• Title/Summary/Keyword: Chemical incompatibility

Search Result 17, Processing Time 0.022 seconds

Fatigue Crack Growth Behavior of NR/EPDM Blend

  • Chung, Woo-Won;Chang, Young-Wook
    • Macromolecular Research
    • /
    • v.9 no.6
    • /
    • pp.319-326
    • /
    • 2001
  • Fatigue crack growth (FCG) behavior of natural rubber/ethylene-propylene-diene rubber (NR/EPDM) blend vulcanizates under dynamic tearing condition was investigated by using a fracture mechanics approach. It appeared that variation of crack growth rate with blend compositions was dependent on the level of imposed tearing energy G. At low tearing energy region, the FCG rates of the blend were lower as the EPDM content was increased, while at high tearing energy region, the trend was reversed. Over the measured range of tearing energy G, all blend compositions showed the lower crack growth rates compared to the average of properties of component elastomers. When the blends were thermally aged, the fatigue resistance of the blends was deteriorated in proportion to the concentration of EPDM phase. Fatigue crack growth behavior of the blends was supposed to be associated with the inhomogeneities of the crosslink structure of the blends arising from cure incompatibility of the EPDM and NR when they are sulphur cured.

  • PDF

Preparation of Waterborne Polyurethane Dispersion Based on Siloxane Polyal (실록산 폴리올의 도입에 따른 수분산성 폴리우레탄의 제조)

  • Yoo, Su-Yong;Kim, Jung-Du;Kam, Sang-Kyu;Moon, Myung-Jun;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.16 no.8
    • /
    • pp.891-896
    • /
    • 2007
  • Waterborne polyurethane dispersions (WPUD) were prepared by poly(ethylene glycol) adipate as the polyester type, ${\alpha},{\omega}-hydroxyalkyl$ terminated polydimethylsiloxane (PDMS-diol) as the polysiloxane type, hexamethylene diisocyanate, and isophorone diisocyanate, dimethylol propionic acid. The effects of PDMS-diol contents on the particle size, thermal and surface properties of WPUD were investigated. The structures of the synthesized WPUD were confirmed using by FT-IR. The surface, thermal and mechanical properties were investigated by measuring the contact angles, DSC, TGA and UTM. As PDMS-diol contents increased, the particle size, the contact angle, and the elongation was increased, while the tensile strength was decreased. Also the thermal stabilities of the synthesised WPUD were increased as PDMS-diol contents increased.

Comparative Toxicity Studies of Ultra-Pure Ag, Au, Co, and Cu Nanoparticles Generated by Laser Ablation in Biocompatible Aqueous Solution

  • Kim, Yea-Seul;Kim, Kuk-Ki;Shin, Seon-Mi;Park, Seung-Min;Hah, Sang-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.10
    • /
    • pp.3265-3268
    • /
    • 2012
  • Nanoparticles (NPs) are increasingly used in consumer products, which have aroused many concerns and debates regarding their fate in biological systems from a point of their safety/toxicity. Although a number of studies on the biological effects of NPs have been published, these are often complicated by the possible toxicity of conventional NPs, caused by contamination with chemical precursors or additives during their synthesis and/or purification procedures. To explicitly understand the toxicity basis of NPs, it is necessary to directly address a main problem related to their intrinsic/inherent toxicity and/or incompatibility with biological objects. The present study is designed to take advantage of a novel laser-assisted method called laser ablation to generate Ag, Au, Co, and Cu NPs in biocompatible aqueous solution, and to evaluate the toxicity of the resulting ultra-pure NPs. Our results show that the ultra-pure NPs with nascent surfaces possess moderate cytotoxicity to human cells in a cell-dependent manner.

Hot stage microscopy and its applications in pharmaceutical characterization

  • Arun Kumar;Pritam Singh;Arun Nanda
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.12.1-12.11
    • /
    • 2020
  • Hot stage microscopy (HSM) is a thermal analysis technique that combines the best properties of thermal analysis and microscopy. HSM is rapidly gaining interest in pharmaceuticals as well as in other fields as a regular characterization technique. In pharmaceuticals HSM is used to support differential scanning calorimetry (DSC) and thermo-gravimetric analysis (TGA) observations and to detect small changes in the sample that may be missed by DSC and TGA during a thermal experiment. Study of various physical and chemical properties such sample morphology, crystalline nature, polymorphism, desolvation, miscibility, melting, solid state transitions and incompatibility between various pharmaceutical compounds can be carried out using HSM. HSM is also widely used to screen cocrystals, excipients and polymers for solid dispersions. With the advancements in research methodologies, it is now possible to use HSM in conjunction with other characterization techniques such as Fourier transform infrared spectroscopy (FTIR), DSC, Raman spectroscopy, scanning electron microscopy (SEM) which may have additional benefits over traditional characterization techniques for rapid and comprehensive solid state characterization.

