• Title/Summary/Keyword: Characteristic variation

Search Result 1,457, Processing Time 0.027 seconds

The Characteristics of Phase Variation by Depth of Water Column and the Correlation between Channels of Vertical Array Receiver at East Sea (동해 천해환경에서 수심에 따라 변화하는 위상 변동의 특성과 상관관계 분석)

  • Choi, Dong-Hyun;Kim, Hyeon-Su;Kim, Nam-Ri;Kim, Seong-Il;Chung, Jae-Hak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.3
    • /
    • pp.165-172
    • /
    • 2010
  • It is important to determine the communicational method that knows the characteristic of phase variation along transducers formed array within the water column in actual underwater environment and the correlation between transducers. This paper analyzes the characteristic of phase variation that vary on different locations by probe signals that transmitted from a probe source and received along transducers. This paper calculated the theoretical transmission capacities by the analyzation of the correlation between transducers through changing the distance between transducers and the distance between a probe source and transducers.

Watershed Selection for Diffuse Pollution Management Based on Flow Regime Alteration and Water Quality Variation Analysis (유황분석과 수질변화 평가를 통한 비점오염원 관리대상지역 선정방법 연구)

  • Jung, Woohyeuk;Yi, Sangjin;Kim, Geonha;Jeong, Sangman
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.228-234
    • /
    • 2011
  • The goal of water quality management on stream and watershed is to focus not on discharged loads management but on a water quality management. Discharged loads management is not goal of water quality management but way for perform with total maximum daily loads management. It is necessary to estimate the relation between non-point source with stromwater runoff (NPSSR) and water quality to select a watershed where it is required to manage NPSSR for water quality improvement. To evaluate the effects of NPSSR on stream's water quality, we compare the aspects of water quality in dry and wet seasons using flow duration curve analysis based on flow rate variation data by actual surveying. In this study we attempt to quantify the variation characteristic of water quality and estimate the Inflow characteristic of pollution source with water quality and flow rate monitoring on 10 watersheds. We try to estimate water quality and flow rate by regression analysis and try again regression analysis with each high and low water quality data more than estimations. An analysis of relation between water quality and flow rate of 10 watersheds shows that the water quality of the Nonsan and the Ganggyeong streams had been polluted by NPSSR pollutants. Other eight streams were important point source more than NPSSR. It is wide variation range of $BOD_5$ also high average concentration of $BOD_5$. We have to quantify water quality variation by cv1 in wet season and cv365 in dry season with comparing the estimate of high water quality and low water quality. This method can be used to indicator for water quality variation according to flow rate.

Characteristic Variation of Underwater Acoustic Transducer with Electric Decoupler (절연층을 고려한 수중음향 트랜스듀서의 특성변화 고찰)

  • Seo, Hee-Sun;Kim, Jung-Suk;lee, Jeong-Min
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.244-246
    • /
    • 2005
  • The Tonpiltz transducer is one of the essential elements in sonar application. The characteristics of transducer depend on the piezoelectric ceramics and mechanical elements such as head mass, tail mass, pre-stress rod and so on. One of the important characteristics is stable electric resistance for high power transmitting operation. This paper presents characteristics variation of the underwater acoustic transducer with material variation of electric decoupler.

  • PDF

New Sludge Settling Characteristic Index Considering Sludge Settling Velocity (슬러지침전속도를 고려한 새로운 슬러지침전특성지표의 설정에 관한 연구)

  • Park, Suk Gyun;Kang, Seon-Hong;Kim, Dong-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.451-460
    • /
    • 2006
  • While sludge settles down in a batch column, sludge concentration becomes high. Sludge concentration change is one of the most critical causes of the sludge settling velocity variation. Therefore, sludge concentration change causes sludge index to change. SVI is more sensitive than other sludge indexes to the change of sludge concentration. And if sludge-water interface has reached final height within 30minutes, SVI is not suitable for prediction of sludge settling characteristic, Therefore, SVIs of each sludge are, in some cases, different although each sludge has the same settling velocity. But SVI has been widely used to interpret sludge settling characteristic by a simple testing method. This work has two purposes. The first purpose is to predict sludge settling velocity by using sludge-water interface settling velocity. And the second purpose is to develop new sludge settling characteristic index to exactly interpret sludge settling characteristic by overcoming the limit of SVI.

Effects of Characteristic Length Variation for Thrust Chamber on the Hot-fire Performance of Hydrazine Thruster (하이드라진 추력기의 추력실 특성길이 변화가 연소성능에 미치는 영향)

  • Kim, Jong Hyun;Jung, Hun;Kim, Jeong Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.2
    • /
    • pp.144-149
    • /
    • 2014
  • A ground firing test for hot-fire performance evaluation according to the characteristic length($L^*$) variation of thrust chamber was carried out for the hydrazine thruster which may be employed in space launch vehicles. A scrutiny into the performance characteristics of each thruster is made in terms of thrust, specific impulse, response characteristics, and characteristic velocity at steady-state firing mode with propellant inlet pressure of 2.41 MPa (350 psia). Through the test results, it has been verified that performance of characteristic velocity and specific impulse degrades as the characteristic length deviates from that of the standard model. Thus, it is confirmed that the thrust chamber configuration of standard model was suitably designed for the requirement specified.

