• Title/Summary/Keyword: Chemical Composition test

Search Result 474, Processing Time 0.021 seconds

NIR - a Tool for Evaluation of Milling Procedure

  • Gergely, Sziveszter;Handzel, Lidia;Zoltan, Andrea;Salgo, Andras
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1125-1125
    • /
    • 2001
  • Micro-scale test methods are producing small-sample size where the conventional physical and chemical tests can not be used (high standard deviation, uncertain sampling conditions, low repeatability). Different small-scale test methods were developed recently for determination of physico-chemical, functional, rheological properties of wheat or wheat dough using miniaturized instruments with sophisticated sample preparation/handling and mechanics (RVA, 2 g mixograph, micro-Z-arm mixer, small-scale noodle maker, micro-baking method etc.). The small-scale methodologies can be used as basic research tools or as technology supported measurements and can be also essential in the early selection for quality traits in breeding programs. The milling as a sample preparation step is essential procedure providing good quality flour or semolina samples from small amount of grain (5-10 g) in a reproducible and reliable way. The aim of present study was to use NIR as quality control tool, and to evaluate the recently developed and manufactured micro-scale lab mill (FQC-2000) produced by Inter-Labor Co. Ltd., Hungary. The milling characteristics of the new instrument were compared to other laboratory mills and the effects of milling action on the chemical composition of fractions were analysed. The fractions were tested with both chemical and near infrared spectroscopic methods. The micro-scale milling resulted significantly different yields, particle size distributions and different fractions from compositional point of view. The near infrared spectra were sensitive enough to distinguish the fractions obtained by different milling procedures. Quantitative NIR calibration equations were developed and tested in order to measure the chemical composition of characteristic milling fractions. Special qualification procedure the PQS (Polar Qualification System) method was used for detecting the differences between fractions obtained by macro and micro-milling procedures. The results and the limitations of PQS method in this application will be discussed.

  • PDF

Performance and Reliability Issues of Flip Chip Joints

  • Lee Taek-Yeong
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2004.09a
    • /
    • pp.165-180
    • /
    • 2004
  • Phosphor contents are critical to the interfacial reaction and IMC behavior. - If content is too low, the dissolution rate will be very fast. - If content is too much, the cracks during interfacial reaction and the IMCs spalling will easily occur. The spalling of IMCs caused the brittle fracture of solder joint under shear test. IMCs from chemical reaction influences to the mechanical properties and life time. Composition changes from chemical reaction influence to the life time.

  • PDF

A Fundamental Study on the Pyrometallurgical Debismuthizing of Lead (粗鉛의 乾式 脫蒼鉛에 관한 基礎的 硏究)

  • Koh, Chang-Shik
    • Journal of the Korean Chemical Society
    • /
    • v.6 no.2
    • /
    • pp.143-147
    • /
    • 1962
  • As a part of "the Fundamental Study of Pyrometallurgical Debismuthizing of Lead", the author has studied liquid Pb-Bi, Pb-Na, Bi-Na binaries and Pb-Bi-Na ternary including Pb rich side composition which forms a basis of the Dittmer method. In this study, debismuthizing mechanism of the Dittmer method pertaining to the lead rich corner of the system studied was classified by the results of thermal analysis, solubility determination of Bi and Na in liquid Pb and debismuthizing test by adding metallic sodium. For instance eutectic trough in lead rich corner of Pb-Bi-Na ternary relating to the Dittmer method was determined.

  • PDF

Sensory Evaluations of the Muffins with Mulberry Leaf Powder and Their Chemical Characteristics (뽕잎머핀에 대한 관능평가 및 이화학적 특성)

  • Ahn Chang-Soon;Yuh Chung-Suk
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.14 no.6
    • /
    • pp.576-581
    • /
    • 2004
  • This study was carried out to evaluate the sensory evaluation of the muffins with mulberry leaf powder as well as their chemical characteristics. The muffins were prepared by adding 0%, 1 %, 2% and 3% mulberry leaf powder to the recipe. As a result of the sensory evaluations, the color, flavor and texture of the muffins of 2% mulberry leaf powder were found to be much better than those of the other groups. In the chemical composition analysis, increasing the mulberry leaf powder led to a significant increase in the content of crude protein, moisture and crude ash, while crude fat was significantly decreased. As the ratio of mulberry leaf powder increased, Ca, Mg, Fe and Zn in the muffins increased proportionally (p<0.05). The lightness value, the redness value and the yellowness value decreased with the increase of mulberry leaves powder content. In a texture analyser test, hardness and cohesiveness decreased as the ratio of mulberry leaf powder increased. The adhesiveness of the muffins with 2% mulberry leaf powder was the strongest of all.

