• Title/Summary/Keyword: Check angle

Search Result 221, Processing Time 0.027 seconds

Construction of 3D Spatial Information of Vertical Structure by Combining UAS and Terrestrial LiDAR (UAS와 지상 LiDAR 조합에 의한 수직 구조물의 3차원 공간정보 구축)

  • Kang, Joon-Oh;Lee, Yong-Chang
    • Journal of Cadastre & Land InformatiX
    • /
    • v.49 no.2
    • /
    • pp.57-66
    • /
    • 2019
  • Recently, as a part of the production of spatial information by smart cities, three-dimensional reproduction of structures for reverse engineering has been attracting attention. In particular, terrestrial LiDAR is mainly used for 3D reproduction of structures, and 3D reproduction research by UAS has been actively conducted. However, both technologies produce blind spots due to the shooting angle. This study deals with vertical structures. 3D model implemented through SfM-based image analysis technology using UAS and reproducibility and effectiveness of 3D models by terrestrial LiDAR-based laser scanning are examined. In addition, two 3D models are merged and reviewed to complement the blind spot. For this purpose, UAS based image is acquired for artificial rock wall, VCP and check point are set through GNSS equipment and total station, and 3D model of structure is reproduced by using SfM based image analysis technology. In addition, Through 3D LiDAR scanning, the 3D point cloud of the structure was acquired, and the accuracy of reproduction and completeness of the 3D model based on the checkpoint were compared and reviewed with the UAS-based image analysis results. In particular, accuracy and realistic reproducibility were verified through a combination of point cloud constructed from UAS and terrestrial LiDAR. The results show that UAS - based image analysis is superior in accuracy and 3D model completeness and It is confirmed that accuracy improves with the combination of two methods. As a result of this study, it is expected that UAS and terrestrial LiDAR laser scanning combination can complement and reproduce precise three-dimensional model of vertical structure, so it can be effectively used for spatial information construction, safety diagnosis and maintenance management.

Study on Measurement Condition Effects of CRP-based Structure Monitoring Techniques for Disaster Response (재해 대응을 위한 CRP기반 시설물 모니터링 기법의 계측조건 영향 분석)

  • Lee, Donghwan;Leem, Junghyun;Park, Jihwan;Yu, Byoungjoon;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.541-547
    • /
    • 2017
  • Climate change has become the main cause of the exacerbation in natural disasters. Social Overhead Capital(SOC) structure needs to be checked for displacement and crack periodically to prevent damage and the collapse caused by natural disaster and ensure the safety. For efficient structure maintenance, the optical image technology is applied to the Structure Health Monitoring(SHM). However, optical image is sensitive to environmental factors. So it is necessary to verify its validity. In this paper, the accuracy of estimating the vertical displacement was verified with respect to environmental condition such as natural light, measurement distance, and the number of image sheets. The result of experiments showed that the effect of natural light on accuracy of estimating vertical displacement was the greatest of all. The measurement angle which was affected by the change in measurement distance was also important to check the vertical displacement. These findings will be taken into account by applying appropriate environmental condition to minimize errors when the bridge was measured by camera. It will also enable the application of optical images to the SHM.

TACAN modulation generator for antenna purpose that precisely adjusts factor of modulation (변조도를 정밀하게 조정 하는 TACAN 안테나용 변조신호발생기)

  • Kim, Jong-Won;Son, Kyong-Sik;Lim, Jae-Hyun
    • Journal of Digital Convergence
    • /
    • v.15 no.4
    • /
    • pp.275-284
    • /
    • 2017
  • TACAN(TACtical Air Navigation) was created to support military aircraft's short range navigation (200~300 mile). TACAN must fulfill a condition of MIL-STD-291C, the U.S. Military Standards, which addresses the sum of 15Hz and 135Hz should be within 55%, following the factor of modulations for both to be $21{\pm}9%$ each. Within the existing TACAN antenna, modulation factor for 15Hz and 135Hz are created differently depending on its diameter, wavelength, angle of gradient, internal modulation method or using frequency code. It brings up a problem where applications needed to be stopped and repaired when modulating signal exceeds the standard of MIL-STD-291C since the existing TACAN antenna does not have coordination function. Hence, plan and produce a modulating signal generator using FPGA, and check the changes in the modulation factor for 15HZ and 135Hz, depending on the values that have been set in each criteria. Moreover, allow the modulating signal generator to be automatically adjusted based on the monitoring signal emitted by antenna, and place alarm sound just in case if it exceeds the standard.

