• Title/Summary/Keyword: Chemical Reactor

Search Result 1,553, Processing Time 0.037 seconds

Evaluation on the Purification Capacity of Pollutants in the Tidal Flat (갯벌의 오염물질 정화능력 평가)

  • YOU Sun-Jae;KIM Jong-Gu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.4
    • /
    • pp.409-415
    • /
    • 1999
  • To evaluate the purification capacity of pollutants (COD, $PO_4^{3-}-p$, $NO_3^{-}-N$, Cu, Cd, Pb) in the three tidal flats, Eueunri, Gyewhado, Chunjangdae, the experiments were carried out with the batch reactor equipped with artifical tidal flats. Eueunri tidal flat was $98.8\%$ content of silt and clay and Chungjangdae was $97.84\%$ content of sand. The organic matters (I.L., $COD_{sed}$, POC) in Eueunri tidal flat were 2$\~$8 times higher than other tidal flats. The purification capacity of COD was 0.75 kg/ha/12 hr in Eueunri, 0.60 kg/ha/12 hr in Gyewhado and 0.55 kg/ha/12 hr in Chunjangdae. The mean purification capacity of COD in three tidal flats was 1.27 kg/ha/day. The calculated purification capacity of COD was 25.4 ton/day in the disappeared tidal flat areas (20,000 ha) of the Saemangeum reclamation. The purification capacity of phosphorus was 0.21 kg/ha/12 hr in Gyewhado, 0.39 kg/ha/12 hr in Eueunri and 0.22 kg/ha/12hr in Chunjangdae. The nitrate was 0.53, 0.74 and 0.43kg/ha/12hr, respectively. The purification capacity of heavy metals (Cu, Cd, Pb) were 88.9g/ha/12hr, 11.0g/ha/12hr, 1.7g/ha/12hr in Gyewhado, 89.1g/ha/12hr, 18.0g/ha/12hr, 2.6g/ha/12hr in Eueunri and 55.3g/ha/12hr, 18.0g/ha/12hr, 2.1g/ha/12hr in Chunjangdae, respectively. Accordingly, the purification capacity of pollutants in Eueunri tidal flat with high contents of organic matter were higher than other tidal flats. So, the purification capacity of pollutants were affected by physical and/or chemical characteristics of tidal flats.

  • PDF

Large scale enzymatic production of chitooligosaccharides and their biological activities (키토산올리고당의 효소적 대량생산 및 생리활성)

  • Kim, Se-Kwon;Shin, Kyung-Hoon
    • Food Science and Industry
    • /
    • v.53 no.1
    • /
    • pp.2-32
    • /
    • 2020
  • In recent years, significant importance has been given to chitooligosaccharides (COS) due to its potent notable biological applications. COS can be derived from chitosan which is commonly produced by partially hydrolyzed products from crustacean shells. In order to produce COS, there are several approaches including chemical and enzymatic methods which are the two most common choices. In this regard, several new methods were intended to be promoted which use the enzymatic hydrolysis with a lower cost and desired properties. Hence, the dual reactor system has gained more attention than other newly developed technologies. Enzymatic hydrolysis derived COS possesses important biological activities such as anticancer, antioxidant, anti-hypersentive, anti-dementia (Altzheimer's disease), anti-diabeties, anti-allergy, anti-inflammatory, etc. Results strongly suggest that properties of COS can be potential materials for nutraceutical, pharmaceutical, and cosmeceutical product development.

Feasibility Study for the Cleaning of Well Screens using High-voltage Pulsed Discharge (고전압 펄스 방전을 이용한 지하수 관정 스크린 공막힘 재생법 연구)

  • Chung, Kyoung-Jae;Lee, Seok-Geun;Dang, Jeong-Jeung;Choi, Gil-Hwan;Hwang, Y.S.;Kim, Chul-Young;Park, Young-Jun
    • The Journal of Engineering Geology
    • /
    • v.23 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The application of appropriate rehabilitation methods can improve the efficiency of clogged wells and extend their life. In this paper, we study the feasibility of well cleaning using high-voltage pulsed discharge, in which electrical energy is used to produce impulsive pressure in water, in contrast to conventional methods that employ chemical or pneumatic energy sources. This technique utilizes the compressive shock wave generated by the expansive force of hot, dense plasma that is produced during a pulsed discharge in the gap between electrodes immersed in water. Compared with conventional techniques, this method is simple, and easy to handle and control. Using a capacitive pulsed power system with an electrical energy of 200 J, an impulsive pressure of 10.7 MPa is achieved at the position 6 cm away from the discharge gap. The amplitude of the impulsive pressure was easily controlled by adjusting the charging voltage of the capacitor and was almost linearly proportional to peak discharge current. The technique achieved good results in cleaning feasibility tests with mock-up specimens similar to clogged well screens.

