• 제목/요약/키워드: Check-Valve

검색결과 210건 처리시간 0.021초

발전소용 Y형 체크밸브에 관한 수치해석 연구 (Numerical Analysis of Y-shaped Check Valve for Power Plant)

  • 이재훈;김시범;전락원;이근호
    • 한국기계가공학회지
    • /
    • 제15권1호
    • /
    • pp.129-135
    • /
    • 2016
  • Various type of valves are manufactured for different industrial uses. Among them, check valves are used to allow fluid to flow in one direction but not in the opposite direction. There are many different types of check valves, but Y-shaped check valves are widely used these days. Not many studies have been carried out on Y-shaped check valves and the flow coefficients obtained through numerical analysis have the problem of low reliability. In order to solve this problem, this study performed flow analysis, flow-structure coupled analysis, and flow coefficient measurement experimentally, and through these analyses derived and verified the flow coefficients and assessed the structural safety based on numerical analysis.

Polymer MEMS 공정을 이용한 의료용 미세 부품 성형 기술 개발 (Development of micro check valve with polymer MEMS process for medical cerebrospinal fluid (CSF) shunt system)

  • 장준근;박찬영;정석;김중경;박훈재;나경환;조남선;한동철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.1051-1054
    • /
    • 2000
  • We developed the micro CSF (celebrospinal fluid) shunt valve with surface and bulk micromachining technology in polymer MEMS. This micro CSF shunt valve was formed with four micro check valves to have a membrane connected to the anchor with the four bridges. The up-down movement of the membrane made the CSF on & off and the valve characteristic such as open pressure was controlled by the thickness and shape of the bridge and the membrane. The membrane, anchor and bridge layer were made of the $O_2$ RIE (reactive ion etching) patterned Parylene thin film to be about 5~10 microns in thickness on the silicon wafer. The dimension of the rectangular nozzle is 0.2*0.2 $\textrm{mm}^2$ and the membrane 0.45 mm in diameter. The bridge width is designed variously from 0.04 mm to 0.12 mm to control the valve characteristics. To protect the membrane and bridge in the CSF flow, we developed the packaging system for the CSF micro shunt valve with the deep RIE of the silicon wafer. Using this package, we can control the gap size between the membrane and the nozzle, and protect the bridge not to be broken in the flow. The total dimension of the assembled system is 2.5*2.5 $\textrm{mm}^2$ in square, 0.8 mm in height. We could precisely control the burst pressure and low rate of the valve varing the design parameters, and develop the whole CSF shunt system using this polymer MEMS fabricated CSF shunt valve.

  • PDF

Cause Analysis of Flow Accelerated Corrosion and Erosion-Corrosion Cases in Korea Nuclear Power Plants

  • Lee, Y.S.;Lee, S.H.;Hwang, K.M.
    • Corrosion Science and Technology
    • /
    • 제15권4호
    • /
    • pp.182-188
    • /
    • 2016
  • Significant piping wall thinning caused by Flow-Accelerated Corrosion (FAC) and Erosion-Corrosion (EC) continues to occur, even after the Mihama Power Station unit 3 secondary pipe rupture in 2004, in which workers were seriously injured or died. Nuclear power plants in many countries have experienced FAC and EC-related cases in steam cycle piping systems. Korea has also experienced piping wall thinning cases including thinning in the downstream straight pipe of a check valve in a feedwater pump line, the downstream elbow of a control valve in a feedwater flow control line, and failure of the straight pipe downstream of an orifice in an auxiliary steam return line. Cause analyses were performed by reviewing thickness data using Ultrasonic Techniques (UT) and, Scanning Electron Microscope (SEM) images for the failed pipe, and numerical simulation results for FAC and EC cases in Korea Nuclear Power Plants. It was concluded that the main cause of wall thinning for the downstream pipe of a check valve is FAC caused by water vortex flow due to the internal flow shape of a check valve, the main cause of wall thinning for the downstream elbow of a control valve is FAC caused by a thickness difference with the upstream pipe, and the main cause of wall thinning for the downstream pipe of an orifice is FAC and EC caused by liquid droplets and vortex flow. In order to investigate more cases, additional analyses were performed with the review of a lot of thickness data for inspected pipes. The results showed that pipe wall thinning was also affected by the operating condition of upstream equipment. Management of FAC and EC based on these cases will focus on the downstream piping of abnormal or unusual operated equipment.

제품 검사 시스템 개발에 관한 연구 (A Study on development of repeat check system for product)

  • 최영규
    • 한국정보전자통신기술학회논문지
    • /
    • 제6권3호
    • /
    • pp.156-161
    • /
    • 2013
  • 가스 밸브 제어기는 사용자의 취급부주의에 의해 폭발, 화재 및 질식 등의 사고를 미연에 방지하고자 사용 시간을 설정하여 가스를 사용할 수 있는 시스템이다. 가스 밸브는 각 수용가에서 한 번 설치를 하면 특별한 사안이 없는 한 교체하지 않는 품목 중의 하나로서, 설치 이전에 충분한 시험이 필요한 장치이다. 본 연구에서는 가스 밸브 제어기를 사용 횟수를 설정하여 시험할 수 있는 시스템을 개발하였다.

