• Title/Summary/Keyword: Chest trauma

Search Result 544, Processing Time 0.032 seconds

Esophageal Rupture Due to Diving in Shallow Waters

  • Han, Sung Ho;Chon, Soon-Ho;Lee, Jong Hyun;Lee, Min Koo;Kwon, Oh Sang;Kim, Kyoung Hwan;Kim, Jung Suk;Lee, Ho hyoung;Chon, June Raphael
    • Journal of Trauma and Injury
    • /
    • v.31 no.1
    • /
    • pp.16-18
    • /
    • 2018
  • Delayed esophageal rupture due to blunt injury is not new. However, rupture due to suspected barotrauma is very rare. We describe a case of esophageal rupture in a male 24-year-old patient after diving in shallow waters. The patient was quadriplegic and could not experience the typical chest pain related to rupture and resulting mediastinitis. The rupture was discovered 4 days after emergency decompressive laminectomy and fusion for his cervical spine. The rupture was evidently caused by barotrauma and was discovered four days after admission. He underwent primary closure and pericardial flap as a life-saving procedure.

Clinical Study of 53 Patients Requiring open Thoracotomy After Thoracic Injuries (흉부외상 환자중 개흉술이 필요했던 53례에 관한 임상적 고찰)

  • 김규만
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1115-1124
    • /
    • 1991
  • Recently the thoracic injuries have been markedly increasing due to the vast increase of traffic accident, industrial disaster, and incidental accident as well as the frequent use of the murderous weapons including gun or rifle. Because the thoracic injuries could involve the heart, lung, and great vessels, and would influence the lives, prompt diagnosis and adequate treatment are essential. Most of thoracic injuries can be managed with the conservative treatment and simple surgical procedure such as closed thoracostomy, but certain cases require open thoracotomy to preserve lives and to return to their normal environment. The authors have analysed the result of 53 cases of open thoracotomy after thoracic injuries mainly according to the patient`s chart review. The mean age was 33.4 years old and male to female ratio was about 5: l. Injury mechanisms that elicited thoracic trauma indicated for open thoracotomy were penetrating[47%] and non-penetrating[53%] injuries. The Most common type of the thoracic lesion was hemothorax with or without pneumothorax and diaphragm rupture was the second. 58\ulcornero of thoracic injuries were accompanied by abdominal injuries and 47% by bone fractures. 34 patients were operated within 24 hours after injury and their average elapsed time was 13.6 hour. The remained patients were operated after 24 hours and their average elapsed time was 7.8 days. 71 cases of operative procedures containing some overlappings were performed: diaphragm repair[28], bleeding control[12], pulmonary and cardiac repair[4 cases] Postoperative complication rate was 32.1% and operative mortality rate was 9.4%[5/53].

  • PDF

Design & Animal Experiment of Artificial Oxygenator (인공폐(산화기) 제작과 실험)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.259-265
    • /
    • 1982
  • We have designed a new type of bubble oxygenator (KOREA-KIM VENOTHERM OXYGENATOR) made of PVC sheet and deforming mesh incorporated in the heat exchanger, and evaluated in experimental animal for the analysis of it`s efficiency. The Oxygenator has low priming volume with high flow rate up to 6 L/rain, and efficiency of heat exchanger was excellent as 1-$1.5^{\circ}C.$ using total cardiopulmonary bypass method under moderate to deep hypothermia. Average priming volume of 1317 ml with 30% hemodilution method was perfused with an average of 1.1-3.0 L/min.$M^2$of arterial blood and pure oxygen at a rate of 2-3.4 L/min for 49.6 minutes continuously in average. During total cardiopulmonary bypass, average $PaO_2$ was $159.8{\pm}60$mmHg, $PaCO_2$ $41.0{\pm}3$mmHg respectively under $SaO_2$ over 96% with systolic arterial pressure of 70 mmHg and CVP of 5-10 cm$H_2O$. Plasma free Hemoglobin was $7.0{\pm}4$ mg/dl with 25% drop of hemoglobin and hematocrit at the end of cardiopulmonary bypass. This KKV Oxygenator was observed to have excellent capabillty of oxygen and carbon dioxide gas transfer with small amount of blood trauma, and the efficiency of heat exchanger was satisfactory during cooling and rewarming of the bubbled blood. Disadvantages have included the somewhat poor deforming effect due to loose PVC fiber mesh, the extracompact character of Teflon filters, and the rough inner surface of the heat exchanger copper pipes.