ENAMEL ADHESION OF LIGHT-AND CHEMICAL-CURED COMPOSITES COUPLED BY TWO STEP SELF-ETCH ADHESIVES (2단계 자가 산부식 접착제와 결합된 광중합과 화학중합 복합레진의 법랑질 접착)

  • Han, Sae-Hee;Kim, Eun-Soung;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.169-179
    • /
    • 2007
  • This study was to compare the microshear bond strength $({\mu}SBS)$ of light- and chemically cured composites to enamel coupled with four 2-step self-etch adhesives and also to evaluate the incompatibility between 2-step self-etch adhesives and chemically cured composite resin. Crown segments of extracted human molars were cut mesiodistally, and a 1 mm thickness of specimen was made. They were assigned to four groups by adhesives used: SE group (Clearfil SE Bond) AdheSE group (AdheSE), Tyrian group (Tyrian SPE/One-Step Plus), and Contax group (Contax) Each adhesive was applied to a cut enamel surface as per the manufacturer's instruction. Light-cured (Filtek Z250) or chemically cured composite (Luxacore Smartmix Dual) was bonded to the enamel of each specimen using a Tygon tube. After storage in distilled water for 24 hours, the bonded specimens were subjected to ${\mu}SBS$ testing with a crosshead speed of 1 mm/minute. The mean ${\mu}SBS$ (n=20 for each group) was statistically compared using two-way ANOVA, Tukey HSD, and t test at 95% level. Also the interface of enamel and composite was evaluated under FE-SEM. The results of this study were as follows ; 1. The ${\mu}SBS$ of the SE Bond group to the enamel was significantly higher than that of the AdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin (p < 0.05). 2. There was not a significant difference among the hdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin. 3. The ${\mu}SBS$ of the light-cured composite resin was significantly higher than that of the chemically cured composite resin when same adhesive was applied to the enamel (p < 0.05). 4. The interface of enamel and all 2-step self-etch adhesives showed close adaptation, and so the incompatibility of the chemically cured composite resin did not show.

Biodegradation and Preparation of Biodegradable Film by using Natural Gums (천연 Gum류를 이용한 생분해성 필름의 제조와 생체분해)

  • Hwang, Sung-Kwy;Kim, Pan-Gyi;Hwang, Seong-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.71-78
    • /
    • 1998
  • Gum is known as natural polymer. Biodegradable films were prepared by solution blend method in the weight ratio of natural gums(Xanthan, Locust bean, Guar) for the purpose of useful bioimplants. The possibility of bioimplants, which prepared from natural gums as a skin substitute was evaluated by measuring biodegradability. This biodegradable films were inserted in the back of rats and their of biodegradability were investigated by hematological change evaluation as a function of time to the biotransformation. Rats implantation test results showed that Guar induced increments of monocyte and basophil after 48 hours of implantation. And Locust bean showed increase of monocyte and neutrophile counts after 48 hours of implantation. And Xanthan induced decrease of monocyte and neutrophile at 24 hours after implantation. Guar and Locust showed high hemoglobin contents and hematocrit after 48 hours of implantation. Guar and Locust induced some suspects of incompatibility in the tissue after 48 hours, but three were little effects to the skin inflammation at 24 hours. These values of biodegradable films, which prepared from prepared from natural gums measured in this were some satisfiable results at short period with those of ideal skin bioimplants.

Compatibilization of Linear PPS/PET Blends with SEBS Copolymers (SEBS 공중합체를 이용한 선형 PPS/PET 블렌드의 상용화)

  • Kim, Sungki;Hong, In-Kwon;Lee, Sangmook
    • Polymer(Korea)
    • /
    • v.37 no.3
    • /
    • pp.405-410
    • /
    • 2013
  • The effect of styrene-ethylene/butylene-styrene (SEBS) on the blend of polyphenylene sulfide (PPS) and polyethylene terephthalate (PET) was investigated. The blends were extruded by a single screw extruder equipped with a Maddock mixing screw, and their molded properties were examined. After the binary blends were prepared on the whole compositions of PPS/PET (80/20, 60/40, 40/60, 20/80), the thermal, rheological, mechanical properties and morphology of the blends were analyzed. The results showed the significant decline in the properties of the blends owing to the incompatibility between PPS and PET phases. As a basic blend composition, the PPS/PET (40/60) blend was selected by considering cost efficiency. To this basic blend, SEBS was added as a compatibilizer. With increasing SEBS addition, the mechanical properties were improved. From the domain size reduction observed in morphology, it might be due to the enhancement of compatibility between linear PPS and PET phases by addition of SEBS.

