• Title/Summary/Keyword: Charging scenarios

Search Result 34, Processing Time 0.072 seconds

Evaluation of the Charging effects of Plug-in Electrical Vehicles on Power Systems, taking Into account Optimal Charging Scenarios (전기자동차의 충전부하 모델링 및 충전 시나리오에 따른 전력계통 평가)

  • Moon, Sang-Keun;Gwak, Hyeong-Geun;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.783-790
    • /
    • 2012
  • Electric Vehicles(EVs) and Plug-in Hybrid Electric Vehicles(PHEVs) which have the grid connection capability, represent an important power system issue of charging demands. Analyzing impacts EVs charging demands of the power system such as increased peak demands, developed by means of modeling a stochastic distribution of charging and a demand dispatch calculation. Optimization processes proposed to determine optimal demand distribution portions so that charging costs and demand can possibly be managed. In order to solve the problems due to increasing charging demand at the peak time, alternative electricity rate such as Time-of-Use(TOU) rate has been in effect since last year. The TOU rate would in practice change the tendencies of charging time at the peak time. Nevertheless, since it focus only minimizing costs of charging from owners of the EVs, loads would be concentrated at times which have a lowest charging rate and would form a new peak load. The purpose of this paper is that to suggest a scenario of load leveling for a power system operator side. In case study results, the vehicles as regular load with time constraints, battery charging patterns and changed daily demand in the charging areas are investigated and optimization results are analyzed regarding cost and operation aspects by determining optimal demand distribution portions.

Optimal Scheduling of Electric Vehicles Charging in low-Voltage Distribution Systems

  • Xu, Shaolun;Zhang, Liang;Yan, Zheng;Feng, Donghan;Wang, Gang;Zhao, Xiaobo
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.810-819
    • /
    • 2016
  • Uncoordinated charging of large-scale electric vehicles (EVs) will have a negative impact on the secure and economic operation of the power system, especially at the distribution level. Given that the charging load of EVs can be controlled to some extent, research on the optimal charging control of EVs has been extensively carried out. In this paper, two possible smart charging scenarios in China are studied: centralized optimal charging operated by an aggregator and decentralized optimal charging managed by individual users. Under the assumption that the aggregators and individual users only concern the economic benefits, new load peaks will arise under time of use (TOU) pricing which is extensively employed in China. To solve this problem, a simple incentive mechanism is proposed for centralized optimal charging while a rolling-update pricing scheme is devised for decentralized optimal charging. The original optimal charging models are modified to account for the developed schemes. Simulated tests corroborate the efficacy of optimal scheduling for charging EVs in various scenarios.

Receiver Protection from Electrical Shock in Vehicle Wireless Charging Environments

  • Park, Taejun;Hwang, Kwang-il
    • Journal of Information Processing Systems
    • /
    • v.16 no.3
    • /
    • pp.677-687
    • /
    • 2020
  • This paper deals with the electrical shock that can occur in a car wireless charging system. The recently released the Wireless Power Consortium (WPC) standard specifies that the receiver must be protected from the radio power generated by the transmitter and presents two scenarios in which the receiver may be subjected to electrical shock due to the wireless power generated by the transmitter. The WPC also provides a hardware approach for blocking the wireless power generated by the transmitter to protect the receiver in each situation. In addition, it presents the hardware constraints that must be applied to the transmitter and the parameters that must be constrained by the software. In this paper, we analyze the results of the electric shock in the vehicle using the WPC certified transmitter and receiver in the scenarios presented by WPC. As a result, we found that all the scenarios had electrical shocks on the receiver, which could have a significant impact on the receiver circuitry. Therefore, we propose wireless power transfer limit (WPTL) algorithm to protect receiver circuitry in various vehicle charging environments.

Analysis of Safety by Expansion of Hydrogen Charging Station Facilities (수소충전소 설비 증설에 따른 안전성 해석)

  • Park, Woo-Il;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.83-90
    • /
    • 2020
  • This study conducted a risk assessment using the HyKoRAM program created by international joint research. Risk assessment was conducted based on accident scenarios and worst-case scenarios that could occur in the facility, reflecting design specifications of major facilities and components such as compressors, storage tanks, and hydrogen pipes in the hydrogen charging station, and environmental conditions around the demonstration complex. By identifying potential risks of hydrogen charging stations, we are going to derive the worst leakage, fire, explosion, and accident scenarios that can occur in hydrogen storage tanks, treatment facilities, storage facilities, and analyze the possibility of accidents and the effects of damage on human bodies and surrounding facilities to review safety.

Impact of Electric Vehicle Penetration-Based Charging Demand on Load Profile

  • Park, Woo-Jae;Song, Kyung-Bin;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.244-251
    • /
    • 2013
  • This paper presents a study the change of the load profile on the power system by the charging impact of electric vehicles (EVs) in 2020. The impact of charging EVs on the load demand is determined not only by the number of EVs in usage pattern, but also by the number of EVs being charged at once. The charging load is determined on an hourly basis using the number of the EVs based on different scenarios considering battery size, model, the use of vehicles, charging at home or work, and the method of charging, which is either fast or slow. Focusing on the impact of future load profile in Korea with EVs reaching up 10 and 20 percentage, increased power demand by EVs charging is analyzed. Also, this paper analyzes the impact of a time-of-use (TOU) tariff system on the charging of EVs in Korea. The results demonstrate how the penetration of EVs increases the load profile and decreases charging demand by TOU tariff system on the future power system.

