• Title/Summary/Keyword: Charge Calculation

Search Result 279, Processing Time 0.035 seconds

Theoretical Analysis of Dipole Moment Derivatives in Fluoromethanes. (II) Difluoromethane

  • Kim, Kwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.1
    • /
    • pp.10-15
    • /
    • 1987
  • The results of an ab initio (6-31G) molecular orbital calculation of the dipole moment derivatives and gas phase IR intensities of difluoromethane are reported. The results are compared with corresponding values obtained from a CNDO calculation. The directions of the dipole derivatives calculated by the two methods agree very well, whereas the intensities differ significantly. The results are also analyzed for the charge-charge flux-overlap electronic contributions to the dipole derivatives.

A Study on A Spiral Charge for 3 Dimensional Charge Simulation Method (3차원 전하 중첩법용 나선 전하의 특성에 관한 연구)

  • 민석원;박은서;송기현
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.31-36
    • /
    • 2001
  • This paper investigates characteristics of spiral charge for 3 dimensional charge simulation method to calculate electric fields of special conductor bundles with spiral rods in 765kV transmission line. We finds the simulating spiral charge as constant charge density give less potential calculation error than sinusoidal charge falsity. When a spiral rod is simulated as spiral charge, we also knows two spiral charge can simulate spiral rod best.

  • PDF

Educational Simulator for Transmission Network Use of System Charge (송전망 이용요금산정을 위한 교육용 시뮬레이터 개발)

  • Kim, H.H.;Song, H.Y.;Lee, C.J.;Park, J.B.;Shin, J.R.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.201-203
    • /
    • 2006
  • This paper presents a graphical windows-based software for the education and training of the transmission network use of system charge. The developed simulator consist of the main module(MMI,GUI), the power flow module(PF), the power flow tracing module(PFT) and management of usage cost DB module(UCD). Each module has a separate graphical and interactive interfacing window. To have effective education for transmission network use of system charge, the developed simulator are provided with two power system analysis methods. Input data of power system can use the format of PSS/E input data. Also calculation of power flow tracing are provided with four methods such as "Felix Wu","Modified Felix Wu", "DCLF ICRP" and "Reverse MW mile". Results of calculation for usage cost are shown on the window through the table or chart. Therefore user can confirm the detailed differences of results from each calculation method.

  • PDF

Performance Evaluations of a Residential Small Multi-Refrigeration System Considering the Adiabatic Characteristics (단열 특성을 고려한 가정용 소형 멀티 냉동시스템의 성능에 관한 연구)

  • Lee, Moo-Yeon;Lee, Dong-Yeon;Joo, Young-Ju;Kim, Sang-Uk;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.868-875
    • /
    • 2007
  • In this paper, performance characteristics of a domestic kim-chi refrigerator are predicted by using the theoretical calculation and experimental method. The objective of this study is to find out the best design points of the refrigeration system and to calculate an adiabatic characteristic with variation to outdoor temperatures. The best design points such as refrigerant charge amount and capillary length were experimentally investigated. And the theoretical calculation is conducted as a function of calculation parameters and outdoor temperatures. According to this study results, the best design points of a refrigeration system with 2 rooms are 95 g of a refrigerant charge amount and 3500 / 3500 mm of capillary lengths and the best design points of a refrigeration system with 3 rooms are 100 g of a refrigerant charge amount and 3000/3000/6000mm of capillary lengths. And the power consumptions of both systems are 13.57 and 18.2 kWh/month. The worst part of heat loss is a front side of a domestic kim-chi refrigerator body.

A Study on the Bottom-up Long-run Incremental costing Methodology for the Korean Mobile Network (이동통신망 상호접속요금 산정을 위한 장기증분원가모형에 관한 연구)

  • Choe Seon-Mi;Hyeon Chang-Hui
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2004.05a
    • /
    • pp.25-36
    • /
    • 2004
  • The key objective of this paper is to suggest a pilot model for mobile network interconnection charge calculation by bottom-up long-run incremental costing methodology. Interconnection issues have lately attracted considerable attention by network operators and regulators. However there is no standard by all the network operators' agreement. The costing method is an acute problem because the interconnection charge is directly related to the network operators' revenue. Thus Korea has planned to launch the new interconnection policy based on the current traffic distribution and then we simulate the model in a sample area with virtual data. The results propose objective and reasonable guideline for the mobile network element cost calculation. It can be helpful for calculating price floor or bottom-up long run incremental interconnection charge by regulator.