Studies on the Preparation of Conducting Composite Film by a Vapor Phase in situ Polymerization (전도성 복합필름의 기상중합과 특성에 대한 연구)

  • Park, Jun-Seo;Park, Jang-Woo
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.902-906
    • /
    • 1999
  • Electrically conducting composite films were prepared by a vapor phase in situ polymerization of pyrrole in the methyl cellulose film containing a copper(II) perchlorate. Methylcellulose had high affinity to pyrrole and was used as a matrix polymer. Conducting polypyrrole was embedded in the methylcellulose film forming a conducting network and the conductivity of the composite films ranged $10^{-1}$ to $10^{-7}S/cm$. The conductivities of conducting composite films were dependent on the nature of the matrix polymers, concentration of oxidant and polymerization time. In situ polymerization of pyrrole was observed in the matrix polymer and confirmed by UV-vis spectra. From the results of the thermogravimetric analysis, the chemical oxidative polymerization of pyrrole in the matrix polymers did not give any negative effects on the thermal stability of the composite films. Electron micrograph of composites indicated good penetration of PPy in the matrix polymer. DMA suggested a certain degree of incompatibility of the polypyrrole in the composites.

  • PDF

Cytotoxicity of Ultra-pure TiO2 and ZnO Nanoparticles Generated by Laser Ablation

  • Jeong, Minju;Park, Jeong Min;Lee, Eun Jeong;Cho, Yea Seul;Lee, Chunghyun;Kim, Jeong Moo;Hah, Sang Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3301-3306
    • /
    • 2013
  • This paper aims to address the cellular toxicity of ultra-pure titanium dioxide ($TiO_2$) and zinc oxide (ZnO) nanoparticles (NPs) frequently employed in sunscreens as inorganic physical sun blockers to provide protection against adverse effects of ultraviolet (UV) radiation including UVB (290-320 nm) and UVA (320-400 nm). In consideration that the production and the use of inorganic NPs have aroused many concerns and controversies regarding their safety and toxicity and that microsized $TiO_2$ and ZnO have been increasingly replaced by $TiO_2$ and ZnO NPs (< 100 nm), it is very important to directly investigate a main problem related to the intrinsic/inherent toxicity of these NPs and/or their incompatibility with biological objects. In the present study, we took advantage of the laser-assisted method called laser ablation for generation of $TiO_2$ and ZnO NPs. NPs were prepared through a physical process of irradiating solid targets in liquid phase, enabling verification of the toxicity of ultra-pure NPs with nascent surfaces free from any contamination. Our results show that $TiO_2$ NPs are essentially non-poisonous and ZnO NPs are more toxic than $TiO_2$ NPs based on the cell viability assays.

Synthesis of Fluorine Modified Polyurethane and Surface Modification (불소 변성 폴리우레탄의 합성과 표면 개질)

  • Lim, Chul Hwan;Choi, Hee Sung;Noh, Si Tae
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.913-916
    • /
    • 1999
  • Fluorine modified diisocyanate(FMD) was synthesized from tris(6-isocyanatohexyl)isocyanurate(TIHI) and N-ethyl-N-2-hydroxyethyl-perfluorooctanesulfonamide(HFA). Fluorine modified polyurethane(FMPU) was also synthesized from FMD and poly(tetramethylene) glycol(PTMG). Modified polyurethanes were made by blending FMPU into the polyester type base polyurethane(BPU). Surface and thermal properties of the blended BPU film was measured by contact angle measurement and DSC. As the amounts of FMPU was increased from 0 wt % to 1 wt %, the surface energy was dramatically decreased from 47.82 dyne/cm to 17.64 dyne/cm. But we observed little change of the contact angle with further increase in the amount of the FMPU up to 10 wt %. The data meant that the surface of the blended polyurethanes was hydrophobic due to the surface arrangement of the fluorine containing moiety in FMPU. Phase separation was induced by the incompatibility of FMPU and BPU for the samples having over 5 wt % of FMPU. The thermal analysis data of these samples showed the thermal behavior of the FMPU itself.

  • PDF