A case of oral rehabilitation using implant fixed prosthesis (skeletal class III malocclusion patient) (골격성 III급 부정교합을 가진 환자에서 임플란트 지지 고정성 보철을 이용한 구강회복 증례)

  • Minjung Kang;Minji Sun;Hong Seok Moon;Jong-Eun Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.125-134
    • /
    • 2023
  • When the patient with class III malocclusion needs extensive oral rehabilitation due to multiple missing teeth, accurate diagnosis, and careful analysis, such as the patient's occlusal relationship, facial changes, and evaluation of the temporomandibular joint are essential. Orthognathic surgery is often performed for aesthetic improvement, depending on the patient's chief complaint. If it is not possible due to certain circumstances, partial aesthetic improvement can be achieved through minimal elevation of the vertical dimension. As this patient may have unexpected issues, such as temporomandibular joint disorder, oral habits like bruxism, and masticatory muscle tension, it was determined whether the patient could adjust to a reversible temporary removable partial denture. After this, the maxillary implant-supported fixed prostheses and the mandibular fixed prostheses were used to achieve stable posterior support and to partially improve the maxillary anterior esthetics. The patient was satisfied with the results both aesthetically and functionally. The prognosis is expected to be good if regular check-ups are conducted.

A Study on Jointed Rock Mass Properties and Analysis Model of Numerical Simulation on Collapsed Slope (붕괴절토사면의 수치해석시 암반물성치 및 해석모델에 대한 고찰)

  • Koo, Ho-Bon;Kim, Seung-Hee;Kim, Seung-Hyun;Lee, Jung-Yeup
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.5
    • /
    • pp.65-78
    • /
    • 2008
  • In case of cut-slopes or shallow-depth tunnels, sliding along with discontinuities or rotation could play a critical role in judging stability. Although numerical analysis is widely used to check the stability of these cut-slopes and shallow-depth tunnels in early design process, common analysis programs are based on continuum model. Performing continuum model analysis regarding discontinuities is possible by reducing overall strength of jointed rock mass. It is also possible by applying ubiquitous joint model to Mohr-Coulomb failure criteria. In numerical analysis of cut-slope, main geotechnical properties such as cohesion, friction angle and elastic modulus can be evaluated by empirical equations. This study tried to compare two main systems, RMR and GSI system by applying them to in-situ hazardous cut-slopes. In addition, this study applied ubiquitous joint model to simulation model with inputs derived by RMR and GSI system to compare with displacements obtained by in-situ monitoring. To sum up, numerical analysis mixed with GSI inputs and ubiquitous joint model proved to provide most reliable results which were similar to actual displacements and their patterns.

Development of an Immersive Virtual Reality-Based Bathroom Self-Remodeling System

  • Mi-Young Song
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.4
    • /
    • pp.63-72
    • /
    • 2024
  • The size of the home interior market is growing rapidly as interest in interiors and self-interiors has increased due to the recent rapid increase in single-person households. Most of the Bathroom remodeling is done by requesting an offline interior contractor and then visually checking it in the final completion stage, so it is not easy to re-construct even if the customer is dissatisfied. Therefore, this study developed an immersive virtual reality-based Bathroom self-remodeling system that can visually check space and design from the design stage to the final stage by incorporating VR technology to feel realistic in virtual reality. The bathroom structure may select the basic structure of the predefined bathroom space or freely set the size of the bathroom space. For furniture items, you can choose the washbasin, toilet, bathtub, shower booth that are essential elements of the bathroom and others(mounting rack, trash bin, handle). The tile texture may change the texture of the selected tile at a desired wall position by selecting various textures. In particular,, the texture of the wall tile can be varied by selecting horizontal, vertical and inclined directions at the desired angle according to the needs of the user and the contractor. As a future research project, this system will enable indoor sharing between users who are physically far away in real-time, allowing direct experience in virtual spaces, connection to purchases, and request estimates.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