  • PDF

Role of London Energy in Determining the C-Dimensions of Phyllosilicates (층상 규산염광물 C-축 결정에 있어서의 런던에너지 역할)

  • 유재영
    • Journal of the Mineralogical Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.89-97
    • /
    • 1990
  • To examine how London energy controls the c-dimensions of phyllosilicates, London energy, as well as Coulomb and Pauli repulstion energy was calculated as a function of d(001) for 1M and d(002) for 2M 1 phyllosilicates. London and Pauli repulstion energy calcualtion use a direct interaction calculation method and Coulomb energy calculation adopts Fourier synthesis method. The energy calculations show that Coulmb and Pauli repulsion energy dominantly control the c-dimensions of phyllosilicates having the interlayer cationss, i.e., the layer charges. On the other hand, if phyllosilicates have no interlayer cations, London energy is solely responsible for holding the layers and maintain the c-dimensions. The significance of London energy in determining the c-dimensions of phyllosislicates de-creases as the layer charge increases. When the layer charge is lower than one equivalent on the basis of Oη(OH)2 formula, London energy plays an important role in determing the c-dimensions. however, if the layer charge is higher than one equivalent, London energy becomes insignifi-cant in determining the c-dimension.

  • PDF

Three-Dimensional Electric Field Calculation around Substation Busbars Using Adaptive Technique (적응적 기법을 이용한 전력소 모선하의 3차원 전계분포 해석)

  • Myung, Sung-Ho;Lee, Byeong-Yoon;Park, Jong-Keun;Kim, Suk-Won;Kim, Eung-Sik;Lee, Jae-Bok;Ha, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1892-1894
    • /
    • 1996
  • This paper presents optimal charge arrangement through potential error analysis. In order to decide the number of charges per conductor for a large system, adaptive simulation charge arrangement technique has been proposed. "Grouping" technique which means to divide analysis domain into two groups has been described through field error analysis. By this method, the size of matrix to calculate E field at a calculation point is reduced remarkably. The proposed method is applied to the electric field calculation around the Substation busbars.

  • PDF

Evaluation on the Cyclic and Adiabatic Performance of a Small Multi-Refrigeration system (김치냉장고를 중심으로한 소형 멀티 냉동시스템의 성능특성 변화에 관한 연구)

  • Lee, Moo-Yeon;Choi, Seok-Jae;Kim, Sang-Ok;Lee, Won-Keum
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.769-774
    • /
    • 2003
  • In this paper, the performance of a domestic Kim-Chi refrigerator is predicted by using a calculation model & experiment. The objectives of this study are to find out the best design points of a refrigeration system and calculate an adiabatic characteristic to change outdoor temperature. The best design points such as refrigerant charge and capillary length were experimentally investigated. And the calculation model is conducted as a function of calculation parameters and outdoor temperature. According to this study results, the best design points of a refrigeration system are each 95g of a refrigerant charge and 3500/3500mm of capillary lengths. And the power consumption is 13.578 Kwh/month. And a part of the worst heat loss is a front side of a domestic Kim-Chi refrigerator body.

  • PDF

Evaluation of the Effective Charge Density on Low Pressure Nanofiltration with the Separation Characteristics of Monovalent and Divalent Solutes in the Production of Drinking Water

  • Oh, Jeong-Ik;Taro, Urase
    • Environmental Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • The electric charge on a membrane was investigated by analyzing the experimental rejection of various monovalent and divalent ionic solutes. The characteristics of the separation of ionic solutes using various nanofiltration membranes were obtained from an experimental nanofiltration set-up, with a surface area of $40cm^2$ under the operational pressures between 0.25-0.3 MPa. The state of the membrane electric charge was observed using separation coefficients, i.e., the permeation ratio of monovalent to divalent ions. To confirm the state of the membrane charge observed via the separation coefficient, a calculation using the extended Nernst-Planck equation, coupled with the Donnan equilibrium, assuming different electric charge states of the membrane, was compared with the experimental rejection of ionic solutes. The examination of the characteristics of separation using three types of nanofiltration membranes showed that one of the membranes carried a negative/positive double charge density inside, while other two membranes carried either a positive or negative charge density.

Three Dimensional Electric Field Analysis Of Substation Using Nonuniform Optimal Charge Simulation (비균등 최적 전하배치를 이용한 전력소 3차원 전계해석)

  • Myung, Sung-Ho;Lee, Byeong-Yoon;Min, Suk-Won;Kim, Eung-Sik;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.290-292
    • /
    • 1994
  • This paper presents a methodology for the electric field analysis of substation. For the electric field analysis of substation, the electrodes(substation busbars) must be represented by finite line with nonlinear charge density. In the case of dividing finite line into uniform segments, a large number of variables have to be used to obtain the accuracy within a desired tolerance. To deal with the problem, nonuniform charge arrangement modeling method is suggested. To reduce potential calculation errors, the linear charge density function is considered particularly for the segment charge model ling. If the charge arrangement is improper, the accuracy not improved regardless of increment in the number of segments. This paper proposes an optimal charge arrangement method through potential error analysis. And, the optimal charge arrangement function is formulated by a lot of simulation results.

  • PDF