• Title/Summary/Keyword: Chelate resin

Search Result 21, Processing Time 0.025 seconds

Studies on Preparation of Resion-Metal Chelates and Its Catalytic Activity for the Oxidation of Hydroxy Compounds and l-Ascorbic Acid (Resin-Metal Chelate의 제조와 Hydroxy화합물 및 l-Ascorbic Acid의 산화 촉매효과에 관한 연구)

  • Whang Kyu-Ja;Lee Young Sun;Kim Young Mi;Lee Yong-Keun
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.113-119
    • /
    • 1989
  • Chelating resins containing hydrazide or triethylenetetramine side chain were prepared using a commercial cation exchage resin, Diaion WK 11, and their nitrogen contents were determined by elemental analysis. The synthesized resin, and commercial chelating resins, (Diaion-CR 10 and-CR 20) were treated with various metal chelates of which metal contents were subsequently determined by chelatometry. Sectioned beads of the resin-metal chelates were also observed using electron microprobs X-ray analyzer. To examine the catalytic activity of the resin-metal chelates, they were applied to the oxidation of various hydroxy compounds and l-ascorbic acid, and found to be effective catalysts.

  • PDF

A Quantitative Resolution of Overlapped Chromatographic Fractions by Target Transformation Factor Analysis

  • Ihn Chong Lee;Seungwon Kim;Chul Lee;Sang Won Choi
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.3
    • /
    • pp.304-309
    • /
    • 1991
  • Target transformation factor analysis is applied to analyze the components of unresolved fraction in the elution curve of La, Pr and Gd which is obtained using the chelate agent- impregnated resin and 0.7 M hydrochloric acid as an eluent. We determined the number of components contributing to the unresolved fractions and verified the presence of suspected components.

Synthesis and Characterization of Chelating Resins Containing Thiol Croups (티올기를 함유하는 킬레이트 수지의 합성 및 특성)

  • 박인환;방영길;김경만;주혁종
    • Polymer(Korea)
    • /
    • v.27 no.4
    • /
    • pp.330-339
    • /
    • 2003
  • Three kinds of macro-reticular bead-typed chelating resins having thiol groups were obtained from basic resins like poly(strene-co-divinylbenzene) (PSD) and poly(styrene-co-methyl methacrylate-co-divinylbenzene) (PSMD): the chelating resin (I) was prepared by chloromethylation of phenyl rings of PSD followed by thiolation using thiourea. The chelating resin (ll) was designed to provide enough space to chelate heavy metal ions; one chloromethyl group was obtained by chlorination of hydroxymethyl group provided by reduction of carboxylic ester group of PSMD and another chloromethyl group was obtained by direct chloromethylation of pendent phenyl group using chloromethyl methyl ether. Both of chloromethyl groups were thiolated by using thiourea. The chelating resin (III) was prepared by chlorosulfonation of phenyl rings of PSD followed by thiolation using sodium hydrosulfide. The adsorbtivity toward heavy metal ions was evaluated. The hydrophobic chelating resin (I) with thiol groups showed highly selective adsorption capacity f3r mercury ions. However, the chelating resin (II) with thiol groups showed mere effective adsorption capacity toward mercury ions than chelating resin (I) with thiol groups, and showed some adsorption capacity for other heavy metal ions like Cu$\^$2+/, Pb$\^$2+/, Cd$\^$2+/ and Cr$\^$3+/. On the other hand, the chelating resin (III) which have hydrophilic thiosulfonic acid groups was found to be effective adsorbents for some heavy metal ions such as Hg$\^$2+/, Cu$\^$2+/, Ni$\^$2+/, Co$\^$2+/, Cr$\^$3+/ and especially Cd$\^$2+/ and Pb$\^$2+/.

A Study on the Synthesis and Characterization of Chelate Resin for Removal of Heavy Metal Ions: 1. (중금속이온 흡착분리를 위한 킬레이트수지의 합성과 특성에 관한 연구 : 1.)

  • 신대윤;육경창;이내택
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.106-116
    • /
    • 1992
  • In order to examine the influences of diluent, DVB, and ligand content, in the adsorption velocities and capacities of chelating resins to heaw metal ions, the chelating resins containing the PO$_3$H, amide, and PO$_3$H+amide were prepared from AN-STR-DVB copolymer. The adsorption capacities of chelating resins were measured by ICP-AES. The major results of the studies are as follows: The optimized compositions of the chelating resins having the highest adsorptivity for the heavy metal ions were found to be DVB=7 wt%, toluene= 100 vol%. The adsorption rate of the chelating resins to the heaw metal ions was PO$_3$H > PO$_3$H+Amide > Amide in order.