  • PDF

The Use of Nylon Tube as Aortic Prostheses: 2 Cases (Nylon tube를 이용한 대동맥 Prostheses (2례))

  • 윤윤호;정영환;김근호
    • Journal of Chest Surgery
    • /
    • v.3 no.1
    • /
    • pp.47-54
    • /
    • 1970
  • This is a report on two cases of aortic prostheses using Nylon tube. (Edwards-Tapp A-G Tube, Chemically treated braided Nylon arterial grafts). Especially, the complications after infection of synthetic graft are discussed with reviewing literature. First case was the patient who came to our hospital with rupture of the right femoral artery at the femoral fossa due to pyogenic necrotic process. After femoral arterial prostheses, good pulsation of dorsal artery of foot was obtained. However, the tube was obstructed after 8 weeks postoperatively due tll the complication of infection. In spite of the tube was removed because of obstruction and foreign body reaction of synthetic graft, an amputation of the leg was not necessary for formation of good collateral circulation. Second case was a case of aortic aneurysmal rupture in thoraco-abdominal junction which developed by the trauma of rib resection for osteomyelitis of the left 12th. rib An implantation of aortic graft was performed at the lowest tho13cic aorta by the way of thoraco-abdominal bypass without arterial pump. However, infection produced pyothorax in the left pleural cavity, exposing the tube within the pyothorax. The rupture of the anastomosed upper line occurred in 8 weeks postoperatively and the patient expired.

  • PDF

Quantitative analysis of hemothorax by computed tomography (흉부 전산화 단층촬영을 이용한 혈흉의 정량분석)

  • 강청희
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.228-232
    • /
    • 1995
  • Computed tomography[CT is an effective technique for the evaluation of the thorax following blunt trauma. To evaluate multiply injured 30 patients who were diagnosed as hemothorax in emergency room, computed tomography of thorax was done. The thickness of slice was one centimeter and the entire pleural cavity from the apex to the costophrenic angle was included in the evaluation. Integration and addition of the hemothorax area for each CT slice was made and amount of blood in the pleural cavity was estimated. The slice which showed largest area of hemothorax was selected and the height and width of the hemothorax area were measured. The number of slices which showed radiographic evidence of hemothorax was counted. Regression analysis was done and measured amount of hemothorax, the height and width of the hemothorax area for each slice and number of slices were put as variables. And following equation was derived. V=108.3A-0.8B-7.4C+84.7 [R2=0.74 [ V: amount of hemothorax, A: height, B: width, C: number of slices Total amount of blood from thoracic drainage was compared to the measured amount by computed tomography and the relation between the two values was statistically significant.[p=0.001 In conclusion, quantitative estimation of size of hemothorax was possible by the above equation and the process was very helpful for determination policy of treatment of individual patient.

  • PDF

Idiopathic Hypertrophic Cranial Pachymeningitis Misdiagnosed as Acute Subtentorial Hematoma

  • Park, Ik-Seong;Kim, Hoon;Chung, Eun-Yong;Cho, Kwang-Wook
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.2
    • /
    • pp.181-184
    • /
    • 2010
  • A case of idiopathic hypertrophic cranial pachymeningitis (IHCP) misdiagnosed as an acute subdural hematoma is reported. A 37-year-old male patient presented with headache following head trauma 2 weeks earlier. Computerized tomography showed a diffuse high-density lesion along the left tentorium and falx cerebri. Initial chest X-rays revealed a small mass in the right upper lobe with right lower pleural thickening, which suggested lung cancer, such as an adenoma or mediastinal metastasis. During conservative treatment under the diagnosis of a subdural hematoma, left cranial nerve palsies were developed (3rd and 6th), followed by scleritis and uveitis involving both eyes. Magnetic resonance imaging (MRI) revealed an unusual tentorium-falx enhancement on gadolinium-enhanced T1-weighted images. Non-specific chronic inflammation of the pachymeninges was noticed on histopathologic examination following an open biopsy. Systemic steroid treatment was initiated, resulting in dramatic improvement of symptoms. A follow-up brain MRI showed total resolution of the lesion 2 months after steroid treatment. IHCP should be included in the differential diagnosis of subtentorial-enhancing lesions.

Supradiaphragmatic Heterotopic Liver Presenting as a Pleural Mass: A Case Report

  • An, Jung-Suk;Han, Joung-Ho;Lee, Kyung-Soo;Choi, Yong-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.3
    • /
    • pp.191-195
    • /
    • 2010
  • Abnormally located liver tissue has been described in the vicinity of the liver proper, near anatomical structures such as the gallbladder, the umbilical fossa, the adrenal gland, the pancreas, and the spleen. Supradiaphragmatic ectopic liver is a rare finding, but has been reported to have been found in the intrathoracic cavity and in the pericardium. In the majority of supradiaphragmatic ectopic liver cases, there was an accompanying transdiaphragmatic pedicle of the main liver body into the abdominal cavity. In a minority of supradiaphramatic ectopic liver cases, the liver was completely separated from the abdominal cavity without a connection between the thorax and the abdomen, with accompanying diaphragmatic anomalies. We describe one case of intrathoracic ectopic liver in a patient with a previous history of lower chest wall trauma, and a brief review of the English-language medical literature on this topic.