Development of Porous Media for Sewage Treatment by Pyrolysis Process of Food Wastes with Loess (음식물 쓰레기 및 황토 혼합물의 열분해를 통한 수질정화용 다공성 담체 개발)

  • Kim, Sang-Bum;Lee, Myong-Hwa;Kim, Yong-Jin;Park, Chul-Hwan;Lee, Jong-Rae;Kim, Gyung-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.289-296
    • /
    • 2007
  • Porous media for sewage treatment were developed through a pyrolysis process of food wastes with loess in the study. This work was carried out in two consecutive stages; in the first stage, new porous media were prepared through a high temperature pyrolysis process, and then the resultant media were applied to a simple lab-scale sewage treatment process in the second stage. To determine the optimum operating conditions of pyrolysis and mixing ratio of materials, physical properties such as specific surface area, porosity and compressive strength of final products were analyzed. The removal efficiencies of TOC and COD were measured to evaluate the effectiveness of resultant porous media. As a result of the experiment, we found that the best mixing ratio of food wastes to loess was 1 : 1 at $1,100^{\circ}C$. Average porosity of the developed media was 37.0%, in which pore size ranged from 1 to $20{\mu}m$, showing quite vigorous microbial activation. After immersing the media into a reactor for sewage treatment for eight days, removal efficiencies of TOC and COD were 87.3% and 85.0%, respectively.

Wastewater Treatment Characteristics by Pseudomonas sp. BLP2052 and Flavobacterium sp. BLP20515 Isolated from Sewage (선별된 Pseudomonas sp. BLP2052와 Flavobacterium sp. BLP20515의 폐하수 처리 특성)

  • 박철환;최광근;임지훈;이상훈;김상용;이진원
    • KSBB Journal
    • /
    • v.14 no.2
    • /
    • pp.153-159
    • /
    • 1999
  • Fifteen microbes have been isolated from Jangja pond in Kuri-Si, Kyeonggi-Do. Among them, two strains showed excellent COD removal from wastewater, which were named Pseudomonas sp. BLP2052 and Flavobacterium sp. BLP20515, respectively. Optimal pH and temperature for the cell growth were 7.0 and $30^{\circ}C$ for both strains. Pseudomonas sp. BLP2052 and Flavobacterium sp. BLP20515 was applied to the reactor to treat wastewater and 66.0% and 65.7% COD (chemical oxygen demand) removal was achieved, respectively. Comparing these results to the case of applying mixed microbes present in Jangja pond, COD removal rate was 15% less. But when adding the selected microbes to the wastewater containing mixed microbes, COD removal rate increased by 5%. After 84 hour operation, we achieved 85.6% COD removal. When inhibitors were added less than 100 ppm, during the microbial wastewater treatment, Fe, Zn, Al, phenol and Cr influenced microbial activity more deterioratively in order. In the case of over 300 pm, Cr, Fe, Zn, Al and phenol showed severe deteriorative effect in order.

  • PDF

Removal of Ethylene Over KMnO4/Silica-alumina: Effect of Synthesis Methods and Reaction Temperatures (KMnO4/실리카-알루미나 상에서 에틸렌 제거: 합성 방법과 반응온도의 영향)

  • Cho, Min-Whee;Yoon, Songhun;Park, Yong-Ki;Choi, Won Choon;Kim, Hee Young;Park, Seungkyu;Lee, Chul Wee
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.407-410
    • /
    • 2009
  • 18~19 wt% $KMnO_4$/$SiO_2-Al_2O_3$ with Si/Al = 1/5 and 1/10, and 20 wt% $KMnO_4$/$Al_2O_3$ were prepared by solvent evaporation method. Catalytic activity of ethylene abatement over those samples were evaluated and compared under the conditions of GHSV $1125h^{-1}$, ethylene gas (ethylene 0.2%, air 99.8%, relative humidity 50%) at 30, 40, 60 and $120^{\circ}C$ using a fixed-bed reactor. $KMnO_4$/$SiO_2-Al_2O_3$ was showed better performance than $KMnO_4$/$Al_2O_3$ by 170~210% at 30, $40^{\circ}C$, and by 60% at 60, $150^{\circ}C$, respectively.

Quantitative Analysis of Ergosterol as a Biomarker of Mold-contaminated Foods Using the Enzyme Biosensor (효소 바이오센서를 이용한 식품의 곰팡이 오염 지표물질인 Ergosterol 정량분석)

  • Kim, Mi-Kyeong;Kim, Jong-Won;Kim, Mee-Ra
    • Korean journal of food and cookery science
    • /
    • v.25 no.2
    • /
    • pp.252-259
    • /
    • 2009
  • Ergosterol is the significant component of the cell wall of fungi. Its presence is regarded as evidence of fungi contamination in grain and other foods. Many studies on ergosterol detection have been carried out using chemical methods, but those methods required complicated pre-treatments and long analysis times. In this study, an amperometric biosensor was developed for fast and precise ergosterol detection. The biosensor system used the electron transfer of hydrogen peroxide produced from the reaction of ergosterol with cholesterol oxidase. The biosensor system consisted of a peristaltic pump, a syringe loading sample injector, an enzyme reactor, a fabricated flow-through cell containing a working electrode, a reference electrode and a counter electrode, and a potentiostat/recorder. The working electrode was prepared by coating modified multi-wall carbon nanotube (MWNT) on glassy carbon electrode. The $MWNT-NH_2$ coated glassy carbon electrode linearly responded to hydrogen peroxide in the range of $1{\times}10^{-5}{\sim}8{\times}10^{-5}$ M with a detection limit of $10^{-7}$ M in the basic performance test. The currents produced from the ergosterol biosensor showed the linearity in a range from $1.0{\times}10^{-6}$ M to $1.0{\times}10^{-5}$ M ergosterol.