  • PDF

A study on the removal of As, Sb, Bi from the copper sulfate solutions by Ion exchange resin containing Aminophosphosphonic acid as a functional group (황산동용액(黃酸銅溶液)에서 Aminophosphosphonic acid 관능기를 가진 이온교환수지에 의한 As, Sb, Bi 제거(除去)에 관한 연구(硏究))

  • Ahn, Jae-Woo;Seo, Jae-Seong
    • Resources Recycling
    • /
    • v.21 no.5
    • /
    • pp.50-57
    • /
    • 2012
  • A comparative study has been carried out on the removal of impurities such As, Sb, Bi from the copper sulfate solution by ion exchange resin containing aminophosphosphonic acid as functional group. The various parameters which affect the removal of impurities; such as the reaction temperature, the reaction time, the amount of ion-exchange resins, the concentration of sulfuric acid in electrolyte, were studied. The basic experimental results showed that about 88% of Sb & 94% of Bi can be adsorbed in these chelate resins and removed from the copper sulfate solutions but As was removed below 10% from the solutions. And the selective elution of Bi and Sb from the adsorbed ion exchange resin also can be achieved by $H_2SO_4$ or HCl solutions. The results also showed that 98.1% of Sb and 96.6% of Bi can be adsorbed from the copper sulfate solutions after 2 Bed-volume of continuous ion exchange column test.

Spectrophotometric Determination of Iron with 2-Hydroxybenzaldehyde-5-nitro-pyridylhydrazone after Separation with Amberlite XAD-7 Nonionic Resin (Amberlite XAD-7 비이온성 수지로 분리 후 2-Hydroxybenzaldehyde-5-nitro-pyridylhydrazone을 이용한 철의 분광학적 정량)

  • Park, Chan Il;Chung, Byung Doo;Jung, Duck Chae;Cha, Ki Won
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.5
    • /
    • pp.522-526
    • /
    • 1999
  • 2-Hydroxybenzaldehyde-5-nitro-pyridylhydrazone (2HB-5NPH) was synthesized and its application to the spectrophotometric determination of iron was studied. The reagent reacts with iron in the pH range 6.0-7.5 to form a yellow coIored 1:2 chelate which is very stable in methanol solution. Beer's law is obeyed in the concentration range 0.05∼2.0 ${\mu}gmL^{-1}$ iron and separation procedure using a short column filled with Amberlite XAD-7 nonionic chelating resin is proposed for the spectrophotometric determination of traces of iron. The influence of several ions as interference was discussed. The separation of Fe(III) ion from the mix-ture solution were carried out with the buffer solution (pH 5.0) and 0.25M HCl as eluents.

  • PDF

Preparation and Luminescence Properties of $Y_{2-x}Gd_xO_3:Eu$ Phosphors by Pechini Method (페치니법에 의한 $Y_{2-x}Gd_xO_3:Eu$ 형광체의 제조와 발광 특성)

  • Lee, Dong-Kyu;Lee, Jin-Hwa;Ahn, Byung-Chul;Jun, Sang-Bae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.207-214
    • /
    • 2006
  • $Y_{2-x}Gd_xO_3:Eu$, phosphors for plasma display panel(PDP), were prepared by Pechini method which use yttriun chloride, gadolinium chloride, and europium oxide as starting materials. This method is a different way to the synthesis of europium(Eu)-doped phosphors, and it consists of the formation of a polymeric resin obtained by polyesterification between metal chelate compounds and a polyfunctional alcohol. This needs lower temperature than solid-state synthetic method. The prepared $Y_{2-x}Gd_xO_3:Eu$ phosphor particles had spherical shape and coherence. The luminescence intensity of $Y_{2-x}Gd_xO_3:Eu$ phosphor particles increased according to the increase of gadolinium(Gd) content(to 0.8mol%), and $Y_{1.2}Gd_{0.8}O_3:Eu$ phosphors had the highest luminescence intensity under vacuum ultra violet(VUV) excitation. The optimum concentration of Eu in the phosphor and optimum calcination temperature was 3wt% and $1100^{\circ}C$. The prepared phosphors were consist of particle, and its size was between 100nm and 150nm. Among the different polyfunctional alcohols, diethylene glycol(DEG) improved the luminescence intensities of phosphors more than other additives. The Pechini method proved that it is demonstrated to be suitable for the synthesis of phosphors used in PDP.

Separation and Recovery of Ce, Nd and V from Spent FCC Catalyst (FCC 폐촉매로부터 Ce, Nd 및 V의 분리 회수 프로세스)

  • Jeon, Sung Kyun;Yang, Jong Gyu;Kim, Jong Hwa;Lee, Sung Sik
    • Applied Chemistry for Engineering
    • /
    • v.8 no.4
    • /
    • pp.679-684
    • /
    • 1997
  • The major constituents in spent FCC catalysts are Si, Al, Fe, Ti, alkali metals and some others. The spent catalyst is also composed small amounts of rare metals such as Ce, Nd, Ni and V. The selective adsorption and concentration of Ce and Nd from the leaching solution of spent FCC catalysts with sulfuric acid($0.25mol/dm^3$) were carried out by the column method with a chelate resin having a functional group of aminophosphoric acid type. Ce and Nd were separated from eluate liquor containing Al, Nd and V by the precipitation process with oxalic acid. Vanadium is purified from chloride ion coexistance by solvent extraction, employing tri-n-octyl phosphine oxide as extractant with Al in the raffinate solution. Rare metals with the purity of 99 percent were obtained from the spent FCC catalyst.

