• Title/Summary/Keyword: Chest phantom

Search Result 135, Processing Time 0.025 seconds

Study on the Photoneutrons Produced in 15 MV Medical Linear Accelerators : Comparison of Three-Dimensional Conformal Radiotherapy and Intensity-Modulated Radiotherapy (15 MV 의료용 선형가속기에서 발생되는 광중성자의 선량 평가 - 3차원입체조형방사선치료와 세기조절방사선치료의 비교 -)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.335-343
    • /
    • 2012
  • Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photonueutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photonbeams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

Evaluation of the possibility of clinical application by surface dose measurement of ViewRay in MFW treatment (MFW 치료 시 ViewRay의 표면선량 측정에 따른 임상 적용 가능성 평가)

  • Sun, Geo Jun;Son, Sang Jun;Lee, Yang Hoon;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.169-176
    • /
    • 2018
  • Purpose : The purpose of this study is to evaluate clinical applicability of Co-60 ViewRay treatment plan to increase the skin dose in case of high skin dose is required such as Malignant Fungating Wound By measuring the presence / absence of Bolus application and skin dose by the treatment device and comparing it Materials and Methods : Nine inner measuring points of 2.5 cm lattice arrangement and all 13 measuring points including upper and lower left and right measuring points touching the chest and skin were marked. After CT was taken, each treatment plan was formulated through Eclipse and ViewRay-TPS, and a Fixed beam-IMRT treatment plan was formulated so that the left chest V2Gy=95 % is delivered. Before measurement QED detector was calibrated and the QED detector was positioned at the 13 measurement points displayed on Phantom and surface dose of each treatment planner was measured using 5 mm Bolus application using True-beam and View-ray before and after, measure three times and compare each before applying 5 mm Bolus. Results : The surface dose of the Co-60 ViewRay and the linear accelerator appeared at $76.8%{\pm}5.2%$ vs. $67.3{\pm}%7.5%$ and the surface dose after application of 5 mm Bolus was $87.6%{\pm}8.9%$ vs. $80.3%{\pm}10.2%$ It was measured at 10.2 % (p<0.001). Conclusion : As a result of the surface dose measurement of each treatment instrument, Co-60 ViewRay confirmed that the surface dose reached 95.6 % of 6 MV Linac with conventional 5 mm bolus, despite not using Bolus (p<0.001). Also, by utilizing magnetic resonance images for each treatment, it is possible to observe the change in the treatment site without the problem of exposure, it is easy to formulate an adaptive treatment plan and it is easy to secure the skin dose, so the size In the case of Malignant Fungating Wound patients who need fast skin changes and need high skin doses, Co-60 ViewRay is considered to be more useful than linear accelerators.

  • PDF

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

Medical Radiation Exposure in Children CT and Dose Reduction (소아 CT 촬영시 방사선 피폭과 저감화 방법)

  • Lee, Jeong-Keun;Jang, Seong-Joo;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.1
    • /
    • pp.356-363
    • /
    • 2014
  • Recently pediatric CT has been performed by reduced dose according to tube current modulation이라고, this fact has a possibility more reduce a dose because of strong affect depend on tube current modulation. Almost all MDCT snow show and allow storage of the volume CT dose index (CTDIvol), dose length product (DLP), and effective dose estimations on dose reports, which are essential to assess patient radiation exposure and risks. To decrease these radiation exposure risks, the principles of justification and optimization should be followed. justification means that the examination must be medically indicated and useful. Results is using tube current modulation이라고 tend to the lower kV, the lower effective dose. In case of use a low dose CT protocol, we found a relatively lower effective dose than using tube current modulation. Average effective dose of our studies(brain, chest, abdomen-pelvis) less than 47%, 13.8%, 25.7% of germany reference dose, and 55.7%, 10.2%, 43.6% of UK(United Kingdom) reference dose respectively. when performed examination for reduced dose, we must use tube current modulation and low dose CT protocol including body-weight based tube current adaption.

Evaluation of Image Quality for Diagnostic Digital Chest Image Using Ion Chamber in the Total Mastectomy (변형근치유방절제술 환자의 Ion chamber 변화에 따른 디지털 흉부 영상의 화질 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Park, Hyong-Hu;Kim, Donghyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.204-210
    • /
    • 2013
  • The patients who had been operated total mastectomy are different from general women in their breasts thickness due to breast surgery. As a result, digital chest image from total mastectomy patients will be different attenuation. The main objective for this study is to show that a proper Ion chamber standard combination measuring MTF which is objective basis for Digital image, when be x-ray for total mastectomy patient. We have designed the unique number that shown Left is 1, Right is 2, Center is 3 and have put the edge phantom on detector ion chamber. Lastly, we have obtained experiment images. The evaluations of all image quality have measured by 50% MTF of spatial resolution and absorption dose using Matlab(R2007a). The result showed that average exposure condition, MTF value, absorption dose for 1+3 and 2+3 combinations were 2.745 mAs, 1.925 lp/mm, 0.688 mGy. Consequently, that showed high MTF, DQE and low dose than other combinations. Therefore, a proper changes of ion chambers are able to improve image quality and to reduce radiation exposure when be X-ray for total mastectomy patients. Also, it will be possible to standard for application chamber combination and utilization on clinical detection.