  • PDF

A Study on the Nutritional Characteristics of Ostrich Extracts Added with Medicinal Herbs (한방재료를 첨가한 타조 추출액의 영양학적 특성에 관한 연구)

  • 김애정;여정숙;장준혁;우경자;김혜진
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.12 no.3
    • /
    • pp.218-224
    • /
    • 2002
  • This study was undertaken to analyze chemical composition, macro- and micro-mineral contents of ostrich bone with flesh meat (BF), ostrich bone with flesh meat with herb medicine (BFll) and ostrich bone with internal organs (BI). Crude fat of the BFH was lower, but crude protein and crude ash of the BFH were significantly higher than those of the BF and the BI. Among the minerals, Ca, p, Mg, Fe, Cu, Zn content of the BFH were significantly higher than the content in the BF and the BI. The minerals, Pb, Cd and As were not detected in ostrich and herb medicine extracts. From the sensory test of ostrich and herb medicine, the preferences were in the fellowing order; ostrich bone with flesh meat with herb medicine (BFH), ostrich bone with flesh meat (BF), and ostrich bone with internal organs (BI) in extracts.

  • PDF

The Study of the Basic Physical Properties in the Concrete Used Aggregates with the Different Mineralogical Features (골재의 암석학적 특징이 콘크리트 기본특성에 미치는 영향)

  • 엄태선;최상흘
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.1-9
    • /
    • 1996
  • The aggregates with the different mineralogical features are studied how to affect the basic physical properties of concretes according to the changes of the chemical composition, mineralogical composition, crystal size, the standard qualities in the aggregates in using chemical analysis, X.R.D. DT-TGA, polarized light microscope, streoscopic microscope, standard test method of aggregates & concretes. At this studies, we found that aggregates without the seathered mineral such as muscovite & kaolin mineral etc, is superior to the others with the weathered mineral, even if it's standard qualities are inferiored to the other's. For examples, in manufacturing high strength concretes. The strength of concretes used aggregates without weathered mineral are improved about 15% than the other's and also. For general mixture to manufacture remicon, more about 10-20% than the other's strength and workability.

  • PDF

Failure Investigation of Fire-Side Water-Wall Tube Boiler

  • Fatah, M.C.;Agustiadi, D.;Pramono, A.W.
    • Corrosion Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.242-248
    • /
    • 2021
  • Unforeseen failures of boilers in power plants may affect the continuation of electricity generation. Main failures in boilers are influenced by the tube material, tube position, boiler service temperature and pressure, and chemical composition of the feed water and coal. This investigation was intended to find answers on the causes and mechanism of failure of the fire-side boiler water-wall tubes, due to perforation and corrosion. The tube conformed to the material requirements in terms of its chemical composition and hardness. Microscopic examination showed ferrite and pearlite indicating no changes in its microstructure due to the temperature variation. SEM test showed a single layer and homogenous film density particularly on the area far from perforation. However, layers of corrosion product were formed on the nearby perforation area. EDX showed that there were Na, Ca, S, and O elements on the failed surface. XRD indicated the presence of Fe2O3 oxide. The failure mechanism was identified as a result of significant localized wall thinning of the boiler water wall-tube due to oxidation.

