  • Han Doyoung;Kim Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권3호
    • /
    • pp.123-130
    • /
    • 2004
  • Control algorithms for an absorption air conditioning system may be developed by using dynamic models of the system. The simplified effective dynamic models, which can predict the dynamic behaviors of the system, may help to develop effective control algorithms for the system. In this study, control algorithms for an absorption air conditioning system were developed by using a dynamic simulation program. A cooling water inlet temperature control algorithm, a chilled water outlet temperature control algorithm, and a supply air temperature control algorithm, were developed and analyzed. The steepest descent method was used as an optimal algorithm. Simulation results showed energy savings and the effective controls of an absorption air conditioning system.

만액식 증발기의 열전달 촉진관에서 저온 비등열전달의 이력현상 특성 (Hysteresis on Boiling Heat Transfer at Low Temperature on Enhanced Tubes in a Flooded Evaporator)

  • 윤현필;박종익;정진희;강용태
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.254-260
    • /
    • 2003
  • The boiling characteristics for R134a are studied to clarify the hysteresis at low temperature on enhanced tubes of a flooded evaporator. Initial boiling conditions, refrigerant temperature, and inlet temperature of the chilled water are considered as the key parameters of the experiments. Unlike previous studies of the boiling heat transfer with uniform heat flux and uniform wall temperature, the wall temperature was varied along the tube. In, this study, it was found that the hysteresis of the temperature overshoot (705) at the onset of nucleate boiling initially at the inlet section of the tube. It is also concluded that the abnormal operation can be avoided during the low temperature boiling if the refrigeration system is started with LMTD larger than $3.4^{\circ}C$ at initial stage and larger than $1.0^{\circ}C$ at normal stage.

저온 잠열 축열조내의 열유동 특성에 관한 연구 (A study on Characteristics of Heat Flow of Low Temperature Latent Thermal Storage System)

  • 이원섭;박정원
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.33-43
    • /
    • 1999
  • The study on ice thermal storage system is to improve total system performance and increase the economical efficiency in actual all-conditioning facilities. To obtain the high charging and discharging efficiencies in ice thermal storage system, the improvement of thermal stratification is essential, therefore the process flow must be piston flow in the cylindrical type. With the relation of the aspect ratio(H/D) in the storage tank, the stratification is formed better as inlet flow rate is smaller. If the inlet and the outlet port are settled at the upside and downside of the storage tank, higher storage rate could be obtainable. In case that the flow directions inside the thermal storage tank are the upward flow in charging and the downward in discharging, thermal stratification is improved because the thermocline thickness is maitained thin and the degree of stratification increases respectively. In the charging process, in case of inlet flow rate the thermal stratification has a tendency to be improved with the lower flow rate and smaller temperature gradient in case of inlet temperature, the large temperature difference between inflowing water and storage water are influenced from the thermal conduction. The effect of the reference temperature difference is seen differently in comparison with the former study for chilled and hot water. In the discharging process, the thermal stratification is improved by the effect of the thermal stratification of the charging process.

  • PDF

급냉 제강 슬래그 잔골재 대체율에 따른 모르타르의 유동성 및 압축강도 특성 (The Properties of Flow and Compressive Strength of Mortar According In Replacement Ratio of Rapidly-Chilled Steel Slag Pine Aggregate)

  • 조성현;김진만;한기석;김무한
    • 콘크리트학회논문집
    • /
    • 제17권1호
    • /
    • pp.77-84
    • /
    • 2005
  • 제강 슬래그는 제강 공정에서 발생되는 부산물로서 주로 에이징 한 후 도로용 노반재로 사용된다. 제강 슬래그내에 포함된 free-CaO와 물과의 반응하여 체적팽창을 일으키기 때문에 공기중에 장시간 에이징 하는 것이 필요하다. 이러한 문제 때문에 제강 슬래그를 콘크리트용 골재로 사용하는데 어려움이 있다. 그러나, 본 연구에서는 고온의 용융상태에서 고속공기로 뿜어 급냉시킨 제강 슬래그를 사용하였다. 이와 같이 급냉시키는 방법은 제강 슬래그내의 free-CaO의 생성량을 저감시킨다. 본 연구에서는 통계적 실험계획법 중 일원배치법을 이용하여 급냉 제강 슬래그 대체율이 플로우, 고성능감수제의 첨가율, 물-시멘트비 및 압축강도 등 모르타르의 특성에 미치는 영향을 검토하였다. 또한, 이들 데이터를 분산분석 후 F-검정을 실시하여 급냉 제강 슬래그가 모르타르의 특성에 유의한 영향을 주고 있는 지를 검정하였다. F-검정결과 유의수준 $1\%$내에서 급냉 제강 슬래그 대체율이 증가할수록 모르타르의 플로우 증가, 고성능감수제 첨가율 및 물-시멘트비의 감소, 압축강도의 증진에 크게 영향을 미치는 것을 검정하였다. 또한, 유동성 및 압축강도를 고려할 때 강모래에 대하여 급냉 제강 슬래그 대체율 $75\%$를 사용하는 것이 가장 우수한 유동성과 압축강도 발현하는 것으로 나타났다.