Evaluation of accuracy in the ExacTrac 6D image induced radiotherapy using CBCT (CBCT을 이용한 ExacTrac 6D 영상유도방사선치료법의 정확도 평가)

  • Park, Ho Chun;Kim, Hyo Jung;Kim, Jong Deok;Ji, Dong Hwa;Song, Ju Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.109-121
    • /
    • 2016
  • To verify the accuracy of the image guided radiotherapy using ExacTrac 6D couch, the error values in six directions are randomly assigned and corrected and then the corrected values were compared with CBCT image to check the accurateness of ExacTrac. The therapy coordination values in the Rando head Phantom were moved in the directions of X, Y and Z as the translation group and they were moved in the directions of pitch, roll and yaw as the rotation group. The corrected values were moved in 6 directions with the combined and mutual reactions. The Z corrected value ranges from 1mm to 23mm. In the analysis of errors between CBCT image of the phantom which is corrected with therapy coordinate and 3D/3D matching error value, the rotation group showed higher error value than the translation group. In the distribution of dose for the error value of the therapy coordinate corrected with CBCT, the restricted value of dosage for the normal organs in two groups meet the prescription dose. In terms of PHI and PCI values which are the dose homogeneity of the cancerous tissue, the rotation group showed a little higher in the low dose distribution range. This study is designed to verify the accuracy of ExacTrac 6D couch using CBCT. It showed that in terms of the error value in the simple movement, it showed the comparatively accurate correction capability but in the movement when the angle is put in the couch, it showed the inaccurate correction values. So, if the body of the patient is likely to have a lot of changes in the direction of rotation or there is a lot of errors in the pitch, roll and yaw in ExacTrac correction, it is better to conduct the CBCT guided image to correct the therapy coordinate in order to minimize any side effects.

  • PDF

INHIBITORY EFFECT OF Er:YAG LASER ON THE GROWTH OF STREPTOCOCCUS MUTANS (Er:YAG 레이저 조사가 Streptococcus mutans의 증식억제에 미치는 효과)

  • Song, Gwang-Chul;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.15-24
    • /
    • 2003
  • The purpose of this study is to investigate the sterilization effect of Er:YAG laser against the intraoral acid producing bacterium, S. mutans, by irradiating the culture solution containing S. mutans KCTC 3065 with Er:YAG laser having a $650{\mu}m$ diameter beam through the non-contact method. We obtained the following results after examining the temperature changes of the culture solution, numbers of bacterial colonies, and acid-producing ability and attaching ability on teeth by measuring the amount of extracellular polysaccharide produced by S. mutans. The number of bacterial colony was decreased in $10{\mu}l$ culture solution irradiated with laser in overall compared to the control solution. The number decreased as the irradiation intensity and pulse repetition rate were larger and as the exposure time was increased. However, it did not change significantly in $100{\mu}l$ culture solution compared to the control solution. Although the acid-producing ability of S. mutans was inhibited for a certain duration after laser irradiation in 10r1 bacterial culture solution, it did not change in $100{\mu}m$ solution compared with the control solution. The amount of extracellular polysaccharide synthesized by S. mutans was partially decreased through laser irradiation in $10{\mu}m$ culture solution but did not change in $100{\mu}m$ culture solution. Based on these findings, we concluded that Er:YAG laser has an sterilization effect on S. mutans in which we presume that the mechanism is through the heat effect rather than the mechanical effect from development of ultrasound.

  • PDF