A Parametric Study of Pervaporation-facilitated Esterification (전산모델링을 통한 투과증발-촉진 에스테르화 반응에 대한 연구)

  • Yeom, C.K.;Choi, Seung-Hak;Park, You-In;Chang, Sung-Soon
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.146-160
    • /
    • 2007
  • A parametric study on pervaporation-facilitated esterification was performed by using a practical model based on non-perfect separation through membrane which is not perfectly permselective to water. Thus, membrane selectivity as well as membrane capability to remove water should be taken into account in establishing the simulation model to explain how the membrane separation influence the esterification reaction process. It was shown by simulation that in the reaction systems with non-perfect separation, the permeation of reactants which are acid or/and alcohol retards the reaction by inducing the backward reaction so that reaction conversion curve is located between a reaction system coupled with pervaporation process having a perfect permselectivity to water and a reaction system without pervaporation process. The volume change of reaction system occurs as a result of the permeation through the membrane. The reaction volume change which can be characterized by the reaction ratio of $r_{\Psi}\;to\;r_{{\Psi}=1}$ affects reaction kinetics by concentrating reactants and products, respectively, with different extent with time; reactant-concentrating effect is dominant during the initial stage of reaction, resulting in facilitating the reaction, and then product-concentrating effect is exerted more on reaction, causing to slow down the reaction. When pervaporative dehydration is applied to the reaction system plays an important role in the reaction as well. The effect of timing to impose pervaporation on reaction system affected the reaction kinetics in terms of reaction rate and reaction conversion. A relationship was derived to explain membrane unit capacity and reaction parameters that will be used as a design tool to determine membrane unit capacity at a given reaction conditions or reaction parameters at a membrane unit capacity.

Temperature Dependence of the Kinetic Constants in Acidogenesis Process of Anaerobic Digestion (혐기성소화의 산발효과정에 있어서 동역학정수의 온도의존성)

  • Cha, Gi-Cheol;Jeong, Tae-Young;Yoo, Ik-Keun;Kim, Dong-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.839-845
    • /
    • 2007
  • Temperature dependence of kinetic constants in the anaerobic acidogenesis was investigated using anaerobic chemostat-type reactor. Glucose was used as a substrate in this experiment. Temperature ranging from 15 to $30^{\circ}C$ were studied. The saturation constant$(k_s\upsilon)$ and growth yield(Y) decreased with increasing temperature, while the maximum specific substrate utilization rate$(\upsilon_{max})$ increased. A temperature correction factor$(Q_{10})$ values of the substrate utilization rate and bacteria growth rate were the range from 1.3 to 2.2 and 1.5 to 2.2, respectively. The growth yield(Y) for the acidogenesis process was less sensitive to temperature changes than the maximum specific substrate utilization rate$(\upsilon_{max})$. The simulation model of the relationship between the substrate and sludge retention time(SRT) at the temperature range of 20 to $30^{\circ}C$ is obtained as the following ; $1/SRT={(6.53){\cdot}(1.038)^{T-20}{\cdot}(S/X)}/{(1.38){\cdot}(0.983)^{T-20}+(S/X)}$.

A Study on the Method for the Removal of Radioactive Corrosion Produce Using Permanent and Electric Magnets

  • Kong Tae-Young;Song Min-Chul;Lee Kun-Jai
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.113-123
    • /
    • 2005
  • The removal of radioactive corrosion products from the reactor coolant through a magnetic filter system is one of the many approaches being investigated as a means to reduce radiation sources and exposures to the operational and maintenance personnel in a nuclear power plant. Many research activities in water chemistry, therefore, have been performed to provide a filtration system with high reliability and feasibility and are still in process. In this study, it was devised the magnetic filter system with permanent and electric magnets to remove the corrosion products in the coolant stream taking an advantage of the magnetic properties of corrosion particles. Permanent magnets were used for separation of corrosion products and electric magnets were utilized for flocculation of colloidal particles to increase in their size. Experiments using only permanent magnets, in the previous study, displayed the satisfactory outcome of filtering corrosion products and indicated that the removal efficiency was more than 90 $\%$ for above 5 $\mu$m particles. Experiments using electric magnets also showed the good performance of flocculation without chemical agents and exhibited that most corrosion particles were flocculated into larger aggregates about 5 $\mu$m and over in diameter. It is, thus, expected that the magnetic filter system with the arrangement of permanent and electric magnets will be an effective way for the removal of radioactive corrosion products with considerably high removal efficiency.

  • PDF