• Title/Summary/Keyword: Charging Particles

Search Result 93, Processing Time 0.024 seconds

Collection Efficiency of Particles with Effect of Blocks in the Two-Stage Electrostatic Precipitator (2단식 전기집진기 내에서 블록의 영향에 따른 입자의 집진효율)

  • 박성호;박청연
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.217-218
    • /
    • 2000
  • 유해입자 배출 저감을 위한 대기오염 제어장치로는 필터(filter), 관성장치(inertialdevices), 침전조(settling), 스크루버(scrubber), 전기집진기(ElectroStatic Precipitator, ESP)등이 있다. 이 중, 정전기력을 이용한 전기집진기는 대전과정과 집진과정이 동일한 곳에서 이루어지는 1단식(one-stage)과 독립적으로 이루어지는 2단식(two-stage)으로 분류되며, 2단식의 경우, 대전부(charging section)와 집진부(collecting section)는 몇 개의 대전셀(charging cell)과 집진셀(collecting cell)들로 구성되어져 있다. (중략)

  • PDF

Nano Particle Charging Characteristics of Aerosol Charge Neutralizers (에어로졸 중화기의 나노 입자 하전 특성)

  • Ji, Jun-Ho;Bae, Swi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1489-1497
    • /
    • 2003
  • Aerosol charge neutralizers with various radioactive sources have been used to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. Measurements of highly charged particles are needed in air cleaning devices, e.g. electrostatic precipitator, bag filter with a pre-charger, and electrical cyclone. In this study, the particle charging characteristics of two different aerosol charge neutralizers were experimentally investigated for singly charged monodisperse particles and highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0,5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.2 to 2.5 L/min. The results show that the charge distribution of singly charged monodisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer is well agreed with the Boltzmann equilibrium charge distribution at an air flow rate of 0.3 L/min, However, it deviates from the equilibrium charge distribution when the air flow rates are 0.6, 1,0, and 1,5 L/min, On the other hands, the effect of air flow rate is insignificant for the $^{210}$ Po aerosol charge neutralizer. The non-equilibrium character in charge distribution of highly charged polydisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer greatly depends on the air flow rate, however it is insensitive to the air flow rate for the $^{210}$ Po aerosol charge neutralizer.

Bipolar Charge Distribution of Nano Particles Passing through the Dielectric Barrier Discharge Reactor (DBD(Dielectric Barrier Discharge)에 의해 하전된 나노입자의 양극성 대전량 분포)

  • Ji, Jun-Ho;Kang, Suk-Hoon;Byeon, Jung-Hoon;Hwang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1684-1689
    • /
    • 2003
  • Dielectric Barrier Discharges (DBD) in oxygen and air are well established for the production of large quantities of ozone and are more recently being applied to a wider range of after treatment processes for HAPs(Hazardous Air Pollutants). The potential use as a charger for particle collection are not well known. In this work, we measured charge distribution of nanometer or submicron sized particles passing through the dielectric barrier discharge reactor. The bipolar charge characteristics of particles passing DBD reactor were investigated. Fluorometric method using uranine particles and a fluorometer was employed to examine the bipolar charging characteristics of the charged particles by DBD reactor. Finally, the charge distributions of particles were determined from the electrical mobility classification using DMA.

  • PDF

Measurements of Particles Size Distribution and Average Particle Charge in Operating a Bard Disk Drive (하드디스크 드라이브 동작 시 발생하는 입자 크기분포와 입자당 평균 대전량 측정)

  • Lee Jaeho;Park Dongho;Lee Dae-Young;Yoon Ki-Young;Hwang Jungho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.795-804
    • /
    • 2005
  • As the flying height of a slider in a hard disk drive decreases, the slider and disk are more likely to come in contact and generate contamination particles. Since particle contamination can cause serious problems including thermal asperity, it must be prevented to increase storage capacity. When particles are generated in a HDD, particles can be charged and have a few number of elementary charges. In this paper, the size distribution of particles and electrical current due to particle according to the disk rotational speed were measured. Also, the average number of elementary charges was calculated from experimental data. SEM images of particles were obtained by using a particle sampler designed in our laboratory.

Collection Performance of an Electret Cabin Air Filter for Fine Particles (승용차용 정전 필터의 미세 입자 포집 특성)

  • Ji, Jun-Ho;Gang, Seok-Hun;Kim, Dong-Cheol;Hwang, Jeong-Ho;Yun, Ung-Seop;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1650-1658
    • /
    • 2001
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the fractional collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using highly monodisperse particles ranging from 0.02 to 0.6 $\mu\textrm{m}$ in diameter at three different charging states: singly charged, uncharged, and equilibrium charged. The face velocity was varied from 2.4 to 20.4 crus. It was fecund that the fractional efficiency curve fur singly charged particles shows a typical trend that the collection efficiency is minimum at about 0.3 $\mu\textrm{m}$ in diameter. The fractional efficiency of equilibrium charged particles were not severely varied with the particle diameter. The collection efficiency curve fur uncharged particles has a minimum near 0.1 $\mu\textrm{m}$ in diameter. Another experiment was conducted for a cartridge filter to examine the effect of charge depletion on the collection efficiency in a cabin air filter. The result shows that the charge depletion of the cartridge filter can significantly lower the collection efficiency.