Heart Failure by a Calcific Pericardial Ring -A case report - (식회화된 심낭 고리에 의한 심부전즙 - 1예 보고)

  • Hong Seong-Beom;Ahn Byung-Hee;Ryu Sang-Wan;Jung In-Suk;Kim Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.38 no.9 s.254
    • /
    • pp.648-651
    • /
    • 2005
  • Calcific constrictive pericarditis is considered to be a nonspecific response to chronic inflammation. This disease has become rare, because the cause of it is usually tuberculosis, which has the tendency to decrease. Other possible causes of it include radiation, rheumatoid disorders, sarcoidosis, and trauma. Whatever the etiology, it can lead to cardiac tamponade by reducing cardiac diastolic filling. We report, herein, the case of a patient with heart failure by a calcific pericardial ring.

Hemodynamic effects of induced overtransfusion of blood in dogs (과량수혈이 혈역학에 미치는 영향)

  • 기노석
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.418-423
    • /
    • 1984
  • Appreciation of the large volume deficits which may occur in surgical or trauma patients due to blood loss has led to vigorous transfusion techniques designed to overt hypovolemic shock and ischemic damage to vital organs which may develop in minutes during the hypovolemic state. In a significant proportion of patients treated with massive rapid blood or fluid transfusion, hypervolemia occurs and life threatening pulmonary edema may develop. Especially, hypervolemia may occur during transfusion for preventing development of the so-called low output syndrome following cardiac surgery. However, the most effective indicator which reveals the adequate level of transfusion is not settled yet. The present study was aimed to compare the effectiveness of the indicators suggested thus far and to determine the most sensitive one. Eight dogs were experimentally studied in terms of left atrial pressure, pulmonary arterial systolic pressure, central venous pressure, mean systemic arterial pressure and heart rate before and after induced hypervolemia with infusion of 600ml heparinized homologous blood. Immediately after induced overtransfusion of the blood, pulmonary arterial systolic pressure increased 75.0%, in omparison with the control before transfusion, left atrial pressure 58.8%, central venous pressure 44.6%, and mean systemic arterial pressure 10.1%, one hour after transfusion, pulmonary arterial systolic pressure 40.0%, left atrial pressure 21.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, central venous pressure 14.5%, and mean systemic arterial pressure 3.2%, respectively. Heart rate showed no significant change throughout the experiment. These result suggested that the changes of the pulmonary arterial systolic pressure is the most sensitive indicator for detection of hypervolemia during blood transfusion.

  • PDF

Clinical Application of OXYREX Hollow Fiber Membrane Oxygenator (국산 막형 산화기 (OXYREX)의 체외순환 임상 성적 - 개심수술 40례 적용 -)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1049-1056
    • /
    • 1990
  • The OXYREX hollow fiber membrane oxygenator developed by joint work of KIST and Green Cross Medical company has been evaluated by experimental investigation and clinical application, In this oxygenator gas exchanges occur through small pores of 0.1pm size which are distributed on 70% of surface of polypropylene hollow fiber. The Oxyrex membrane oxygenator consists of 36 thousand hollow fibers and it has 3.3m2 of gas exchange surface. The Oxyrex membrane oxygenator has unique blood flow path: blood enters the oxygenator passes between the hollow fibers and exits through outlet ports, that provides low transmembrane pressure drop. In the animal experiment and in vitro investigations of Oxyrex oxygenator, it showed low transmembrane pressure difference, effective heat exchanger performance, stable gas transfer function and less blood trauma. The Oxyrex oxygenator been used from March, 1990, to October, 1990, in 40 patients undergoing open heart operations. In the clinical applications of Oxyrex, adequate oxygenation[PaO2, 283$\pm$70mmHg] and carbon dioxide removal[PaCO2, 27\ulcorner6mmHg]were maintained under the condition of FiO2: below 0.6, Hct; 25%, perfusion flow; 2.4 L/min, gas flow: 2.1 L/min. During maximum 365 minutes of cardiopulmonary bypass[CPB] time period, the Oxyrex oxygenator maintained stable condition of PaO2, PaCO2 respectively and it also kept low plasma hemoglobin level. The complement proteins C3 and CH50 were not significantly changed pre to post CPB. There were no complications related to the oxygenator during and after the CPB.

  • PDF