A COMPARATIVE STUDY ON THE CHEMICAL COMPOSITION AND MECHANICAL PROPERTIES OF FOUR LOW-GOLD-CONTENT DENTAL CASTING ALLOYS MANUFACTURED IN KOREA (한국산(韓國産) 치과주조용(齒科鑄造用) 저금함유합금(低金含有合金)의 조성(組成) 및 기계적(機械的) 성질(性質)에 관(關)한 비교연구(比較硏究))

  • Chang, Ik-Tae;Yang, Jae-Ho;Kim, Chang-Whe;Kim, Kwang-Nam;Lee, Sun-Hyung;Kim, Yung-Soo;Chang, Wan-Shik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.17-27
    • /
    • 1981
  • This study was conducted to determine the chemical composition and the mechanical properties of four commercially available low gold-based crown and bridge alloy produced in Korea. Four dental casting gold-silver-palladium alloys, i.e., A, B, C and D (code of alloys) were selected for the evaluation of chemical composition, ultimate tensile strength, elongation. values and Vickers hardness. The chemical composition of test specimens was analyzed by both emission spectrography and wet gravitation method with a 1.5gm of low gold ingot. The tensile properties and Vickers hardness was determined with cast specimens treated in following three conditions; as-cast, softening heat treatment and hardening heat treatment. The tensile testing bars were cast in accordance with the model designed by Gettleman and Harrison (1969) which was modified from the A. D. A. Specification No. 14 for dental chromium-cobalt casting alloy. Nine tensile test specimens were made from a split silicone mold for each of the test alloys to the size of 2.5mm in diameter and a gauge length of 10mm. All four alloys were handled in accordance with conventional methods used in Type III gold alloys. Ultimate tensile strength and elongation were measured on an Instron Universal Tensile Testing Machine (Model 1125, Japan) operated at a crosshead rate of 0.1cm/min. Elongation values were measured using Digital Measuring Microscope (MS-152, FUSOH, Japan). Vickers hardness was determined with a Vickers Hardness Tester (Model VKH-l, Japan) at a 1.0kg load on a mounted tensile test specimen. The following results were obtained from this study; 1. All tested alloys were composed of Au, Ag, Pd, Cu, Zn and Fe in common. The composition rate of gold for all four alloys was found in the range of $42{\sim}47$ weight % as shown below. Alloy A; Au 45%, Ag 40.2%, Pd 5.76%, others 9.04%. Alloy B; Au 47.1%, Ag 29.03%, Pd 6.98%, others 16.92%. Alloy C; Au 45%, .Ag 26.9%, Pd 6.83%, others 21.07%. Alloy D; Au 41.8%, Ag 34.4%, Pd 6.95%, others 16.85%. 3. The ultimate tensile strength of the four alloys was in the range of $31{\sim}82kg/mm^2$. The test results were shown in the below order from the highest value; As-cast condition; D, B, C, A. Softening heat treament; B, C, D, A. Hardening heat treatment; D, B, C, A. 4. The test :results of the elongation rate for each alloy were in the range of $0.5{\sim}18%$. The test results were shown in the below order from the highest value; As-cast condition; A, D, B, C. Softening heat treatment; A, C, D, B. Hardening heat treatment; C, D, B, A. 5. Vickers hardness for each of the four alloys was in the range of $120{\sim}230$. The test results were shown in the below order from the highest value; As-cast condition; C, B, D, A Softening heat treatment; D, B, C, A. Hardening heat treatment; D, A, C, B. 6. There were no differences in the physical properties between as-cast condition and softening heat treatment.

  • PDF

A Study on the Performance Appraisal for Copper Sheet as Root Barrier Material Appling to Green Roof System (옥상녹화 및 인공지반녹화용 구리시트 방근재의 성능평가에 관한 연구)

  • Cho, Il-Kyu;Kwon, Shi-Won;Kwak, Kyu-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.5-8
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we examine the practical use of copper sheet considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, sire of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

  • PDF

A Study on Failures by Abnormal AlxOy Layer after PCT (PCT 후 비정상 AlxOy 층 형성에 의해 발생된 불량 연구)

  • Choi, Chae-Hyoung;Choi, Deuk-Sung;Jeong, Seung-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.231-237
    • /
    • 2014
  • In this paper, we have proceeded research for failures of semiconductor device stressed by Pressure Cooker Test(PCT). After PCT stress, we found various failures such as delamination between aluminium line and device layers and chemical composition transition of aluminium. We have executed the analysis using the physical and chemical observation equipments. There were the main failures that aluminium loss of aluminium pad is occurred and $Al_xO_y$($Al_2O_3$ or $Al(OH)_3$)) layer is formed abnormally. The primary cause of the failures is reaction of supplied fluorine or chlorine gases and infiltrated moisture during etching process.