Overload Analysis of Distribution Systems make use of PEVs Charging Modeling (전기 자동차의 충전 모델링을 이용한 배전계통 과부하 분석)

  • Choi, Sang-Bong;Lee, Jae-Jo;Sung, Back-Sub
    • Journal of Energy Engineering
    • /
    • v.29 no.3
    • /
    • pp.74-85
    • /
    • 2020
  • This paper presents an algorithm that evaluated the overload influence by bus upon the distribution system by calculating the daily load curve of PEVs charging by bus based on the daily charging patterns of PEVs according to PEVs penetration scenarios. The proposed algorithm calculates the number of PEVs to estimate the number of households by bus; the probability density function of the charging start time of PEVs, considering driving characteristics of PEVs and the daily load curve of PEVs charging by bus considering battery characteristics according to PEVs penetration scenarios. To verify the evaluation of the overload influence by bus on the distribution system in terms of the proposed algorithm, the cases were reviewed on the target bus(apartment and detached houses) among the feeders of the distribution systems at Dongtan new-town in Korea.

Analysis for Evaluating the Impact of PEVs on New-Town Distribution System in Korea

  • Choi, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.859-864
    • /
    • 2015
  • This paper analyzes the impact of Plug-in Electric vehicles(PEVs) on power demand and voltage change when PEVs are connected to the domestic distribution system. Specifically, it assesses PEVs charging load by charging method in accordance with PEVs penetration scenarios, its percentage of total load, and voltage range under load conditions. Concretely, we develop EMTDC modelling to perform a voltage distribution analysis when the PEVs charging system by their charging scenario was connected to the distribution system under the load condition. Furthermore we present evaluation algorithm to determine whether it is possible to adjust it such that it is in the allowed range by applying ULTC when the voltage change rate by PEVs charging scenario exceed its allowed range. Also, detailed analysis of the impact of PEVs on power distribution system was carried out by calculating existing electric power load and additional PEVs charge load by each scenario on new-town in Korea to estimate total load increases, and also by interpreting the subsequent voltage range for system circuits and demonstrating conditions for countermeasures. It was concluded that total loads including PEVs charging load on new-town distribution system in Korea by PEVs penetration scenario increase significantly, and the voltage range when considering ULTC, is allowable in terms of voltage tolerance range up to a PEVs penetration of 20% by scenario. Finally, we propose the charging capacity of PEVs that can delay the reinforcement of power distribution system while satisfying the permitted voltage change rate conditions when PEVs charging load is connected to the power distribution system by their charging penetration scenario.

Evaluation for Charging effects of Plug-in Electrical Vehicles in Power System considering Optimal Charging scenarios (전기자동차의 충전부하특성 모델링 및 충전 시나리오에 따른 계통평가)

  • Moon, Sang-Keun;Kim, Sung-Yul;Kin, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.298-299
    • /
    • 2011
  • The impacts of EV charging demands on power system such as increased peak demands may be developed by means of modeling a stochastic distribution of charging and a demand dispatch calculation. Optimization processes are proposed to determine optimal demand distribution portions so that charging costs and demands can be managed optimally. There are two optimization methods which have different effects on the outcome. These focus either on the Electric vehicle customer side (cost optimization) or the System Operator side (Load-weighted optimization).

  • PDF

Development and Selection of Accident Scenarios for Risk Assessment in HF Charging Process (HF 충진 공정의 위험성 평가를 위한 가상사고 시나리오 발굴 및 선정)

  • Jang, Chang-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.26-32
    • /
    • 2013
  • The best way to prevent major occupational accidents is prohibiting use of hazardous substances such as flammable gas, toxic gas whereas using alternative substances that ensured safety. but if there are no economic efficiency and substituting technologies of alternative substances, the best way is preparing to prevent accidents thoroughly. Therefore, this study has developed and selected release scenarios to use and apply for consequence analysis and emergency action plan for HF charging process of chemical plants that have HF release accidents and high probability of release accidents.

A Study on the Application of Business Disaster Reduction Activities to Strengthen the Business Continuity of Hydrogen Charging Stations (수소충전소의 사업연속성 강화를 위한 기업재해경감활동 적용 연구)

  • Jang Won Lee;Chang Soo Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.411-420
    • /
    • 2023
  • Purpose: In order to compensate for the limitations of the risk assessment of hydrogen charging stations, it is proposed to apply business disaster reduction activities as a way to strengthen safety and business continuity for accidents that may occur during operation. Method: We explored the application of business disaster reduction activities that can reduce, eliminate, transfer, and accept risks by classifying risks according to the passage of time in the installation and operation of hydrogen charging stations, identifying key tasks, deriving risk scenarios. Result: Existing research results are appropriately applied to the risk assessment conducted in the stage before the installation of hydrogen charging stations. However, there is a limit to the risks that can occur at the operational stage, so applying business disaster reduction activities with several example scenarios has resulted in that it can be applied as a way to strengthen safety and business continuity. Conclusion: All of the currently implemented risk assessments for hydrogen charging stations are being used appropriately. However, it proposes business disaster reduction activities that apply various risk scenarios as an evaluation and response to possible risks at the operational stage.