Estimation of the Variation of Quantity in PWV in Accordance with the Changes of Position in Human (자세변화에 따른 PWV 변화량의 평가)

  • Jun, Suk-Hwan;Jeong, In-Cheol;Jung, Sang-O;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.129-134
    • /
    • 2009
  • The ideal method which measures a blood vessel of senility and degree of arteriosclerosis is to measure compliance of arterial and condition of blood circulation at the periphery. In these days vascular stiffness have been assessed by analyzing PTT (pulse transit time) from ECG and PPG. PTT is that between toe and finger each subject estimated through ECG and PPG signals. Two parameters, which are related to PWV, were tested with the time delay between the finger and toe. PWV is a variation of quantity which is associated with vascular stiffness. These researches which use PTT and PWV don't consider the blood vessel characteristic of an individual. In this current research, we have used with the blood vessel characteristic of an individual. That is an assessment of vascular stiffness using the variation of quantity in PWV with the changes of position in the subject. PWV variation increased as functions of the subject's age. The increase of the PWV variation parameters with age is attributed to the direct decrease of the blood vessel compliance with different position. The quantity of variation estimated by experimental results is that old age's (75.78${\pm}$7.75) case is 113.68% and young age's (26.47${\pm}$2.04) case is 85.69%. We proved and presented about estimation of vascular stiffness of possibility by this result.

Operation Simulation of a Microturbine Based on Test Data (시험 데이터를 지반으로 한 마이크로터빈 운전 시뮬레이션)

  • Lee, Jong-Joon;Yoon, Jae-Eun;Kim, Tong-Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.6 s.39
    • /
    • pp.22-28
    • /
    • 2006
  • Operation of a microturbine was simulated on the basis of component characteristic parameters obtained from performance test. Characteristic parameters, such as compressor and turbine efficiencies, recuperator effectiveness as well as turbine inlet temperature, were obtained for a wide operation range. Component characteristics including performance maps and characteristic curves were generated using measured data. Based on the component characteristics, a simulation program was constructed and operation of the microturbine was simulated, and the simulated results were compared with the measured data to verify the program. Also, influence of variation in the power control scheme on the operating characteristic and performance of the engine was simulated. The simulation program can be used for predicting operation of both healthy and degraded engine conditions.

Dynamic Characteristic Analysis of Single-Phase Line-Start Permanent Magnet Synchronous Motor by Parameter Variation (단상 유도형 동기전동기의 파라미터 변화에 따른 동특성 해석)

  • Oh, Se-Young;Jung, Dae-Sung;Lim, Seung-Bin;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.763-764
    • /
    • 2006
  • In this paper, optimized model was designed for the starting characteristic of the Single-Phase Line-Start Permanent Magnet Synchronous Motor by using the Design of Experiment. A field pole angle, thickness and distance from center axis of permanent magnet were selected as design factor. We executed the transient state characteristic analysis of 8 test models. The transient state characteristic analysis was executed by using the 2 dimensional Finite Element Method and the Time Difference Method. We checked the fact that the selected design factor affected starting characteristic of the Line-Start Permanent Magnet Synchronous Motor. Depend on this result we found the optimized design point by using the response optimization.

  • PDF

Three Dimensional Finite Element Analysis for Piezoelectric Transformer

  • Joo, Hyun-Woo;Lee, Chang-Hwan;Jung, Hyun-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.3
    • /
    • pp.98-103
    • /
    • 2001
  • This paper presents the numerical analysis of piezoelectric devices using three-dimensional finite element analysis. The characteristic of piezoelectric transducer, such as mechanical displacement and electrical are analyzed and the validity is confirmed by experiments Applying the finite element routine to a piezoelectric transformer, the resonance features electrical impedance. the ratio of step-up voltage and vibration mode of piezoelectric transformer are calculated numerically By using three-dimensional finite element method effects of width variation to resonance features, electrical input impedance and the voltage step-up ratio for a piezoelectric transformer, can be considered in design procedure.

Diagnosis of power supply by analysis of chaotic nonlinear dynamics (카오스 비선형 동력학 해석에 의한 수·변전설비의 진단)

  • Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.1
    • /
    • pp.113-119
    • /
    • 2013
  • In this paper, n order to degrade of diagnosis of power supply by using Poincare map and fractal dimension with temperature measured by infrared camera. we review the characteristic of temperature variation according to pattern variation of power supply in chemical industry complex. As a simulation results we can be realized the characteristic behaviors of nonlinear dynamics in the poincare mal and fractal dimension. In the future verification method requires through additional research.