Quantitative Evaluation of Image Quality using Automatic Exposure Control (AEC 사용 유무에 따른 영상의 화질평가)

  • Kim, Gwang-ho;Yoo, Gwan-ju;Kang, Ji-won;Ko, Bong-joo;Kim, Kyoun-lan;Kim, Min-hee;Yoon, Young-woo;Ye, Soo-young;Choi, Seok-yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.86-89
    • /
    • 2015
  • Quantitative Evaluation of Image Quality using Automatic Exposure Control This it leads, the relationship of control and image between of photographing condition, DR proper use method proposing. Chest phantom acquires Chest PA images which it follows in conditional change, Image evaluation factor (SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), PSNR (Peak Signal to Ratio), RMS (Root Mean Square)). It excepted RMS price, SNR, CNR, PSNR the case which uses AEC it came out being high The fact that the quality of image is better there was a case which does not use AEC. but Price it was slight. Image qualitative it was deficient in AEC use presence. Through this, the overall situation and most efficient use of radiation workers is better suited. But Passive AEC use would be appropriate for use rather than proactive AEC.

  • PDF

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

Usefulness in Evaluation of NM Image which It Follows in Onco. Flash Processing Application (Onco. Flash Processing 적용에 따른 핵의학 영상의 유용성 평가)

  • Kim, Jung-Soo;Kim, Byung-Jin;Kim, Jin-Eui;Woo, Jae-Ryong;Kim, Hyun-Joo;Shin, Heui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • Purpose: The image processing method due to the algorism which is various portion nuclear medical image decision is important it makes holds. The purpose of this study is it applies hereupon new image processing method SIEMENS (made by Pixon co.) Onco. flash processing reconstruction and the comparison which use the image control technique of existing the clinical usefulness it analyzes with it evaluates. Materials & Methods: 1. Whole body bone scan-scan speed 20 cm/min, 30 cm/min & 40 cm/min blinding test 2. Bone static spot scan-regional view 200 kcts, 400 kcts for chest, pelvis, foot blinding test 3. 4 quadrant-bar phantom-20000 kcts visual evaluation 4. LSF-FWHM resolution comparison ananysis. Results: 1. Raw data (20 cm/min) & processing data (30 cm/min)-similar level image quality 2. Low count static image-image quality clearly improved at visual evaluation result. 3. Visual evaluation by quadrant bar phantom-rising image quality level 4. Resolution comparison evaluation (FWHM)-same difference from resolution comparison evaluation Conclusion: The study which applies a new method Onco. flash processing reconstruction, it will be able to confirm the image quality improvement which until high level is clearer the case which applies the method of existing better than. The new reconstruction improves the resolution & reduces the noise. This enhances the diagnostic capabilities of such imagery for radiologists and physicians and allows a reduction in radiation dosage for the same image quality. Like this fact, rising of equipment availability & shortening the patient waiting move & from viewpoint of the active defense against radiation currently becomes feed with the fact that it will be the useful result propriety which is sufficient in clinical NM.

  • PDF

Comparison of ESD and Major Organ Absorbed Doses of 5-Year-Old Standard Guidelines and Clinical Exposure Conditions (소아 5세 표준촬영 가이드라인과 임상 촬영조건의 입사표면선량과 주요 장기흡수선량 비교)

  • Kang, A-Rum;Lee, In-Ja;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.355-361
    • /
    • 2017
  • Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied.

Comparison Between T2 and T2.3 Thoracic Sympathetic Block in Palmar Hyperhidrosis (수장부 다한증에서 제 2번 및 제 2,3번 흉부 교감신경절 차단술의 비교)

  • 성숙환;조광리;김영태;김주현
    • Journal of Chest Surgery
    • /
    • v.31 no.10
    • /
    • pp.999-1003
    • /
    • 1998
  • Background: Thoracoscopic sympathetic block in palmar hyperhidrosis has merits in its immediate responsiveness and recovery. In palmar hyperhidrosis, the level of sympathetic chain to be blocked has been somewhat obscure. Materials and methods: To compare the results of T2 with T2,3 sympathetic block, we retrospectively studied 192 patients (T2 group: 84, T23 group: 108) operated on at SNUH with palmar hyperhidrosis between April 1994 and July 1997. We reviewed medical records and recently interviewed the patients by telephone call. Sex and age distribution between two groups showed no significant differences. We performed sympathectomy at the early phase of the syudy until April 1997, and after then, we adopted sympathicotomy rather than sympathectomy. Results: All patients showed symptomatic improvement after the operation. Mean operation times of T2, T23 groups were 61.3$\pm$22.5min, 82.7$\pm$24.8min, respectively(p<0.01). Early postoperative complications, such as Horner's syndrome or chest tube insertion, were not different in two groups. There were no statistical differences of late complications such as compensatory truncal hyperhidrosis, gustatory sweating, and phantom sweating. No patient experienced recurrence of palmar hyperhidrosis during the study period. The only difference was the extent of compensatory truncal hyperhidrosis. The compensatory sweating occurred from axilla to suprapatella in T2 group whereas its extent was from nipple to suprapatella in T23 group. Conclusions: We concluded that T2 thoracic sympathetic block is mandatory for the treatment of primary palmar hyperhidrosis.

  • PDF