  • PDF

Synthesis and Analytical Application of Chelating Resins Containing Polyamines (폴리아민류를 작용기로 하는 킬레이트수지의 합성 및 분석적 응용)

  • Kim Sun Deuk;Park Jung Eun;Park Myon Yong
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.652-660
    • /
    • 1992
  • The polyamine resins were synthesized by reacting amines such as diethylenetriamine(dien), triethylenetetramine(trien), tetraethylenepentamine(tetren), and pentaethylenehexamine(penten). Stepwise dissociation constants of amines, enthalpy and free energy of metal chelate were determined. Formation constants $(log k_1) of metal chelates were in order of Cu(Ⅱ) > Ni(Ⅱ) > Cd(Ⅱ) > Zn(Ⅱ) > Co(Ⅱ) and tendency of stabilities were proportional to nitrogen numbers of ligand such as dien < trien < tetren > penten. Elutional selectivites of metal ions on resin were agreed to formation constants of metal chelates. {\Delta}H and {\Delta}G were calculated by Van't Hoff equation. Stability constants (log k1) of metalic complexes were in order Cu(Ⅱ) > Ni(Ⅱ) > Cd(Ⅱ) > Zn(Ⅱ) > Co(Ⅱ), and tendency of stabilities were {\circledP}_L-Dien < {\circledP}_L-Trien < {\circledP}_L-Tetren < {\circledP}_L-Penten. The elutional selectivities of metal ions were agreed to stability constants of metal chelates.

  • PDF

Studies on the analysis of phytin by the Chelatometric method (Chelate 법(法)에 의(依)한 Phytin 분석(分析)에 관(關)한 연구(硏究))

  • Shin, Jai-Doo
    • Applied Biological Chemistry
    • /
    • v.10
    • /
    • pp.1-13
    • /
    • 1968
  • Phytin is a salt(mainly calcium and magnesium) of phytic acid and its purity and molecular formula can be determined by assaying the contents of phosporus, calcium and magnesium in phytin. In order to devise a new method for the quantitative analysis of the three elements in phytin, the chelatometric method was developed as follows: 1) As the pretreatment for phytin analysis, it was ashfied st $550{\sim}600^{\circ}C$ in the presence of concentrated nitric acid. This dry process is more accurate than the wet process. 2) Phosphorus, calcium and megnesium were analyzed by the conventional and the new method described here, for the phytin sample decomposed by the dry process. The ashfied phytin solution in hydrochloric acid was partitioned into cation and anion fractions by means of a ration exchange resin. A portion of the ration fraction was adjusted to pH 7.0, followed by readjustment to pH 10 and titrated with standard EDTA solution using the BT [Eriochrome black T] indicator to obtain the combined value of calcium and magnesium. Another portion of the ration fraction was made to pH 7.0, and a small volume of standard EDTA solution was added to it. pH was adjusted to $12{\sim}13$ with 8 N KOH and it was titrate by a standard EDTA solution in the presence of N-N[2-Hydroxy-1-(2-hydroxy-4-sulfo-1-naphytate)-3-naphthoic acid] diluted powder indicator in order to obtain the calcium content. Magnesium content was calculated from the difference between the two values. From the anion fraction the magnesium ammonium phosphate precipitate was obtained. The precipitate was dissolved in hydrochloric acid, and a standard EDTA solution was added to it. The solution was adjusted to pH 7.0 and then readjusted to pH 10.0 by a buffer solution and titrated with a standard magnesium sulfate solution in the presence of BT indicator to obtain the phosphorus content. The analytical data for phosphorus, calcium and magnesium were 98.9%, 97.1% and 99.1% respectively, in reference to the theoretical values for the formula $C_6H_6O_{24}P_6Mg_4CaNa_2{\cdot}5H_2O$. Statical analysis indicated a good coincidence of the theoretical and experimental values. On the other hand, the observed values for the three elements by the conventional method were 92.4%, 86.8% and 93.8%, respectively, revealing a remarkable difference from the theoretical. 3) When sodium phytate was admixed with starch and subjected to the analysis of phosphorus, calcium and magnesium by the chelatometric method, their recovery was almost 100% 4) In order to confirm the accuracy of this method, phytic acid was reacted with calcium chloride and magnesium chloride in the molar ratio of phytic: calcium chloride: magnesium chloride=1 : 5 : 20 to obtain sodium phytate containing one calcium atom and four magnesium atoms per molecule of sodium phytate. The analytical data for phosporus, calcium and magnesium were coincident with those as determine d by the aforementioned method. The new method employing the dry process, ion exchange resin and chelatometric assay of phosphorus, calcium and magnesium is considered accurate and rapid for the determination of phytin.

  • PDF