냉방열원의 경제성 평가를 위한 건물에너지 회귀식 산출 (Energy Regression Analysis for Economic Evaluation of Cooling Plants)

  • 김영섭;김강수
    • 설비공학논문집
    • /
    • 제14권5호
    • /
    • pp.377-384
    • /
    • 2002
  • For economic evaluation of cooling plant equipments, it is necessary to simplify energy Prediction method, which should includes efficiency corrected by part-load ratio. This study proposed simplified method with regression equations of time-average partial loads and refrigerator capacity. DOE-2 Program was used to carry out a parametric study of twelve design variables. Five input variables were considered to be significant and were used in the regression equations. To test accuracy of simplified method, calculated results were compared with DOE-2 simulated results. Test result showes a good agreement with the simulation result with an error of 5.9∼7.6%. It is expected that this method can be used as an easy prediction tool for comparing energy use of different cooling plants during the early design stage.

공조시스템의 에너지절약을 위한 Fuzzy제어 적용방안 연구 (Fuzzy Control Application Strategy for Energy Saving in HVAC System)

  • 안병천;송재엽
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권2호
    • /
    • pp.31-37
    • /
    • 2007
  • The fuzzy control algorithm for HVAC system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with fuzzy control are supply air temperature, chilled water temperature and condenser temperature. This study has been done by using TRNSYS program in order to analyze the HVAC system response. As a result, the fuzzy control algorithm with PID algorithm shows good energy performance in comparison with conventional one.

  • PDF

Effect of Cool Drinking Water on Production and Shell Quality of Laying Hens in Summer

  • Glatz, P.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권6호
    • /
    • pp.850-854
    • /
    • 2001
  • Feed intake, egg weight, rate of lay and shell quality characteristics were measured in an Australian tinted egg laying strain from 31-42 weeks of age, housed at $30^{\circ}C$ and provided drinking water at 5, 10, 17 and $30^{\circ}C$. In a second experiment a European brown egg laying strain (59-66 weeks of age) housed at $30^{\circ}C$ were provided drinking water at 5, 10, 15 and $30^{\circ}C$. Brown egg layers given cool drinking water (5, 10 and $15^{\circ}C$) consumed more (p<0.05) feed and produced significantly (p<0.05) thicker and heavier shells than hens given drinking water at ambient temperature ($30^{\circ}C$). However the tinted egg layers given chilled drinking water only consumed more (p<0.05) feed and produced thicker (p<0.05) and heavier (p<0.05) shells when consuming drinking water at $5^{\circ}C$. As the tinted egg layers acclimatised to the environmental temperature there was a decline in the influence of cool drinking water on feed intake and shell quality. For brown egg layers, however, cool drinking water resulted in an improvement (p<0.05) in feed intake and shell quality over the entire period birds were provided cool water. These studies suggest that there is potential for using cool drinking water to improve feed intake and shell quality of hens housed under hot conditions. The combination of high ambient temperature and high drinking water temperature, a common occurrence in Australian layer sheds, should be avoided.

중앙냉방시스템의 준최적 설정점제어기법 구현에 관한 연구 (An Implementation for Near-Optimal Set Point Control for Central Cooling Systems)

  • 백승재;송재엽;안병천;주영덕;김진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.46-51
    • /
    • 2007
  • The near-optimal control algorithm for central cooling system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with near-optimal control are supply air temperature and chilled water temperature. This study has been done by using LapVIEW program with PID control in order to analyze the central cooling system energy saving.

  • PDF

고밀도 내부부하 중심 건물의 에너지 절약적 공조방식에 대한 연구 (Viability of HVAC System for Energy Conservation in High Density Internal-load Dominated Buildings)

  • 조진균;정차수;김병선
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.530-537
    • /
    • 2010
  • With the advancement of technology, the density of IT equipment, heat load and power consumption continue to increase in high density internal-load dominated buildings as datacenters. To improve the HVAC system's energy performance and efficiency, there is a need to find methods of using outside air. Through cooling tower control that is based on outside wet-bulb temperature, the water-side economizer made it possible to achieve a maximum energy performance improvement of about 16.6% over the basic chilled water system, whereas the air-side economizer, through control based on outdoor air enthalpy, made it possible to achieve about 42.4% improvement.