ER 유체로 작동되는 벨브의 제작 및 성능실험 (Design and Performance Test of Valve Operated by ER Fluids)

  • 장성철;염만오
    • 한국공작기계학회논문집
    • /
    • 제13권1호
    • /
    • pp.63-68
    • /
    • 2004
  • Recently ER fluids are put to practical use in fluid power industry field. As only with electrical signal change to the valve in which ER fluid flowing, ER fluid flow is controlled, so devepment of simple ER valves have been tried. In this case a technical problem is to check the pressure drop caused from flow rate change in valves because the pressure drop is very small. In this study ER valves are designed and manufactured, and small pressure drop induced from flow rate change is checked by pressure transducer which is made with appling strain gage. The ER valves and pressure drop check method are considered to be applied to the fluid power industry.

래크바형 수문권양기에 적용된 정유압장치의 컴퓨터 시뮬레이션에 의한 작동특성 연구 (Computer Simulation Study of the Hydrostatic Transmission Applied to the Rack-Bar Type Sluice Gate)

  • 이성래
    • 유공압시스템학회논문집
    • /
    • 제6권2호
    • /
    • pp.14-21
    • /
    • 2009
  • The typical hydraulic hoisting system of the rack-bar type sluice gate is composed of a hydraulic supply unit using an uni-directional pump, a direction control valve, a hydraulic motor, a counter balance valve, and flow control valves. Here, the hydrostatic transmission is applied to the hoisting system of rack-bar type sluice gate to simplify the operation of gate such that the upward and downward direction of gate is simply controlled by the direction of pump rotation. The new hydraulic hoisting system is composed of a bi-directional pump, a hydraulic motor, two counter balance valves, two check valves, two pilot-operated check valves, two relief valves and a shuttle valve. The characteristics of a suggested system are analyzed by computer simulations.

  • PDF

항공우주용 소형 포펫 체크밸브 기술 동향 (Technology Trend of Small Poppet Type Check Valve for Aerospace Application)

  • 유재한;이수용
    • 항공우주산업기술동향
    • /
    • 제9권1호
    • /
    • pp.158-164
    • /
    • 2011
  • 항공우주용으로 개발되거나 활용 가능한 상업용 체크밸브사례가 조사되었다. 개발사례로 발사체용, 높은 수명이 요구되는 NASA의 SSME (Space Shuttle Main Engine) 및 지상 지원 시스템 퍼지 라인용과 국내에서 개발된 체크밸브가 있다. 상용품은 미국 주요 밸브개발업체의 제품을 상온용과 극저온용으로 분류하여 조사하였다. 또한 운용 온도, 운용 압력 및 크래킹 압력과 같은 주요 성능과 관련된 씰의 재질, 스프링 강성과 같은 설계 인자의 관계도 설명되었다. 이러한 단품 성능 이외에 채터 및 오염과 같은 운용상의 문제점과 일반적인 해결방안도 언급되었다. 또한 기타주의사항으로 필터, 피팅과 청정도 요구조건에 대하여도 조사되었다

  • PDF

피동형 원자로의 Hydraulic Valve 특성 실험 (The Characteristics of Hydraulic Valve for a Passive Reactor)

  • 김상녕;김융석
    • 대한기계학회논문집B
    • /
    • 제22권8호
    • /
    • pp.1083-1090
    • /
    • 1998
  • A kind of three-way check valve, so called hydraulic calve was proposed for the substitute of the density lock of passive reactor such as SPWR (System-Integrated Pressurized Water Reactor). The function of the valve are the separation of the borated water from main coolant loop for normal operation and the insurge of the water into the loop for shutdown and the removal of the decay power when the main coolant flow rate is not enough. To verify the operability and the characteristics of the valve, experimental works were executed with 1/3 scale model calve. Also a diffuser model was proposed for the theoretical analysis of the valve.

수소 충전소용 초고압 볼밸브 설계에 관한 연구 (A Study on Design of Ultra-High-Pressure Ball Valve for Hydrogen Station)

  • 최지아;지상원;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권3호
    • /
    • pp.23-29
    • /
    • 2021
  • Hydrogen energy is the clean energy source of the future. Ultra-high-pressure hydrogen is used in hydrogen stations, with its parts being developed. On the other hand, ultra-high-pressure ball valve, which is one of its parts, depends on overseas, with the level of domestic research on this being only about 10% of advanced technology research on this abroad. In this study, the shape of an ultra-high-pressure ball valve for a hydrogen station was designed to improve its structural strength. The valve body was designed according to distance between both processed body holes along inlet and outlet ports. The designed vale body was then analyzed using ANSYS to check whether points with stress were concentrated. In addition, the valve with improved body was analyzed to confirm that the valve satisfied the design condition.

스윙형 역지 밸브의 열림 특성에 관한 실험적 연구 (Experimental Study on the Opening Characteristics for Swing Check Valves)

  • 송석윤;김양석;박성근;홍승열
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.555-561
    • /
    • 2003
  • The experimental apparatus is designed and installed to measure the disc positions with flow velocity, $V_{open}\;and\;V_{min}$ for 3 inch and 6 inch swing check valves. The minimum flow velocity necessary to just open the disc at a full open position is referred to as $V_{open}\;and\;V_{min}$ is defined as the minimum velocity to fully open the disc and hold it without motion. In the experiments, $V_{min}$ is determined as the minimum flow velocity at which the back stop load begins to increase after the disc is idly opened or the oscillation level of disc is reduced below $1^{\circ}$. The results show that the $V_{min}$ velocities for 3 inch and 6 inch swing check valves are about 15.6% and 4.8% higher than the $V_{open}$ velocities, respectively. Although the experiments were done with the stable uniform flow, additional experiments will be performed to determine the effects of the upstream disturbances.

  • PDF