Aggregation of Nanoparticles Using a Unipolar Charging Technique (단극하전을 이용한 나노입자 응집성장 제어)

  • Park, Hyung-Ho;Kim, Sang-Soo;Chang, Hyunk-Sang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.1
    • /
    • pp.46-53
    • /
    • 2003
  • Effects of electric force on the morphology and growth of aggregates were studied experimentally. Nano-sized NaCl particles were supplied to a flame to perform the unipolar charging state. This electric precursor did not modify a temperature profile of the flame. The morphology of aggregates was measured by TEM image processing technique and the light scattering technique. In the unipolar charged state, the fractal dimension of aggregates was smaller than that of' the electrically neutral state. This result was in good agreement with our previous numerical simulations.

Approach to Characterization of a Diode Type Corona Charger for Aerosol Size Measurement

  • Intra Panich;Tippayawong Nakorn
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.5
    • /
    • pp.196-203
    • /
    • 2005
  • A semi-empirical method to determine the electrostatic characteristics of a diode type corona aerosol charger based on ion current measurement and electrostatic charging theory was presented. Results from mathematical model were in agreement with those from experimental investigation of the charger. Current-voltage characteristics, $N_{i}t$ product and charge distribution against aerosol size were obtained. It was shown that the space charge was significant and must be taken into account at high ion number concentration and low flow rate. Additionally, significant particle loss was evident for particles smaller than 20 nm in diameter where their electrical mobility was high. Increase in charging efficiency may be achieved by introducing surrounding sheath flow and applying AC high voltage. Overall, the approach was found to be useful in characterizing the aerosol charger.

Charge Distribution of Submicron Particles Charged by Spray Electrification or Corona Discharge (분무 및 코로나 방전에 의해 대전된 서브마이크론 입자의 대전량 분포)

  • Lee, Jae-Bok;Bae, Gwi-Nam;Hwang, Jeong-Ho;Lee, Gyu-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.124-132
    • /
    • 2001
  • This paper reports on the charge distribution measurements of submicron particles for three different charging mechanisms, which are spray electrification, bipolar ionization and corona discharge process, respectively. The number of elementary charges per particle was investigated by classifying and counting of a discrete mobility class. Charge distribution measurements were performed with NaCl particles generated from a collision atomizer for 0.01, 0.1, 1% NaCl solutions. Experimental results show than charge level of atomized NaCl particles is high and decreases with increasing the dissolved ion concentration. The charge level of the atomized NaCl particles can be reduced to that o Boltzmann equilibrium conditions by the bipolar ionization(Po(sup)210 bipolar ionizer). The charge level on NaCl particles passing through the corona discharge reactor is much higher than those of atomized or bipolar ionized NaCl particles. The evaluation of these measurements results in charge distribution of the submicron particles.

Hydrogen Embrittlement Properties of Austenitic Fe-30Mn-0.2C(-1.5Al) High-Manganese Steels for Cryogenic Applications (극저온용 오스테나이트계 Fe-30Mn-0.2C(-1.5Al) 고망간강의 수소 취화 특성)

  • Lee, Sang-In;Lee, Ji-Min;Hwang, Byoungchul
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.31 no.6
    • /
    • pp.283-289
    • /
    • 2018
  • This present study deals with the hydrogen embrittlement properties of austenitic Fe-30Mn-0.2C(-1.5Al) high-manganese steels for cryogenic applications. They were electrochemically charged with hydrogen and then subjected to tensile tests for evaluating hydrogen embrittlement behavior. Tensile test results showed that after hydrogen charging the tensile strength and elongation of the Al-free steel were more remarkably decreased with increasing current density when compared to the Al-added steel. After hydrogen charging of the Al-added steel, it was found that the measured hydrogen content was small and silver particles were relatively less decorated. Therefore, the Al-added steel has a superior hydrogen embrittlement resistance to the Al-free steel because the addition of Al suppresses the injection of hydrogen during electrochemical hydrogen charging.

Experiment on Collection Characteristics of Sub micron Particles in Two-Stage Parallel-Plate Electrostatic Precipitators (2단 평행판 전기집진기의 서브마이크론 입자 포집특성 실험)

  • Oh, M.D.;Yoo, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.237-246
    • /
    • 1994
  • Experimental data are reported for charging and collection of NaCl aerosols in the 0.03- to $0.2{\mu}m$-geometric-mean-diameter range in 2-stage parallel-plate electrostatic precipitators. The NaCl aerosols are generated with geometric standard deviation of about 1.74 and particle generation rate of about 10^9 particles/see by the constant output atomizer and injected into the air flow in the clean wind-tunnel. The 2-stage parallel-plate electrostatic precipitator installed in the test section of the wind-tunnel is operated with a positive corona discharge. The NaCl aerosols in the channel flow are sampled and transported to the aerosol particle number concentration measurement system by using the isoaxial sampling and transport system constructed based on the Okazaki and Willeke design. The aerosol particle number concentration measurement system measures the size distribution of submicrometer aerosols by an electrical mobility detection technique. It is confirmed from comparing the measured collection efficiencies in this study and the predicted ones by our previous theoretical analysis that the predicted collection efficiencies agree well with the experimental ones. It is also found from the comparison that below about $0.02{\mu}m$ all particles are not charged and the uncharged particles are not collected, and consequently 2-stage parallel-plate electrostatic precipitators are not suitable for that particle size range.

  • PDF